Sign Regulations in Citrus Heights, California
Citrus Heights, California has specific sign regulations covering 25 sign types across 6 zoning districts. Regulated sign types include Wall Sign, Freestanding Sign, Awning Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 7, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Citrus Heights, California
Sample Sign Requirements in Citrus Heights
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Freestanding Sign | Not listed | Not listed | Minimum 5 ft from public right-of-way, plus 1 ft per foot of height over 5 ft, up to 25 ft, unless zone otherwise specifies. |
| Projecting Sign | Top no higher than lowest of: 14 ft, eave, parapet, or sill of 2nd floor window. Min. 8 ft from bottom to grade. | 9 sf per face | Not listed |
| Awning Sign | Ground/second floor only. At least 1 foot below top of parapet, sill of 2nd floor window, and lowest cornice/roof. | Not listed | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
25
- Wall Sign
- Freestanding Sign
- Awning Sign
- Window Sign
- +2 more types
Zoning Districts
6
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Citrus Heights
Other Cities in California
Frequently Asked Questions
In Citrus Heights, the height limit for Construction Sign in the Any zoning district is 8 ft (Sec. 106.38.035.D.2). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Citrus Heights require a permit. From the submission notes on this page: The Director may refer any sign permit or master sign plan application to the Commission for review/decision, or may require conditions of approval. Run a code check for an exact address to see the permit requirements for that zone.
Citrus Heights's sign code covers 25 sign types, including Wall Sign, Freestanding Sign, Awning Sign, and Window Sign. Most commercial signs need a permit. The ordinance lists 17 exemptions. One of them: Service station price signs required by State law, provided the signs are monument type (structure requires a building permit). The full list is on this page.
In Citrus Heights, Directional/Directory Sign must be set back 5 ft from right-of-way, plus 1 ft per foot over 5 ft, up to 25 ft (Sec. 106.38.070.C). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Citrus Heights's sign ordinance that cover digital, changing, or flashing signs: Certain sign types (e.g., murals, freeway-oriented, electronic message displays, temporary subdivision signs) require special review, findings, or permits beyond a master sign plan. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Citrus Heights Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Citrus Heights, California, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Citrus Heights, California Sign Rules at a Glance
Citrus Heights, California regulates 25 sign types across 6 zoning districts. Construction Signs in the Any zoning district are capped at 8 ft tall and 32 sq ft (Sec. 106.38.035.D.2). Most commercial signs in Citrus Heights require a permit.
Detailed Sign Ordinance Requirements for Citrus Heights, California
Sign Rules by Zoning District in Citrus Heights (6 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 7 | 48 in. | May not exceed 25% of combined ground/second floor window area. | Not listed |
| Residential zoning districts, Residential SPA | 4 | 6 ft (may be increased by 1 ft per extra setback up to 10 ft) | 100 sf for combined freestanding signs | Not listed |
| Commercial zoning districts, Industrial zoning districts, Nonresidential SPA | 7 | AC Zone: 30 ft with 10 ft setback; BP/GC/LC/MP/SC: 5 ft (may be up to 25 ft with extra setback) | Min 25 sf. Max area includes all wall/awning/projecting/suspended/window signs per tenant. See wall sign notes. | Not listed |
| AC zone, BP zone, GC zone, LC zone, MP zone, SC zone | 2 | 30 ft | Not listed | Not listed |
| Sunrise Boulevard/Greenback Lane Special Sign District | 3 | 10 ft (may be increased by 1 ft per extra setback to max of 12 ft) | 100 sf | Not listed |
| Any zoning district | 6 | 8 ft | 50 sf cumulative per lot | Not listed |
Zone-by-Zone Sign Requirements in Citrus Heights(sample of 3 of 6 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | Not listed | Not listed | Not listed | Not listed | May be located on any primary or secondary structure frontage. Cannot project more than 18 inches from the surface to which attached. Not to interfere with doors or windows, nor cover prominent architectural features. | Not listed | Unlock | 106.38.050, 106.38.070.L |
| Freestanding Sign | Not listed | Not listed | Not listed | Minimum 5 ft from public right-of-way, plus 1 ft per foot of height over 5 ft, up to 25 ft, unless zone otherwise specifies. | 1 per street frontage <300 ft; plus 1 per additional 300 ft frontage or fraction thereof | On the same site as the subject; cannot project over public property or obstruct traffic sight lines. | Not listed | Unlock | 106.38.070.E |
| Projecting Sign | Top no higher than lowest of: 14 ft, eave, parapet, or sill of 2nd floor window. Min. 8 ft from bottom to grade. | 9 sf per face | Not listed | Not listed | Not listed | No more than 36 in. projection over sidewalk; larger projections over private property may be approved. Requires Encroachment Permit for public ROW projection. | Not listed | Unlock | 106.38.070.I |
| Awning Sign | Ground/second floor only. At least 1 foot below top of parapet, sill of 2nd floor window, and lowest cornice/roof. | Not listed | Not listed | Not listed | Not listed | Ground level or second floor facade awnings. | Not listed | Unlock | 106.38.070.B |
| Window Sign | Not listed | May not exceed 25% of combined ground/second floor window area. | Not listed | Not listed | Not listed | On ground or 2nd floor window; not higher. | Not listed | Unlock | 106.38.070.M |
| A-board/Portable Sidewalk Sign | 48 in. | Not listed | 30 in. | Not listed | 1 per street frontage | Private property inside business street frontage within commercial/industrial zones only where owner has used all permanent sign allowances and entry is 150 ft+ from primary street. | Not listed | Unlock | 106.38.070.A |
| Directional/Directory Sign | Not listed | 10 sf (Director may approve more for special sites) | Not listed | 5 ft from ROW, plus 1 ft per foot over 5 ft, up to 25 ft. | See additional requirements | Setback min. 5 ft from public right-of-way, plus 1 ft per ft of height over 5 ft (max 25 ft). Cannot project over public property or block traffic sight. | Not listed | Unlock | 106.38.070.C |
Commercial zoning districts, Industrial zoning districts, Nonresidential SPA
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | Max: At least 1 foot below top of parapet, sill of 2nd floor window, and/or lowest cornice/roof overhang | Min 25 sf. Max area includes all wall/awning/projecting/suspended/window signs per tenant. See wall sign notes. | Not listed | Not listed | Not listed | Ground or 2nd floor building facade only. | Not listed | Unlock | 106.38.060.C (Table 3-12), 106.38.070.B |
| Freestanding Sign | AC Zone: 30 ft with 10 ft setback; BP/GC/LC/MP/SC: 5 ft (may be up to 25 ft with extra setback) | Not listed | Not listed | See above; 5 ft (may go larger with setback), AC is 10 ft for 30 ft height. | Not listed | On parcel; see setbacks | Not listed | Unlock | 106.38.060.C (Table 3-12), Section Notes |
| Wall Sign | At least 1 ft below top of parapet, 2nd floor window sill, or lowest cornice/roof overhang. | Not listed | Not listed | Not listed | Not listed | On primary or secondary structure frontage. | Not listed | Unlock | 106.38.060.C (Table 3-12) |
| Projecting or Suspended Sign | Below eave/canopy, 8 ft min clearance for suspended. Projecting: Top not above lowest of 14 ft, eave, 2nd floor sill, parapet. | Not listed | Not listed | Not listed | Not listed | May project up to 36 in over sidewalk; suspended below eave/canopy. | Not listed | Unlock | 106.38.060.C (Table 3-12), 106.38.070.I |
| Window Sign | Not listed | 25% of ground/second floor window area | Not listed | Not listed | Not listed | Ground or second floor windows. | Not listed | Unlock | 106.38.070.M |
| Temporary/Portable Sign | Not listed | Not listed | Not listed | Not listed | Not listed | See 106.38.070.I & 106.38.070.K for specifics. | Not listed | Unlock | 106.38.060.C Table 3-12, 106.38.070.K |
| Directory Sign | Not listed | For sites with 4+ tenants, extra freestanding identification sign of 0.25 sf per linear ft of total primary structure frontage up to 100 sf max. | Not listed | Not listed | 1 extra for sites with 4+ tenants | Freestanding sign on site with 4+ tenants. | Not listed | Unlock | 106.38.060.C Table 3-12 |
Any zoning district
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Real Estate Sign (Developed/Improved Property, Commercial, Industrial, Multi-Family, Residential or Nonresidential SPA) | Not listed | 16 sf (10 ft setback); 24 sf (15 ft setback); 32 sf (25 ft setback) | Not listed | See sign area/setback table | Not listed | On developed/improved property, not in public or private ROW. | Not listed | Unlock | 106.38.035.D.1 |
| Real Estate Sign (Undeveloped/Unimproved Property) | Not listed | 24 sf | Not listed | 25 ft minimum setback from right-of-way | Not listed | On undeveloped/unimproved property | Not listed | Unlock | 106.38.035.D.1 |
| Construction Sign | 8 ft | 32 sf | Not listed | Not listed | 1 per site | On site only, not allowed if on-site subdivision sign is approved | Not listed | Unlock | 106.38.035.D.2 |
| Noncommercial Sign | 6 ft | 50 sf cumulative per lot | Not listed | 5 ft from property line | Not listed | On private property with owner's consent, not within 5 ft of property line, not within 15 ft of hydrants/signals, not in ROW. | Not listed | Unlock | 106.38.035.D.3 |
| Directional/Directory Sign (On-site) | Not listed | 10 sf (Director may approve more) | Not listed | 5 ft from ROW, plus 1 ft per foot of height over 5 ft (max 25 ft) | See requirements | On-site, setbacks per 106.38.070.C | Not listed | Unlock | 106.38.070.C |
| Electronic Message Display Sign | Not listed | Up to 50% of monument sign area | Not listed | Not listed | 1 per site | Freestanding sign in commercial or residential zones. Residential require 100 ft min from nearest residential building. | Not listed | Unlock | 106.38.070.D |
PermitPal covers all 6 zoning districts in Citrus Heights. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Citrus Heights
- All signs not expressly allowed by this Chapter are prohibited unless allowed through an Exception to Sign Regulations application.
- Abandoned signs are prohibited.
- Animated, moving, variable intensity, blinking, or flashing signs, or signs that emit a varying intensity of light or color are prohibited, except for specific allowable electronic message displays for time and temperature, barber poles, and electronic message boards when permitted.
- Off-site signs (such as billboards and signs on vehicles parked for longer than necessary for delivery/pick-up), except as specifically allowed, are prohibited.
- Obscene signs as defined by State law are prohibited.
- Pole signs are prohibited.
- Roof signs are prohibited.
- Signs that simulate, in color, size, or design, any traffic control sign or signal, or that use words/symbols/characters to interfere with, mislead, or confuse pedestrian or vehicular traffic are prohibited.
- Signs in the form or shape of a directional arrow, or displaying a directional arrow, except as approved or required for safety and convenience, are prohibited.
- Signs painted on, attached to, or suspended from vehicles or movable objects parked or located to be visible from the public right-of-way longer than necessary for legitimate delivery/pick-up are prohibited, except for signs that are smaller than a single door panel affixed to vehicles.
- Signs marked on or affixed to rocks, trees, or other natural features are prohibited.
- Signs placed within a public right-of-way are prohibited, except as specifically provided.
- Temporary and portable signs are prohibited, except as specifically allowed. This includes balloons, other inflatable devices, flags (except official flags), and pennants/streamers (except as allowed for events or specifically permitted types).
- Individual letters mounted on an exposed electrical raceway (not directly on a building wall), unless the raceway is an integral design component determined by the Director, are prohibited.
Exempt Signs in Citrus Heights
- Modifications to sign copy on conforming signs, or changes to the face or copy of a conforming changeable copy sign.
- Nonstructural modifications to the face or copy of an existing conforming sign installed in compliance with a master sign plan, provided modifications are consistent with the plan.
- Normal maintenance of conforming signs.
- Street identification and house identification signs not exceeding one square foot.
- Open, closed, and hours of operation signs not exceeding two square feet.
- Real estate signs in compliance with requirements and state law.
- Construction identification signs meeting specified limitations.
- Noncommercial signs meeting area, height, illumination, setback, and other requirements.
- Governmental signs installed by Federal, State, City, County, or local agencies (emergency, safety, traffic, legal notices, public facility location, official communications, etc.).
- Street address numbers not exceeding 12 inches in height.
- Flags of national, State, or local governments, or recognized religious, fraternal, or public service agencies meeting size and placement restrictions.
- Symbols, pictures, patterns, and illumination approved by the City as architectural ornamentation or decoration.
- Artistic banners without advertising, as approved by the Director.
- Historical markers, memorials, building cornerstones, and date-constructed stones placed by non-profit organizations.
- Service station price signs required by State law, provided the signs are monument type (structure requires a building permit).
- Window signs in compliance with the City's window sign section.
- Traffic control signs on private property as required by the City or approved by the City Engineer.
Sign Plan & Submission Notes for Citrus Heights
- No sign shall be constructed, installed, or modified unless a building permit and, where applicable, a master sign plan approval is first obtained in compliance with this Chapter, or the sign is allowed without sign permit by exemption.
- A master sign plan is required for new nonresidential projects with four or more tenants.
- A master sign plan is required for major rehabilitation of existing nonresidential projects with four or more tenants (including remodeling or modification to 50% or more of existing signs within 12 months, or significant increases in floor area/facade redesign).
- A master sign plan is required for nonresidential projects requesting an exception to sign regulations.
- The Director may refer any sign permit or master sign plan application to the Commission for review/decision, or may require conditions of approval.
- Approval of a sign permit or master sign plan requires specific findings of compliance with sign standards, design criteria, placement, safety, and compatibility.
- Permit or plan for a sign cannot be approved unless the sign complies with all requirements of the chapter.
- Revisions to a master sign plan may be approved by the Director.
- Signs not in compliance with the approved sign permit/plan may be subject to enforcement.
- Sign permits or master sign plan denials are appealable.
- Certain sign types (e.g., murals, freeway-oriented, electronic message displays, temporary subdivision signs) require special review, findings, or permits beyond a master sign plan.
Source: municode municipal code