Sign Regulations in Bishop, California

Bishop, California has specific sign regulations covering 12 sign types across 2 zoning districts. Regulated sign types include Awning Sign, Marquee Sign, Projecting Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 7, 2025

Sign Regulation Overview for Bishop, California

Sample Sign Requirements in Bishop

Sign TypeMax HeightMax AreaSetback
Awning Sign8.5 ft. minimum clearance from ground30 sq. ft.No setback required
Marquee Sign8.5 ft. minimum clearance from ground60 sq. ft.No setback required
Projecting Sign8.5 ft. minimum clearance from ground32 sq. ft. (includes both sides)No setback required

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for BishopFull Coverage

Sign Types Covered

12

  • Awning Sign
  • Marquee Sign
  • Projecting Sign
  • Wall Sign
  • +2 more types

Zoning Districts

2

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Bishop

City WebsiteMunicipal Code3 permit application links available

Frequently Asked Questions

Sign height limits in Bishop vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Bishop, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Bishop, regulated sign types include Awning Sign, Marquee Sign, Projecting Sign, Wall Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Bishop vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Bishop are regulated with specific requirements for brightness, animation, and message duration. Bishop has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Bishop Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Bishop, California sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Detailed Sign Ordinance Requirements for Bishop, California

Sign Rules by Zoning District in Bishop (2 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Downtown Bishop Specific Plan area128.5 ft. minimum clearance from ground60 sq. ft.
General Regulations For All Zones1220 ft.60 sq. ft.

Zone-by-Zone Sign Requirements in Bishop

Downtown Bishop Specific Plan area

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Awning Sign8.5 ft. minimum clearance from ground30 sq. ft.No setback requiredMultipleGround floor facade, must not project beyond, above, or below the face of the awningUnlock17.85.040 Table, 17.85.060, 17.85.050.C.4
Marquee Sign8.5 ft. minimum clearance from ground60 sq. ft.No setback required1 per building frontageGround floor facade, no extension above roof or parapet lineUnlock17.85.040 Table
Projecting Sign8.5 ft. minimum clearance from ground32 sq. ft. (includes both sides)May not project further than 6 ft. from the buildingNo setback required1 per business frontageGround floor facade, subject to height limitationsUnlock17.85.040 Table, 17.85.050.C.4
Wall SignNo higher than parapet of the building30 sq. ft.No setback requiredMultipleOn building wall it identifiesUnlock17.85.040 Table, 17.85.040.A.2, 17.85.050.C.4
Neon SignageNo higher than parapet of the building30 sq. ft.N/A1 per business frontageOn buildingUnlock17.85.040 Table, 17.85.060.F.3
Temporary Banner8.5 ft. minimum clearance from ground30 sq. ft.N/A1 per building frontageGround floor facade onlyUnlock17.85.040 Table
Monument Sign5 ft. from ground30 sq. ft.N/A1 per building frontageFreestanding with solid base, on the propertyUnlock17.85.040 Table
Murals as SignageIn consultation with cityIn consultation with cityN/AIn consultation with cityOn buildingUnlock17.85.040 Table

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Awning Sign8.5 ft. minimum clearance from ground30 sq. ft.No setback requiredMultipleGround floor facade, must not project beyond, above, or below the face of the awningUnlock17.85.040 Table
Marquee Sign8.5 ft. minimum clearance from ground60 sq. ft.No setback required1 per building frontageGround floor facade, no extension above roof or parapet lineUnlock17.85.040 Table
Projecting Sign8.5 ft. minimum clearance from ground32 sq. ft. (includes both sides)May not project further than 6 ft. from the buildingNo setback required1 per business frontageGround floor facade, subject to height limitationsUnlock17.85.040 Table; 17.85.050.C.4
Wall SignNo higher than parapet of the building30 sq. ft. each (multiple allowed, subject to aggregate maximum for business)No setback requiredMultipleOn building wall it identifiesUnlock17.85.040 Table; 17.85.040.A.2
Neon SignageNo higher than parapet of the building30 sq. ft.N/A1 per business frontageOn buildingUnlock17.85.040 Table, 17.85.060.F.3
Temporary Banner8.5 ft. minimum clearance from ground30 sq. ft.N/A1 per building frontageGround floor facade onlyUnlock17.85.040 Table
Monument Sign5 ft. from ground30 sq. ft.N/A1 per building frontageFreestanding with solid base, on the propertyUnlock17.85.040 Table
Murals as SignageIn consultation with cityIn consultation with cityN/AIn consultation with cityOn buildingUnlock17.85.040 Table

Illumination rules, size formulas, and permit requirements for every sign type in Bishop are available with a free PermitPal account.

Start free

Prohibited Signs in Bishop

  • All forms of advertising statuary are prohibited in all zones.
  • Moving image signs that blink, flash, shimmer, glitter, rotate, oscillate, move, or give the appearance of such motion are prohibited.
  • Animated signs and commercial mascots are prohibited in all zones.
  • Electronic message signs and centers with electronically controlled rotating messages on a timed schedule for changing copy more than 4 times per 24-hour period are prohibited (excluding electronic changeable message copy signs and traffic control signs).
  • Ground-mounted signs installed or placed in the public right-of-way are prohibited (except government and community signs and commercial directory programs).
  • Highly reflective and fluorescent (day-glow) signs are prohibited.
  • Off-site signs are prohibited.
  • Signs posted on trees, utility poles, traffic signposts, light posts, traffic signals, or any official traffic control device are prohibited (excluding approved decorative streetlight banners).
  • Signs placed or maintained so as to interfere with free ingress to or egress from any door, window, fire escape, or parking lot are prohibited.
  • Signs which simulate or imitate any traffic sign or signal, or which use words, symbols, or characters that interfere with, mislead, or confuse pedestrian or vehicular traffic are prohibited.
  • Signs prohibited by a specific plan, master plan, area plan, or similar land use document adopted by the city council are prohibited.
  • Vehicles used only for general signage, or parked where the primary purpose is to display a commercial message, are prohibited.
  • Reflective and glossy materials are not allowed in sign construction.
  • Plastic signs unable to withstand ultraviolet exposure are not permitted.
  • Signs may not be placed on or project into public rights-of-way unless specifically permitted elsewhere.
  • Feather flags (temporary attention getting devices such as feather flags, sign spinners, or inflatable attention devices) are not permitted.
  • Billboards are not permitted.
  • Abandoned signage (empty sign cabinets and out of business signage) must be removed within 30 days after business closure.

Exempt Signs in Bishop

  • Works of art, including murals, sculptures, and paintings, when not used as a sign or attention getting device, are exempt.
  • Any public purpose/safety sign and any other notice or warning required by federal, state, or local law, regulation, or resolution are exempt.
  • Temporary, noncommercial decorations or displays, and signs or other materials displayed on traditionally accepted civic, patriotic, and/or religious holidays are exempt provided they are maintained safely and attractively.
  • Window signs not exceeding 40% of the total ground floor transparency, with one window sign per business, are exempt. Window signage is not allowed above the ground floor, and no illumination directed at window signs is allowed.
  • Menu display boxes for drive-thru up to an aggregate of 15 square feet, subject to building and electrical codes, are exempt.
  • Vehicle station fuel price signs required by state law (one sign per station not exceeding 12 square feet or as required by law, no information other than required/allowed by law, and not LED or internally illuminated) are exempt.

Sign Plan & Submission Notes for Bishop

  • A sign permit is required prior to installation or display of any sign, except those exempted in Section 17.85.070.
  • Permits for temporary signs may be approved on an annual basis provided the applicant submits a plan for all temporary signs for a 12-month period and the plan is approved by the planning department.
  • For any approval of a sign not conforming strictly to standards, an exception may be granted by the approving authority with written findings, but not for prohibited signs.
  • Design exceptions may not be approved for prohibited signs.
  • Applications for sign permits must be made to the planning department using the provided form.
  • Each business requires a separate sign permit.
  • A permit is required for a change in business name on a sign.

Source: municode municipal code