Sign Regulations in Globe, Arizona

Globe, Arizona has specific sign regulations covering 17 sign types across 8 zoning districts. Regulated sign types include Traffic Directional Sign, Freestanding Sign, Wall/Window Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Sign Regulation Overview for Globe, Arizona

Sample Sign Requirements in Globe

Sign TypeMax HeightMax AreaSetback
Freestanding Sign6 sq. ft.5′
Freestanding/Monument Sign (Subdivision/Manufactured Home Subdivision Entrance)8 ft.32 sq. ft.5' from property lines/easements/ROW
Wall SignSee formula; max 32 sq. ft. on any one street

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for GlobeFull Coverage

Sign Types Covered

17

  • Traffic Directional Sign
  • Freestanding Sign
  • Wall/Window Sign
  • All signs
  • +2 more types

Zoning Districts

8

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Globe

Frequently Asked Questions

Sign height limits in Globe vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Globe, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Globe, regulated sign types include Traffic Directional Sign, Freestanding Sign, Wall/Window Sign, All signs, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Globe, monument signs typically require a 5′ setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Globe are regulated with specific requirements for brightness, animation, and message duration. Globe has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Globe Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Globe, Arizona sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Globe, Arizona Sign Rules at a Glance

Globe, Arizona regulates 17 sign types across 8 zoning districts. Freestanding/Monument Sign (Subdivision/Manufactured Home Subdivision Entrance)s in the R1-6, R1-9, R1-43, R2, MHS, TR, NS, RV zoning district are capped at 8 ft. tall, 32 sq. ft., and 10 ft. wide, with a 5' from property lines/easements/ROW setback (Sec. Sec. 14-13-20(a)(2); Sec. 14-13-18). Most commercial signs in Globe require a permit.

Detailed Sign Ordinance Requirements for Globe, Arizona

Sign Rules by Zoning District in Globe (8 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
R1-6, R1-9, R1-43, R2, MHS, TR, NS, RV58 ft.32 sq. ft.
C-2416 ft.No attached sign shall exceed 100 sq. ft. without Council approval
C-3316 ft.Not to exceed 300 sq. ft. (Council approval required >100 sq. ft.)
Industrial Zones1
Planned Area Development (PAD)1
Historic Preservation District3Minimum 8 ft above sidewalk25% of window area (opaque) or 80% (transparent), per window
General Regulations For All Zones7Residential: 5 ft; Commercial/industrial: 8 ft36 sq. ft.
1 more zone in PermitPal — start free

Zone-by-Zone Sign Requirements in Globe(sample of 3 of 8 zones)

R1-6, R1-9, R1-43, R2, MHS, TR, NS, RV

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Sign6 sq. ft.5′1+, see temporary sign periods5' setback from property lines, easements, or rights-of-wayUnlockSec. 14-13-20(a)(1)a, (b)(1)a, Table Sec. 14-13-20
Freestanding/Monument Sign (Subdivision/Manufactured Home Subdivision Entrance)8 ft.32 sq. ft.10 ft.5' from property lines/easements/ROW1 per arterial (or collector) street frontageAdjacent to subdivision entrance(s)UnlockSec. 14-13-20(a)(2); Sec. 14-13-18
Wall SignSee formula; max 32 sq. ft. on any one streetOn building wallUnlockSec. 14-13-20(b)(2)a
Traffic Directional SignOn siteUnlockSec. 14-13-20(b)(2)c
Freestanding/Monument Sign (Multi-family, more than 8 units)8 ft.32 sq. ft.10 ft.5' from property lines/easements/ROWAdjacent to development entrance(s)UnlockSec. 14-13-20(b)(2)d, cross-ref Sec. 14-13-20(a)(2)

C-2

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall/Window SignNo attached sign shall exceed 100 sq. ft. without Council approvalWall- or window-mounted, on or under an architectural projectionUnlockSec. 14-13-20(d)(1)
Freestanding SignTotal area per above formula5′1 (+1 additional for each excess 300 ft)On siteUnlockSec. 14-13-20(d)(2)
Freestanding Sign (Shopping Center/Multi-tenant)16 ft.See formulaNot less than 300 ft apart1 per arterial street, +1 for frontage over 300 ft, max 2 per frontagePer arterial streetUnlockSec. 14-13-20(j)
Traffic Directional Sign3 ft.On siteUnlockSec. 14-13-20(d)(4)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Nameplate SignAffixed to or near buildingUnlockSec. 14-13-9(b)(1)
Sign 6 sq. ft. or less (not otherwise prohibited)6 sq. ft.See specific district regulationsUnlockSec. 14-13-9(b)(2)
Official Traffic, Fire, Police SignsUnlockSec. 14-13-9(b)(5)
Temporary SignResidential: 5 ft; Commercial/industrial: 8 ftIn residential: max 10 sq. ft.; max 5 ft. height; Commercial/industrial: max 50 sq. ft.; max 8 ft. height.1 additionalUnlockSec. 14-13-9(b)(5)
Directional Sign (Public/Institutional)On siteUnlockSec. 14-13-20(c)(1)a
Traffic Directional SignVaries by district (3 ft. for C-2; 6 ft. for C-3)On siteUnlockSec. 14-13-20(d)(4), (e)(5)
Public/Institutional/Church Civic Organization Sign36 sq. ft.On siteUnlockSec. 14-13-20(c)(2)a-b

PermitPal covers all 8 zoning districts in Globe — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 8 zones for Globe — start free

Prohibited Signs in Globe

  • No sign shall be erected, constructed, enlarged, altered, used, or maintained contrary to any provision of this chapter.
  • Offsite temporary signs are prohibited unless falling under special temporary sign periods.
  • Outlining of a building by means of neon lighting, incandescent lighting, or other exposed artificial lighting is prohibited.
  • Fixed balloons used as signs are prohibited.
  • Signs over 300 square feet in area are prohibited.
  • Billboards are prohibited.
  • Signs which are abandoned for a period of 30 days or greater are prohibited.
  • No exposed incandescent bulbs exceeding 40 watts each, neon or similar tube type illumination exceeding 30 milliamps are permitted.
  • No flashing, blinking, or rotating lights shall be permitted, nor shall the sign contain audible sound or odor.
  • Movement of the sign body or any segment thereof, such as rotating (in excess of five revolutions per minute), moving up and down, or other types of action involving a change in position, is prohibited.
  • No sign or structure shall be erected in such a manner as to interfere with the free use of any fire escape, exit, or standpipe.
  • No sign shall obstruct traffic or the vision of motorists.
  • No detached sign shall be located adjacent to driveways so as to result in a traffic hazard.
  • No person, firm, or corporation shall erect a sign projecting over public property without advance City approval.
  • No sign shall be erected or attached to a vehicle except for standard advertising or identification permanently attached and where the primary use of the vehicle is in the operation of the business, not in advertising stationary on the premises.
  • No sign shall be erected or maintained in the public right-of-way except as provided in this chapter.
  • No sign may be secured with wires or strips of wood which are visible and not an integral part of the sign.
  • Signs must be integrated with building and site development; sign area must not be greater than 25 percent of the area of the wall section.
  • No sign shall be illuminated or designed so as to create a traffic hazard as determined by the traffic engineer.

Exempt Signs in Globe

  • A permit shall not be required for nameplate signs.
  • A permit shall not be required for any sign six square feet or less in area not otherwise prohibited.
  • A permit shall not be required for repainting, unless the sign is within the Historic Preservation District.
  • A permit shall not be required for interior signs not visible from the public right-of-way.
  • A permit shall not be required for temporary signs posted during special temporary sign periods (up to 60 days before elections and removed within 10 days after, and from October 1 to December 31 annually), provided size and height requirements are met.
  • Nothing contained herein shall prevent the erection, construction, and maintenance of official traffic, fire, and police signs, signals, devices, and markings of the State of Arizona and the City of Globe, or other competent public authorities, or the posting of notices required by law.

Sign Plan & Submission Notes for Globe

  • Sign criteria shall be established as part of building/sign plan review process for shopping centers and multi-tenant commercial sites.
  • All signs for shopping centers, office and commercial complexes must meet minimum quality and design standards, likely to be reviewed in a sign plan process.
  • For Planned Area Development (PAD), signs may be governed by sign criteria specified as part of a preliminary development plan approval by the Planning and Zoning Commission and City Council or previous sign package approval by the City.
  • All proposed signs in the Historic Preservation District require review/recommendation by the Historic Preservation Advisory Committee and City Council approval.
  • Any sign over 100 square feet or exceeding 16 feet in height requires City Council approval.
  • Any variances or exceptions to sign requirements must be in accordance with the zoning code (implying possible variance or public meeting process).

Source: municode municipal code