Sign Regulations in Greeley, Colorado

Greeley, Colorado has specific sign regulations covering 11 sign types across 16 zoning districts. Regulated sign types include Construction Site Sign, Freestanding Sign, Wall Sign. Height restrictions apply. Use PermitPal to get instant access to the complete regulations.

Data last verified: March 6, 2025

Sign Regulation Overview for Greeley, Colorado

Sample Sign Requirements in Greeley

Sign TypeMax HeightMax AreaSetback
Construction Site Sign5 feet7 square feet per face
Construction Site Sign (Less than 200 feet frontage)8 feet24 square feet per face
Construction Site Sign (200-500 feet frontage)8 feet32 square feet per face

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for GreeleyPartial Coverage

Sign Types Covered

11

  • Construction Site Sign
  • Freestanding Sign
  • Wall Sign
  • No Smoking Sign
  • +2 more types

Zoning Districts

16

Different zoning districts with specific sign regulations

Data Includes

  • Height restrictions
  • Illumination rules

Official Resources for Greeley

City WebsiteMunicipal Code7 permit application links available

Frequently Asked Questions

Sign height limits in Greeley vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Greeley, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Greeley, regulated sign types include Construction Site Sign, Freestanding Sign, Wall Sign, No Smoking Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Greeley vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Greeley are regulated with specific requirements for brightness, animation, and message duration. Greeley has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Greeley Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Greeley, Colorado sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Greeley, Colorado Sign Rules at a Glance

Greeley, Colorado regulates 11 sign types across 16 zoning districts. Construction Site Sign (Less than 200 feet frontage)s in the Nonresidential zoned properties zoning district are capped at 8 feet tall and 24 square feet per face (Sec. Sec. 24-902. - Exempt signs).

Detailed Sign Ordinance Requirements for Greeley, Colorado

Sign Rules by Zoning District in Greeley (16 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones4
Residentially zoned properties15 feet7 square feet per face
Nonresidential zoned properties310 feet64 square feet per face
H-A15 feet7 square feet per face
C-D15 feet7 square feet per face
R-L15 feet7 square feet per face
R-E15 feet7 square feet per face
R-MH15 feet7 square feet per face
R-M15 feet7 square feet per face
R-H26 feet40 s.f., plus 1 s.f. for each 1' setback over 50', up to maximum 150 s.f.
C-L26 feet40 s.f., plus 1 s.f. for each 1' setback over 50', up to maximum 150 s.f.
C-H212 feet plus 0.26' for each 1' setback over 50', up to a maximum of 25'60 s.f., plus 1 s.f. for each 1' setback over 50', up to maximum 200 s.f.
I-L212 feet plus 0.26' for each 1' setback over 50', up to a maximum of 25'60 s.f., plus 1 s.f. for each 1' setback over 50', up to maximum 200 s.f.
I-M212 feet plus 0.26' for each 1' setback over 50', up to a maximum of 25'90 s.f., plus 1 s.f. for each 1' setback over 50', up to maximum 250 s.f.
I-H212 feet plus 0.26' for each 1' setback over 50', up to a maximum of 25'90 s.f., plus 1 s.f. for each 1' setback over 50', up to maximum 250 s.f.
Planned Unit Development (PUD)1

Zone-by-Zone Sign Requirements in Greeley(sample of 3 of 16 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
No Smoking SignPublic places and common areasUnlockSec. 12-154. - Signs prohibiting smoking.
No Trespass SignNear each possible access point to the propertyUnlockSec. 12-388. - Posting of no trespass, other warning and notice signs.
No Solicitation SignAt or near the entrance of private residences or officesUnlockSec. 14-186. - Signs against solicitation or peddling to be obeyed.
Traffic Control SignMunicipal streets and highwaysUnlockSec. 16-186. - City to sign highways; where.

Nonresidential zoned properties

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Construction Site Sign (Less than 200 feet frontage)8 feet24 square feet per faceUp to three per street frontageOn siteUnlockSec. 24-902. - Exempt signs
Construction Site Sign (200-500 feet frontage)8 feet32 square feet per faceUp to three per street frontageOn siteUnlockSec. 24-902. - Exempt signs
Construction Site Sign (Greater than 500 feet frontage)10 feet64 square feet per faceUp to three per street frontageOn siteUnlockSec. 24-902. - Exempt signs

R-H

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Sign6 feet33 square feet plus 1 s.f. for each 1' setback over 50', up to a maximum of 150 s.f.1 sign where lot frontage is greater than or equal to 200 ft., but less than 500 ft.On siteUnlockSec. 24-905.d
Wall Sign40 s.f., plus 1 s.f. for each 1' setback over 50', up to maximum 150 s.f.On building wallUnlockSec. 24-905.f

PermitPal covers all 16 zoning districts in Greeley — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 16 zones for Greeley — start free

Prohibited Signs in Greeley

  • Exposed incandescent, high-intensity exposed light bulbs are prohibited.
  • Flashing, animated or imitating signs, including signs that have moving, blinking, chasing, scrolling, or other animation effects, are prohibited.
  • Off-premises signs are prohibited except for specific exceptions.
  • Nongovernmental signs on public utilities are prohibited.
  • No signs other than regulatory signs are allowed in the public right-of-way without a permit.
  • No person may damage, destroy, trim or remove any trees or shrubs located within the public right-of-way for increasing visibility of a sign.

Exempt Signs in Greeley

  • Required signs are exempt from the sign permit process.
  • Temporary signs associated with approved temporary uses are exempt.
  • Construction site signs are exempt under specific conditions.
  • Cornerstone signs up to four square feet are exempt.
  • Directional on-premises signs are exempt under specific conditions.
  • Interior signs not legible beyond the property boundaries are exempt.
  • Public signs required by law are exempt.

Sign Plan & Submission Notes for Greeley

  • A specific and coordinated sign plan is required for planned unit developments (PUD).
  • Applications for alternative compliance must include a sign plan with specific details.
  • Variances to dimensional standards require a process and criteria review.

Source: municode municipal code