Sign Regulations in Fontana, California

Fontana, California has specific sign regulations covering 28 sign types across 6 zoning districts. Regulated sign types include Monument Sign, Driveway/on-site traffic directional sign, Awning Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Sign Regulation Overview for Fontana, California

Sample Sign Requirements in Fontana

Sign TypeMax HeightMax AreaSetback
Monument Sign (Single-Family Residential Subdivision Development)5 ft (includes decorative base and cap)30 sf
Monument Sign (Multiple-Family Uses)5 ft (includes decorative base and cap)24 sf
Wall Sign (Multiple-Family Uses)Shall not be displayed above second story and shall not extend above eave line16 sf

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for FontanaFull Coverage

Sign Types Covered

28

  • Monument Sign
  • Driveway/on-site traffic directional sign
  • Awning Sign
  • Canopy Sign
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Fontana

Frequently Asked Questions

In Fontana, wall signs can be up to Shall not be displayed above second story and shall not extend above eave line and monument signs are limited to 5 ft (includes decorative base and cap). Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Fontana, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Fontana, regulated sign types include Monument Sign, Driveway/on-site traffic directional sign, Awning Sign, Canopy Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Fontana vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Fontana are regulated with specific requirements for brightness, animation, and message duration. Fontana has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Fontana Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Fontana, California sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Fontana, California Sign Rules at a Glance

Fontana, California regulates 28 sign types across 6 zoning districts. Awning Signs in the Commercial Zoning Districts (C-1, C-2), Mixed Use Zoning Districts (RMU), Form-Based Code Zoning Districts (FBC) zoning district are capped at Awning shall not extend above eave line tall and 25% of surface area of awning, including all valances, with a Minimum 2 ft from edge of awning to curb setback (Sec. Table 30-743.A; Sec. 30-743, 30-746(a)). Most commercial signs in Fontana require a permit.

Detailed Sign Ordinance Requirements for Fontana, California

Sign Rules by Zoning District in Fontana (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential Zoning Districts65 ft (includes decorative base and cap)30 sf
Commercial Zoning Districts (C-1, C-2), Mixed Use Zoning Districts (RMU), Form-Based Code Zoning Districts (FBC)1050 ft (includes decorative base and cap; up to 75 ft w/ city flag test)300 sf
Industrial Zoning Districts (M-1, M-2)950 ft (includes decorative base and cap; up to 75 ft w/ city flag test)300 sf
Public and Quasi-Public Zoning Districts (P-PF, P-UC, OS-N, OS-R)25 ft (includes decorative base and cap)24 sf
Downtown Boundary6Must be below eave line; clearance min 8 ft from grade25% of total first floor window glass area (including glass doors)
General Regulations For All Zones310 ft30 sf or 10% of business frontage on which banner is placed, whichever is greater

Zone-by-Zone Sign Requirements in Fontana(sample of 3 of 6 zones)

Residential Zoning Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Monument Sign (Single-Family Residential Subdivision Development)5 ft (includes decorative base and cap)30 sf1 per major neighborhood entrancePermitted only at major neighborhood entrancesUnlockTable 30-742.A; Sec. 30-742
Monument Sign (Multiple-Family Uses)5 ft (includes decorative base and cap)24 sf1 per street frontage with entrancePermitted only at major neighborhood entrancesUnlockTable 30-742.A; Sec. 30-742
Wall Sign (Multiple-Family Uses)Shall not be displayed above second story and shall not extend above eave line16 sf1 per street frontageShall not be displayed above second story and shall not extend above eave lineUnlockTable 30-742.A; Sec. 30-742
Driveway/on-site traffic directional sign4 ft8 sf1 per drivewayPermitted only for developments with more than 12 dwelling unitsUnlockTable 30-742.A; Sec. 30-742
Yard Signs (on private property for temporary sale events)4 ft6 sf1 per street frontage of the propertyOn private property; 1 per street frontageUnlockTable 30-721.A; Sec. 30-721(2)(a); Sec. 30-750
Yard Signs (for sale/lease/rental)4 ft6 sf (on lots <2 acres); 24 sf (on lots >=2 acres)1 per street frontageOn residential property offered for sale/lease/rentalUnlockTable 30-721.A; Sec. 30-721(2)(b), Sec. 30-750

Commercial Zoning Districts (C-1, C-2), Mixed Use Zoning Districts (RMU), Form-Based Code Zoning Districts (FBC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Awning SignAwning shall not extend above eave line25% of surface area of awning, including all valancesMinimum 2 ft from edge of awning to curbN/ALimited to building frontages on ground floorUnlockTable 30-743.A; Sec. 30-743, 30-746(a)
Canopy Sign24 inches (from lowest point on sign)25% of surface area of canopyMinimum 2 ft from edge of canopy to curbSingle Tenant: 1 per building frontage; Multiple Tenant: 1 per tenant spaceLimited to building frontages on ground floorUnlockTable 30-743.A; Sec. 30-743, 30-746(b)
Monument Sign6 ft (includes decorative base and cap)45 sfMinimum 5 ft from any property line; see above for other spacing1 for each 200 ft of street frontageAs near to middle of street frontage or at major driveway entranceUnlockTable 30-743.A; Sec. 30-743, 30-746(d)
Pylon Sign25 ft (includes decorative base and cap)100 sfMinimum 5 ft from any property line; see spacing aboveSingle Tenant: 1 per street frontage with min 165 ft street frontage; Multiple Tenant: 1 per street frontage. Street frontages of 300 ft or greater may have a second pylon sign.As near to the middle of street frontage or major driveway entrance; see Additional RequirementsUnlockTable 30-743.A; Sec. 30-743, 30-746(e)
Wall Sign (Business frontage < 100 ft)Shall not extend above eave line1 sf per lineal foot (max 100 sf)1 primary wall sign per business frontageFlat against the wall; cannot project more than 12 in.UnlockTable 30-743.A; Sec. 30-743, 30-746(f)
Wall Sign (Business frontage ≥ 100 ft)Shall not extend above eave line1 sf per lineal foot (max 150 sf combined); secondary ≤40% of total1 primary wall sign + 2 secondary wall signs per business frontageFlat against the wall; cannot project more than 12 in.UnlockTable 30-743.A; Sec. 30-743, 30-746(f)
Freeway Sign (Buildings < 250,000 sf)50 ft (includes decorative base and cap; up to 75 ft w/ city flag test)150 sfMinimum 5 ft from any property line1 per parcel (min 800 ft freeway frontage)For parcels with min 800 ft freeway frontage; within 400 ft of freeway right-of-wayUnlockTable 30-743.A; Sec. 30-743, 30-746(c)
Freeway Sign (Buildings ≥ 250,000 sf)50 ft (includes decorative base and cap; up to 75 ft w/ city flag test)300 sfMinimum 5 ft from any property line1 per parcel (min 800 ft freeway frontage)For parcels with min 800 ft freeway frontage; within 400 ft of freeway right-of-wayUnlockTable 30-743.A; Sec. 30-743, 30-746(c)

Industrial Zoning Districts (M-1, M-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Awning SignAwning shall not extend above eave line25% of surface area of the awning, including all valancesMinimum 2 ft from edge of awning to curbN/ALimited to building frontages on ground floorUnlockTable 30-744.A; Sec. 30-744, 30-746(a)
Canopy Sign24 in. (from lowest point on sign)25% of surface area of canopyMinimum 2 ft from edge of canopy to curb1 per building frontageLimited to building frontages on ground floorUnlockTable 30-744.A; Sec. 30-744, 30-746(b)
Monument Sign8 ft (includes decorative base and cap)1 sf per lineal foot (max 60 sf)Minimum 5 ft from any property line; see other spacing requirements above1 for each 200 ft of street frontageAs near to the middle of the street frontage or at major driveway entranceUnlockTable 30-744.A; Sec. 30-744, 30-746(d)
Pylon Sign25 ft (includes decorative base and cap)100 sfMinimum 5 ft from any property line; see other spacing requirementsSingle Tenant: 1 per street frontage with min 165 ft street frontage; Multiple Tenant: 1 per street frontage; street frontages of 600 ft or greater may have a second pylon signAs near to the middle of the street frontage or at major driveway entranceUnlockTable 30-744.A; Sec. 30-744, 30-746(e)
Wall Sign (Street Facing)Shall not be displayed above second story and shall not extend above eave line2 sf per lineal foot (max 200 sf)One per street frontage and/or at public entrance facing parking lotStreet facing; or at public entrance facing parking lotUnlockTable 30-744.A; Sec. 30-744, 30-746(f)
Wall Sign (Service and Delivery Entrances)Shall not be displayed above second story and shall not extend above eave line10 sf1 per service or delivery entranceWithin 10 ft of delivery entranceUnlockTable 30-744.A; Sec. 30-744, 30-746(f)
Freeway Sign (Buildings < 250,000 sf)50 ft (includes decorative base and cap; up to 75 ft w/ city flag test)150 sfMin 5 ft from property line1 per parcel (min 800 ft freeway frontage)Min 800 ft freeway frontage; within 400 ft of freeway right-of-wayUnlockTable 30-744.A; Sec. 30-744, 30-746(c)
Freeway Sign (Buildings ≥ 250,000 sf)50 ft (includes decorative base and cap; up to 75 ft w/ city flag test)300 sfMin 5 ft from property line1 per parcel (min 800 ft freeway frontage)Min 800 ft freeway frontage; within 400 ft of freeway right-of-wayUnlockTable 30-744.A; Sec. 30-744, 30-746(c)

PermitPal covers all 6 zoning districts in Fontana — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 6 zones for Fontana — start free

Prohibited Signs in Fontana

  • Sign types not expressly permitted are prohibited.
  • Abandoned signs are prohibited.
  • Animated signs are prohibited.
  • Exposed raceways are prohibited.
  • General advertising signs (billboards) are prohibited except as provided by Division 8.
  • Illegal signs are prohibited.
  • Pole signs are prohibited.
  • Portable (A-frame) signs and projecting signs are prohibited except as permitted by Table No. 30-721.A within the downtown boundary.
  • Roof signs are prohibited except as permitted for roof signs on mansard roofs where no other usable sign area is available.
  • Vehicle signs are prohibited.
  • Signs may not be placed on public property except as required or authorized by a governmental agency, and except as permitted by Division 8 and Division 9.
  • Signs may not be attached to trees.
  • Signs may not be placed on any private property without the permission of the property owner.
  • Signs may not be located so as to interfere with building access, including ingress and egress or emergency exit routes, interfere with pedestrian movement within the public right-of-way, and/or block view of traffic control devices.
  • Signs containing lighting devices with intermittent, flashing, blinking, or varying intensity or light or color where the message is displayed for fewer than eight seconds before changing to another message are prohibited.
  • Signs that simulate in color or design a traffic sign or signal, or which make use of words, symbols, or characters to interfere with, mislead, or confuse pedestrian or vehicular traffic are prohibited.
  • Signs which emit sound, odor, or smoke are prohibited.
  • Temporary signs shall not be illuminated.
  • Private parties may not display or post signs on public property or in the public right-of-way except as expressly allowed.
  • Signs may not be placed in public right-of-way except as provided by Division 9.
  • Any sign posted on public property or the public right-of-way in violation of the article is declared to be a trespass and a public nuisance, may be summarily removed, and responsible parties may be charged for removal costs.
  • Reflective materials shall not be included on signs.
  • All permanent signs must be firmly anchored and comply with all safety codes and requirements.
  • Nonconforming signs shall not be changed to another nonconforming sign, altered unless to reduce/eliminate nonconformity, enlarged, or moved/replaced unless required by the City.

Exempt Signs in Fontana

  • Commemorative signs installed by the City or recognized historical organizations not larger than six square feet, or signs authorized and installed by government agencies on public lands are exempt from design review sign requirements.
  • Equipment signs incorporated into allowed displays, machinery, or equipment by a manufacturer, distributor, or vendor and identifying or advertising only the product or service dispensed by the machine or equipment are exempt from design review sign requirements.
  • Interior graphics or signage within a structure not visible from any public right-of-way or publicly accessible area are exempt from design review sign requirements.
  • Any permitted sign may substitute any commercial message or constitutionally protected noncommercial message without additional approval or permitting, as long as it complies with applicable requirements.
  • Devices excluded from the definition of a 'sign' (see Section 30-783) are exempt.
  • Official non-internally illuminated (unless required by law) notices, signs, or postings required or installed by government agencies for public health/safety, legal notices, traffic/parking signs, address numerals, and similar are exempt from design review sign requirements.
  • Certain types of signs with limitations (see Table No. 30-721.A) are exempt from design review sign requirements if they meet specified size, height, duration, and other requirements; otherwise, design review is required.
  • Traffic control and directional signs erected by government agencies, official notices required by law, signs placed by the City, and signs with an encroachment permit from the City of Fontana are exempt from the general ban on private party signs on public property.

Sign Plan & Submission Notes for Fontana

  • Design review sign applications are required for specific sign types in compliance with Division 4.
  • A design review permanent sign approval is required to erect, move, alter, replace, suspend, display, or attach a permanent sign (general sign, freeway sign, and electronic message sign), unless exempted.
  • A design review temporary sign approval is required to erect, move, alter, replace, suspend, display, or attach a temporary sign, unless exempted.
  • A design review creative sign (minor) application may be submitted for permanent signs exhibiting extraordinary aesthetic quality, creativity, or innovation in specified areas.
  • A design review creative sign (PC) application may be requested for on-site permanent creative signs in specified areas and allows for greater deviation from standards when approved by the Planning Commission.
  • Comprehensive sign program applications (design review sign programs) are allowed for new or existing shopping centers with a site area of six acres or more, mixed-use or commercially zoned properties, or properties with frontage on specified major streets.
  • Sign programs require Planning Commission approval and must specify site plans, total sign area, individual sign areas, maximum number and height, lighting, construction materials, and sign dimensions.
  • A sign variance application, including a public hearing by the Planning Commission, is required if a deviation from sign standards is requested due to unique hardship and must meet specified findings.
  • A design review sign application is required subsequent to City Council approval of a general advertising sign (billboard) relocation agreement.
  • Design review sign applications for signs on public property (e.g., bus shelters) must be approved before construction of general advertising signs on public property proceeds.
  • An encroachment permit is required for any sign that proposes to project into the public right-of-way or onto public property.

Source: municode municipal code