Sign Regulations in Mt. Crested Butte Town, Colorado
Mt. Crested Butte Town, Colorado has specific sign regulations covering 15 sign types across 6 zoning districts. Regulated sign types include Freestanding Sign, Exempt Sign, Statuary Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Mt. Crested Butte Town, Colorado
Sample Sign Requirements in Mt. Crested Butte Town
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Freestanding Sign | 7 ft | 10 sq ft | See location_of_sign |
| Wall Sign | Not higher than 2nd floor for multi-level, nor above ground-level wall area for single-level; never above 25 ft. | 20 sq ft or 3% building elevation | Not listed |
| Awning Sign | Not listed | 6 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
15
- Freestanding Sign
- Exempt Sign
- Statuary Sign
- Wall Sign
- +2 more types
Zoning Districts
6
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
Other Cities in Colorado
Frequently Asked Questions
In Mt. Crested Butte Town, the height limit for Freestanding Sign in the High Density Multiple-Family District (HDMF), Residential Portions of a PUD is 7 ft (Sec. 16-52(f)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Mt. Crested Butte Town require a permit. From the submission notes on this page: An amendment to the comprehensive sign plan shall be submitted upon any change in use or ownership requiring a change in the previously approved comprehensive sign plan. Run a code check for an exact address to see the permit requirements for that zone.
Mt. Crested Butte Town's sign code covers 15 sign types, including Freestanding Sign, Exempt Sign, Statuary Sign, and Wall Sign. Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Special Event Signs located within the permitted event area (Special event sign outside of the permitted event area requires a permit. The zoning administrator may waive the permit fee). The full list is on this page.
This page doesn't list a single setback distance for signs in Mt. Crested Butte Town. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Rules in Mt. Crested Butte Town's sign ordinance that cover digital, changing, or flashing signs: Flashing, animated or rotating signs, except for dials and gauges animated to the extent necessary to display correct information. Run a code check for an exact address to see the rules for that zone.
Ready to Research Mt. Crested Butte Town Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Mt. Crested Butte Town, Colorado, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Mt. Crested Butte Town, Colorado Sign Rules at a Glance
Mt. Crested Butte Town, Colorado regulates 15 sign types across 6 zoning districts. Freestanding Signs in the Recreational and Open Space District are capped at 7 ft tall and 10 sq ft (Sec. 16-72(d)). Most commercial signs in Mt. Crested Butte Town require a permit.
Detailed Sign Ordinance Requirements for Mt. Crested Butte Town, Colorado
Sign Rules by Zoning District in Mt. Crested Butte Town (6 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Single-Family Residential District (SFR), Low Density Multiple-Family District (LDMF) | 5 | 7 ft | 20 sq ft or 3% building elevation | Not listed |
| High Density Multiple-Family District (HDMF), Residential Portions of a PUD | 10 | 7 ft | 36 sq ft | Not listed |
| Business District, Commercial District, Business and Commercial Portions of a PUD | 11 | 7 ft | 36 sq ft | Not listed |
| Recreational and Open Space District | 6 | 7 ft | 36 sq ft | Not listed |
| Town's Rights-of-Way | 4 | 7 ft | 36 sq ft | Not listed |
| General Regulations For All Zones | 3 | 40 ft (flagpole) | 40 sq ft | Not listed |
Zone-by-Zone Sign Requirements in Mt. Crested Butte Town(sample of 3 of 6 zones)
High Density Multiple-Family District (HDMF), Residential Portions of a PUD
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | Not listed | 6 sq ft | Not listed | Not listed | 1 | Awnings mounted at least 15 ft above vehicular ROW, 8 ft above pedestrian walkway; any valance may be at least 7 ft above pedestrian walkway. | Not listed | Unlock | 16-52(c) |
| Canopy Sign | Not listed | 6 sq ft | Not listed | Not listed | 1 | On canopy | Not listed | Unlock | 16-52(d) |
| Under Canopy Sign | Not listed | 6 sq ft | Not listed | Not listed | 1 | Minimum 15 ft above vehicular ROW, 8 ft above pedestrian walkway. | Not listed | Unlock | 16-52(e) |
| Freestanding Sign | 7 ft | 10 sq ft | Not listed | See location_of_sign | 1 | No closer than 6 ft to street ROW or pedestrian walkway, no projection into ROW; no closer than 5 ft to side lot line or projection into adjacent lot; On corner lot, not within 35 ft triangle, must have clear air space 30 in to 8 ft. | Not listed | Unlock | 16-52(f) |
| Wall Sign | Not above 2nd floor in multi-level, nor above ground-level wall in single-level, never above 25 ft. | 20 sq ft or 3% building elevation | Not listed | Not listed | Not listed | On building, must not interrupt architectural projections. | Not listed | Unlock | 16-52(g) |
| Projecting Sign | Not listed | 6 sq ft | Not listed | See location_of_sign | Per entrance | On building elevation with access point. Max projection 5 ft from building face, not more than 1/2 setback dimension into required setback or 1/4 into required distance between buildings. When attached to balcony, cannot extend past edge. Min 15 ft above vehicular ROW, 8 ft above pedestrian walkway. | Not listed | Unlock | 16-52(h) |
| Banner | Not listed | 36 sq ft | Not listed | Not listed | Not listed | Minimum clearance 15 ft above vehicular ROW, 8 ft above pedestrian walkway. | Not listed | Unlock | 16-52(i) |
| Window Sign | Not listed | Not listed | Not listed | Not listed | 1 per window | On window | Not listed | Unlock | 16-52(j) |
Business District, Commercial District, Business and Commercial Portions of a PUD
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign | Not listed | 6 sq ft | Not listed | Not listed | Not listed | Awnings mounted at least 15 ft above vehicular ROW, 8 ft above pedestrian walkway; any valance may be 7 ft above pedestrian walkway. | Not listed | Unlock | 16-62(c) |
| Projecting Sign | Not listed | 6 sq ft | Not listed | See location_of_sign | Per entrance | On building elevation with access. Max projection 5 ft from building, not more than 1/2 setback dimension into required setback or 1/4 into required distance between buildings. If attached to balcony, cannot extend beyond edge. Min 15 ft above vehicular ROW, 8 ft above pedestrian walkway. | Not listed | Unlock | 16-62(d) |
| Canopy Sign | Not listed | 6 sq ft | Not listed | Not listed | 1 | On canopy | Not listed | Unlock | 16-62(e) |
| Under Canopy Sign | Not listed | 6 sq ft | Not listed | Not listed | 1 | Min 15 ft above vehicular ROW, 8 ft above pedestrian walkway. | Not listed | Unlock | 16-62(f) |
| Freestanding Sign | 7 ft | 10 sq ft | Not listed | See location_of_sign | 1 | No closer than 6 ft to street ROW/pedestrian walkway. No part projecting into ROW. Not closer than 5 ft to side lot line/adjacent lot. On corner lot, not within triangle measured 35 ft from each ROW corner, must have clear air space 30 in to 8 ft. | Not listed | Unlock | 16-62(g) |
| Wall Sign | Not above 2nd floor (multi-level), or above ground level wall area (single-level), never above 25 ft. | 20 sq ft or 3% building elevation | Not listed | Not listed | Not listed | On building, must not interrupt architectural projections. | Not listed | Unlock | 16-62(h) |
| Banner | Not listed | 36 sq ft | Not listed | Not listed | Not listed | Min 15 ft clearance above vehicular ROW, 8 ft above pedestrian walkway. | Not listed | Unlock | 16-62(i) |
| Sandwich Board Sign | Not listed | 8 sq ft per side | Not listed | Not listed | See sign_size_restrictions | Within 10 ft of access point; outside only during hours of operation. | Not listed | Unlock | 16-62(k) |
Recreational and Open Space District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Exempt Sign | Not listed | Not listed | Not listed | Not listed | Not listed | Not listed | Not listed | Unlock | 16-72(a), 16-3 |
| Statuary Sign | Not listed | Not listed | Not listed | Not listed | Not listed | Not listed | Not listed | Unlock | 16-72(b) |
| Banner | Not listed | 36 sq ft | Not listed | Not listed | Not listed | Min. clearance 15 ft above vehicular ROW, 8 ft above pedestrian walkway. | Not listed | Unlock | 16-72(c) |
| Freestanding Sign | 7 ft | 10 sq ft | Not listed | See location_of_sign | Not listed | No closer than 6 ft to street ROW or walkway, no projection into ROW, not closer than 5 ft to side lot, on corner lot not within 35 ft triangle, must have clear air space from 30 in to 8 ft. | Not listed | Unlock | 16-72(d) |
| Wall Sign | Not higher than 2nd floor (multi-level) or above ground-level wall (single-level), never above 25 ft. | 20 sq ft or 3% building elevation | Not listed | Not listed | Not listed | On building, must not interrupt architectural projections. | Not listed | Unlock | 16-72(e) |
| Sandwich Board Sign | Not listed | 8 sq ft per side | Not listed | Not listed | Not listed | Displayed outside only during hours of operation. | Not listed | Unlock | 16-72(f) |
PermitPal covers all 6 zoning districts in Mt. Crested Butte Town. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Mt. Crested Butte Town
- A sign which is structurally unsafe, or constitutes a hazard to the safety or health of any person by reason of inadequate maintenance or dilapidation, or which is not kept in good repair or is capable of causing electrical shocks to persons likely to come in contact with it.
- Signs imitating or resembling official traffic or government signs or signals, or signs other than government signs using any words, phrases, symbols or characters implying the existence of danger or the need for stopping or maneuvering a motor vehicle or in any other way creating an unsafe distraction for motor vehicle operators.
- Flashing, animated or rotating signs, except for dials and gauges animated to the extent necessary to display correct information.
- Signs that obstruct the view of motor vehicle operators entering a public roadway from any parking area, service drive, private driveway, alley or other thoroughfare, or which obstruct free ingress to or egress from a required door, window, fire escape or other required exitway.
- Non-conforming signs.
- Signs erected on a public right-of-way without proper authorization.
- Wind-driven signs.
- Searchlights.
- Roof signs.
- Signs that swing.
- Signs which require guy wires for support.
- Vehicular signs.
- Billboards.
- Snipe signs.
- Luminescent signs, exterior, or as window signs greater than four square feet.
- Walking signs.
- Signs containing an obscene statement, word or picture describing or depicting sexual activities or sexual anatomical areas.
- Signs with messages that are intended to incite imminent unlawful action(s).
Exempt Signs in Mt. Crested Butte Town
- Government signs.
- Wayfinding signs.
- Flags (provided flags do not exceed 40 square feet in size and no flagpole is higher than 40 feet above the ground).
- Temporary signs, except for those placed in the town's rights-of-way. Unless expressly allowed elsewhere, temporary signs shall be removed upon completion of the purpose for which they were erected.
- Yard signs with an aggregate maximum of 24 square feet, and no individual sign more than six square feet. Yard signs may not exceed a maximum height of four feet measured from the ground.
- Signs not visible beyond a property line.
- Special Event Signs located within the permitted event area (Special event sign outside of the permitted event area requires a permit. The zoning administrator may waive the permit fee).
Sign Plan & Submission Notes for Mt. Crested Butte Town
- The owner, builder or developer of a new building or structure designed for occupation by two or more separate occupants or businesses shall present to the planning commission at the time of design review or site specific review approval a comprehensive sign plan showing proposed sign locations, types and methods of allocating signs and allowances to tenants' use.
- An amendment to the comprehensive sign plan shall be submitted upon any change in use or ownership requiring a change in the previously approved comprehensive sign plan.
- The zoning administrator will not accept any sign permit application not in accordance with the current comprehensive sign plan.
- For mixed use or multiple-business buildings, a comprehensive sign plan shall be submitted to the planning commission at the time of design review or site specific review.