Questions? Call us at (262) 218-2915

Sign Regulations in Redondo Beach, California

Redondo Beach, California has specific sign regulations covering 34 sign types across 7 zoning districts. Regulated sign types include Monument Sign, Wall Sign - Front, Wall Sign - Rear. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: January 9, 2026

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Redondo Beach, California

Sample Sign Requirements in Redondo Beach

Sign TypeMax HeightMax AreaSetback
Temporary BannerNot listed60 square feetNot listed
Balloon Sign16 feet or height of nearest adjacent wall, whichever is lowerNot listedNot listed
Wall SignNot listed32 square feetNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Redondo BeachFull Coverage

Sign Types Covered

34

  • Monument Sign
  • Wall Sign - Front
  • Wall Sign - Rear
  • Wall Sign - Side
  • +2 more types

Zoning Districts

7

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Redondo Beach

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

In Redondo Beach, the height limit for Monument Sign in certain zoning districts is 10 feet above existing grade (including berm) (Sec. 10-2.1810(e)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Redondo Beach require a permit. We haven't published Redondo Beach's application steps on this page yet. Run a code check for an exact address to see the permit requirements for that zone.

Redondo Beach's sign code covers 34 sign types, including Monument Sign, Wall Sign - Front, Wall Sign - Rear, and Wall Sign - Side. Most commercial signs need a permit. The ordinance lists 15 exemptions. One of them: Window signs. The full list is on this page.

In Redondo Beach, Pole or Pylon Sign - Service Station Option in certain zoning districts must be set back at least 15 feet from interior property line (Sec. 10-2.1810(g)(2)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Redondo Beach's sign ordinance that cover digital, changing, or flashing signs: Animated signs, except barber poles and time-temperature signs, and electric message display signs permitted pursuant to Section 10-2.1814 and 10-2.1815. Electronic message displays in public zones require Planning Commission or Harbor Commission Design Review. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Redondo Beach Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Redondo Beach, California, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Redondo Beach, California Sign Rules at a Glance

Redondo Beach, California regulates 34 sign types across 7 zoning districts. Drive-Through Menu Boards in certain zoning districts are capped at 6 feet tall and 30 square feet (Sec. 10-2.1810(h)). Most commercial signs in Redondo Beach require a permit.

Detailed Sign Ordinance Requirements for Redondo Beach, California

Sign Rules by Zoning District in Redondo Beach (7 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones416 feet or height of nearest adjacent wall, whichever is lower60 square feetNot listed
Residential (R-1, R-1A, R-2, R-3, R-3A, RMD, RH-1, RH-2, RH-3, R-MHP)2Not listed32 square feetNot listed
Commercial (C-1, C-2, C-2A, C-2B, C-2-PD, C-3, C-3A, C-3B, C-3-PD, C-4, C-4A, C-4-PD, C-5A, CC-1, CC-2, CC-3, CC-4, CC-5)1210 feet above existing grade (including berm)120 square feet per faceNot listed
Industrial (I-1, I-1A, I-1B, I-2, I-2A, IC-1)1210 feet above existing grade (including berm)120 square feet per faceNot listed
Mixed Use (MU-1, MU-2, MU-3, MU-3A, MU-3C, CR)1410 feet above existing grade (including berm)120 square feet per faceNot listed
Public and Institutional (P-CIV, P-RVP, P-ROW, P-CF, P-PRO, P-SF, P-GP)230 feet above adjacent sidewalk grade120 square feet per face (theater); 60 square feet per face (school)Not listed
Special Districts (Harbor/Pier, Riviera Village)1Not listedNot listedNot listed

Zone-by-Zone Sign Requirements in Redondo Beach(sample of 3 of 7 zones)

Commercial (C-1, C-2, C-2A, C-2B, C-2-PD, C-3, C-3A, C-3B, C-3-PD, C-4, C-4A, C-4-PD, C-5A, CC-1, CC-2, CC-3, CC-4, CC-5)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign - FrontNot listedNot listedNot listedNot listedMultiple, subject to total area limitFront wallNot listedUnlock§ 10-2.1810(a)(1)
Wall Sign - RearNot listedNot listedNot listedNot listedMultiple, subject to total area limitRear wall facing a street, parking area, or pedestrian areaNot listedUnlock§ 10-2.1810(a)(2)
Hanging Sign2 feetNot listed2/3 of the projecting dimension of the awning, canopy, or parapet overhangNot listedNot listedMinimum 8 feet above sidewalk grade, at 90-degree angle to building faceNot listedUnlock§ 10-2.1810(b)
Canopy and Awning SignNot listedLettering up to 2/3 length of canopy/awning x 12 inches height; plus 1 identification emblem/insignia up to 4 square feet2/3 length of canopy/awning for letteringNot listedNot listedOn valance for lettering; other portion for emblemNot listedUnlock§ 10-2.1810(d)
Monument Sign10 feet above existing grade (including berm)100 square feet per faceNot listedNot listedOne per street frontage for listed usesIn landscaped area at least equal to area of one face; one per street frontageNot listedUnlock§ 10-2.1810(e)
Pole and Pylon SignNot listed120 square feet per faceNot listedMinimum 15 feet from interior property line; not over building roofOne per qualifying useIn landscaped area of at least 50 square feetNot listedUnlock§ 10-2.1810(f)
Pole or Pylon Sign - Service Station OptionNot listedNot listedNot listedMinimum 15 feet from interior property lineOneIn lieu of monument signNot listedUnlock§ 10-2.1810(g)(2)
Drive-Through Menu Board6 feet30 square feetNot listedNot listedMaximum 2Not listedNot listedUnlock§ 10-2.1810(h)

Industrial (I-1, I-1A, I-1B, I-2, I-2A, IC-1)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign - FrontNot listedNot listedNot listedNot listedMultiple, subject to total area limitFront wallNot listedUnlock§ 10-2.1810(a)(1)
Wall Sign - RearNot listedNot listedNot listedNot listedMultiple, subject to total area limitRear wall facing a street, parking area, or pedestrian areaNot listedUnlock§ 10-2.1810(a)(2)
Hanging Sign2 feetNot listed2/3 of the projecting dimension of the awning, canopy, or parapet overhangNot listedNot listedMinimum 8 feet above sidewalk grade, at 90-degree angle to building faceNot listedUnlock§ 10-2.1810(b)
Canopy and Awning SignNot listedLettering up to 2/3 length of canopy/awning x 12 inches height; plus 1 identification emblem/insignia up to 4 square feet2/3 length of canopy/awning for letteringNot listedNot listedOn valance for lettering; other portion for emblemNot listedUnlock§ 10-2.1810(d)
Monument Sign10 feet above existing grade (including berm)100 square feet per faceNot listedNot listedOne per street frontage for listed usesIn landscaped area at least equal to area of one face; one per street frontageNot listedUnlock§ 10-2.1810(e)
Pole and Pylon SignNot listed120 square feet per faceNot listedMinimum 15 feet from interior property line; not over building roofOne per qualifying useIn landscaped area of at least 50 square feetNot listedUnlock§ 10-2.1810(f)
Pole or Pylon Sign - Service Station OptionNot listedNot listedNot listedMinimum 15 feet from interior property lineOneIn lieu of monument signNot listedUnlock§ 10-2.1810(g)(2)
Drive-Through Menu Board6 feet30 square feetNot listedNot listedMaximum 2Not listedNot listedUnlock§ 10-2.1810(h)

Mixed Use (MU-1, MU-2, MU-3, MU-3A, MU-3C, CR)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Residential Uses)Not listed32 square feetNot listedNot listedOne per street frontageOn building wall, one per street frontageNot listedUnlock§ 10-2.1812(b); § 10-2.1808(a)
Monument Sign (Residential Uses)Not listed32 square feetNot listedNot listedOne per street frontageFreestanding, one per street frontageNot listedUnlock§ 10-2.1812(b); § 10-2.1808(a)
Hanging Sign (Commercial Uses)2 feetNot listed2/3 of the projecting dimension of the awning, canopy, or parapet overhangNot listedNot listedMinimum 8 feet above sidewalk grade, at 90-degree angle to building faceNot listedUnlock§ 10-2.1812(a),(c); § 10-2.1810(b)
Canopy and Awning Sign (Commercial Uses)Not listedLettering up to 2/3 length of canopy/awning x 12 inches height; plus 1 identification emblem/insignia up to 4 square feet2/3 length of canopy/awning for letteringNot listedNot listedOn valance for lettering; other portion for emblemNot listedUnlock§ 10-2.1812(a),(c); § 10-2.1810(d)
Monument Sign (Commercial Uses)10 feet above existing grade (including berm)100 square feet per faceNot listedNot listedOne per street frontage for listed usesIn landscaped area at least equal to area of one face; one per street frontageNot listedUnlock§ 10-2.1812(a),(c); § 10-2.1810(e)
Pole and Pylon Sign (Commercial Uses)Not listed120 square feet per faceNot listedMinimum 15 feet from interior property line; not over building roofOne per qualifying useIn landscaped area of at least 50 square feetNot listedUnlock§ 10-2.1812(a),(c); § 10-2.1810(f)
Pole or Pylon Sign - Service Station Option (Commercial Uses)Not listedNot listedNot listedMinimum 15 feet from interior property lineOneIn lieu of monument signNot listedUnlock§ 10-2.1812(a),(c); § 10-2.1810(g)(2)
Drive-Through Menu Board (Commercial Uses)6 feet30 square feetNot listedNot listedMaximum 2Not listedNot listedUnlock§ 10-2.1812(a),(c); § 10-2.1810(h)

PermitPal covers all 7 zoning districts in Redondo Beach. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Redondo Beach

  • "A frame" signs except as permitted by the Community Development Director or assigned within the Artesia and Aviation Area Plan area
  • Any other portable signs, except for permitted menu boards in connection with outdoor dining
  • Animated signs, except barber poles and time-temperature signs, and electric message display signs permitted pursuant to Section 10-2.1814 and 10-2.1815
  • Any sign which, by color, shape, location or other means endangers public safety by resembling or conflicting with any traffic control sign or device or which due to its dangerous construction, manner of display, or location is determined by the Community Development Director or the City Engineer to be hazardous
  • Any sign displaying obscene, indecent, or immoral matter
  • Audible signs, except in connection with drive-up windows
  • Billboards
  • Graffiti. No sign shall contain graphic representations designed to imitate, resemble, duplicate or give the appearance of any symbols, letter styles, plakas or other identifying features of any street gang, or tagging origin
  • Home business signs
  • Roof signs
  • Signs erected without the permission of the owner, or his agent, of the property on which or over which such sign is located
  • Temporary signs, including, but not limited to, balloon signs, banners, flags, and pennants, except as provided in Section 10-2.1820
  • Vehicle signs. No person shall park any vehicle or trailer on public property, or on private property so as to be visible from a public right-of-way, which vehicle has attached thereto or located thereon any sign or advertising device for the purpose of providing advertisements of products located on the same or nearby property or directing people to a business or activity located on the same or nearby property. This subsection is not intended to apply to standard advertising or identification practices where such signs or advertising devices are painted on or permanently attached to a business or commercial vehicle.

Exempt Signs in Redondo Beach

  • Window signs
  • Official and legal notices issued by a court or governmental agency
  • The official flag of a government or institution, including the display of the United States flag, the flag of the State of California, or any other county, state or political subdivision
  • Construction signs during the period of construction not exceeding a total of 32 square feet. A larger total sign area may be permitted subject to Administrative Design Review for projects on larger sites with a substantial length of street frontage
  • One "Garage Sale" temporary sign not exceeding six square feet and located only on the premises upon which the sale is occurring
  • One menu board no more than six square feet in conjunction with permitted outdoor dining
  • Political signs not exceeding 16 square feet per sign, based upon the holding in Baldwin v. Redwood City, 540 F. 2d 1360
  • Real estate signs, provided that: In residential zones: The sign must be displayed on a site where one or more dwelling units are being offered for sale, rent or lease, or at another site with the consent of the owner. No sign shall exceed six square feet, except where more than one unit of a condominium is offered for sale, rent or lease, the signs may be combined in a single supporting structure, and the sign area shall not exceed three square feet per unit offered. No flags, pennants, or similar devices shall be permitted, except during the hours of an "open house." In nonresidential zones, there shall be no more than one sign and the sign shall not exceed 32 square feet
  • "No trespassing," "no parking," "no solicitors," and other similar warning signs of no more than two square feet
  • Parking entrance and exit signs, other private traffic, or pedestrian directional signs or other informational signs not to exceed 12 square feet in area. Oriented along the street frontage, there shall be no more than one such sign per entrance to the parcel
  • Tenant directory signs near building entrances for use by pedestrians for informational purposes only
  • Service station signs required by law, as follows: Copy applied to fuel pumps or dispensers such as fuel identification, station logo, and other signs required by law. Petroleum price signs required to be visible from the street, limited to one sign per street frontage not exceeding 20 square feet per sign. Price signs shall be permanently affixed to a building or canopy, or installed in the ground
  • Holiday decorations
  • Business door nameplates, not exceeding two square feet in area, and containing the name and address of the business only, affixed only to the door of each individual business or immediately adjacent thereto
  • For each residential dwelling unit, one identification sign or commemorative plaque of no more than two square feet and one house number or address of no more than two square feet

Sign Plan & Submission Notes for Redondo Beach

  • A sign or sign program is required in conjunction with any project requiring discretionary approval by the Planning Commission, except that signs established subsequent to the approval of a sign program by the Planning Commission shall be subject to Administrative Design Review
  • New pole or pylon signs, or changes to existing pole or pylon signs (except change of copy or repair), require Planning Commission Design Review
  • New monument signs, or changes to existing monument signs (except change of copy or repair) exceeding six feet in height (including berming), require Planning Commission Design Review
  • New signs that do not meet the sign regulations established in this article (except prohibited signs) require Planning Commission Design Review
  • In public and institutional zones, any new sign or change to an existing sign (other than change of copy) exceeding 30 square feet requires Planning Commission Design Review; signs 30 square feet or less require Administrative Design Review; electronic message display signs, regardless of area, require Planning Commission or Harbor Commission Design Review
  • Off-site directional and/or identification signs for Special Districts require Planning Commission Design Review (or Harbor Commission Design Review if located within the Harbor/Pier area)
  • For service stations, pole or pylon signs in lieu of monument signage, when necessary for visibility, require Planning Commission Design Review
  • Projecting signs extending a maximum of three feet above the adjacent eave or parapet line may be approved subject to Planning Commission Design Review if insufficient area is available for other sign solutions and architecturally integrated
  • Mansard roof signs not approved by the Community Development Director may be requested via Planning Commission Design Review
  • Electronic message displays in public zones require Planning Commission or Harbor Commission Design Review
  • In mixed-use zones with mixed uses, signage must be designed and located to avoid conflict with residential uses, potentially requiring review
  • For nonconforming uses in residential zones, new signs or changes (other than copy) exceeding 30 square feet require Planning Commission Design Review; 30 square feet or less require Administrative Design Review

Source: ecode360 municipal code