Casselberry, Florida has specific sign regulations covering 11 sign types across 3 zoning districts. Regulated sign types include Flag (on pole or bracket), Ground Sign, Facade Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 7, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Casselberry, Florida

Sample Sign Requirements in Casselberry

Sign TypeMax HeightMax AreaSetback
Ground Sign15 feet above the crown of the road100 sq ft per signNo part of sign closer than 10 feet to paved surface of road. At property line but not over it.
Facade SignLower of building roofline or fasciaSingle tenant: 350 sq ft. Multi-tenant: 250 sq ft per individual tenant unit (first floor), 150 sq ft (individual unit above ground floor, or 1 sq ft/linear ft, not to exceed 150 sq ft)May not project over property line.
Window Sign15 ft (per overall wall height limit)25% of glass area per windowNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for CasselberryFull Coverage

Sign Types Covered

11

  • Flag (on pole or bracket)
  • Ground Sign
  • Facade Sign
  • Window Sign
  • +2 more types

Zoning Districts

3

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Casselberry

City WebsiteMunicipal Code3 permit application links available

Frequently Asked Questions

In Casselberry, the height limit for Ingress and Egress Ground Sign at Subdivision Entrances in the Residential zoning districts is 15 ft above crown of adjacent road (Sec. 3-16.3.E). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Casselberry require a permit. From the submission notes on this page: Permanent signs larger than six square feet require a building permit, which includes submittal and approval of a sign plan (Section 3-16.10). Run a code check for an exact address to see the permit requirements for that zone.

Casselberry's sign code covers 11 sign types, including Flag (on pole or bracket), Ground Sign, Facade Sign, and Window Sign. Most commercial signs need a permit. The ordinance lists 10 exemptions. One of them: Temporary signs do not require a building permit (however, registration is required for temporary commercial signs except for sale/lease signs). The full list is on this page.

In Casselberry, Ingress and Egress Ground Sign at Subdivision Entrances in the Residential zoning districts must be set back at least 25 ft from any intersection of street rights-of-way (Sec. 3-16.3.E). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Casselberry's sign ordinance that cover digital, changing, or flashing signs: Animated, revolving, or moving signs are prohibited, except that manually changeable copy signs are allowed, and a premises is allowed a maximum of three static LED signs no more than 4.5 sq. ft. with photocells that display a maximum of four characters. Electronic display type signs are prohibited. Signs that use objects that digitally or electronically produce color/black and white images similar to a television screen, or multi-vision display devices capable of presenting two or more images or ad copy sequentially by rotating cylinders are prohibited. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Casselberry Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Casselberry, Florida, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Casselberry, Florida Sign Rules at a Glance

Casselberry, Florida regulates 11 sign types across 3 zoning districts. Ingress and Egress Ground Sign at Subdivision Entrances in the Residential zoning districts are capped at 15 ft above crown of adjacent road and 48 sq ft, set back at least 25 ft from any intersection of street rights-of-way (Sec. 3-16.3.E). Most commercial signs in Casselberry require a permit.

Detailed Sign Ordinance Requirements for Casselberry, Florida

Sign Rules by Zoning District in Casselberry (3 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Commercial, office, institutional and industrial zoning districts715 feet above the crown of the roadSingle tenant: 350 sq ft. Multi-tenant: 250 sq ft per individual tenant unit (first floor), 150 sq ft (individual unit above ground floor, or 1 sq ft/linear ft, not to exceed 150 sq ft)Not listed
Residential zoning districts415 ft above crown of adjacent road48 sq ftNot listed
General Regulations For All Zones1Not listedNot listedNot listed

Zone-by-Zone Sign Requirements in Casselberry

Commercial, office, institutional and industrial zoning districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground Sign15 feet above the crown of the road100 sq ft per signNot listedNo part of sign closer than 10 feet to paved surface of road. At property line but not over it.See above in additional requirements.May be erected at property line but no part projects over property line and must be at least 10 feet from paved road surface. No projection over public property.Not listedUnlockSec. 3-16.3.C.4.a, 3-16.3.C.3.a, 3-16.3.C.5.a, 3-16.3.C.6, 3-16.7.C, 3-16.10
Facade SignLower of building roofline or fasciaSingle tenant: 350 sq ft. Multi-tenant: 250 sq ft per individual tenant unit (first floor), 150 sq ft (individual unit above ground floor, or 1 sq ft/linear ft, not to exceed 150 sq ft)Not listedMay not project over property line.No limit to number at ground floor or with exterior access above ground floor, as long as aggregate sq ft not exceeded. Interior access multi-story: only single sign above ground floor.On wall of building, may not protrude beyond property lineNot listedUnlockSec. 3-16.3.C.2, 3-16.3.C.3.c.2, 3-16.3.C.5.b, 3-16.10
Window Sign15 ft (per overall wall height limit)25% of glass area per windowNot listedNot listedNo number limit specified; aggregate area per window applies.Placed on or inside window panes or doorsNot listedUnlockSec. 3-16.3.C.3.b, 3-16.7.C.8
Ingress and Egress Ground Sign at Entrances4 ft above crown of the road6 sq ftNot listedMust not project over the property line and be at least 10 ft from the paved road surface.See above.At property entrances. Number: Max 2 per premises (4 if premises has 2 road frontages)Not listedUnlockSec. 3-16.3.C.3.c, 3-16.3.C.4.b, 3-16.3.C.5.c
Temporary Signs (Ground/Wall)10 feet (ground), 15 feet (wall, including window signs)32 sq ft per sign; maximum aggregate surface area on parcel: 128 sq ftNot listedMinimum 3 ft from right-of-way; min spacing 10 ft between signs4 per parcel (non-residential); 2 per business (1 banner/feather/inflatable).Ground signs min 3 ft from right-of-way, min 10 ft between temporary ground signs. No temporary signs allowed on public right-of-way.Not listedUnlockSec. 3-16.4 Table 3-16.4
Drive-through Lane Display Sign8 ft40 sq ftNot listedNot listedOne per drive-through laneAt drive-through lanesNot listedUnlockSec. 3-16.7.E
Flag (on pole or bracket)Not listed24 sq ft per flag (per side)Not listedNot listedMax 6 flags on flagpoles (nonresidential >0.5 acre); 2 per bracket (max 2 brackets per principal structure)Flagpoles on site, brackets on principal structureNot listedUnlockSec. 3-16.3.G

Residential zoning districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Permanent On-premises SignNot listed6 sq ftNot listedNot listedNot listedOn premisesNot listedUnlockSec. 3-16.3.D, 3-16.3.B.1 and .2, 3-16.7.C.2
Ingress and Egress Ground Sign at Subdivision Entrances15 ft above crown of adjacent road48 sq ftNot listedMinimum 25 ft from any intersection of street rights-of-way.One per subdivision entrance.At each entrance to subdivision; sign must be minimum 25 ft from intersection of any street rights-of-way.Not listedUnlockSec. 3-16.3.E
Temporary Sign (Ground/Wall/Window)6 ft (ground), 15 ft (wall/window).6 sq ft per sign; up to 30 sq ft aggregate per parcelNot listed3 ft from right-of-way5 per parcelOn private property, min 3 ft from edge of right-of-way (for ground signs)Not listedUnlockSec. 3-16.4 & Table 3-16.4
Flag (on pole or bracket)Not listed24 sq ft per flag (per side)Not listedNot listed2 per pole, 2 per bracket; see restrictions aboveFlagpole on site or bracket attached/placed to principal structureNot listedUnlockSec. 3-16.3.G

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Prohibited SignNot listedNot listedNot listedNot listedNot listedNot listedNot listedUnlockSec. 3-16.5 (off-premises signs), 3-16.8 B, 3-16.7.C (illumination rules); also see 3-16.9 (nonconforming), 3-16.11 (maintenance), 3-16.12-16.16 (content neutrality), etc.

Run a code check for your exact address to get the zone that applies to your property, plus illumination rules, size formulas, and permit requirements for every sign type in Casselberry with a free PermitPal account.

Run a free code check

Prohibited Signs in Casselberry

  • Off-premises signs are prohibited.
  • Snipe signs (signs attached to public property, utility poles, trees, or placed in public rights-of-way) are prohibited.
  • Any sign not permitted or defined within Article XVI is prohibited.
  • Any sign which obstructs the view at intersections or traveled ways is prohibited.
  • Motor vehicle signs are prohibited except when the vehicle is actively engaged in business (deliveries, pickups, etc.) and primarily used for something other than signage.
  • Roof signs are prohibited.
  • Animated, revolving, or moving signs are prohibited, except that manually changeable copy signs are allowed, and a premises is allowed a maximum of three static LED signs no more than 4.5 sq. ft. with photocells that display a maximum of four characters.
  • Electronic display type signs are prohibited.
  • Signs that contain lighting in violation of Section 3-10.2(6) or which impair motorists' vision or distract drivers are prohibited.
  • Signs that use objects that digitally or electronically produce color/black and white images similar to a television screen, or multi-vision display devices capable of presenting two or more images or ad copy sequentially by rotating cylinders are prohibited.
  • Signs located in the right-of-way are prohibited.
  • Wall wrap signs are prohibited.
  • Abandoned or discontinued signs are prohibited and must be removed.
  • Signs (other than traffic devices) using the words 'stop' or 'danger', or which imply the need to stop or presence of danger or imitate traffic devices near roadways, are prohibited.
  • Signs that obstruct or conceal official traffic control devices or signals are prohibited.
  • Streamer signs and pennants (banners of lightweight material suspended, typically moving in the wind) are prohibited.
  • Signs containing objects that flash, move, rotate, scintillate, blink, flicker, or vary in color intensity are prohibited.
  • Illuminated signs within 50 feet of a single-family residential use or zone may not be internally illuminated.
  • Temporary sign illumination is prohibited (except for trailer signs).
  • Any sign not maintained in a state of good repair and that creates a public safety threat is prohibited.
  • Signs larger than six square feet require a building permit (displaying a flag does not require a building permit).
  • Permanent sign illumination that leaves illumination devices exposed to public view is prohibited, except neon tubing for window signs.
  • Wall wrap signs, window wrap signs, and signs made from fabric or similar material that drape over a building/wall/window are prohibited.

Exempt Signs in Casselberry

  • Government signs on government property, including traffic control devices, are exempt.
  • Signs required or installed by a government agency on private property are exempt.
  • Notices required to be posted by law or ordinance on private property are exempt from regulation as a sign.
  • Temporary signs do not require a building permit (however, registration is required for temporary commercial signs except for sale/lease signs).
  • Temporary signs with noncommercial messages, regardless of size, do not require an application to the Community Development Department but must conform to Table 3-16.4.
  • Temporary commercial signs sized six square feet or less do not require a fee.
  • Address signs (two sq. ft. for residential, four sq. ft. for non-residential) are exempt from permit requirements.
  • Flags displayed on permitted flagpoles or flag brackets are exempt from building permit requirements.
  • For residential uses: permitted on-premises signs up to six square feet and one flagpole with up to two flags are exempt.
  • Street address signs as required for 911 purposes are allowed without permit.

Sign Plan & Submission Notes for Casselberry

  • A sign plan is required for permanent signs as part of the building permit application process (Section 3-16.10). The application must include: a summary table listing location, type, and area of all existing and proposed signs; fully dimensioned elevation drawing of any proposed sign; and, for facade signs, an elevation of the building showing placement.
  • Permanent signs larger than six square feet require a building permit, which includes submittal and approval of a sign plan (Section 3-16.10).
  • Temporary signs do not require a building permit or sign plan but commercial temporary signs (except for sale/lease) must be registered with the Community Development Department.
  • Article XIII, Section 3-13.9, requires submission of a landscape plan (which may include signage and sign landscaping) as part of site plan/Development Review Committee approval.
  • For appeals or variances related to sign permits or administrative interpretation, applications are reviewed by the Planning and Zoning Commission as per Section 3-16.13.
  • Compliance with sign standards is confirmed upon permit review, including a requirement to provide wind load calculations, construction, electrical, and site details for signs.

Source: municode municipal code