Sign Regulations in Keenesburg, Colorado
Keenesburg, Colorado has specific sign regulations covering 25 sign types across 5 zoning districts. Regulated sign types include All Signs (Aggregate), Freestanding or Ground Sign, Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 8, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Keenesburg, Colorado
Sample Sign Requirements in Keenesburg
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| All Signs (Aggregate) | Not listed | Total lot: 1,500 sq ft. Any single sign: 780 sq ft. | Not listed |
| Freestanding or Ground Sign | 50 ft above highest grade of I-76 | 780 sq ft (but also limited by total lot maximum) | Not listed |
| Wall Sign | Not listed | 125 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
25
- All Signs (Aggregate)
- Freestanding or Ground Sign
- Wall Sign
- All Signs
- +2 more types
Zoning Districts
5
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
Official Resources for Keenesburg
Other Cities in Colorado
Frequently Asked Questions
In Keenesburg, the height limit for Freestanding or Ground Sign in the Interstate 76 zone is 50 ft above highest grade of I-76. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Keenesburg require a permit. From the submission notes on this page: Signs in PUD zoned districts are subject to review as required in Section 16-7-80 (variance/special permit process); signs reviewed in conjunction with the final PUD plan review count as fulfilling this requirement. Run a code check for an exact address to see the permit requirements for that zone.
Keenesburg's sign code covers 25 sign types, including All Signs (Aggregate), Freestanding or Ground Sign, Wall Sign, and All Signs. Most commercial signs need a permit. The ordinance lists 19 exemptions. One of them: Address signs are exempt from permit requirements. The full list is on this page.
We haven't published Keenesburg's sign setback rules on this page yet. Run a code check for an exact address to see them.
Rules in Keenesburg's sign ordinance that cover digital, changing, or flashing signs: Flashing red, green or amber signs located within one hundred feet of an intersection are prohibited. Run a code check for an exact address to see the rules for that zone.
Ready to Research Keenesburg Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Keenesburg, Colorado, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Keenesburg, Colorado Sign Rules at a Glance
Keenesburg, Colorado regulates 25 sign types across 5 zoning districts. Wall Signs in the Interstate 76 zone are capped at 125 sq ft (Sec. 16-7-30(a)(4)). Most commercial signs in Keenesburg require a permit.
Detailed Sign Ordinance Requirements for Keenesburg, Colorado
Sign Rules by Zoning District in Keenesburg (5 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Interstate 76 zone | 3 | 50 ft above highest grade of I-76 | Total lot: 1,500 sq ft. Any single sign: 780 sq ft. | Not listed |
| Commercial Zoning Districts (C), Industrial Zoning Districts (I) | 3 | 25 ft above surrounding ground level | Total lot: 300 sq ft | Not listed |
| Residential Zoning Districts | 4 | Not listed | 16 sq ft per face | Not listed |
| Planned Unit Development Zoning Districts (PUD) | 1 | Not listed | Not listed | Not listed |
| General Regulations For All Zones | 18 | Not listed | 100 sq ft (no limit for United States flag) | Not listed |
Zone-by-Zone Sign Requirements in Keenesburg(sample of 3 of 5 zones)
Interstate 76 zone
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| All Signs (Aggregate) | Not listed | Total lot: 1,500 sq ft. Any single sign: 780 sq ft. | Not listed | Not listed | Not listed | On same lot or combined lots forming a single building site | Not listed | Unlock | Sec. 16-7-30(a)(1), (2), (6) |
| Freestanding or Ground Sign | 50 ft above highest grade of I-76 | 780 sq ft (but also limited by total lot maximum) | Not listed | Not listed | 1 per lot or parcel (combined lots as one site) | On same lot or combined lots forming a single building site | Not listed | Unlock | Sec. 16-7-30(a)(3), (5) |
| Wall Sign | Not listed | 125 sq ft | Not listed | Not listed | Not listed | Mounted on building wall | Not listed | Unlock | Sec. 16-7-30(a)(4) |
Commercial Zoning Districts (C), Industrial Zoning Districts (I)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| All Signs (Aggregate) | Not listed | Total lot: 300 sq ft | Not listed | Not listed | Not listed | On same lot or combined lots forming a single building site | Not listed | Unlock | Sec. 16-7-30(b)(1), (2), (7) |
| Freestanding or Ground Sign | 25 ft above surrounding ground level | 125 sq ft per face (max 1 face). Additional cabinets: 50 sq ft each (max 4 cabinets) | Not listed | Not listed | 1 per lot or parcel (combined lots as one site) | On same lot or combined lots forming a single building site | Not listed | Unlock | Sec. 16-7-30(b)(4), (6) |
| Wall Sign | Not listed | 125 sq ft | Not listed | Not listed | Not listed | Mounted on building wall | Not listed | Unlock | Sec. 16-7-30(b)(5) |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Special Sign (Sandwich Board, A-frame, etc.) | Not listed | 16 sq ft per face | Not listed | Not listed | 1 per street frontage | On private property, not public rights-of-way | Not listed | Unlock | Sec. 16-7-20(29); Sec. 16-7-60(17) |
| Window Sign - Temporary | Not listed | No more than 50% of the window area | Not listed | Not listed | Not listed | Within 12 inches of any exterior window | Not listed | Unlock | Sec. 16-7-20(33)(a); Sec. 16-7-60(19) |
| Window Sign - Permanent | Not listed | No more than 50% of the window area | Not listed | Not listed | Not listed | Within 12 inches of any exterior window | Not listed | Unlock | Sec. 16-7-20(33)(b); Sec. 16-7-60(19) |
| Residential Complex or Subdivision Identification Sign | Not listed | 30 sq ft on local/collector roads, 50 sq ft on arterial roads | Not listed | Not listed | 1 per public access/driveway | On-site, at entry to residential complex/subdivision | Not listed | Unlock | Sec. 16-7-20(24); Sec. 16-7-60(16) |
| Address Sign | Not listed | 2 sq ft | Not listed | Not listed | 2 per street front | On building or property | Not listed | Unlock | Sec. 16-7-20(1); Sec. 16-7-60(1) |
| Contractor Sign | Not listed | 32 sq ft (unless more required by law) | Not listed | Not listed | Not listed | On property where work is performed | Not listed | Unlock | Sec. 16-7-20(7); Sec. 16-7-60(5) |
| Directional On-site Sign | Not listed | 6 sq ft | Not listed | Not listed | Not listed | On premises, directing traffic | Not listed | Unlock | Sec. 16-7-20(8); Sec. 16-7-60(6) |
| Incidental Sign | Not listed | 1.5 sq ft (any single); total: 1 sq ft per 10 lineal ft street frontage | Not listed | Not listed | Not listed | Attached to permanent structure on premises | Not listed | Unlock | Sec. 16-7-20(11); Sec. 16-7-60(9) |
PermitPal covers all 5 zoning districts in Keenesburg. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Keenesburg
- It shall be unlawful to erect a sign without a building permit as provided in the ordinance.
- Signs or sign structures shall not be erected in such a manner that a portion of their surface or supports will interfere with the free use of any fire escape, exit or standpipe.
- Signs shall not obstruct openings to the extent that light or ventilation is reduced to a point below that required by the Uniform Building Code.
- Signs or sign structures shall not project into public rights-of-way or alleys.
- Signs shall not project within two feet of the curb line or the right-of-way line.
- Signs shall not project over driveways, parking lots, or similar areas of vehicular travel below a height of fourteen feet above grade.
- Signs shall not project over pedestrian ways below a height of eight feet above grade.
- All signs must be maintained in good structural and visually attractive condition at all times, and kept neatly painted, including all structural supports and metal trim.
- It is unlawful to allow any sign or portion of a sign to exist which is dilapidated or hazardous.
- Mechanical or electrical appurtenances, such as 'revolving beacons' obviously designed to compel attention, are prohibited.
- Flashing red, green or amber signs located within one hundred feet of an intersection are prohibited.
- Any sign or portion of a sign that utilizes an exposed incandescent or high intensity lamp (except neon) projecting light onto adjoining property or right-of-way is prohibited.
- Off-premises advertising devices (stationary signs advertising goods/services not sold/conducted on premises) are prohibited.
- Roof signs are prohibited.
- Advertising signs in the public right-of-way are prohibited.
- Signs attached to utility poles, traffic sign poles or any other sign causing a traffic hazard are prohibited.
- Signs or sign structures shall be placed in or upon private property only; not on public property, unless authorized.
- Special signs shall not be allowed to be placed on public rights-of-way.
- Combustible materials (other than approved plastics) shall not be used in the construction of electric signs.
Exempt Signs in Keenesburg
- Address signs are exempt from permit requirements.
- Commemorative signs are exempt from permit requirements.
- Community event signs are exempt from permit requirements.
- Community Facility Signs are exempt from permit requirements.
- Contractor signs are exempt from permit requirements.
- Directional on-site signs are exempt from permit requirements.
- Flag, pennant or insignia signs are exempt from permit requirements.
- Holiday decorations are exempt from permit requirements.
- Incidental signs are exempt from permit requirements.
- Political signs are exempt from permit requirements.
- Prohibited activities signs (such as 'No hunting') are exempt from permit requirements.
- Public phone signs are exempt from permit requirements.
- Public signs are exempt from permit requirements.
- Real estate signs are exempt from permit requirements.
- Religious or ideological signs are exempt from permit requirements.
- Residential complex or subdivision identification signs not exceeding size limits (30 or 50 sq. ft. depending on roadway type) are exempt from permit requirements.
- Special signs not exceeding sixteen square feet are exempt from permit requirements.
- Temporary signs are exempt from permit requirements.
- Window signs are exempt from permit requirements.
Sign Plan & Submission Notes for Keenesburg
- A building permit is required prior to the installation or erection of any sign structure in all zones, unless exempt as listed in Section 16-7-60.
- Signs in PUD zoned districts are subject to review as required in Section 16-7-80 (variance/special permit process); signs reviewed in conjunction with the final PUD plan review count as fulfilling this requirement.
- Variances/special permits for exceptions to size, height, location, and quantity of signs (or for special/temporary signs) require filing a written request with the Town Clerk, a public hearing before the Board of Trustees, and must meet specified findings.
- No variances will be granted for the Interstate 76 zone; all signage requirements must be met.
- Special permits are processed through the Board of Trustees with a mandatory public hearing and time limits for actions.
Source: municode municipal code