Sign Regulations in Victorville, California
Victorville, California has specific sign regulations covering 30 sign types across 13 zoning districts. Regulated sign types include Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (< 1 acre), Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (> 1 acre), Banner (Temporary). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 9, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Victorville, California
Sample Sign Requirements in Victorville
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Freestanding Sign (Temporary - Property Sale/Lease/Construction) (< 1 acre) | 6 feet | 12 sq. ft. | Not listed |
| Freestanding Sign (Temporary - Property Sale/Lease/Construction) (> 1 acre) | 10 feet | 32 sq. ft. | Not listed |
| Freestanding Sign (Off-Site Residential Housing ID) | Not listed | Per city-administered program (kiosk and related sign programs) | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
30
- Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (< 1 acre)
- Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (> 1 acre)
- Banner (Temporary)
- Window Sign (Temporary and Permanent)
- +2 more types
Zoning Districts
13
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Victorville
Other Cities in California
Frequently Asked Questions
In Victorville, the height limit for Freestanding Sign (< 2 acres) in the Neighborhood Service (C-1, C1) zoning districts is 24 ft. Maximum sign heights range from 6 feet to 24 ft across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Victorville require a permit. From the submission notes on this page: Each Master Sign Program must specify permitted colors, letter and font designs, sizes, number and locations of all signs; approval is required prior to issuance of sign permits/applications for tenants. Run a code check for an exact address to see the permit requirements for that zone.
Victorville's sign code covers 30 sign types, including Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (< 1 acre), Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (> 1 acre), Banner (Temporary), and Window Sign (Temporary and Permanent). Most commercial signs need a permit. The ordinance lists 9 exemptions. One of them: Required numerals for street address display for permanent structures to enhance public safety (fire/police). The full list is on this page.
We haven't published Victorville's sign setback rules on this page yet. Run a code check for an exact address to see them.
Rules in Victorville's sign ordinance that cover digital, changing, or flashing signs: Billboard signs, including the relocation, expansion, or conversion to digital display of existing billboards, are prohibited except as provided for in Section 16-3.22.180 and Section 16-3.22.190. Erection of signs on or over public property is prohibited, except for municipal signs, certain relocated billboards, or digital display billboards as provided in Sections 16-3.22.180/190. Animated signs that flash or blink are prohibited unless approved by the Zoning Administrator and found to be of no threat to public health, safety, and welfare. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Victorville Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Victorville, California, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Victorville, California Sign Rules at a Glance
Victorville, California regulates 30 sign types across 13 zoning districts. Freestanding Signs (< 2 acres) in the Neighborhood Service (C-1, C1) zoning districts are capped at 24 ft tall and 100 sq ft. Most commercial signs in Victorville require a permit.
Detailed Sign Ordinance Requirements for Victorville, California
Sign Rules by Zoning District in Victorville (13 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Exclusive Agriculture (AE), Suburban Residential (S-R, SR), Single-Family Residential (R-1, R1), Low-Medium Density Residential (R-2, R2), Medium Density Residential (R-3, R3), High Density Residential (R-4, R4), Mixed Density Residential (MDR), Residential-Mobile Home Planned Development (R-MPD, RMPD), Low Density Residential Infill Overlay (LDRIO) | 7 | 10 feet | 45 sq. ft. (not to exceed 10 ft length) | Not listed |
| Neighborhood Service (C-1, C1) | 8 | 24 ft. | 100 sq. ft. | Not listed |
| General Commercial (C-2, C2, C-4, C4), Commercial Manufacturing (C-M, CM) | 8 | 24 ft. | 100 sq. ft. | Not listed |
| Administrative Professional Offices (C-A, CA) | 7 | 10 feet | Max 300 sq. ft. per building | Not listed |
| Industrial Park (I.P.D., IPD), Light Industrial (M-1, M1), Heavy Industrial (M-2, M2) | 8 | 10 feet | Not to exceed 450 sq. ft. | Not listed |
| Public and Civic (P-C, PC) | 3 | 6 feet | 45 sq. ft. per sign face | Not listed |
| Greenway Utility Corridor (GUC) | 1 | Not listed | Not listed | Not listed |
| Conservancy and Flood Plain (FP) | 1 | 6 feet | 45 sq. ft. | Not listed |
| Specific Plan (S-P, SP) | 1 | Not listed | Not listed | Not listed |
| Planned Unit Development (P.U.D., PUD) | 1 | Not listed | Not listed | Not listed |
| Medium Density Mixed Use (MU-1, MU1), High Density Mixed Use (MU-2, MU2) | 1 | Not listed | Not listed | Not listed |
| Health and Wellness Overlay (HWO) | 1 | Not listed | Not listed | Not listed |
| General Regulations For All Zones | 2 | Not listed | 10% of window area (20% of window area in C-2 zone) | Not listed |
Zone-by-Zone Sign Requirements in Victorville(sample of 3 of 13 zones)
Neighborhood Service (C-1, C1)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (< 1 acre) | 6 feet | 12 sq. ft. | Not listed | Not listed | One per parcel | On parcel | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (> 1 acre) | 10 feet | 32 sq. ft. | Not listed | Not listed | One per parcel | On parcel | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Banner (Temporary) | Not listed | Equal to total sign area allowed for permanent signs | Not listed | Not listed | Not listed | Building wall | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Window Sign (Temporary and Permanent) | Not listed | 10% of window area | Not listed | Not listed | Not listed | Window(s) on building | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Wall Sign (Tenant/Building/Center ID) | Not listed | Not listed | Not listed | Not listed | Not listed | Building wall | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Monument Sign | 6 ft. | 45 sq. ft. (not to exceed 10 feet in length) | 10 ft. | Not listed | One per site or one per street frontage | In lieu of freestanding sign, one per site or per street frontage; not located further than 40 ft from street frontage | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Freestanding Sign (< 2 acres) | 24 ft. | 100 sq. ft. | Not listed | Not listed | One per parcel | In lieu of monument sign, one per parcel | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Freestanding Sign (> 2 acres) | 24 ft. | 100 sq. ft. for single use; 150 sq. ft. for multi-tenant sign | Not listed | Not listed | One per site or per arterial street frontage | In lieu of monument sign, one per site or per arterial street frontage | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
General Commercial (C-2, C2, C-4, C4), Commercial Manufacturing (C-M, CM)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (< 1 acre) | 6 feet | 12 sq. ft. | Not listed | Not listed | One per parcel | On parcel | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (> 1 acre) | 10 feet | 32 sq. ft. | Not listed | Not listed | One per parcel | On parcel | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Banner (Temporary) | Not listed | Equal to total sign area allowed for permanent signs | Not listed | Not listed | Not listed | Building wall | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Window Sign (Temporary and Permanent) | Not listed | 10% of window area (20% in C-2 District) | Not listed | Not listed | Not listed | Window(s) on building | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Wall Sign (Tenant/Building/Center ID) | Not listed | Not listed | Not listed | Not listed | Not listed | Building wall | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Monument Sign | 6 ft. | 45 sq. ft. (not to exceed 10 feet in length) | 10 ft. | Not listed | One per site or one per street frontage | In lieu of freestanding sign, one per site or per street frontage; not located further than 40 ft from street frontage | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Freestanding Sign (< 2 acres) | 24 ft. | 100 sq. ft. | Not listed | Not listed | One per parcel | In lieu of monument sign, one per parcel | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
| Freestanding Sign (> 2 acres) | 24 ft. | 100 sq. ft. for single use; 150 sq. ft. for multi-tenant sign | Not listed | Not listed | One per site or per arterial street frontage | In lieu of monument sign, one per site or per arterial street frontage | Not listed | Unlock | Sec. 16-3.22.130, Table 22-3 |
Industrial Park (I.P.D., IPD), Light Industrial (M-1, M1), Heavy Industrial (M-2, M2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (< 1 acre) | 6 feet | 12 sq. ft. | Not listed | Not listed | One per parcel | On parcel | Not listed | Unlock | Sec. 16-3.22.140, Table 22-4 |
| Freestanding or Wall Sign (Temporary - Property Sale/Lease/Construction) (> 1 acre) | 10 feet | 32 sq. ft. | Not listed | Not listed | One per parcel | On parcel | Not listed | Unlock | Sec. 16-3.22.140, Table 22-4 |
| Banner (Temporary) | Not listed | Equal to total sign area allowed for permanent signs | Not listed | Not listed | Not listed | Building wall | Not listed | Unlock | Sec. 16-3.22.140, Table 22-4 |
| Window Sign (Temporary and Permanent) | Not listed | 10% of window area | Not listed | Not listed | Not listed | Window(s) on building | Not listed | Unlock | Sec. 16-3.22.140, Table 22-4 |
| Wall Sign (Tenant/Building ID) | Not listed | Not to exceed 450 sq. ft. | Not listed | Not listed | Not listed | Building wall | Not listed | Unlock | Sec. 16-3.22.140, Table 22-4 |
| Monument Sign (less than 100,000 sq. ft. building) | 6 ft. | 50 sq. ft. | Not listed | Not listed | One per site or one per arterial street frontage | One per site or one per arterial street frontage | Not listed | Unlock | Sec. 16-3.22.140, Table 22-4 |
| Monument Sign (100,001 - 250,000 sq. ft. building) | 6 ft. | 100 sq. ft. | Not listed | Not listed | One per site or one per arterial street frontage | One per site or one per arterial street frontage | Not listed | Unlock | Sec. 16-3.22.140, Table 22-4 |
| Monument Sign (over 250,000 sq. ft. building) | 6 ft. | 150 sq. ft. | Not listed | Not listed | One per site or one per arterial street frontage | One per site or one per arterial street frontage | Not listed | Unlock | Sec. 16-3.22.140, Table 22-4 |
PermitPal covers all 13 zoning districts in Victorville. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Victorville
- No sign shall be erected, constructed, attached, affixed, or maintained on any property, except in conformity with the provisions of Article 22 (Signs).
- It shall be illegal to use, occupy, or maintain property in violation of Article 22 (Signs).
- Any violation or failure to comply with the provisions of Article 22 (Signs) shall be illegal.
- Billboard signs, including the relocation, expansion, or conversion to digital display of existing billboards, are prohibited except as provided for in Section 16-3.22.180 and Section 16-3.22.190.
- Painted signs are prohibited.
- Pole signs are prohibited, unless architecturally integral into the overall development of the site.
- Reader or message boards are prohibited, unless approved with conditions by the Zoning Administrator for certain uses (schools, parks, civic buildings, large commercial shopping centers adjacent to interstate freeway).
- Roof signs are prohibited; one roof sign may be permitted by the Zoning Administrator only with a specific finding that no other sign configuration can serve the intended purpose.
- Erection of signs on or over public property is prohibited, except for municipal signs, certain relocated billboards, or digital display billboards as provided in Sections 16-3.22.180/190.
- Signs that create a safety hazard by obstructing clear view of pedestrians or vehicular traffic are prohibited.
- Signs that emit or generate sound, smoke, or similar material are prohibited.
- Vehicle signs are prohibited unless used for business-related transportation and not primarily for advertising.
- Signs containing unprotected speech (i.e., obscenity, fighting words, misleading/deceptive commercial messages, messages promoting illegal products/services) are prohibited.
- Commercial and industrial signs that are within 50 feet and are visible from a residential district are prohibited.
- Animated signs that flash or blink are prohibited unless approved by the Zoning Administrator and found to be of no threat to public health, safety, and welfare.
- Exposed fluorescent tubes or incandescent bulbs exceeding 15 watts are not permitted for sign illumination unless approved as part of a Master Sign Plan or for designated uses.
- Awnings shall not be internally illuminated.
- Signs not on the same site as the business/use they advertise are prohibited unless otherwise expressly permitted (exceptions: street banners, authorized decorations, billboard relocation, and kiosk/wayfinding programs).
Exempt Signs in Victorville
- Any sign, posting, notice, or indication used exclusively to display official governmental notices, notices of any court or public office, or those posted by a public officer in the performance of public duty or required by law.
- Street name and traffic control signs, directional signs, informational signs of a public or semi-public nature, historical markers placed by a governmental or non-profit organization, and railroad crossing, construction, danger, or other emergency warning signs.
- Signs guiding and directing traffic in parking lots and facilities, including directional markings painted on pavement, provided no individual sign exceeds six (6) square feet in area and not more than five (5) feet in height.
- Signs showing locations of public restrooms, telephones, or other public conveniences, provided the sign does not advertise a use or product.
- Signs indicating business hours, emergency phone numbers, credit cards, association memberships, and similar, provided no individual sign exceeds one and one-half (1.5) square feet and the total area does not exceed four and one-half (4.5) square feet.
- Signs located entirely within a building and not within three (3) feet of a window and therefore not visible from the exterior.
- Menu boards not exceeding thirty-six (36) square feet in area or six (6) feet in height for drive-in, drive-through, or walk-up restaurants, limited to two per restaurant.
- Service station price signs one per street frontage, not exceeding twenty-four (24) square feet in area and six (6) feet in height, designed as a permanent structure, only for on-site gasoline price and hours.
- Required numerals for street address display for permanent structures to enhance public safety (fire/police).
Sign Plan & Submission Notes for Victorville
- Plan review (sign permit) is required for the construction, erection, installation, relocation, or alteration of all temporary or permanent signs, except for exempt signs listed in Section 16-3.22.030.
- Plan review is conducted by the Zoning Administrator or designee. It is unlawful to erect, alter, or relocate any sign (except exempt signs) without first obtaining a sign permit or building permit if required.
- Deviations from the sign standards may be granted through approval of a Master Sign Program by the Planning Commission, through the Conditional Use Permit process, when specific quality/design findings are met.
- Master Sign Program is required for proposed or expanded commercial or industrial centers containing five (5) or more tenants for a unified design theme; new tenants must comply with the approved Master Sign Program.
- Each Master Sign Program must specify permitted colors, letter and font designs, sizes, number and locations of all signs; approval is required prior to issuance of sign permits/applications for tenants.
- Administrative Site Plan review is required for digital billboard conversion involving reduction only (see Sec. 16-3.22.190).
- For wall murals (that are not signage), Planning Commission approval (Conditional Use Permit) is required; historic wall murals are subject to administrative review and approval.
Source: municode municipal code