## At a glance

Painted Post, New York regulates 29 sign types across 14 zoning districts. Directional Sign (On-site)s in the General Regulations For All Zones zoning district are capped at 4 ft above grade tall and 4 sq ft per face, with a Minimum 5 ft from any lot line setback (Sec. §130-81(D)(3)(a)-(c), Article X - Supplemental Regulations Page 166). Most commercial signs in Painted Post require a permit.

## Sign rules by zoning district (14 zones)

| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
| --- | --- | --- | --- | --- |
| General Regulations For All Zones | 19 | 5 ft | 32 sq ft | — |
| Town Center (TC), Multi-Use District (MU) | 9 | Not higher than 15 ft on a multi-story building; not higher than the face of a single-story building | 50 sq ft per wall sign (absolute per-sign cap) | — |
| Business 1 – Community Service (B1) | 7 | Not higher than 15 ft on a multi-story building; not higher than the face of a single-story building | 50 sq ft per wall sign (absolute per-sign cap) | — |
| Business 2 – Office/Commercial District (B2) | 6 | Not higher than 15 ft on a multi-story building; not higher than the face of a single-story building | 50 sq ft per wall sign (absolute per-sign cap) | — |
| Business 3 – Neighborhood Services District (B3) | 7 | Not higher than 15 ft on a multi-story building; not higher than the face of a single-story building | 50 sq ft per wall sign (absolute per-sign cap) | — |
| Regional Service (RS), Industrial 1 (I-1), Industrial 2 (I-2) | 3 | Shall not be located higher than or exceeding 15 ft, or project above the first floor of the structure (whichever is lower) | Per individual wall sign: 155 sq ft maximum | — |
| Rural District (RD) | 6 | Shall not be located higher than or exceeding 10 ft; or project above the first floor of the structure (whichever is lower) | 35 sq ft | — |
| Low Density Residence (R-12.5), Medium Density Residence (R-10), High Density Residence (R-7.5, R-7.2) | 6 | Top of sign or bracket not higher than 14 ft from lowest natural or manmade grade | 20 sq ft | — |

_6 additional zoning districts are covered in PermitPal (free account)._

## Zone-by-zone sign requirements (sample of 3 of 14 zones)

### General Regulations For All Zones

| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Ordinance Citation |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| On-site Real Estate Sign (Residential Uses) | 4 ft | 8 sq ft per sign face | — | — | — | On-site at property being offered for sale/lease | — | §130-81(C)(1), Article X - Supplemental Regulations Page 163 |
| On-site Real Estate Sign (Business and Industrial Uses) | 5 ft | 30 sq ft per sign face | — | — | — | On-site at property being offered for sale/lease | — | §130-81(C)(1), Article X - Supplemental Regulations Page 163 |
| Political Sign | 4 ft above grade | 6 sq ft | — | Minimum 5 ft from any lot line | — | Any district | — | §130-81(C)(5), Article X - Supplemental Regulations Page 164 |
| Permanent Subdivision Identification Sign | 5 ft | 20 sq ft per sign face | — | — | 1 per subdivision | One on-site identification sign per subdivision | — | §130-81(C)(11), Article X - Supplemental Regulations Page 165 |
| Civic/Religious/Educational/Institutional/Social/Membership Club Sign | 5 ft | 20 sq ft per sign face | — | — | 1 per facility | On-site at facility | — | §130-81(C)(12), Article X - Supplemental Regulations Page 165 |
| Apartment/Mobile Home Park Principal Identification Sign - Option 1 | 5 ft | 20 sq ft per sign face | — | — | 1 | On-site at apartment complex or manufactured/mobile home park | — | §130-81(D)(1)(a), Article X - Supplemental Regulations Page 165 |
| Apartment/Mobile Home Park Principal Identification Sign - Option 2 (Second Sign via Special Use Permit) | 5 ft | 20 sq ft per sign face | — | — | 1 additional (with SUP) | On-site at apartment complex or manufactured/mobile home park | — | §130-81(D)(1)(b), Article X - Supplemental Regulations Page 165 |
| Directional Sign (On-site) | 4 ft above grade | 4 sq ft per face | — | Minimum 5 ft from any lot line | Max 2 per site | On-site indicating entrances/exits | — | §130-81(D)(3)(a)-(c), Article X - Supplemental Regulations Page 166 |

### Town Center (TC), Multi-Use District (MU)

| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Ordinance Citation |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Wall Sign | Not higher than 15 ft on a multi-story building; not higher than the face of a single-story building | 50 sq ft per wall sign (absolute per-sign cap) | — | General: minimum 10 ft from any lot line for all signs unless otherwise specified (§130-81(B)(10)) | Max 2 per business (one per wall) | On building façade owned or rented by the business; one per wall | — | Table 130-81-1 (Wall row, TC/MU columns), Article X - Supplemental Regulations Pages 158–160; §130-81(B)(1)(h), (11), (15) |
| Freestanding Sign | 8 ft | — | 4 ft | Minimum 10 ft from any lot line unless otherwise specified (§130-81(B)(10)) | Max 1 freestanding sign per principal business under §130-81(B)(3)(a) | On same lot as business | — | Table 130-81-1 (Freestanding row, TC/MU columns), Article X - Supplemental Regulations Pages 158–160; §130-81(B)(11), (15) |
| Window Signs | — | Per window sign: display area ≤ 30% of the contiguous window area | — | — | Max 4 | On windows of the business | — | Table 130-81-1 (Window row, TC/MU columns), Article X - Supplemental Regulations Page 158–160; §130-81(B)(3)(c) |
| Permanent Changeable Message/Marquee (Wall - Option 1) | Subject to wall sign height restrictions (≤15 ft or face of single-story) | No one wall sign may exceed 50 sq ft | — | — | — | On building wall | — | Table 130-81-1 (Permanent Changeable Message/Marquee row, TC/MU columns), Article X - Supplemental Regulations Pages 158–160 |
| Permanent Changeable Message/Marquee (Freestanding - Option 2) | 5 ft | — | 6 ft | Minimum 10 ft from any lot line unless otherwise specified (§130-81(B)(10)) | — | On same lot as business | — | Table 130-81-1 (Permanent Changeable Message/Marquee row, TC/MU columns), Article X - Supplemental Regulations Pages 158–160 |
| Projecting Sign | Top of sign or bracket not higher than 14 ft from lowest natural or manmade grade | 6 sq ft per face | — | — | 1 per business | Projecting from building façade | — | Table 130-81-1 (Projecting row, TC/MU columns), Article X - Supplemental Regulations Pages 158–160; §130-81(B)(13) |
| A-Frame/Sandwich Board | — | 8 sq ft per face | — | Minimum 5 ft from road/ROW | 1 per business | On-site on private property (not in public right-of-way) | — | Table 130-81-1 (A-Frame/Sandwich Board row, TC/MU columns), Article X - Supplemental Regulations Pages 159–160 |
| Special Event Signs (zone-acknowledged) | 5 ft | 20 sq ft per face | — | — | — | On-site during qualifying events | — | Table 130-81-1 (Special Sales and Special Event row, TC/MU columns) referencing §130-81(C)(6), Article X - Supplemental Regulations Page 160, 164–165 |

### Business 1 – Community Service (B1)

| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Ordinance Citation |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Wall Sign | Not higher than 15 ft on a multi-story building; not higher than the face of a single-story building | 50 sq ft per wall sign (absolute per-sign cap) | — | Minimum 10 ft from any lot line unless otherwise specified | Max 2 per business (one per wall) | On building façade owned or rented by the business; one per wall | — | Table 130-81-1 (Wall row, B1 column within TC–MU group), Article X - Supplemental Regulations Pages 158–160; §130-81(B)(1)(h), (11) |
| Freestanding Sign | 8 ft | — | 4 ft | Minimum 10 ft from any lot line (§130-81(B)(10)) | Max 1 freestanding sign per principal business under §130-81(B)(3)(a) | On same lot as business | — | Table 130-81-1 (Freestanding row, B1 within TC–MU group), Article X - Supplemental Regulations Pages 158–160 |
| Window Signs | — | Per window sign: display area ≤ 30% of the contiguous window area | — | — | Max 4 | On windows of the business | — | Table 130-81-1 (Window row, B1 within TC–MU group), Article X - Supplemental Regulations Pages 158–160; §130-81(B)(3)(c) |
| Permanent Changeable Message/Marquee (Wall - Option 1) | Subject to wall sign height restrictions (≤15 ft or face of single-story) | No one wall sign may exceed 50 sq ft | — | — | — | On building wall | — | Table 130-81-1 (Permanent Changeable Message/Marquee row, B1 within TC–MU group), Article X - Supplemental Regulations Pages 158–160 |
| Permanent Changeable Message/Marquee (Freestanding - Option 2) | 5 ft | — | 6 ft | Minimum 10 ft from any lot line (§130-81(B)(10)) | — | On same lot as business | — | Table 130-81-1 (Permanent Changeable Message/Marquee row, B1 within TC–MU group), Article X - Supplemental Regulations Pages 158–160 |
| Projecting Sign | Top of sign or bracket not higher than 14 ft from lowest natural or manmade grade | 6 sq ft per face | — | — | 1 per business | Projecting from building façade | — | Table 130-81-1 (Projecting row, B1 within TC–MU group), Article X - Supplemental Regulations Pages 158–160 |
| A-Frame/Sandwich Board | — | 16 sq ft per face | — | Minimum 15 ft from road | 1 per business | On-site on private property (not in public right-of-way) | — | Table 130-81-1 (A-Frame/Sandwich Board row, B1 column and continuation on Page 159–160) |

## Prohibited signs in Painted Post

- Free-standing high rise (pole) signs exceeding 12 feet in height in any district except RS, and exceeding 16 feet in RS, I-1, and I-2, are prohibited.
- Translucent canopy signs (plastic or similar material) with or without backlighting are prohibited.
- Roof signs are prohibited.
- Billboards are prohibited.
- Fuel pump advertisement signs are prohibited.
- Temporary advertisement signs are prohibited.
- Portable changeable message signs are prohibited.
- Wall signs located higher than 15 feet, or that project above the first floor of the structure (whichever is lower), are prohibited.
- Flashing signs and signs with moving parts are prohibited, except public service signs (such as time and temperature) approved by the Code Enforcement Officer.
- Any sign not specifically listed as allowed in the Chapter is prohibited.
- No sign may be erected, placed, maintained, or extended into the right-of-way of any street or highway, except traffic signs placed by public agencies.
- No sign may be erected, placed, or maintained at or near an intersection in a manner that causes a traffic hazard, interferes with or obstructs the view of, or is confused with authorized traffic control devices, or uses words/phrases/symbols (e.g., "stop," "look," "drive-in," "left") that mislead or confuse traffic.
- Sign illumination shall not be intermittent/flashing or of varying intensity, and may not produce glare beyond property lines.
- No sign is permitted over a public driveway or thoroughfare (traffic control devices per 17 NYCRR Part 200 are exempt).
- Signs under which a pedestrian walkway or driveway passes must provide a minimum vertical clearance of 10 feet.
- All signs must be set back at least 10 feet from any lot line unless otherwise specified by county, state, or federal regulations, or where the right-of-way is wider (case-by-case).
- Any permitted sign that does not display a message for more than 30 days must be removed.

## Signs exempt from permit in Painted Post

- On-site real estate signs allowed without a building permit in any district (residential: max 8 sq ft, max 4 ft height; business/industrial: max 30 sq ft, max 5 ft height).
- Construction signs denoting architect/engineer/contractor on the premises allowed without a building permit (remove within 30 days of completion; max 32 sq ft; max 5 ft height).
- Signs associated with the sale of seasonal agricultural crops allowed without a building permit.
- Traffic or other municipal signs, legal notices, and temporary or non-advertising signs for government purposes allowed without a building permit.
- Political signs allowed without a building permit (max 6 sq ft; display only within 90 days prior to an election; remove within 1 week after; at least 5 ft from lot line; not more than 4 ft above grade).
- Special event signs (banners; A-frames/T-frames; curb/sidewalk signs; sandwich boards) allowed without a building permit for events such as craft shows, fairs/carnivals, antique car shows, or similar events determined by the Code Enforcement Officer (display up to 3 weeks; remove within 1 week after; max 20 sq ft; max 5 ft height).
- Signs, certificates, and licenses mandated to be on display by law allowed without a building permit.
- Fuel pump price signs no larger than the minimum size required by NYS law allowed without a building permit.
- Nameplate signs for permitted home occupations allowed without a building permit (mounted at business entrance; max 2 sq ft).
- Temporary subdivision signs allowed without a building permit (on-site non-illuminated; max 20 sq ft per face; max 5 ft height; remove within 4 years or when 50% of lots are sold).
- Permanent subdivision identification signs allowed without a building permit (one per subdivision; max 20 sq ft per face; max 5 ft height).
- One on-site sign for civic, religious, educational, institutional, social, membership clubs, and similar facilities allowed without a building permit (max 20 sq ft per face; max 5 ft height).
- Traffic control devices pursuant to 17 NYCRR Part 200 are exempt from the prohibition on signs over a public driveway or thoroughfare.
- Safety signs, road signs, historical markers, and highway directional signs erected by municipal or public agencies are exempt from the sign height and width measurement provisions.

## Sign plan & submission notes

- Signage for General, Business, Light Industrial, and other nonresidential uses is permitted through Site Plan Review approval; signs must comply with Table 130-81-1 and all applicable provisions.
- In any district, signage for apartment complexes or manufactured/mobile home parks is subject to Site Plan Review; a second principal identification sign requires a Special Use Permit.
- Sign height submissions must include the elevation at grade at the sign location as part of the topographic data for site plan consideration.
- Use variance required to allow any sign that is prohibited, illegal, or not specifically permitted; also required for sign heights greater than 16 ft in RS, I-1, and I-2, and greater than 12 ft in non-RS/I-1/I-2 districts.
- Area variance required for sign heights greater than 12 ft but not more than 16 ft in RS/I-1/I-2, greater than 8 ft but not more than 12 ft in non-RS/I-1/I-2, or to exceed dimensional requirements set forth in §130-81.
- All signs other than those exempted are required to obtain building permits.
- No explicit Master Sign Plan requirement is stated in the provided text.

## Full detail

This page publishes an overview of every zoning district plus a sample of 3 districts in full. Complete zone-by-zone requirements for all 14 zoning districts in Painted Post — every sign type, every field — are available with a free PermitPal account: https://app.permitpal.io/?address=Painted+Post+NY&override=true&utm_source=landing&utm_medium=city-page&utm_campaign=city-painted-post

---