Hermosa Beach, California has specific sign regulations covering 25 sign types across 9 zoning districts. Regulated sign types include Wall Sign, Awning Sign, Window Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 27, 2026

Sign Regulation Overview for Hermosa Beach, California

Sample Sign Requirements in Hermosa Beach

Sign TypeMax HeightMax AreaSetback
Temporary SignUp to 100 sq ft (subject to 40% of permanent sign allowance; at least 20 sq ft allowed)
General Design and Construction - Display SurfacesSections of approved plastics on wall signs shall not exceed 150 sq ft per section
General Projection StandardsShall not project within 2 ft of curbline; alley projection limits based on height; power line clearance as stated

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Hermosa BeachFull Coverage

Sign Types Covered

25

  • Wall Sign
  • Awning Sign
  • Window Sign
  • Mural
  • +2 more types

Zoning Districts

9

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Hermosa Beach

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

Sign height limits in Hermosa Beach vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Hermosa Beach, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Hermosa Beach, regulated sign types include Wall Sign, Awning Sign, Window Sign, Mural, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Hermosa Beach vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Hermosa Beach are regulated with specific requirements for brightness, animation, and message duration. Hermosa Beach has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Hermosa Beach Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Hermosa Beach, California sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Hermosa Beach, California Sign Rules at a Glance

Hermosa Beach, California regulates 25 sign types across 9 zoning districts. Ground Signs in the C-2 zone (restricted commercial) zoning district are capped at ≤8 ft measured from grade to highest point tall and Counts toward total permanent sign area; portable A-frames separately regulated, with a Must be entirely on private property; no projection over public property setback (Sec. HBMC 17.50.130(B)(2), (C)(3), (G)). Most commercial signs in Hermosa Beach require a permit.

Detailed Sign Ordinance Requirements for Hermosa Beach, California

Sign Rules by Zoning District in Hermosa Beach (9 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones5Sections of approved plastics on wall signs shall not exceed 150 sq ft per section
Residential zones (R-1, R-1A, R-2, R-2A, R-2B, R-3, MHP, RPD)7≤8 ft above finished grade (wall signs)≤25 sq ft per site
R-P zone (residential-professional) (Residential uses)7≤8 ft≤25 sq ft per site
R-P zone (residential-professional) (Business uses)8≤8 ft measured from grade to highest point≤25 sq ft per street frontage
OS (open space) zone; OS-1 (restricted open space) zone2
C-1 zone (neighborhood commercial)8≤8 ft measured from grade to highest pointPer business: within total allocation; no sign may cover >25% of wall/fascia it occupies
C-2 zone (restricted commercial)1142 inchesWithin total allocation; no sign may cover >25% of wall/fascia
C-3 zone (general and highway commercial)1142 inchesWithin total allocation; no sign may cover >25% of wall/fascia
M zone (manufacturing) (M-1)942 inchesWithin total allocation; no sign may cover >25% of wall/fascia

Zone-by-Zone Sign Requirements in Hermosa Beach(sample of 3 of 9 zones)

C-2 zone (restricted commercial)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignWithin total allocation; no sign may cover >25% of wall/fasciaProjects ≤6 inches from wall; ends may not be used for sign purposes1 per businessOn building frontage(s)UnlockHBMC 17.50.130(B)(1), (C)(2), (D)(1)-(5), (F)
Ground Sign≤8 ft measured from grade to highest pointCounts toward total permanent sign area; portable A-frames separately regulatedMust be entirely on private property; no projection over public property1 per siteEntirely on private property; cannot project over public propertyUnlockHBMC 17.50.130(B)(2), (C)(3), (G)
Awning SignCounts toward total permanent sign area1 per businessOn awnings over frontageUnlockHBMC 17.50.130(B)(3), (D)(4)
Projecting Sign (Business Identification Only) - Nonilluminated≤4 sq ft per faceMay not project outward more than 3 ftAt least 8 ft above sidewalk; projection ≤3 ft1 per businessHung from wall projection or marquee over entrywayUnlockHBMC 17.50.130(B)(4), (C)(1)
Marquee SignCounts toward total permanent sign area1 per businessOn marqueeUnlockHBMC 17.50.130(B)(5), (C)(1)
Window SignCounts toward total permanent sign areaNo explicit numeric limit; subject to area coverage limitWithin windowsUnlockHBMC 17.50.130(B)(6), (E); 17.50.210(F)
Portable A-frame Sign42 inches24 inches (sign body width); base spread 24–30 inchesAbutting building/curb/planter; maintain 5 ft sidewalk clearance; spacing ≥15 ft from other A-frames; comply with corner vision clearance1 per businessOn private property and/or within public right-of-way on sidewalks along commercial frontages except Pier Plaza; located abutting building, curb, or landscape planter between curb and sidewalk; within the building street frontage; maintain minimum 5 ft sidewalk clearanceUnlockHBMC 17.50.130(A)(7), (B)(9); 17.50.220(A)-(C)
Construction Sign (Additional to Allowable Area)≤6 ft above grade (per general exemption)≤25 sq ft per street frontage1 per street frontageOn each street frontage; private propertyUnlockHBMC 17.50.130(D) Exception; 17.50.040(D)(3)

C-3 zone (general and highway commercial)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignWithin total allocation; no sign may cover >25% of wall/fasciaProjects ≤6 inches from wall; ends may not be used for sign purposes1 per businessOn building frontage(s)UnlockHBMC 17.50.140(B)(1), (C)(1), (D)(1)-(5), (F)
Ground Sign - Option 1≤10 ft from grade to highest portion of sign bodyCounts toward total permanent sign areaMust be entirely on private property; no projection over public property1 per site (mutually exclusive with pole sign)Entirely on private property; cannot project over public propertyUnlockHBMC 17.50.140(B)(2), (C)(2)
Pole Sign - Option 2≤ height of building on same lot OR ≤20 ft, whichever is lesserCounts toward total permanent sign area; only one sign can be attached to a pole sign≥5 ft from adjacent private property line; no encroachment into public right-of-way1 pole sign per site (only one sign attached to it; mutually exclusive with ground sign)On-site; must not encroach/project into public right-of-wayUnlockHBMC 17.50.140(B)(2), (G)
Awning SignCounts toward total permanent sign area1 per businessOn awnings over frontageUnlockHBMC 17.50.140(B)(3), (D)(4)
Marquee SignCounts toward total permanent sign area1 per businessOn marqueeUnlockHBMC 17.50.140(B)(4)
Window SignCounts toward total permanent sign areaNo explicit numeric limit; subject to area coverage limitWithin windowsUnlockHBMC 17.50.140(B)(5), (E); 17.50.210(F)
Portable A-frame Sign42 inches24 inches (sign body width); base spread 24–30 inchesAbutting building/curb/planter; maintain 5 ft sidewalk clearance; spacing ≥15 ft from other A-frames; comply with corner vision clearance1 per businessOn private property and/or within public right-of-way on sidewalks along commercial frontages except Pier Plaza; abutting building, curb, or landscape planter; within the building street frontage; maintain minimum 5 ft sidewalk clearanceUnlockHBMC 17.50.140(A)(7), (B)(8); 17.50.220(A)-(C)
Construction Sign (Additional to Allowable Area)≤6 ft above grade (per general exemption)≤25 sq ft per street frontage1 per street frontageOn each street frontage; private propertyUnlockHBMC 17.50.140(D) Exception; 17.50.040(D)(3)

M zone (manufacturing) (M-1)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignWithin total allocation; no sign may cover >25% of wall/fasciaProjects ≤6 inches from wall; ends may not be used for sign purposes1 per businessOn building frontage(s)UnlockHBMC 17.50.150 (same as C-3 by reference); 17.50.140(B)(1), (C)(1), (D)(1)-(5), (F)
Ground Sign - Option 1≤10 ft from grade to highest portion of sign bodyCounts toward total permanent sign areaMust be entirely on private property; no projection over public property1 per site (mutually exclusive with pole sign)Entirely on private property; cannot project over public propertyUnlockHBMC 17.50.150; 17.50.140(B)(2), (C)(2)
Pole Sign - Option 2≤ height of building on same lot OR ≤20 ft, whichever is lesserCounts toward total permanent sign area; only one sign can be attached to a pole sign≥5 ft from adjacent private property line; no encroachment into public right-of-way1 pole sign per site (only one sign attached; mutually exclusive with ground sign)On-site; must not encroach/project into public right-of-wayUnlockHBMC 17.50.150; 17.50.140(B)(2), (G)
Awning SignCounts toward total permanent sign area1 per businessOn awnings over frontageUnlockHBMC 17.50.150; 17.50.140(B)(3), (D)(4)
Marquee SignCounts toward total permanent sign area1 per businessOn marqueeUnlockHBMC 17.50.150; 17.50.140(B)(4)
Window SignCounts toward total permanent sign areaNo explicit numeric limit; subject to area coverage limitWithin windowsUnlockHBMC 17.50.150; 17.50.140(B)(5), (E); 17.50.210(F)
BannerCounts toward total permanent sign areaOn-site per businessUnlockHBMC 17.50.150; 17.50.140(B)(6)
Portable A-frame Sign42 inches24 inches (sign body width); base spread 24–30 inchesAbutting building/curb/planter; maintain 5 ft sidewalk clearance; spacing ≥15 ft from other A-frames; comply with corner vision clearance1 per businessOn private property and/or within public right-of-way on sidewalks along commercial frontages except Pier Plaza; abutting building, curb, or landscape planter; within the building street frontage; maintain minimum 5 ft sidewalk clearanceUnlockHBMC 17.50.150; 17.50.140(A)(7), (B)(8); 17.50.220(A)-(C)

PermitPal covers all 9 zoning districts in Hermosa Beach — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 9 zones for Hermosa Beach — start free

Prohibited Signs in Hermosa Beach

  • Signs that imitate official traffic signs or signals, or use words like 'stop,' 'go slow,' 'caution,' 'danger,' or 'warning' for advertising in a way that simulates traffic devices and may confuse motorists or pedestrians.
  • Signs whose size, location, movement, content, coloring, or illumination may be confused with or construed as a traffic control device, or which hide traffic control devices from view.
  • Signs advertising any activity, business, product, or service no longer conducted on the premises upon which the sign is located, including off-site signs for such activities.
  • Banners, posters, pennants, ribbons, streamers, lines of flashing light bulbs, spinners, rotating signs, gas-fired torches, or other similar devices that move or have moving parts, unless specifically permitted elsewhere in the code.
  • Flashing, rotating, or scintillating signs designed to give the appearance of movement (except signs indicating time or temperature).
  • Lewd, obscene, or offensive signs containing statements, words, pictures, or graphics of an obscene or indecent character that are offensive to public morals and lack serious literary, artistic, or scientific value.
  • Signs that display a message or graphic representation that discriminates against persons based on race, gender, age, national origin, or any other characteristic protected by federal or state laws.
  • Billboards.
  • Mobile signs (excluding portable A-frame signs permitted under Section 17.50.220).
  • Moving signs.
  • Off-premises signs (except real estate signs).
  • Projecting signs (except for business identification signs in the C-1 and C-2 zones).
  • Roof signs, except on pre-existing architectural projections historically used for signs, or on architectural projections deemed by the planning commission to be part of the building architecture and not solely sign backgrounds.
  • Wind signs.
  • Any signs other than those which are permitted in the zone as set forth in Chapter 17.50.
  • Signs located within 6 feet horizontally or 12 feet vertically of overhead electrical conductors energized in excess of 750 volts.
  • Signs erected so as to interfere with the free use of any fire escape, exit, or standpipe, or that obstruct openings so as to reduce light or ventilation below Uniform Building Code requirements.
  • Signs projecting into any public alley below 14 feet above grade, or more than the allowed projection where above 14 feet, as well as signs projecting within 2 feet of the curbline.
  • Any sign erected in a manner that confuses or obstructs the view or interpretation of official traffic signs, signals, or devices.

Exempt Signs in Hermosa Beach

  • No sign permit is required for changing the identifying copy or message on theater marquees and similar signs specifically designed for replaceable copy.
  • No sign permit is required for repainting or cleaning a sign, unless a structural, copy, or color change is made.
  • No sign permit is required for nonilluminated construction signs up to 25 square feet per site and not more than 6 feet in height, provided construction permits have been obtained and the sign is removed prior to final inspection.
  • No sign permit is required for one nonilluminated real estate sign per site, provided it complies with the real estate sign regulations of the applicable zoning district.
  • No sign permit is required for political signs.
  • No sign permit is required for building identification signs not exceeding 2 square feet in area.
  • Noncommercial copy may be substituted for any commercial copy on any sign otherwise permitted; noncommercial content may be changed without complying with sign copy or design approval, and the sign will not be deemed an off-premises sign.
  • Temporary window signs less than 10 square feet are exempt from the temporary sign application requirement (Section 17.50.210(F)).
  • Temporary sign regulations in Section 17.50.210 do not apply to temporary political signs, temporary real estate signs, or temporary construction signs (Section 17.50.210(E)).

Sign Plan & Submission Notes for Hermosa Beach

  • A Comprehensive Sign Plan is required for proposed commercial developments. Applicants must submit a sign plan showing the location, size, color, and (if possible) copy for all signs, including rendered elevations showing all signs in relation to the structure. The theme must be approved as part of plans for new multi-tenant commercial or industrial developments, and the sign plan is an integral part of the development (Section 17.50.040(C)).
  • All new signs in the OS and OS-1 zones require approval by the planning commission; only wall and ground signs are allowed and must meet materials and illumination limitations (Section 17.50.110).
  • The Department of Building and Safety is the sign reviewing agency and makes final determinations on all signs; determinations may be appealed to the planning commission and further to the city council. For appeals, a notice (at least 16 by 20 inches) must be posted prominently on the premises at least one week prior to the hearing, stating sign details and hearing information (Section 17.50.200).
  • Variances to specific sign requirements may be granted by the planning commission or the city council, on appeal, where a demonstrated hardship exists and the sign will not adversely affect public safety or neighborhood design; required findings include no special privilege, special conditions applying to the property, and no adverse effects (Section 17.50.190).
  • The planning commission or city council may attach reasonable conditions to sign approvals in conjunction with precise development plans, conditional use permits, or other discretionary land uses, with findings on zone permissions, design compatibility, and visibility impacts (Section 17.50.180).

Source: other municipal code