Questions? Call us at (262) 218-2915

Sign Regulations in Fort Pierce, Florida

Fort Pierce, Florida has specific sign regulations covering 12 sign types across 8 zoning districts. Regulated sign types include Wall Sign, Ground Sign, Temporary Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: March 17, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Fort Pierce, Florida

Sample Sign Requirements in Fort Pierce

Sign TypeMax HeightMax AreaSetback
Temporary SignNot listed8 square feetNot listed
Wall SignNot listed1 square footNot listed
Ground SignNot listed18 square feetNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Fort PierceFull Coverage

Sign Types Covered

12

  • Wall Sign
  • Ground Sign
  • Temporary Sign
  • Directional Sign
  • +2 more types

Zoning Districts

8

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Fort Pierce

City WebsiteMunicipal Code3 permit application links available

Frequently Asked Questions

In Fort Pierce, the height limit for Ground Sign in the Office commercial and Edgartown Settlement zoning districts (C-1, ES) is 6 feet (Sec. 117-7(3)(a)(3)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Fort Pierce require a permit. From the submission notes on this page: All plans and layouts for a sign or advertising structure shall be accompanied by an application which shall be filed with the building department in accordance with chapter 103 of this Code prior to the issuance of any permit. Run a code check for an exact address to see the permit requirements for that zone.

Fort Pierce's sign code covers 12 sign types, including Wall Sign, Ground Sign, Temporary Sign, and Directional Sign. Most commercial signs need a permit. The ordinance lists 8 exemptions. One of them: Murals. The full list is on this page.

We haven't published Fort Pierce's sign setback rules on this page yet. Run a code check for an exact address to see them.

Fort Pierce's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.

AI-Powered Research

Ready to Research Fort Pierce Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Fort Pierce, Florida, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Fort Pierce, Florida Sign Rules at a Glance

Fort Pierce, Florida regulates 12 sign types across 8 zoning districts. Ground Signs in the Office commercial and Edgartown Settlement zoning districts (C-1, ES) are capped at 6 feet tall and 48 square feet (Sec. 117-7(3)(a)(3)). Most commercial signs in Fort Pierce require a permit.

Detailed Sign Ordinance Requirements for Fort Pierce, Florida

Sign Rules by Zoning District in Fort Pierce (8 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Single-family residential zoning districts (E-1, E-2, E-3, R-1, R-2, R-3)3Not listed18 square feetNot listed
Multi-family residential zoning districts (R-4, R-4A, R-5)56 feet for ground signs32 square feet on lots of one acre or more, 8 square feet on all other parcelsNot listed
Office commercial and Edgartown Settlement zoning districts (C-1, ES)56 feet48 square feetNot listed
Limited commercial and open space/recreational zoning districts (C-2, C-5, C-6, OS-1, OS-2, A-1, A-2)8Not listed32 square feetNot listed
General commercial and industrial zoning districts (C-3, C-4, CP, I-1, I-2, I-3)9Not listed32 square feetNot listed
Planned development and planned unit redevelopment zoning district (PD, PUR)1Not listed32 square feetNot listed
I-95 and turnpike interchange district165 feetNot listedNot listed
General Regulations For All Zones525 feet400 square feetNot listed

Zone-by-Zone Sign Requirements in Fort Pierce(sample of 3 of 8 zones)

Office commercial and Edgartown Settlement zoning districts (C-1, ES)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Temporary SignNot listed32 square feetNot listedNot listedNot listedMinimum 25 feet apartNot listedUnlockSec. 117-7(3)(a)(1)
Wall SignNot listed2 square feetNot listedNot listed1 per tenant or occupantPer tenant or occupantNot listedUnlockSec. 117-7(3)(a)(1)
Wall SignNot listed24 square feetNot listedNot listed1 per buildingPer buildingNot listedUnlockSec. 117-7(3)(a)(2)
Ground Sign6 feet48 square feetNot listedNot listed1 per establishment or group of establishmentsMain street lot frontage of 60 linear feet or moreNot listedUnlockSec. 117-7(3)(a)(3)
Directional SignNot listed6 square feetNot listedNot listedNot listedNot listedNot listedUnlockSec. 117-7(3)(a)(4)

Limited commercial and open space/recreational zoning districts (C-2, C-5, C-6, OS-1, OS-2, A-1, A-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignNot listedNot listedNot listedNot listed1 per tenantPer tenantNot listedUnlockSec. 117-7(4)(a)(1)
Projecting SignNot listedNot listedNot listedNot listed1 per tenantPer tenantNot listedUnlockSec. 117-7(4)(a)(1)
Ground SignNot listedNot listedNot listedNot listed1 per establishment or group of establishmentsMain street lot frontage of 60 linear feet or moreNot listedUnlockSec. 117-7(4)(a)(2)
Pedestrian SignNot listed6 square feetNot listedNot listed1 per tenantPer tenantNot listedUnlockSec. 117-7(4)(a)(3)
Rear Entrance Wall SignNot listed6 square feetNot listedNot listed1 per tenantPer tenantNot listedUnlockSec. 117-7(4)(a)(4)
Window SignNot listedNot listedNot listedNot listedNot listedPer tenantNot listedUnlockSec. 117-7(4)(a)(5)
Directional SignNot listed6 square feetNot listedNot listedNot listedNot listedNot listedUnlockSec. 117-7(4)(a)(6)
Temporary SignNot listed32 square feetNot listedNot listedNot listedMinimum 25 feet apartNot listedUnlockSec. 117-7(4)(a)(7)

General commercial and industrial zoning districts (C-3, C-4, CP, I-1, I-2, I-3)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignNot listedNot listedNot listedNot listed1 per tenantPer tenantNot listedUnlockSec. 117-7(5)(a)(2)
Projecting SignNot listedNot listedNot listedNot listed1 per tenantPer tenantNot listedUnlockSec. 117-7(5)(a)(2)
Ground SignNot listedNot listedNot listedNot listed1 per establishment or group of establishmentsMain street lot frontage of 60 linear feet or moreNot listedUnlockSec. 117-7(5)(a)(3)
Pedestrian SignNot listed6 square feetNot listedNot listed1 per tenantPer tenantNot listedUnlockSec. 117-7(5)(a)(4)
Rear Entrance Wall SignNot listed6 square feetNot listedNot listed1 per tenantPer tenantNot listedUnlockSec. 117-7(5)(a)(5)
Window Display SignNot listedNot listedNot listedNot listedNot listedPer tenantNot listedUnlockSec. 117-7(5)(a)(6)
Directional SignNot listed6 square feetNot listedNot listedNot listedNot listedNot listedUnlockSec. 117-7(5)(a)(7)
Temporary SignNot listed32 square feetNot listedNot listedNot listedMinimum 25 feet apartNot listedUnlockSec. 117-7(5)(a)(8)

PermitPal covers all 8 zoning districts in Fort Pierce. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Fort Pierce

  • Roof signs.
  • Portable or trailer signs.
  • A-frame or sandwich signs that do not comply with section 117-6(d)(1).
  • Signs attached to any tree, shrub or plant that have the potential to damage the tree, shrub or plant.
  • Signs located over or on any right-of-way except for approved projecting signs or temporary signs that have been properly permitted.
  • Signs attached to or placed upon any utility pole, streetlight, sidewalk, curb, fire hydrant, bridge or any other public property.
  • Vehicular signs except for those affixed to franchised buses, taxis, commercial vehicles or other vehicles during their normal course of business or lawfully parked.
  • Signs which copy or imitate official signs or which purport to have official status including signs utilizing fluorescent colors in the yellow and red spectrum typically associated with traffic control, safety notices and emergency response.
  • Signs which obstruct or interfere with any door, fire exit, stairway, ladder or opening intended to provide light, air, ingress or egress for any building.

Exempt Signs in Fort Pierce

  • Temporary signs, except special event signs.
  • Murals.
  • Window signs, including, but not limited to, credit card signs, decals or emblems.
  • Public convenience sign which identifies the location of restrooms, public telephones or the like.
  • Public utility sign which identifies the location of underground lines, high voltage areas or the like.
  • Public warning sign which indicates the dangers of trespassing, swimming, animals or the like.
  • Flag, emblem or insignia of the United States, the state or the city.
  • Seasonal display or decoration not advertising a product, service or establishment.

Sign Plan & Submission Notes for Fort Pierce

  • All plans and layouts for a sign or advertising structure shall be accompanied by an application which shall be filed with the building department in accordance with chapter 103 of this Code prior to the issuance of any permit.
  • Special event sign permit applications shall include type of signage proposed, responsible agents, and a processing fee.

Source: municode municipal code