Sign Regulations in Weston, Florida

Weston, Florida has specific sign regulations covering 35 sign types across 6 zoning districts. Regulated sign types include Temporary Real Estate Sale/Leasing Sign, Temporary Noncommercial Sign, Monument Sign (Multi-Family Complex). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 20, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Weston, Florida

Sample Sign Requirements in Weston

Sign TypeMax HeightMax AreaSetback
Monument Sign (Multi-Family Complex)6 ft32 sq ftNot listed
Building Mounted Sign (Multi-Family Complex)Not listed16 sq ftNot listed
Monument Sign (Subdivisions, Planned Developments)6 ft32 sq ftNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for WestonFull Coverage

Sign Types Covered

35

  • Temporary Real Estate Sale/Leasing Sign
  • Temporary Noncommercial Sign
  • Monument Sign (Multi-Family Complex)
  • Building Mounted Sign (Multi-Family Complex)
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Frequently Asked Questions

In Weston, the height limit for Monument Sign (Multi-Family Complex) in the Residential District (Single-Family, Townhomes, Multi-Family, MF1, MF2, MF3) is 6 ft (Sec. 126.11(A)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Weston require a permit. From the submission notes on this page: In retail shopping centers, one-story office-industrial with exterior access: must comply with any approved uniform sign plan. If there is no uniform sign plan or the plan does not address criteria, default regulations apply. Run a code check for an exact address to see the permit requirements for that zone.

Weston's sign code covers 35 sign types, including Temporary Real Estate Sale/Leasing Sign, Temporary Noncommercial Sign, Monument Sign (Multi-Family Complex), and Building Mounted Sign (Multi-Family Complex). Most commercial signs need a permit. The ordinance lists 5 exemptions. One of them: Flags, whether displayed on poles or in another fashion, do not require a sign permit. Permanent flagpole installation requires a building permit; on non-residential properties, the flagpole/device must be shown on the site plan. The full list is on this page.

In Weston, Monument Sign (Office, Industrial, Institutional) in the Nonresidential District, Office, Industrial, Institutional, C-1, O-1, IOC, PECD must be set back at least 10 ft from right-of-way (Sec. 126.11(B)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Weston's sign ordinance that cover digital, changing, or flashing signs: Signs containing a visible light source, containing exposed neon or LED, with an internally illuminated cabinet, or channel lettering/logos with internally illuminated face are prohibited. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Weston Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Weston, Florida, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Weston, Florida Sign Rules at a Glance

Weston, Florida regulates 35 sign types across 6 zoning districts. Monument Signs (Office, Industrial, Institutional) in the Nonresidential District, Office, Industrial, Institutional, C-1, O-1, IOC, PECD are capped at 6 ft tall and 36 sq ft, set back at least 10 ft from right-of-way (Sec. 126.11(B)). Most commercial signs in Weston require a permit.

Detailed Sign Ordinance Requirements for Weston, Florida

Sign Rules by Zoning District in Weston (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential District (Single-Family, Townhomes, Multi-Family, MF1, MF2, MF3)11Flagpole max 25 ft32 sq ftNot listed
Nonresidential District, Office, Industrial, Institutional, C-1, O-1, IOC, PECD11Max 70 ft or less if required by zoningUp to 216 sq ft depending on pole height (refer to § 126.12(B)(1) for scale); hoist side of flag max 20% of pole heightNot listed
Freestanding Commercial4Letters not to exceed 36 in40 sq ftNot listed
Retail Shopping Center, One Story Office-Industrial with Exterior Access418 in36 sq ftNot listed
Mixed Use (Retail and Office Combined)46 ft; letters not to exceed 12 in in height80 sq ftNot listed
General Regulations For All Zones325 ft (residential); 70 ft (nonresidential or as limited by zoning)Varies by flagpole height: up to 216 sq ft (pole max 70 ft nonresidential)Not listed

Zone-by-Zone Sign Requirements in Weston(sample of 3 of 6 zones)

Residential District (Single-Family, Townhomes, Multi-Family, MF1, MF2, MF3)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Monument Sign (Multi-Family Complex)6 ft32 sq ftNot listedNot listedTwo per street frontageTwo per street frontageNot listedUnlock§ 126.11(A)
Building Mounted Sign (Multi-Family Complex)Not listed16 sq ftNot listedNot listedTwo per street frontageTwo per street frontageNot listedUnlock§ 126.11(A)
Monument Sign (Subdivisions, Planned Developments)6 ft32 sq ftNot listedNot listedTwo per street frontageTwo per street frontageNot listedUnlock§ 126.11(A)
Temporary Real Estate Sale/Leasing Sign5 ft above grade2 sq ft per parcelNot listedNot listedNot listedYard/Parcel (not in right-of-way)Not listedUnlock§ 126.18(A)
Temporary Noncommercial Sign5 ft above grade4 sq ftNot listedNot listedNot listedNot listedNot listedUnlock§ 126.18(B)
Noncommercial HOA Gatehouse SignNot listed16 sq ftNot listedNot listed1 per gatehouseAffixed to the HOA gatehouseNot listedUnlock§ 126.11(F)(3)
Building Entrance SignNot listed6 sq ftNot listedNot listed1 per buildingWithin 5 ft of main entranceNot listedUnlock§ 126.11(G)
Flag Signs (Residential)Flagpole max 25 ftUp to 24 sq ft if pole height up to 25 ft; see § 126.12(B)(1) for additional scalingNot listedFlagpole must be set back at least height of pole from all property boundariesNot listedMax 3 poles per property, max 2 flags per poleNot listedUnlock§ 126.12

Nonresidential District, Office, Industrial, Institutional, C-1, O-1, IOC, PECD

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Office, Industrial, Institutional)Letters not to exceed 60 in80 sq ftNot listedNot listed1 per wall face, or 2 for walls > 80 ft (max 6 per building)1 per wall face, or 2 for walls > 80 ft in length (max 6 per building)Not listedUnlock§ 126.11(B)
Monument Sign (Office, Industrial, Institutional)6 ft36 sq ftNot listedAt least 10 ft from right-of-way (§ 126.20)11 per parcelNot listedUnlock§ 126.11(B)
Directory Sign (Office, Industrial, Institutional)3 ft18 sq ftNot listedNot listed1 per building1 per buildingNot listedUnlock§ 126.11(B)
Directional Sign (Office, Industrial, Institutional)3 ft6 sq ftNot listedNot listed1 per vehicular access point1 per vehicular access pointNot listedUnlock§ 126.11(B), § 126.20(E)
Temporary Real Estate Sale/Leasing Sign6 ft above grade2 sq ft per parcelNot listedNot listedNot listedNot listedNot listedUnlock§ 126.18(A)
Permanent Real Estate Leasing Sign (Monument Type)Not listed2 sq ftNot listedNot listed1 per monument signOn monument sign onlyNot listedUnlock§ 126.11(D)
Flag Signs (Nonresidential)Max 70 ft or less if required by zoningUp to 216 sq ft depending on pole height (refer to § 126.12(B)(1) for scale); hoist side of flag max 20% of pole heightNot listedFlagpole setback equal to pole heightNot listedMax 3 poles per property, 2 flags per pole; must not be on top of buildingsNot listedUnlock§ 126.12
Parking Lot Space SignNot listed12 in wide by 18 in tall12 in2 ft from back of curb or wheel stopNot listedOn single post, 2 ft from back of curb/wheel stop, 7 ft vertical clearanceNot listedUnlock§ 126.20(H)

Freestanding Commercial

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Freestanding Commercial)Letters not to exceed 36 in40 sq ftNot listedNot listed11 signNot listedUnlock§ 126.11(B)
Monument Sign (Freestanding Commercial)6 ft36 sq ftNot listedNot listed1 per parcel (or 1 per street frontage if over 1.5 acres)1 per parcel (or 1 per street frontage if parcel over 1.5 acres)Not listedUnlock§ 126.11(B)
Directory Sign (Freestanding Commercial)3 ft18 sq ftNot listedNot listed1 per building1 per buildingNot listedUnlock§ 126.11(B)
Directional Sign (Freestanding Commercial)3 ft6 sq ftNot listedNot listed1 per vehicular access point1 per vehicular access pointNot listedUnlock§ 126.11(B)

PermitPal covers all 6 zoning districts in Weston. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Weston

  • No signs shall be permitted on a plot or parcel either as a main or accessory use except in accordance with the provisions of this Chapter.
  • Signs are prohibited on public or private rights-of-way, except noncommercial signs erected by or on behalf of a governmental entity or public utility.
  • Signs are prohibited on public property or a public place, except those placed by or at the direction of the City, or as required by this Chapter.
  • No signs may obstruct any window, door, fire escape, stairway, or opening intended to provide light, air, ingress, or egress for any building in a manner that would violate the Building Code.
  • No sign shall be erected, constructed or maintained so as to obstruct any fire escape, required exit, window, or door opening used as a means of egress.
  • No sign shall be attached in any form, shape or manner that will interfere with any opening required for ventilation.
  • Signs that obstruct the view of another sign or traffic control device are prohibited.
  • Roof signs and signs that extend above the parapet or roof of a building are prohibited.
  • Signs on benches and freestanding shelters are prohibited.
  • Vehicle signs viewable from a public right-of-way that remain stationary for more than 24 hours (excluding weekends and holidays) are prohibited.
  • Signs towed behind a vehicle are prohibited.
  • Signs located on a fence are prohibited.
  • Pole signs, fixed projecting signs, projected signs, snipe signs, painted signs, banner signs (except as specifically permitted), animated signs, portable/unattached signs, inflatable signs, signs emitting sound or odor or visible matter, signs that may be confused with traffic control devices, and abandoned or dilapidated signs are prohibited.
  • Signs containing a visible light source, containing exposed neon or LED, with an internally illuminated cabinet, or channel lettering/logos with internally illuminated face are prohibited.
  • Externally illuminated signs where lighting is not recessed in the ground are prohibited.
  • Signs with changeable content (other than may be required by other law or regulation) are prohibited.
  • Off-premises signs are prohibited, except for those lawfully erected prior to January 1, 2001.
  • Signs that do not comply with the provisions of this Chapter are prohibited.
  • Freestanding temporary nonresidential and monument signs must be placed at least ten feet from the right-of-way and are not allowed within sight triangles or within ten feet of adjacent property lines.
  • Signs shall not project beyond the corner of a building or more than eight inches out from a building wall.
  • Advertising signs are not permitted on telecommunications towers.
  • No sign shall be constructed of any light-reflective letters or materials.
  • No backlighting of awning or canopy signs is allowed.
  • Signs that are illuminated shall utilize the most energy efficient means available.

Exempt Signs in Weston

  • Signs or sign structures erected or required to be erected by a governmental agency are exempt from the permitting requirement.
  • Temporary signs are exempt from the permitting requirement (but are still subject to code and placement restrictions).
  • Changing the content on a bulletin board, poster board, display encasement, marquee, or other permanent sign designed for content change, without altering the sign structure, is exempt from permitting.
  • Flags, whether displayed on poles or in another fashion, do not require a sign permit. Permanent flagpole installation requires a building permit; on non-residential properties, the flagpole/device must be shown on the site plan.
  • If an exemption allows a sign with commercial content, a sign of identical physical characteristics displaying noncommercial content is also exempt from permitting.

Sign Plan & Submission Notes for Weston

  • A uniform sign plan is required for all signs in multi-tenant projects (§126.11(C)). All building-mounted signs in such projects must be uniform in terms of illumination, material, fabrication, and sign area, use not more than one font style (other than registered trademarks), and be limited to no more than one color consistent with architectural standards.
  • If a sign conforms to the uniform sign plan but conflicts with code provisions (§126.11(B)), it is considered nonconforming and must be brought into compliance if 50% or more of the signs in the project are replaced (§126.11(C)(4), §126.24(A)(2)).
  • In retail shopping centers, one-story office-industrial with exterior access: must comply with any approved uniform sign plan. If there is no uniform sign plan or the plan does not address criteria, default regulations apply.
  • Hanging signs are only permitted if allowed under the approved uniform sign plan (§126.17(A)).
  • Architectural embellishments that act as signs require approval and must be consistent with the design in the site plan. Changes require a site plan amendment.
  • Where signs conform to a City approval but fail to conform to this Chapter, they are considered nonconforming and regulated accordingly (§126.11(H), §126.24).