Sign Regulations in Auburn, Georgia
Auburn, Georgia has specific sign regulations covering 23 sign types across 7 zoning districts. Regulated sign types include For Sale/For Lease Sign, Subdivision Sign, Directory Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 7, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Auburn, Georgia
Sample Sign Requirements in Auburn
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| For Sale/For Lease Sign | Not listed | Not listed | Out of right-of-way or at least 10 ft from back of curb/edge of pavement; 15 ft at corner lots (see general setback regulations) |
| Subdivision Sign | 6 ft. | 32 sq. ft. | 10 ft. |
| Directory Sign | Free standing: 5 ft.; Wall sign: not higher than wall | Free standing sign: 4 sq. ft.; Wall sign: 16 sq. ft. | Free standing: 3 ft. |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
23
- For Sale/For Lease Sign
- Subdivision Sign
- Directory Sign
- Awning Sign
- +2 more types
Zoning Districts
7
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Auburn
Other Cities in Georgia
Frequently Asked Questions
In Auburn, the height limit for Directory Sign (for buildings in planned commercial/retail, office, industrial) in the O-I, C-1, C-2, C-3, M-1, M-2, PUD (nonresidential) zoning districts is 8 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Auburn require a permit. From the submission notes on this page: A fully dimensioned site plan showing lot frontage, building frontage, parking areas, and location of all existing and proposed signs is required for sign permit applications (except for temporary signs). Run a code check for an exact address to see the permit requirements for that zone.
Auburn's sign code covers 23 sign types, including For Sale/For Lease Sign, Subdivision Sign, Directory Sign, and Awning Sign. Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: All permanent signs in place outside road right-of-way as of January 16, 2003 are exempt (unless otherwise prohibited), provided they meet height and setback requirements and do not require a permit. The full list is on this page.
In Auburn, Subdivision Sign in the R-MD, MH, RM-8, AG, R-100, R-100CZP, PUD Residential zoning districts must be set back 10 ft. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Auburn's sign ordinance that cover digital, changing, or flashing signs: Flashing signs are prohibited in all zoning districts. Animation on all temporary signs is prohibited. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Auburn Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Auburn, Georgia, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Auburn, Georgia Sign Rules at a Glance
Auburn, Georgia regulates 23 sign types across 7 zoning districts. Banners in the O-I, C-1, C-2, C-3, M-1, M-2, PUD (nonresidential) zoning districts are capped at 5 ft tall, 32 sq ft per face, and 10 ft wide, with a 10 ft setback. Most commercial signs in Auburn require a permit.
Detailed Sign Ordinance Requirements for Auburn, Georgia
Sign Rules by Zoning District in Auburn (7 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| R-MD, MH, RM-8, AG, R-100, R-100CZP, PUD Residential | 3 | 6 ft. | 32 sq. ft. | Not listed |
| R-1, R-2 | 3 | 6 ft. | 32 sq. ft. | Not listed |
| O-I, C-1, C-2, C-3, M-1, M-2, PUD (nonresidential) | 18 | 30 ft. overall, 12 ft. face height, 25 ft. face length | 600 sq. ft. | Not listed |
| Commercial zoning districts | 1 | Not listed | Not listed | Not listed |
| Office zoning districts | 1 | Not listed | Not listed | Not listed |
| Industrial zoning districts | 1 | Not listed | Not listed | Not listed |
| General Regulations For All Zones | 2 | 30 ft. | 300 sq. ft. | Not listed |
Zone-by-Zone Sign Requirements in Auburn(sample of 3 of 7 zones)
R-MD, MH, RM-8, AG, R-100, R-100CZP, PUD Residential
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| For Sale/For Lease Sign | Not listed | Not listed | Not listed | Out of right-of-way or at least 10 ft from back of curb/edge of pavement; 15 ft at corner lots (see general setback regulations) | Not listed | On property where premises is for sale or lease; must comply with general setback requirements. | Not listed | Unlock | 17.120.040(A) and 17.120.050 |
| Subdivision Sign | 6 ft. | 32 sq. ft. | Not listed | 10 ft. | Two per entrance | Per entrance to subdivision | Not listed | Unlock | 17.120.040(A) and 17.120.060 Table Row 9 |
| Directory Sign | Free standing: 5 ft.; Wall sign: not higher than wall | Free standing sign: 4 sq. ft.; Wall sign: 16 sq. ft. | Not listed | Free standing: 3 ft. | One per road frontage | On premises | Not listed | Unlock | 17.120.040(A) and 17.120.060 Table Row 8 |
R-1, R-2
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| For Sale/For Lease Sign | Not listed | Not listed | Not listed | Out of right-of-way or at least 10 ft from back of curb/edge of pavement; 15 ft at corner lots (see general setback regulations) | Not listed | On property where premises is for sale or lease; must comply with general setback requirements. | Not listed | Unlock | 17.120.040(B) |
| Subdivision Sign | 6 ft. | 32 sq. ft. | Not listed | 10 ft. | Two per entrance | Per entrance to subdivision | Not listed | Unlock | 17.120.040(B) and 17.120.060 Table Row 9 |
| Directory Sign | Free standing: 5 ft.; Wall sign: not higher than wall | Free standing sign: 4 sq. ft.; Wall sign: 16 sq. ft. | Not listed | Free standing: 3 ft. | One per road frontage | On premises | Not listed | Unlock | 17.120.040(B) and 17.120.060 Table Row 8 |
O-I, C-1, C-2, C-3, M-1, M-2, PUD (nonresidential)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Subdivision Sign | 6 ft. | 32 sq. ft. | Not listed | 10 ft. | Two per entrance | Per entrance to subdivision | Not listed | Unlock | 17.120.040(B) and 17.120.060 Table Row 9 |
| Directory Sign | Free standing: 5 ft.; Wall sign: not higher than wall | Free standing sign: 4 sq. ft.; Wall sign: 16 sq. ft. | Not listed | Free standing: 3 ft. | One per road frontage | On premises | Not listed | Unlock | 17.120.040(B) and 17.120.060 Table Row 8 |
| Banner | 5 ft. | 32 sq. ft. per face | 10 ft. | 10 ft. | One per public walk-in entrance | Must be set back at least 10 ft. from property line/right-of-way; not in parking spaces required for premises. | Not listed | Unlock | 17.120.040(B) and 17.120.070(A) |
| Temporary Sign | 5 ft. | 32 sq. ft. per face | 10 ft. | 10 ft. | One per public walk-in entrance | At least 10 ft. from property line/right-of-way; not in parking spaces required for premises. | Not listed | Unlock | 17.120.040(B), 17.120.070(A) |
| Freestanding Sign (individual use/lot or planned center) | 5, 10, 15, or 20 ft. | 150 sq. ft. | Not listed | 5, 10, or 20 ft. depending on sign height | One per road frontage; no more than two per frontage | On premises, meets setback requirements | Not listed | Unlock | 17.120.060 Table Row A1a |
| Monument Sign (individual use/lot or planned center) | 5, 10, 15, or 20 ft. | 200 sq. ft. | Not listed | 5, 10, or 20 ft. depending on sign height | One per road frontage; no more than two per frontage | On premises, meets setback requirements | Not listed | Unlock | 17.120.060 Table Row A1b |
| Freestanding/Monument Sign (lot without road frontage) | 5, 10, 15, or 20 ft. | Freestanding 150 sq. ft., Monument 200 sq. ft. | Not listed | 5-10 ft., 10-20 ft., or 20+ ft. depending on sign height | 1 sign allowed | Lot without road frontage | Not listed | Unlock | 17.120.060 Table Row A1c |
| Directory Sign (for buildings in planned commercial/retail, office, industrial) | 8 ft. | 100 sq. ft.; 10 sq. ft. for park name. | Not listed | 10 ft.; 100 ft. from entrance | One per entrance | At entrance, at least 100 ft from entrance | Not listed | Unlock | 17.120.060 Table Row 6 |
PermitPal covers all 7 zoning districts in Auburn. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Auburn
- Flashing signs are prohibited in all zoning districts.
- Portable signs are prohibited in all zoning districts except as allowed in Section 17.120.070.
- Roof signs are prohibited in all zoning districts.
- Signs attached to any street sign or marker, traffic control sign or device, or attached to or painted on any utility pole, post, tree, rock, shrub, plant, or other natural object or feature are prohibited.
- Motor vehicle signs as defined are prohibited.
- Signs on public right-of-way are prohibited.
- Temporary signs are prohibited except as allowed in Section 17.120.070.
- Affixing signs in any manner to trees, street or utility poles, or other signs and sign structures is prohibited.
- Abandoned signs are prohibited.
- Dangerous or defective signs are prohibited.
- Placement of temporary signs in required parking spaces or public right-of-way is prohibited.
- Animation on all temporary signs is prohibited.
Exempt Signs in Auburn
- All permanent signs in place outside road right-of-way as of January 16, 2003 are exempt (unless otherwise prohibited), provided they meet height and setback requirements and do not require a permit.
- Construction signs with a maximum area not to exceed thirty-two square feet are exempt (unless otherwise prohibited), provided they meet height and setback requirements and do not require a permit.
- Directory signs are exempt (unless otherwise prohibited), provided they meet height and setback requirements and do not require a permit.
- Window signs and door signs are exempt (unless otherwise prohibited), provided they meet height and setback requirements and do not require a permit.
- Signs not visible from public thoroughfares are exempt (unless otherwise prohibited), provided they meet height and setback requirements and do not require a permit.
- Signs within a business, office, mall or totally enclosed area are exempt (unless otherwise prohibited), provided they meet height and setback requirements and do not require a permit.
- Flags or pennants are exempt (unless otherwise prohibited), provided they meet height and setback requirements and do not require a permit.
Sign Plan & Submission Notes for Auburn
- A fully dimensioned site plan showing lot frontage, building frontage, parking areas, and location of all existing and proposed signs is required for sign permit applications (except for temporary signs).
- For ground signs, the sign plan must show the distance from the right-of-way and edge of pavement, and street corner visibility calculations.
- A summary table listing location, type, and area of any existing and proposed signs must be provided with the application (except for temporary signs).
- A fully dimensioned elevation drawing of any proposed sign, showing sign type, height, and copy area, must be submitted.
- For facade signs, an elevation of the building showing sign placement must be provided.
- A site plan is specifically required to show designated driveway access point for billboards.
- Variance or zoning board approval is required for some sign types or locations (e.g., free standing/monument sign for a lot without road frontage).
Source: municode municipal code