Sign Regulations in Clermont, Florida
Clermont, Florida has specific sign regulations covering 36 sign types across 8 zoning districts. Regulated sign types include Tenant Wall or Marquee Sign, Tenant Projecting Sign, Platted Lot Identification Ground Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 7, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Clermont, Florida
Sample Sign Requirements in Clermont
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Ground Sign | Local: 6 ft; Collector: 8 ft; SR 50/US 27: 10 ft (+12 in ornamental) | Arterial: 60 sq ft/face; Collector: 48 sq ft/face; Internal: 32 sq ft/face | 5 ft (ROW), 10 ft (side/rear), 20 ft (residential); corner lots: 50 ft from intersecting ROW on Highways 50/27, 30 ft on other streets |
| Wall Sign - Primary | Not listed | 200 sq ft | Not listed |
| Wall Sign - Secondary | Not listed | Up to 50% of primary wall sign | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
36
- Tenant Wall or Marquee Sign
- Tenant Projecting Sign
- Platted Lot Identification Ground Sign
- Building Wall Sign (End of Building)
- +2 more types
Zoning Districts
8
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Clermont
Other Cities in Florida
Frequently Asked Questions
In Clermont, the height limit for Complex or Park Identification Ground Sign (<50,000 sf) in the Industrial Complexes, Industrial Parks zoning districts is 15 ft (Sec. 117-15(c)(2)a). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Clermont require a permit. From the submission notes on this page: Application for a sign permit requires submission of a plan, sketch, blueprint or similar presentation showing all pertinent structural details of the proposed sign, and a site plan showing existing and proposed signage (Sec. 117-6(a)(5)-(6)). Run a code check for an exact address to see the permit requirements for that zone.
Clermont's sign code covers 36 sign types, including Tenant Wall or Marquee Sign, Tenant Projecting Sign, Platted Lot Identification Ground Sign, and Building Wall Sign (End of Building). Most commercial signs need a permit. The ordinance lists 11 exemptions. One of them: Signs described in section 117-7 (Exempt Signs) are exempt from sign permit requirements, provided they do not create a hazard and meet construction and electrical code requirements. The full list is on this page.
In Clermont, Complex or Park Identification Ground Sign (<50,000 sf) in the Industrial Complexes, Industrial Parks zoning districts must be set back 25 ft from side lot lines, 5 ft right-of-way (Sec. 117-15(c)(2)a). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Clermont's sign ordinance that cover digital, changing, or flashing signs: Signs using rotating or flashing signal lamps similar to those used on emergency vehicles are prohibited. Bull's eye, sequential or flashing lights designed to focus attention to a single point are prohibited. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Clermont Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Clermont, Florida, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Clermont, Florida Sign Rules at a Glance
Clermont, Florida regulates 36 sign types across 8 zoning districts. Platted Lot Identification Ground Signs in the Office Complexes, Office Parks zoning districts are capped at 8 ft tall, 32 sq ft, and 20 ft wide, set back 25 ft from side lot lines, 5 ft right-of-way (Sec. 117-15(d)(4)). Most commercial signs in Clermont require a permit.
Detailed Sign Ordinance Requirements for Clermont, Florida
Sign Rules by Zoning District in Clermont (8 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Commercial Districts | 8 | Local: 6 ft; Collector: 8 ft; SR 50/US 27: 10 ft (+12 in ornamental) | 800 sq ft | Not listed |
| Shopping Centers | 7 | 15 ft | 128 sq ft | Not listed |
| Industrial Complexes, Industrial Parks | 7 | 15 ft | 120 sq ft | Not listed |
| Office Complexes, Office Parks | 7 | 15 ft | 120 sq ft | Not listed |
| Residential Districts (UE, R-1-A, R-1, R-2, R-3-A, R-3) | 4 | 9 ft | 32 sq ft | Not listed |
| Central Business District (CBD) | 2 | 4 ft | 6 sq ft per side (max 3 ft wide x 4 ft high, two sides) | Not listed |
| C-2, M-1 | 1 | Not listed | 64 sq ft | Not listed |
| General Regulations For All Zones | 7 | 8 ft | 50 sq ft | Not listed |
Zone-by-Zone Sign Requirements in Clermont(sample of 3 of 8 zones)
Commercial Districts
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Ground Sign | Local: 6 ft; Collector: 8 ft; SR 50/US 27: 10 ft (+12 in ornamental) | Arterial: 60 sq ft/face; Collector: 48 sq ft/face; Internal: 32 sq ft/face | 10 ft | 5 ft (ROW), 10 ft (side/rear), 20 ft (residential); corner lots: 50 ft from intersecting ROW on Highways 50/27, 30 ft on other streets | One per street frontage; second allowed under conditions | One per parcel per primary street frontage; additional on secondary frontage at 50% area of primary allowed | Not listed | Unlock | Sec. 117-15(a)(1)a |
| Wall Sign - Primary | Not listed | 200 sq ft | Not listed | Not listed | One primary per qualifying wall | Each wall parallel or perpendicular to a road/street | Not listed | Unlock | Sec. 117-15(a)(1)b.1 |
| Wall Sign - Secondary | Not listed | Up to 50% of primary wall sign | Not listed | Not listed | Up to two | Up to two walls | Not listed | Unlock | Sec. 117-15(a)(1)b.1 |
| Wall Sign (Interior-facing, Outparcels/Entrances) | Not listed | 32 sq ft max | Not listed | Not listed | One per outparcel or entrance-facing wall | Facing interior of nonresidential development | Not listed | Unlock | Sec. 117-15(a)(1)b.2 |
| Marquee Sign | Not listed | 32 sq ft | Not listed | Not listed | One per qualifying wall | Parallel or perpendicular to the street | Not listed | Unlock | Sec. 117-15(a)(1)b.3 |
| Projecting Sign | Not listed | 4 sq ft | Not listed | Not listed | One per business | Below a marquee or canopy | Not listed | Unlock | Sec. 117-15(a)(1)b.4 |
| Canopy Sign | Not listed | 10 sq ft | Not listed | Not listed | See context | Located over a building front sidewalk, parking area or similar | Not listed | Unlock | Sec. 117-15(a)(1)b.6 |
| Wall Sign (High Rise, Multiunit Centers) | Not listed | 800 sq ft | Not listed | Not listed | One per common entrance | On parapet or building wall | Not listed | Unlock | Sec. 117-15(a)(1)b.5 |
Industrial Complexes, Industrial Parks
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Complex or Park Identification Ground Sign (<50,000 sf) | 15 ft | 100 sq ft | 20 ft | 25 ft from side lot lines, 5 ft ROW | One per arterial/principal entry | One per arterial frontage/principal entry | Not listed | Unlock | Sec. 117-15(c)(2)a |
| Complex or Park Identification Ground Sign (50,000+ sf) | 15 ft | 120 sq ft | 20 ft | 25 ft from side lot lines, 5 ft ROW | One per arterial/principal entry | One per arterial/principal entry | Not listed | Unlock | Sec. 117-15(c)(2)b |
| Platted Lot Identification Ground Sign | 8 ft | 32 sq ft | 20 ft | 25 ft from side lot lines, 5 ft ROW | One per street frontage | Each street frontage | Not listed | Unlock | Sec. 117-15(c)(3) |
| Building Wall Sign (End of Building) | Not listed | 32 sq ft | Not listed | Not listed | One per end | Each end of building | Not listed | Unlock | Sec. 117-15(c)(4) |
| Tenant Wall or Marquee Sign | Not listed | 100 sq ft | Not listed | Not listed | One per business | Per business | Not listed | Unlock | Sec. 117-15(c)(5)a |
| Tenant Projecting Sign | Not listed | 4 sq ft | Not listed | Not listed | One per business | Below a marquee or canopy, per business | Not listed | Unlock | Sec. 117-15(c)(5)b |
| Directory Sign (Wall or Ground) | 8 ft (if ground directory) | 24 sq ft | Not listed | Not listed | One directory sign per building | Oriented to parking/pedestrian areas only | Not listed | Unlock | Sec. 117-15(c)(6) |
Office Complexes, Office Parks
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Complex or Park Identification Ground Sign (<25,000 sf) | 15 ft | 100 sq ft | 20 ft | 25 ft from side lot lines, 5 ft ROW | One per street frontage or principal entry | One per street frontage or principal entry | Not listed | Unlock | Sec. 117-15(d)(3)a |
| Complex or Park Identification Ground Sign (25,000+ sf) | 15 ft | 120 sq ft | 20 ft | 25 ft from side lot lines, 5 ft ROW | One per street frontage or principal entry | One per street frontage or principal entry | Not listed | Unlock | Sec. 117-15(d)(3)b |
| Platted Lot Identification Ground Sign | 8 ft | 32 sq ft | 20 ft | 25 ft from side lot lines, 5 ft ROW | One per street frontage | One per street frontage | Not listed | Unlock | Sec. 117-15(d)(4) |
| Building Wall Sign (End of Building) | Max letter height: 2 ft | 32 sq ft | Not listed | Not listed | One per end | Each end of building | Not listed | Unlock | Sec. 117-15(d)(5) |
| Tenant Wall or Marquee Sign | Not listed | 100 sq ft | Not listed | Not listed | One per business | Per business | Not listed | Unlock | Sec. 117-15(d)(6)a |
| Tenant Projecting Sign | Not listed | 4 sq ft | Not listed | Not listed | One per business | Below a marquee/canopy, per business | Not listed | Unlock | Sec. 117-15(d)(6)b |
| Directory Sign (Wall or Ground) | 8 ft (if ground directory) | 24 sq ft | Not listed | Not listed | One per internally accessed building | Oriented to parking/pedestrian areas only | Not listed | Unlock | Sec. 117-15(d)(7) |
PermitPal covers all 8 zoning districts in Clermont. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Clermont
- It is unlawful to erect, maintain, or cause to be maintained any sign that constitutes a traffic hazard or detriment to traffic safety by reason of size, location, movement, content, coloring or method of illumination.
- It is unlawful to erect, maintain, or cause to be maintained any sign which obstructs vision between pedestrians and vehicles using the public right-of-way, including those not meeting visibility requirements of the land development code.
- Signs using rotating or flashing signal lamps similar to those used on emergency vehicles are prohibited.
- Signs that resemble any official sign or marker erected by any government agency, or that by position, shape, or color could be confused with any traffic sign or signal, or conceal a traffic control device, are prohibited.
- Signs using lights or illuminations that flash, move, rotate, scintillate, blink, flicker, or vary in intensity or color are prohibited.
- Signs within 50 feet of public rights-of-way or 100 feet of traffic control lights that contain red or green lights that could be confused with traffic signals are prohibited.
- Signs using words or traffic control symbols so as to interfere with, mislead or confuse traffic, such as 'stop,' 'look,' 'caution,' 'danger,' or 'slow,' are prohibited.
- Signs that are of such intensity or brilliance as to cause glare or impair the vision of motorists, cyclists, or pedestrians, or are a hazard or nuisance to property occupants, are prohibited.
- Signs located so as to interfere with clear sight distances of motor vehicles or pedestrian traffic are prohibited.
- Signs in violation of the Florida Building Code or electrical codes adopted by the city are prohibited.
- Signs with visible moving, revolving, or rotating parts or visible mechanical movement (except for traditional barber poles) are prohibited.
- Signs with optical illusions of movement by design are prohibited.
- Wind signs (such as pennants, ribbons, spinners, streamers, or captive balloons) are prohibited.
- Signs or sign structures that interfere with fire escapes, emergency exits, standpipes, windows, doors, or ventilation, or prevent free roof passage, are prohibited.
- Signs displaying any statement, word, character, or illustration of an obscene, indecent, or immoral nature are prohibited.
- Signs containing any lighting or control mechanism that causes unreasonable interference with radio, television, or other communication signals are prohibited.
- Banner signs, except as specifically allowed by the ordinance, are prohibited.
- Banners or signs placed across any street or public way without written approval of the administrative official are prohibited.
- Signs with fluorescent colors are prohibited.
- Bull's eye, sequential or flashing lights designed to focus attention to a single point are prohibited.
- Signs that incorporate projected images, emit audible sounds, odors, or visible matter (smoke, steam), use live animals, or contain handmade, nonprofessional features not specifically exempted are prohibited.
- Signs in any public right-of-way or on public utility poles or trees are prohibited.
- Signs on seawalls and retaining walls are prohibited.
- Abandoned signs are prohibited.
- Roof signs are prohibited.
- Off-site signs, except as expressly permitted, are prohibited.
- Signs painted or printed on any curbstone, flagstone, pavement, sidewalk or street (except house numbers and traffic control signs) are prohibited.
- Strings of light bulbs on nonresidential structures for commercial purposes, other than holiday decorations, are prohibited.
- Any other sign not specifically permitted or exempted by this chapter is prohibited.
- Ancillary signage attached to a permitted sign's face, frame, or support structure, including stickers or banners, is prohibited.
- Human signs advertising off-site businesses, goods, or services are prohibited.
- Signs of any type constructed, placed or erected in any space used to meet city minimum parking requirements are prohibited.
- Signs that increase the size of a vehicle in any direction are prohibited except as approved by the administrative official.
- Illuminated signs on vehicles are prohibited except for 'Taxi' or 'Ambulance' or destination signs on public vehicles.
- Vehicles may not be painted or marked with directional information for use as off-site signs.
Exempt Signs in Clermont
- Signs described in section 117-7 (Exempt Signs) are exempt from sign permit requirements, provided they do not create a hazard and meet construction and electrical code requirements.
- Repair, maintenance, or repainting of existing conforming or lawfully nonconforming signs is exempt from permit requirements.
- Replacement of an existing sign panel or face on a conforming or lawfully nonconforming sign is exempt from permit requirements.
- Signs on vehicles that do not increase vehicle size and are not positioned/used as on-site signs are exempt from this chapter.
- Legal notices and official instruments are exempt.
- Signs necessary to promote health, safety and general welfare or regulatory, statutory, traffic control, or directional signs erected on public property by government agencies are exempt.
- Holiday lights and seasonal decorations displayed during customary times are exempt.
- Decorative flags and bunting for a celebration or commemoration authorized by the city council are exempt for the prescribed period.
- National, state, city or corporate flags as described in section 117-7 are exempt if not used to attract attention for commercial purposes (subject to number, size, and placement restrictions in the code).
- Noncommercial signs (other than political signs), subject to number, area, setback, height, and illumination restrictions, are exempt from permit requirements.
- Specific types of instructional, memorial, bulletin board, menu, awning, real estate, directory, ground identification, and sandwich board signs as described in section 117-7 are exempt from permit requirements, subject to stated restrictions on size, content, and placement.
Sign Plan & Submission Notes for Clermont
- Application for a sign permit requires submission of a plan, sketch, blueprint or similar presentation showing all pertinent structural details of the proposed sign, and a site plan showing existing and proposed signage (Sec. 117-6(a)(5)-(6)).
- All signage must be submitted to the planning and development services department for review and approval prior to building permit application (Figure 117-25A).
- An application and site plan must be submitted to the planning and development services department for banner/sign approval for temporary events and grand openings; approval is required prior to installation (Sec. 117-8(11)a, (11)d.2, (11)d.10-11).
- Shopping center, commercial center, industrial park, and office park signage is subject to review and approval by the city as part of the site development plan review process (Sec. 117-15(b)(1), (c)(1), (d)(3)).
- Variance requests must be referred to the city council (Sec. 117-5(b), 117-4).
- A permit and graphic/site plan are required for mural art projects prior to installation; review and approval by designated staff is mandatory (Sec. 117-26(a)(4)).
Source: municode municipal code