# Sign Regulations in Mangonia Park, Florida

Sign permit rules, size and height limits, setbacks, and ordinance citations for Mangonia Park, Florida, compiled by PermitPal from the jurisdiction's published municipal code.

- **Jurisdiction:** Mangonia Park, Florida (FL)
- **Canonical page:** https://permitpal.io/sign-regulations/florida/mangonia-park
- **Data last verified:** 2025-05-08
- **Source:** [municode municipal code](https://library.municode.com/FL/Mangonia_Park/codes/Code_of_Ordinances?nodeId=CH20SI)

## At a glance

Mangonia Park, Florida regulates 12 sign types across 9 zoning districts. Freestanding Identification Sign (Single Building)s in the Industrial (I), Planned Commerce Center (PCC) zoning district are capped at 10 feet; not above first floor level tall and 50 sq ft per face, with a On property, not projecting into required yards/perimeter buffer. setback (Sec. Appendix A Zoning, Section 12A(10)(a), 19A(15)(b)). Most commercial signs in Mangonia Park require a permit.

## Sign rules by zoning district (9 zones)

| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
| --- | --- | --- | --- | --- |
| Residential Estate (R-E), Low Density Single Family Residential (R-1) | 1 | — | — | — |
| High Density Multiple Family Residential (R-2) | 1 | — | — | — |
| Administrative and Professional District (A-P) | 1 | — | — | — |
| Commercial Recreation (CR) | 2 | 10 feet | — | — |
| Commercial Limited (CL), Shopping Center (SC) | 2 | — | — | — |
| Industrial (I), Planned Commerce Center (PCC) | 6 | 10 feet; not above first floor level | 200 sq ft per face (pair of signs allowed per entry) | — |
| Bioscience Overlay (BOL) | 1 | — | — | — |
| Planned Unit Development (PUD) | 1 | 25 feet (max structure height) | — | — |
| General Regulations For All Zones | 1 | — | — | — |

## Zone-by-zone sign requirements (sample of 3 of 9 zones)

### Commercial Recreation (CR)

| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Ordinance Citation |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Wall Sign | — | — | — | Must be within property subject to setback regulations—see Schedule of Site Regulations for CR. | Subject to site plan approval (generally one per use or entrance) | On principal structure only, facing public street or customer entrance. | — | Appendix A Zoning, Section 8(d), Section 9 Districts (CR), Section 14F4 |
| Freestanding Sign | 10 feet | — | — | Cannot project into setbacks (per Schedule of Site Regulations and site plan review). | Subject to site plan (generally one per principal entrance) | At main entrance or street frontage. | — | Appendix A Zoning, Section 7(8)(l), Section 8(d) |

### Commercial Limited (CL), Shopping Center (SC)

| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Ordinance Citation |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Wall Sign | — | — | — | Cannot project into setbacks; subject to review in building/site plan approval process. | Subject to Town Council/site plan approval, by use or entrance. | On building face, facing street or main entrance, within property boundaries. | — | Appendix A Zoning, Section 8(d), Section 11, Section 14F4 |
| Freestanding Sign | — | — | — | No sign may be placed in a required perimeter setback or buffer area. | Typically one per street frontage or main entry, subject to Town Council approval. | At main entrance/entry drive(s) to shopping center or business. | — | Appendix A Zoning, Section 8(d), Section 11 Site Plan/Building Plan Requirements |

### Industrial (I), Planned Commerce Center (PCC)

| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Ordinance Citation |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Wall Sign | — | — | — | Within property line, no projection into setbacks. | One per building or use, subject to site plan approval. | On building face; not protruding into right-of-way/setback. | — | Appendix A Zoning, Section 12, Section 12A, Section 7(8)(l) |
| Freestanding Identification Sign (Single Building) | 10 feet; not above first floor level | 50 sq ft per face | — | On property, not projecting into required yards/perimeter buffer. | One per freestanding building. | Within 100 feet of building, within property boundary. | — | Appendix A Zoning, Section 12A(10)(a), 19A(15)(b) |
| Freestanding Entry Sign (PCC or Park entrances) | 10 feet | 200 sq ft per face (pair of signs allowed per entry) | — | At access entries; must not encroach in buffer/setback; subject to site plan. | One pair of freestanding signs per entry access road. | Both sides of access road entries to PCC, within property boundary at entrances. | — | Appendix A Zoning, Section 12A(10)(b), 19A(15)(c) |
| Directional/Internal Traffic Control Sign | 6 feet | 10 sq ft | — | Internal use only; no setback restriction (for traffic control signs only). | As needed for traffic safety, as approved. | Internal to park/PCC within property; for traffic control only. | — | Appendix A Zoning, Section 12A(10)(e)(1), 19A(15)(f)(i) |
| Construction Sign | — | 16 sq ft | — | On property; must not block sight visibility or encroach in setbacks. | One per project site. | On-site during actual building or construction period. | — | Appendix A Zoning, Section 12A(10)(e)(2), 19A(15)(f)(ii) |
| Real Estate Sign | — | 8 sq ft | — | Not in right-of-way/setback; not on buffer. | One per parcel. | On property for rent, sale, or lease. | — | Appendix A Zoning, Section 12A(10)(e)(3), 19A(15)(f)(iii) |

## Prohibited signs in Mangonia Park

- Any use not specifically permitted in the zone is prohibited unless expressly approved by special exception.
- No building, structure, or use of land shall be erected, constructed, reconstructed, moved, or structurally altered except in conformity with all of the regulations specified for the district in which it is located.
- No building or other structure shall be erected or altered to exceed the height or bulk, to accommodate more facilities, to occupy a greater percentage of lot area, to have narrower or smaller yards or open space, or in any other manner contrary to the ordinance.
- No part of a required yard, open space, or off-street parking/loading space for any building may be included as part of a yard, open space, or parking/loading space for any other building.
- No yard or lot existing at the time of the ordinance shall be reduced in dimension or area below the minimum requirements.
- No building or premise shall be used, or allowed to be used, for purposes not in conformity with the zoning regulations.
- No use may emit odors, gases, dust, smoke, vibration, or noise, nor may anything be constructed or maintained that constitutes an eye-sore or nuisance to adjacent properties or the community.
- It is unlawful for the owner, lessee, or person in control of residential property or a dwelling to allow its use by a larger number of persons than zoned/designated for, or to hold continuing meetings or entertainment for persons beyond that number.
- No home occupation may display signs advertising the accessory use of the premises.
- No goods may be sold on the building site, and no stock in trade may be stored or delivered to the site for home occupations.
- No vehicle, trailer, or recreational vehicle may be occupied or used for business, living, sleeping, or housekeeping purposes in any residential or commercial zone without express permission of the Town Council.
- No flashing signs are permitted.
- No signs shall be placed on the perimeter of Planned Commerce Center (PCC) or Planned Industrial Park (PIP) properties other than as specifically allowed or approved by Town Council.
- No yard, lot, or off-street parking area shall be used collectively in a way that violates minimum requirements for each use.
- No conveyance other than a passenger motor vehicle may be parked overnight in any yard except as specified.
- No vehicle may be parked in front yards for long-term repair.
- Any unauthorized change to the Official Zoning Map is a violation and punishable.
- All uses in Industrial Districts must comply with performance standards regarding fire hazard, emission, noise, odor, glare, etc.
- No changes may be made to Official Zoning Map or matter thereon except in conformity with the ordinance.

## Signs exempt from permit in Mangonia Park

- Entertainment of bona fide guests of the owner, lessee, or person in legal possession or control of a dwelling unit is not prohibited, provided it is not a continuing or regular event.
- The following are exempt from the on-site dispensing of controlled substances prohibition at health care facilities: direct administration to a patient during treatment; administration in hospitals, nursing homes, ambulatory surgical centers, hospices, intermediate care facilities; emergency room administration; dispensing to persons under 16; and a one-time 72-hour emergency resupply.
- Home hobbies are not restricted by the ordinance.

## Sign plan & submission notes

- All signs shall be subject to approval of the Town Council with recommendation of the Planning and Zoning Board and in accordance with the ordinances of the Town.
- Site plans must show location and dimensions of all signs and exterior lighting to be placed on a site.
- Outline specifications of building plans must include size, type, and location of on-site signs and proposed exterior lighting.
- In Planned Commerce Center (PCC), all signs must be constructed in accordance with a sign plan prepared by applicant and approved by Town Council prior to erection. No flashing signs are permitted; only indirect lighting is allowed.
- In Planned Industrial Park (PIP), each sign must be constructed in accordance with a sign plan prepared by the applicant and approved by Town Council prior to erection. No flashing sign is permitted; only indirect lighting.
- Master Site Plan approval is required for Planned Commerce Centers (PCCs), and the Master Site Plan may be prepared in conjunction with the Master Landscape Plan.
- All applications for PCC zoning approval shall identify that two or more professionals (such as planner, architect, engineer, etc.) were utilized in the design or planning process.
- All planned unit development (PUD) applications must be accompanied by a Proposed Master Land Use Plan. Final Master Land Use Plan approval is required before any residential or commercial construction permit is issued, although certain temporary/permanent structures may be permitted after plan approval.
- All master, preliminary, and final plans for Planned Industrial Parks (PIP) must adhere to the Land Development Regulations and must have a master site plan (including signage details) submitted.
- Any change to an approved detailed site plan requires prior approval of Town Council.
- Site plan submissions must include landscape plan and sign locations/specifications.
- In Shopping Center Districts, site and building plans (including sign details) must be approved by Town Council before permits may be issued.
- All subdivision plats, rezonings, and special exceptions require plans that may include or reference sign specifications as part of site plan documentation.

## Full detail

This page publishes an overview of every zoning district plus a sample of 3 districts in full. Complete zone-by-zone requirements for all 9 zoning districts in Mangonia Park — every sign type, every field — are available with a free PermitPal account: https://app.permitpal.io/?address=Mangonia+Park+FL&override=true&utm_source=landing&utm_medium=city-page&utm_campaign=city-mangonia-park

---

PermitPal — AI sign code research. Full HTML page: https://permitpal.io/sign-regulations/florida/mangonia-park
