Sign Regulations in Plantation, Florida

Plantation, Florida has specific sign regulations covering 35 sign types across 8 zoning districts. Regulated sign types include Directional, Warning or Information Sign, Wall Directory Sign, Shingle Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: November 21, 2025

Sign Regulation Overview for Plantation, Florida

Sample Sign Requirements in Plantation

Sign TypeMax HeightMax AreaSetback
Directional, Warning or Information Sign4 feet8 square feetAs per Sec. 22-20(n) and (q)
Wall Directory Sign16 square feet
Shingle Sign16 inches

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for PlantationFull Coverage

Sign Types Covered

35

  • Directional, Warning or Information Sign
  • Wall Directory Sign
  • Shingle Sign
  • Ground Sign - Single-Family Detached Dwelling (<50,000 sq ft or <75 ft from ROW)
  • +2 more types

Zoning Districts

8

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Plantation

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

Sign height limits in Plantation vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Plantation, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Plantation, regulated sign types include Directional, Warning or Information Sign, Wall Directory Sign, Shingle Sign, Ground Sign - Single-Family Detached Dwelling (<50,000 sq ft or <75 ft from ROW), and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Plantation vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Plantation are regulated with specific requirements for brightness, animation, and message duration. Plantation has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Plantation Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Plantation, Florida sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Plantation, Florida Sign Rules at a Glance

Plantation, Florida regulates 35 sign types across 8 zoning districts. Ground Sign - Single-Family Detached Dwelling (<50,000 sq ft or <75 ft from ROW)s in the Residential Districts (R) zoning district are capped at 5 feet tall and 1.5 square feet, with a 1 foot minimum; 1 ft per ft height over 7 ft setback (Sec. Sec. 22-43). Most commercial signs in Plantation require a permit.

Detailed Sign Ordinance Requirements for Plantation, Florida

Sign Rules by Zoning District in Plantation (8 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones316 inches16 square feet
Residential Districts (R)85 feet18 square feet
Commercial Business Districts (B, B-1P, B-2L, B-2P, B-3P, B-4P, B-5P, B-6P, B-AM, B-HCS, B-PO, B-HC, B-FCC, B-AC), Industrial Districts (I), Office Districts (O)16Not above roofline unless on embellishment per Sec. 22-20(h)Up to 200 square feet (varies: 60 sq ft for small frontage/single story; 100-200 sq ft for larger/multi-story)
Mixed-Use Districts (M)25 ft (0-2 lanes); 7 ft (3-5 lanes); 9 ft (6+ lanes)60 square feet per frontage
Community Facilities Districts (CF)3As per lanes Sec. 22-20(p); changeable copy on lower 1/2Up to 200 square feet
Utilities District (U)14 feet8 square feet
Parks and Open Space District (S)24 feet8 square feet
Planned Community Development Districts (PCD)25-9 feet per lanes or 5-7 ft for residential developmentsUp to 200 square feet

Zone-by-Zone Sign Requirements in Plantation(sample of 3 of 8 zones)

Residential Districts (R)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground Sign - Single-Family Detached Dwelling (<50,000 sq ft or <75 ft from ROW)5 feet1.5 square feet1 foot minimum; 1 ft per ft height over 7 ft1At frontageUnlockSec. 22-43
Wall Sign - Single-Family Detached Dwelling (<50,000 sq ft or <75 ft from ROW)3 square feet1Front wallUnlockSec. 22-43
Ground Sign - Single-Family Detached Dwelling (>50,000 sq ft or >75 ft from ROW)5 feet3 square feet1 foot minimum; 1 ft per ft height over 7 ft1Placed at frontageUnlockSec. 22-43
Wall Sign - Single-Family Detached Dwelling (>50,000 sq ft or >75 ft from ROW)3 square feet1Front wallUnlockSec. 22-43
Ground Sign - Dwelling Unit in Building with 2+ Units5 feet1.5 square feet1 foot minimum; 1 ft per ft height over 7 ft1FrontUnlockSec. 22-43
Wall Sign - Dwelling Unit in Building with 2+ Units3 square feet1Front wallUnlockSec. 22-43
Ground Sign - Single-Family Residential Development (50+ Units)5 feet (not associated with entry feature or privacy wall); 7 feet (associated with entry feature or privacy wall)18 square feet1 foot minimum; 1 ft per ft height over 7 ft1 double-facedAt development entranceUnlockSec. 22-43
Ground Sign - Multifamily Residential Development5 feet (not associated with entry feature or privacy wall); 7 feet (associated with entry feature or privacy wall)18 square feet1 foot minimum; 1 ft per ft height over 7 ft1 double-facedAt development entranceUnlockSec. 22-43

Commercial Business Districts (B, B-1P, B-2L, B-2P, B-3P, B-4P, B-5P, B-6P, B-AM, B-HCS, B-PO, B-HC, B-FCC, B-AC), Industrial Districts (I), Office Districts (O)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground Sign - Nonresidential Establishments5 ft (0-2 lanes); 7 ft (3-5 lanes); 9 ft (6+ lanes) per Sec. 22-20(p)Up to 64 square feet per face1 ft for <=7 ft height; 1 ft per ft height over 7 ft per Sec. 22-20(q)1 or 2 depending on frontage/type (e.g., 1 for single up to 500 ft; 2 for multiple frontages >500 ft or multi-story max 2)Fronting public right-of-way; one per vehicular entry for multi-story offices (max 2, 300 ft separation)UnlockSec. 22-30; Sec. 22-20
Wall Sign (Front) - Nonresidential EstablishmentsNot above roofline unless on embellishment per Sec. 22-20(h)Up to 200 square feet (varies: 60 sq ft for small frontage/single story; 100-200 sq ft for larger/multi-story)1 or 2 (e.g., 1 for most; 2 for multi-story >50k sq ft)Front wall fronting public right-of-wayUnlockSec. 22-30; Sec. 22-20
Freestanding Sign - Car Dealership Option20 feet (primary); 9 feet (second)50 square feet per face (primary); 32 square feet (optional second)1 ft min + 6 inches per ft height1 primary; optional 1 secondOn siteUnlockSec. 22-31
Ground Sign - Gasoline Service Station Option (2 Major Roadways)As per lanes Sec. 22-20(p)36 square feet per sign (up to 6 sq ft for services offered)General2Fronting major roadways (4+ lanes excl. turns)UnlockSec. 22-33
Ground Sign - Gasoline Service Station Option (1 Roadway)As per lanes40 square feet (up to 8 sq ft for services offered)General1Fronting roadwayUnlockSec. 22-33
Ground Sign - Regional Mall OptionAs per lanes64 square feet per face (Type C)General1 per qualifying frontagePer road frontage >70 ft ROW widthUnlockSec. 22-34
Ground Sign - Center Establishment OptionAs per lanesUp to 48 square feet per faceGeneral1 per qualifying sidePer side fronting >=70 ft ROW; in building site or common area near accessUnlockSec. 22-35
Menu Board Sign - Drive-Thru Restaurant Option7 feet32 square feetPer zoning districtUp to 2At drive-thruUnlockSec. 22-37

Community Facilities Districts (CF)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Ground Sign - Places of Worship or Educational InstitutionAs per lanes Sec. 22-20(p); changeable copy on lower 1/2Up to 64 square feet per faceGeneral1 per vehicular entry fronting ROW; max 2 with 300 ft separationFronting public right-of-wayUnlockSec. 22-36
Wall Sign (Front) - Places of Worship or Educational InstitutionNot above rooflineUp to 200 square feet1Front wall fronting ROWUnlockSec. 22-36
Ground Sign - Secondary Use (e.g., Parochial School with Worship)As per lanes16 square feetGeneral1On property with mixed usesUnlockSec. 22-36

PermitPal covers all 8 zoning districts in Plantation — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 8 zones for Plantation — start free

Prohibited Signs in Plantation

  • No off-premises permanent signs except for transit signs and traffic signs.
  • No roof or mansard permanent signs.
  • No permanent signs that emit any distracting sound as part of an advertising message.
  • No permanent signs with illumination that blinds or dazzles travelers, including blinking or flashing lights.
  • No super graphics on permanent signs.
  • No permanent signs painted directly on the surface of a building or on a flat affixed surface.
  • No pennants, banners, flags, whirlers, streamers, wheels, propellers, bunting, balloons, or other attention-attracting devices on permanent signs (except allowed flags).
  • No strip lighting outlining roofs or building parts on permanent signs.
  • No pole signs except for traffic signs per M.U.T.C.D. Standards.
  • No box cabinet signs except on ground signs for permanent signs.
  • No off-premises temporary signs.
  • No roof or mansard temporary signs.
  • No temporary signs that emit distracting sounds.
  • No temporary signs with blinding, dazzling, blinking, or flashing lights.
  • No super graphics on temporary signs.
  • No temporary signs painted directly on building surfaces.
  • No pennants, banners (except allowed transitory), flags (except allowed), whirlers, streamers, balloons, or similar devices on temporary signs.
  • No sandwich signs.
  • No snipe signs.
  • No portable or mobile signs except as allowed on operating vehicles under specific conditions.
  • No signs extending into, above, or anchored in public right-of-way except traffic and transit signs.
  • No signs obstructing ingress/egress, doors, windows, or fire escapes.
  • No signs in sight line setbacks or obstructing visibility at entrances and intersections.
  • No signs within utility easements without consent or in parking spaces/driveways.
  • No telephone numbers on permanent signs.
  • Adult entertainment signs limited to name and 'Adults Only'; no more than two exterior signs, one off-limits to minors.

Exempt Signs in Plantation

  • Traffic signs erected in accordance with M.U.T.C.D. Standards are exempt from permit requirements and certain dimensional, setback, and construction standards.
  • Transit signs are exempt from certain right-of-way and off-premises prohibitions.
  • Flags are allowed up to two for properties with ≤150 feet frontage or four for >150 feet, with height limits (≤50 feet nonresidential, ≤30 feet residential), flag size ≤30% pole height vertically and ≤50% horizontally; not mounted above roofline if on building.
  • Banners and flags are exempt from the definition of animated signs.
  • Noncommercial messages may be substituted on any allowed permanent or temporary sign without additional permit, occupying full or partial face; inherently on-premises.
  • Places of worship and public/private educational institutions exempt from permit fees for permanent signs.
  • Government traffic signs, warning, information, or directional signs in public rights-of-way or on public property are allowed without general sign restrictions.
  • Roadside memorials installed by city personnel in specified locations and formats are allowed as traffic signs.
  • Window neon signs up to 10% of glazed area (non-flashing) and other window signage up to 20% cumulative, for business-zoned properties.

Sign Plan & Submission Notes for Plantation

  • Properties with more than one permanent sign must submit a sign package ensuring uniform sign attributes (style, materials, colors, fonts, etc.) for all permanent signs on the property; future signs conform to first approved if no package submitted.
  • Sign permit applications require an inventory of all existing signs on the property, including size, color, location, text details (previous inventory allowable if updated within 30 days).
  • Sign special exceptions (variance-like) required if permanent sign permit denied for noncompliance; application to city governing body within 30 business days of denial, with site-specific justification; not available for off-premises or temporary signs except post-emergency.
  • Administrative adjustments (limited special exceptions) may be approved by director of planning, zoning, and economic development pursuant to section 27-52.
  • For center establishments, regional malls, and similar multi-occupant developments, elective provisions may require unified signage plans under common control documents, with principal/secondary message allocations.
  • Golf courses and primary residential corridor signs require compliance with specific design packages on file with city clerk, treated as master plans; permit required, other ground signs removed.

Source: municode municipal code