## At a glance

Seguin, Texas regulates 29 sign types across 8 zoning districts. Billboard (Expressways & Interstate Highways)s in the General Regulations For All Zones zoning district are capped at 40 ft above street grade tall and 480 sq ft (face, may have 20% embellishments), with a See Sec. 82-118 (distance from various land uses, property lines, overpasses) setback (Sec. Sec. 82-120, Sec. 82-117). Most commercial signs in Seguin require a permit.

## Sign rules by zoning district (8 zones)

| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
| --- | --- | --- | --- | --- |
| General Regulations For All Zones | 13 | 40 ft | 480 sq ft (face, may have 20% embellishments) | — |
| North Austin Street Corridor District | 1 | 15 ft | 100 sq ft | — |
| Corridor Overlay Districts | 2 | 20 ft | 150 sq ft | — |
| IH 10 Corridor Overlay District | 2 | 60 ft | 600 sq ft | — |
| Downtown Historic District | 10 | 48 in | 45 sq ft per primary sign; total per facade = 2 sq ft per 50 sq ft of facade area | — |
| Historic District | 5 | 48 in | 45 sq ft per sign | — |
| SH 46 Corridor Overlay District | 1 | — | — | — |
| Industrial Zoning Districts, Commercial Zoning Districts | 3 | 40 ft | 480 sq ft (plus 20% for embellishments) | — |

## Zone-by-zone sign requirements (sample of 3 of 8 zones)

### General Regulations For All Zones

| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Ordinance Citation |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Pole/Pole-Mounted Sign | 25 ft. | 100 sq. ft. | — | — | — | On private property only, not in or upon any sidewalk, street, or public property. | — | Sec. 82-101 |
| Subdivision Entrance Sign | 20 ft (structure); 30 inches (letter/copy) | — | — | 5 ft from ROW, 10 ft from residential lot | Max 2 per entrance | At subdivision entrance; not to encroach public ROW; not to encroach utility/drainage easement. | — | Sec. 82-111 |
| Electronic Sign (General Location) | — | 32 sq ft (must be within monument sign) | — | — | 1 per lot | Only allowed as part of a monument sign except IH-10 adjacency | — | Sec. 82-110(a)-(j) |
| Electronic Sign (IH-10 Parcels) | 40 ft | 100 sq ft | — | — | 1 per lot | Parcels adjacent to IH-10 | — | Sec. 82-110(b) |
| Billboard (Expressways & Interstate Highways) | 40 ft above street grade | 480 sq ft (face, may have 20% embellishments) | — | See Sec. 82-118 (distance from various land uses, property lines, overpasses) | — | Expressways/Interstate highways | — | Sec. 82-120, Sec. 82-117 |
| Billboard (Arterials >75 sq ft) | 35 ft above adjacent street grade | 200 sq ft | — | See Sec. 82-118 | — | Along arterial streets as designated by city transportation plan | — | Sec. 82-116(b), 82-117(a)(2), 82-120(a)(2) |
| Billboard (Arterials ≤75 sq ft) | 35 ft above adjacent street grade | 75 sq ft | — | See Sec. 82-118 | — | Along arterial streets as designated by city transportation plan | — | Sec. 82-116(b), 82-117(a)(2), 82-120(a)(2) |
| Portable Sign | 8 ft | — | — | 15 ft from property line | — | At least 15 feet inside private property line; not on sidewalks or public ROW. | — | Secs. 82-138, 82-151, 82-154, 82-155 |

### Downtown Historic District

| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Ordinance Citation |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Primary Sign | — | 45 sq ft per primary sign; total per facade = 2 sq ft per 50 sq ft of facade area | — | — | Max one primary per street facade, one at rear if public entrance | One per street facade; one additional at rear public entrance | — | Sec. 82-169(1)-(2), 82-167(2)-(4), 82-170 |
| Hung Perpendicular Sign | — | 45 sq ft | — | — | — | Hung perpendicular to building as primary sign | — | Sec. 82-169(3), 82-170 |
| Secondary Sign | — | — | — | — | 3 per business | Can be hung from awning, as window sign, or building directory, etc. | — | Sec. 82-169(4) |
| Sandwich Board Sign | 48 in | — | — | — | — | Outside business when open and properly anchored; must keep 4 ft clear on sidewalk | — | Sec. 82-167(6) |
| Awning/Canopy Sign | — | — | — | — | — | Painted/applied flat to awning/canopy surface | — | Sec. 82-167(7) |
| Permanent Window Sign | 12 in characters/words | 25% of window area | — | — | — | Painted on glass windows | — | Sec. 82-167(8) |
| Temporary Sign | — | Banners max 30 sq ft | — | — | — | Painted on windows/exterior, banners, pennant flags | — | Sec. 82-168 |
| Electronic Window Sign | — | 6 sq ft per sign | — | — | 2 per business | Inside window display | — | Sec. 82-174(b)-(e) |

### Historic District

| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Ordinance Citation |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Wall Sign | — | 45 sq ft per sign | — | — | 1 per street facade, 1 at rear if public entrance | Affixed to building facade | — | Sec. 82-167, Sec. 82-169 |
| Window Sign | 12 in (words/characters) | 25% of window area | — | — | — | Painted on windows | — | Sec. 82-167(8), 82-170 |
| Sandwich Board Sign | 48 in | — | — | — | — | Outside business when open | — | Sec. 82-167(6) |
| Awning/Canopy Sign | — | — | — | — | — | Flat on awning/canopy | — | Sec. 82-167(7) |
| Temporary Sign | — | Banners max 30 sq ft | — | — | — | On glass windows, banners, pennants, etc. | — | Sec. 82-168 |

## Prohibited signs in Seguin

- No sign shall be situated in a manner that interferes with or obstructs windows, doors, or other means of exit from a building.
- No signs shall be supported on or attached to any fire escape, door, or window casing.
- No signs shall be erected on or over public property in a manner which interferes with any fire hydrant, traffic light, fire alarm box, or streetlight.
- Billboards and commercial signs shall not be erected where, because of traffic conditions, fire or explosion hazards, the sign would imperil public safety or hamper the functions of the fire department.
- The use of staples, wires, and wood plugs in erecting signs is prohibited.
- No permanent signs shall be erected so as to overhang any street, alley, or plaza. Overhanging is only permitted over sidewalks and spaces not intended for vehicular ingress/egress.
- No sign shall be erected, maintained, or painted upon any tree, rock, or other natural feature.
- No pole, post, or standard used to support any sign or floodlight shall be set in or upon any sidewalk, street, or other public property.
- All electric signs must comply with all applicable electrical codes and be subject to inspection by the building official.
- All signs must be kept in good repair, including legibility of copy/print, absence of tears/defacements, and rust-free, structurally sound frames.
- Signs which do not advertise on-premises businesses are considered abandoned and must be removed if they do not comply with billboard requirements.
- All billboards must be located in industrial and commercial zoning districts only.
- No billboard or any part thereof shall be located on or above any public property or street right-of-way, unless approved by city ordinance.
- Electronic signs shall not be used as billboard signs.
- No portable sign, electric or nonelectric, shall be placed on any sidewalk, street, public thoroughfare, or public property. Must be at least 15 feet inside private property lines.
- No off-premises portable signs are permitted in the city.
- No portable sign permit if the top of the sign (including decorative trim) is more than eight feet above the ground.
- No portable sign permit if the sign has any type of rotating beacon electric light, includes animation, or is missing bulbs exposing sockets.
- Within the downtown historic district: no sign displayed from parapet or roof; no interior illuminated signs on exterior; no advertising on planters, trash receptacles, benches, or other street amenities except donor plaques; no signage on more than two facades; permanent signs not of core-plast or banner material.
- Permanent subdivision entrance signs shall not encroach into public right-of-way or utility/drainage easements; not consist of more than two usable sides; and must be constructed of compatible materials.
- Billboards shall not be positioned to obscure or interfere with a traffic sign, signal, or driver’s view of traffic.
- Billboards shall not be illuminated in a manner that interferes with or obscures an official traffic sign or device, or cause glare impeding a driver's vision.
- No new billboard signage shall be permitted along the SH 46 corridor overlay district south of IH 10 right-of-way.
- Pole-mounted nonlettered physical representative signs (such as pole-mounted automobiles, boats, airplanes) are prohibited.
- Portable signs may not include animation or rotating beacons.
- Balloon, bunting, banner, flashing or blinking, portable, and roof signs are prohibited in corridor overlay districts.

## Signs exempt from permit in Seguin

- Temporary signs may be constructed of cloth or wallboard and may be staked or affixed to a structure (with certain additional requirements for banner signs and safety).
- Unframed cloth banner signs may project over a public street subject to approval by the building official and safety certification by the erector.
- Temporary real estate and space-for-lease signs may exceed 30-day limit as long as maintained in good repair (within historic district).
- Temporary signs (such as banners and pennant flags) related to special events, promotions or holidays, are excluded from calculations of maximum allowable sign area per building (within historic district).
- Within the downtown historic district, sandwich signs are exempted from permit and licensed contractor requirements, provided they are properly anchored and only displayed when the business is open.
- Permanent signage with area of 15 square feet or less is exempt from permit and variance requirements in historic district.
- Murals in historic district are exempt from maximum area if permitted through required process.
- Subdivision entrance sign structures that do not contain copy/letters used for the name of the subdivision will require separate permits (i.e., subdivision entrance signs proper are exempt from this additional permit if they only contain the name).

## Sign plan & submission notes

- Structural plans with calculations sealed by a licensed professional engineer for subdivision identification signs must be provided to planning and codes department for record keeping.
- As-built drawings and a letter of concurrence from a licensed professional engineer are required at final review for subdivision entrance signs.
- Historic district: All requests for a variance from sign requirements must be submitted in writing along with a permit application, and applicants may appeal refusals (tiered review process: Main Street director, design review committee, zoning board of adjustments).
- Within the historic district, murals and most signs require a permit and (if applicable) a variance through a specified approval process.
- No explicit general 'master sign plan' requirement was found; however, subdivision entrance signs require engineer-sealed structural plans, as-builts, and record filings, analogous to a sign plan for such signage.

## Full detail

This page publishes an overview of every zoning district plus a sample of 3 districts in full. Complete zone-by-zone requirements for all 8 zoning districts in Seguin — every sign type, every field — are available with a free PermitPal account: https://app.permitpal.io/?address=Seguin+TX&override=true&utm_source=landing&utm_medium=city-page&utm_campaign=city-seguin

---