Sign Regulations in Conyers, Georgia
Conyers, Georgia has specific sign regulations covering 41 sign types across 3 zoning districts. Regulated sign types include All Sign Types - General Standard, Temporary Sign - Air or Gas Filled Device / Balloon, Temporary Sign - Banner. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: December 6, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Conyers, Georgia
Sample Sign Requirements in Conyers
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Temporary Sign - Air or Gas Filled Device / Balloon | 20 ft. | 150 sq. ft. of area per device. | Setback from roadways and sidewalks equal to device height plus 10 ft. |
| Temporary Sign - Banner | Not listed | 32 sq. ft. per banner; aggregate up to 32 sq ft per nonresidential use at one main entrance. | Not listed |
| Temporary Sign - Balloon and Streamer / Pennant (general) | Not listed | Not listed | Setback from any roadway or pedestrian walkway equal to device height plus 10 ft. |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
41
- All Sign Types - General Standard
- Temporary Sign - Air or Gas Filled Device / Balloon
- Temporary Sign - Banner
- Temporary Sign - Balloon and Streamer / Pennant (general)
- +2 more types
Zoning Districts
3
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Conyers
Other Cities in Georgia
Frequently Asked Questions
In Conyers, the height limit for Primary Ground Sign - Interstate-Oriented (Nonresidential Lot) in the Nonresidential zoning district and other zoning districts is 80 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Conyers require a permit. From the submission notes on this page: All permanent ground and wall signs generally require a sign permit; applications must include site plans and building elevations as specified in Sec. 8-5-7. There is no separate master sign plan or coordinated sign plan requirement stated in the provided text. Run a code check for an exact address to see the permit requirements for that zone.
Conyers's sign code covers 41 sign types, including All Sign Types - General Standard, Temporary Sign - Air or Gas Filled Device / Balloon, Temporary Sign - Banner, and Temporary Sign - Balloon and Streamer / Pennant (general). Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Display of address numerals not exceeding six inches in height for single‑family residential uses or 12 inches in height for all other uses is exempt from the sign permit requirement, provided all other standards are met (Sec. 8-5-16(1)). The full list is on this page.
In Conyers, Standard Informational Sign (Residential Use) in the Residential zoning district and other zoning districts must be set back at least 5 ft from public right-of-way. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Conyers's sign ordinance that cover digital, changing, or flashing signs: Animated signs are prohibited except where specifically permitted in a particular zoning district (Sec. 8-5-13(3)). Except as permitted in Sec. 8-5-22, no sign may have blinking, flashing, or fluctuating lights or other devices with changing light intensity, brightness, or color, and no sign may be animated or simulate movement (Sec. 8-5-18(b)). Subject to Sec. 8-5-22, no sign may contain an electronic or computerized message changer unless specifically allowed as a commercial electronic variable message sign (Sec. 8-5-18(c), Sec. 8-5-22). Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Conyers Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Conyers, Georgia, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Conyers, Georgia Sign Rules at a Glance
Conyers, Georgia regulates 41 sign types across 3 zoning districts. Temporary Signs - Air or Gas Filled Device / Balloon are capped at 20 ft tall. Most commercial signs in Conyers require a permit.
Detailed Sign Ordinance Requirements for Conyers, Georgia
Sign Rules by Zoning District in Conyers (3 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 15 | Nonresidential districts: up to allowed structure/building height for district or 60 ft, whichever is less. Residential districts: up to 25 ft or height of primary structure, whichever is less. | Per face: max 672 sq ft, max 14 ft height x 48 ft length; up to 2 faces, cumulative max 1,344 sq ft. | Not listed |
| Residential zoning district; Residential-Agriculture District (R-A); Residential Single-Family District (RS-20); Residential Single-Family District (RS-14); Traditional Neighborhood Development District (TND); Townhouse Residential District (TH); Residential Manufactured Housing District (RMH); Residential Multifamily District (RM); residential district; residentially zoned parcel | 12 | 6 ft. | Aggregate total of entrance signs per entrance: 64 sq ft. | Not listed |
| Nonresidential zoning district; nonresidential districts; Office-Institutional District (O-I); Neighborhood Business District (BN); Mixed Use Development District (MxD); General Business District (BG); Downtown District (D); Highway Service Business District (HSB); Industrial/Distribution District (I-D); Gateway Village District (GV); nonresidential use | 14 | 80 ft. | Max 672 sq ft per sign face (derived from 2 sq ft per linear ft formula and explicit maximum). | Not listed |
Zone-by-Zone Sign Requirements in Conyers
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Temporary Sign - Air or Gas Filled Device / Balloon | 20 ft. | 150 sq. ft. of area per device. | Not listed | Setback from roadways and sidewalks equal to device height plus 10 ft. | Maximum one device per lot at a time. | On a lot, set back from all roadways and sidewalks at least the height of the device plus 10 ft. | Not listed | Unlock | Sec. 8-5-14(1)(a)-(c); Sec. 8-5-14(4). |
| Temporary Sign - Banner | Not listed | 32 sq. ft. per banner; aggregate up to 32 sq ft per nonresidential use at one main entrance. | Not listed | Not listed | Each nonresidential use is permitted one banner sign at one main entrance. | Individually attached to a building façade at a main entrance; may not extend above the façade or roofline; may not be attached to light poles, freestanding poles, fences, utility poles, or similar structures. | Not listed | Unlock | Sec. 8-5-14(2)(a)-(d). |
| Flag | Nonresidential districts: up to allowed structure/building height for district or 60 ft, whichever is less. Residential districts: up to 25 ft or height of primary structure, whichever is less. | Maximum total flag area per pole based on pole height: up to 25 ft pole = 30 sq ft; 26–50 ft pole = 60 sq ft; 51–60 ft pole = 100 sq ft. Also, hoist side may not exceed 20% of pole height. | Not listed | Vertical flagpole must be set back from all property boundaries at least its height. | Up to 3 flagpoles per lot; up to 2 flags per flagpole. | On purpose-built, professionally fabricated vertical or mast-arm flagpoles located on the lot; vertical flagpole must be set back from all property boundaries at least a distance equal to the height of the flagpole. | Not listed | Unlock | Sec. 8-5-15(a)-(g). |
| Standard Informational Sign (Residential Lot) | No greater than 4 ft above adjacent street grade or 3 ft above ground level, whichever is greater. | 6 sq. ft. per sign; aggregate sign area per lot not to exceed 18 sq. ft. | Not listed | At least 5 ft from public right-of-way; not within right-of-way. | Number limited by aggregate area (18 sq ft). | On residential lots, outside public right-of-way and at least 5 ft from right-of-way; may not be attached to light poles, freestanding poles, utility poles, bollards, or similar structures. | Not listed | Unlock | Definition of Standard informational sign, Sec. 8-5-4; Sec. 8-5-16(6). |
| Standard Informational Sign (Nonresidential Parcel - Window) | Not listed | 6 sq. ft. per sign; aggregate per lot 18 sq. ft. | Not listed | Not listed | Limited by aggregate 18 sq ft per lot. | Placed within the window of a building in nonresidential districts; may not be attached to poles or similar structures. | Not listed | Unlock | Definition of Standard informational sign, Sec. 8-5-4; Sec. 8-5-16(6). |
| Window Sign (General) | Not listed | No more than 30% of the available window area per building elevation. | Not listed | Not listed | Limited by 30% of window area. | Installed flush with interior or exterior of window and intended to be viewed from outside. | Not listed | Unlock | Definition of Window sign, Sec. 8-5-4; Sec. 8-5-13(8); Sec. 8-5-16(3); Sign table item 10, Sec. 8-5-19A. |
| Interior Project Directional Sign (Nonresidential Developments) | 4 ft. maximum sign height. | 4 sq. ft. maximum sign area per sign. | Not listed | Setback from right-of-way may be 0 ft; must not block visibility and may not be within 100 ft of project entrance. | Maximum 2 signs per internal intersection. | Within developments or planned subdivisions of land in nonresidential zoning districts, at internal intersections of private driveways or public streets; may not be located within 100 ft of a project entrance. | Not listed | Unlock | Sec. 8-5-21(1)-(7). |
| Oversized Sign (Ground, Interstate-Oriented) | Max 48 ft above ground level to top of sign, including structure. | Per face: max 672 sq ft, max 14 ft height x 48 ft length; up to 2 faces, cumulative max 1,344 sq ft. | Max 48 ft per face length; max 14 ft face height. | Must be in buildable area; subject to minimum separation distances (500–5,000 ft) rather than traditional setbacks. | Effectively limited to spacing rules; no more than one per 500 linear ft on same side of street. | Only on properties adjacent to interstate highways, within nonresidential zoning districts; only in buildable area of lot; must be independent of any building or other structure (except its own structure). | Not listed | Unlock | Sec. 8-5-20(1)-(8). |
Residential zoning district; Residential-Agriculture District (R-A); Residential Single-Family District (RS-20); Residential Single-Family District (RS-14); Traditional Neighborhood Development District (TND); Townhouse Residential District (TH); Residential Manufactured Housing District (RMH); Residential Multifamily District (RM); residential district; residentially zoned parcel
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Primary Ground Sign - Individual Residential Lot (0–3 acres) | 6 ft. | Ground sign: 18 sq ft max sign size for lots 0–3 acres. | Not listed | Off right-of-way; no sign closer than 5 ft from public right-of-way and no portion may violate 5-ft setback. | One ground sign structure per road frontage not to exceed maximum allowable square footage. | On an individual residential lot, off the public right-of-way; at least 5 ft back from right-of-way. | Not listed | Unlock | Sec. 8-5-19A, item 3 (Primary signs for an individual building on an individual residential lot) – Ground signs table; footnote 1. |
| Primary Ground Sign - Individual Residential Lot (3–5 acres) | 6 ft. | Ground sign: 24 sq ft max sign size for lots 3–5 acres. | Not listed | Off right-of-way; minimum 5 ft from public right-of-way. | One ground sign structure per road frontage. | On an individual residential lot of 3–5 acres, off right-of-way. | Not listed | Unlock | Sec. 8-5-19A, item 3 – Ground signs table, 3–5 acres row. |
| Primary Ground Sign - Individual Residential Lot (5 acres or greater) | 6 ft. | Ground sign: 32 sq ft max sign size for lots 5 acres or greater. | Not listed | Off right-of-way; at least 5 ft from right-of-way. | One ground sign structure per road frontage. | On an individual residential lot of 5+ acres, off right-of-way. | Not listed | Unlock | Sec. 8-5-19A, item 3 – Ground signs table, 5 or greater row. |
| Accessory Ground Sign - Individual Residential Lot (0–3 acres) | 3 ft. | 2 sq ft max sign size per accessory ground sign for lots 0–3 acres. | Not listed | Off right-of-way; at least 5 ft from right-of-way (per general footnote 1). | Two sign structures per entrance. | On an individual residential lot, off right-of-way at entrances. | Not listed | Unlock | Definition of Accessory ground sign, Sec. 8-5-4; Sec. 8-5-19A, item 7 – Ground signs, 0–3 acres row. |
| Accessory Ground Sign - Individual Residential Lot (3–5 acres) | 3 ft. | 3 sq ft max sign size per sign for lots 3–5 acres. | Not listed | Off right-of-way; minimum 5 ft from public right-of-way. | Two sign structures per entrance. | On individual residential lot of 3–5 acres at entrances. | Not listed | Unlock | Sec. 8-5-19A, item 7 – Ground signs, 3–5 acres row. |
| Accessory Ground Sign - Individual Residential Lot (5 acres or greater) | 3 ft. | 4 sq ft max sign size per sign for lots 5 or greater acres. | Not listed | Off right-of-way; minimum 5 ft from public right-of-way. | Two sign structures per entrance. | On individual residential lot of 5+ acres at entrances. | Not listed | Unlock | Sec. 8-5-19A, item 7 – Ground signs, 5 or greater row. |
| Permanent Entrance Sign - Residential Subdivision / Multifamily Complex | 6 ft. | Aggregate total of entrance signs per entrance: 64 sq ft. | Not listed | Off public right-of-way; at least 5 ft from right-of-way per footnote 1. | Maximum two sign structures per subdivision or multifamily complex per entrance. | At the public street or private driveway entrance to a residential development, residential subdivision development, or multifamily complex, off the right-of-way. | Not listed | Unlock | Definition of Entrance sign, Sec. 8-5-4; Sec. 8-5-19A, item 4. |
| Standard Informational Sign (Residential Use) | 4 ft above adjacent street grade or 3 ft above ground level, whichever is greater. | 6 sq ft per sign; aggregate 18 sq ft per lot. | Not listed | At least 5 ft from public right-of-way. | Limited by 18 sq ft aggregate. | On residential lots, at least 5 ft from public right-of-way and not in right-of-way. | Not listed | Unlock | Definition of Standard informational sign, Sec. 8-5-4; Sec. 8-5-16(6). |
Nonresidential zoning district; nonresidential districts; Office-Institutional District (O-I); Neighborhood Business District (BN); Mixed Use Development District (MxD); General Business District (BG); Downtown District (D); Highway Service Business District (HSB); Industrial/Distribution District (I-D); Gateway Village District (GV); nonresidential use
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Primary Ground Sign - Interstate-Oriented (Nonresidential Lot) | 80 ft. | Max 672 sq ft per sign face (derived from 2 sq ft per linear ft formula and explicit maximum). | Not listed | Off right-of-way; at least 5 ft from public right-of-way; no portion may violate 5-ft setback. | One per nonresidential establishment on such lot; no additional primary ground signs on that premises. | On an individual nonresidential lot abutting interstate right-of-way or on property within 650 ft of the centerline of interstate right-of-way without direct road frontage on interstate. | Not listed | Unlock | Sec. 8-5-19A, item 1; footnote 1; definition of Nonresidential use, Sec. 8-5-4. |
| Primary Ground Sign - Individual Nonresidential Lot / Planned Office, Commercial, Industrial, or Retail Center | 20 ft. | Aggregate of all primary ground signs on the lot is: 0–10,000 sq ft gross building space: 200 sq ft; 10,001–50,000: 225 sq ft; 50,001–100,000: 250 sq ft; 100,000 and greater: 300 sq ft. No individual primary ground sign may exceed 50% of the total aggregate allowed. | Not listed | Off right-of-way; at least 5 ft from public right-of-way (footnote 1). | One primary ground sign per frontage; spacing min 200 ft between primary ground signs on same property. | On individual nonresidential lot or at planned office, commercial, industrial, or retail center, off right-of-way. | Not listed | Unlock | Sec. 8-5-19A, item 2. |
| Accessory Ground Sign - Nonresidential Lots and Centers | 3 ft. | 4 sq ft per sign face (accessory ground sign). | Not listed | Off right-of-way; at least 5 ft from public right-of-way. | Two sign structures per entrance. | On individual nonresidential lot or within planned office, commercial, industrial, or retail center, typically at entrances, off right-of-way. | Not listed | Unlock | Definition of Accessory ground sign, Sec. 8-5-4; Sec. 8-5-19A, item 6. |
| Wall Sign - Individual Nonresidential Establishment / Tenant Space - Gross Space 0–2,500 sq ft | Height of wall sign may not exceed height of building elevation. | Max 250 sq ft per elevation. | Not listed | Same as required for building. | Not numerically limited per ordinance; limited by maximum size per elevation and building extent. | Mounted on wall of building or tenant space in nonresidential use; same setbacks as building. | Not listed | Unlock | Definition of Wall sign, Sec. 8-5-4; Sec. 8-5-19A, item 8 – 0–2,500 row. |
| Wall Sign - Individual Nonresidential Establishment / Tenant Space - Gross Space 2,501–15,000 sq ft | Not greater than height of building elevation. | Max 300 sq ft per elevation. | Not listed | Building setback. | Limited by area per elevation. | Wall of nonresidential building / tenant space. | Not listed | Unlock | Sec. 8-5-19A, item 8 – 2,501–15,000 row. |
| Wall Sign - Individual Nonresidential Establishment / Tenant Space - Gross Space 15,001–50,000 sq ft | Not greater than building elevation height. | Max 400 sq ft per elevation. | Not listed | Building setback. | Limited by area per elevation. | Wall of nonresidential building / tenant space. | Not listed | Unlock | Sec. 8-5-19A, item 8 – 15,001–50,000 row. |
| Wall Sign - Individual Nonresidential Establishment / Tenant Space - Gross Space 50,000 sq ft or greater | Not greater than building elevation height. | Max 500 sq ft per elevation. | Not listed | Building setback. | Limited by area per elevation. | Wall of large nonresidential building / tenant space. | Not listed | Unlock | Sec. 8-5-19A, item 8 – 50,000, greater row. |
| Oversized Sign (Interstate-Oriented, Nonresidential Districts) | Max 48 ft to top of sign including structure. | Max 672 sq ft per face, 14 ft high by 48 ft long; up to 2 faces not exceeding 1,344 sq ft total. | Max 48 ft per face length. | Must be in buildable area; subject to 500–5,000 ft spacing and separation, not the standard 5‑ft sign setback. | Limited by spacing rules; effectively one per 500 ft of street frontage on same side. | Within nonresidential zoning districts on properties adjacent to interstate highways; must be in buildable area and structurally independent from buildings. | Not listed | Unlock | Sec. 8-5-20(1)-(8); definition Nonresidential use, Sec. 8-5-4. |
Run a code check for your exact address to get the zone that applies to your property, plus illumination rules, size formulas, and permit requirements for every sign type in Conyers with a free PermitPal account.
Run a free code checkProhibited Signs in Conyers
- Any sign erected, placed, established, painted, created, or maintained not in conformance with the standards, procedures, and other requirements of Chapter 5 is prohibited (Sec. 8-5-5(a)).
- Roof signs are prohibited except where specifically permitted in a particular zoning district (Sec. 8-5-13(1)).
- Portable signs are prohibited except where specifically permitted in a particular zoning district (Sec. 8-5-13(2)).
- Animated signs are prohibited except where specifically permitted in a particular zoning district (Sec. 8-5-13(3)).
- Use of exposed reflective type bulbs, strobe lights, incandescent lamps, or neon tube lighting on the exterior surface of any sign so as to expose the face of the bulb, light, lamp, or neon tube to any public street or adjacent property is prohibited, except for one neon sign allowed by Sec. 8-5-18(g); clear coverings that make such lighting appear exposed are likewise prohibited (Sec. 8-5-13(4)).
- Signs placed within public rights-of-way are prohibited, except signs installed and maintained by a governmental entity or signs identifying the location of utilities (Sec. 8-5-13(5)).
- Signs erected by painting, nailing, fastening, or affixing to any fence, tree, rock, post, curb, utility pole, natural feature, official street sign or marker, traffic control sign or device, or other structure are prohibited except as otherwise allowed in the ordinance (Sec. 8-5-13(6)).
- Any sign placed or erected on property without the permission of the owner is prohibited (Sec. 8-5-13(7)).
- Individual or aggregate window signs exceeding 30 percent of the window area per building elevation are prohibited (Sec. 8-5-13(8)).
- Signs containing words, pictures, or statements that are obscene are prohibited (Sec. 8-5-13(9)).
- Signs that simulate an official traffic control device, warning sign, or regulatory sign, or that hide from view any traffic control device, signal, or public service sign are prohibited (Sec. 8-5-13(10)).
- Signs that emit or utilize any sound capable of being detected on any traveled road or highway by a person with normal hearing are prohibited (Sec. 8-5-13(11)).
- Signs that interfere with road or highway visibility, obstruct or interfere with the safe and orderly movement of traffic, or pose a traffic hazard due to structural deficiencies are prohibited (Sec. 8-5-13(12)).
- Signs that obstruct any fire escape, any means of egress or ventilation, or prevent free passage from one part of a roof to any other part, including signs attached to any fire escape, are prohibited (Sec. 8-5-13(13)).
- Signs that do not conform to applicable building and electrical codes are prohibited (Sec. 8-5-13(14)).
- Signs that are in violation of the rules and regulations of any zoning overlay district are prohibited (Sec. 8-5-13(15)).
- Any sign constructed of nondurable material including, but not limited to, paper, cardboard, or flexible plastic that has been displayed for more than 60 days is prohibited (Sec. 8-5-13(16)).
- Signs located on any substandard lot created after enactment of this chapter, unless the substandard lot is created as the result of governmental action, are prohibited (Sec. 8-5-13(17)).
- Any sign that is structurally unsound, or is a hazard to traffic or pedestrians, is prohibited (Sec. 8-5-13(18)).
- Dilapidated or neglected signs (including sign structures) that do not present a neat and orderly appearance, as evidenced by rust/holes, broken/missing/bent parts, faded/flaking paint, nonoperative illumination or mechanical devices, or missing letters, are prohibited (Sec. 8-5-13(19)).
- Beacons are prohibited except where specifically permitted in a particular zoning district (Sec. 8-5-13(20)).
- Any signs, other than standard informational signs, located on a lot that does not have a zoning classification, or within the right-of-way of a railroad, are prohibited (Sec. 8-5-13(21)).
- Temporary signs may not be affixed in any manner to trees, street or light poles, utility poles, fences, or other sign structures (Sec. 8-5-14, final sentence).
- Except as permitted for oversized and commercial electronic variable message signs, signs may not use exposed reflective bulbs, strobe lights, or incandescent lamps on the exterior surface so as to expose the light source to any public right-of-way or adjacent property (Sec. 8-5-18(d)).
- No sign may give off light which glares, blinds, or otherwise adversely affects traffic or adjacent properties, or cast direct light upon adjacent properties and roadways; no illuminated sign may be constructed or maintained within 75 feet of the property line of any single-family residential lot (Sec. 8-5-18(a)).
- Except as permitted in Sec. 8-5-22, no sign may have blinking, flashing, or fluctuating lights or other devices with changing light intensity, brightness, or color, and no sign may be animated or simulate movement (Sec. 8-5-18(b)).
- Subject to Sec. 8-5-22, no sign may contain an electronic or computerized message changer unless specifically allowed as a commercial electronic variable message sign (Sec. 8-5-18(c), Sec. 8-5-22).
- Colored lights may not be used in a location or manner that could be confused with or construed as traffic control devices, and direct or reflected light from primary light sources may not create a hazard to motor vehicle operators (Sec. 8-5-18(e)).
- Signs within any residential district may not be internally illuminated and may only be indirectly illuminated (Sec. 8-5-18(f)).
- Placement of signs on vehicles, trailers, or non‑motorized vehicles, then parked or placed to expand advertising beyond what is permitted by Sec. 8-5-19A, is prohibited; a vehicle, trailer, or non‑motorized vehicle parked adjacent to the public right‑of‑way and more than 50 feet from its associated business’s main entrance is presumed to be in violation (Sec. 8-5-23(a)).
- Vehicle signs in the form of banners, A‑frame signs, temporary fixtures, and signs mounted in pickup beds or on the bed of flatbed trucks are prohibited (Sec. 8-5-23(c)).
- Any sign erected, altered, maintained, converted, or used in violation of Chapter 5, or in violation of applicable building or electrical codes, is subject to citation, penalties, and removal (Sec. 8-5-24(1)–(4)).
Exempt Signs in Conyers
- Display of address numerals not exceeding six inches in height for single‑family residential uses or 12 inches in height for all other uses is exempt from the sign permit requirement, provided all other standards are met (Sec. 8-5-16(1)).
- Any sign not visible from public thoroughfares or any sign located within a business, office, mall, or totally enclosed area is exempt from the sign permit requirement, provided all other standards are met (Sec. 8-5-16(2)).
- Window signs that do not exceed 30 percent of the available window space per building elevation are exempt from the sign permit requirement, provided all other standards are met (Sec. 8-5-16(3)).
- Swinging or projecting signs not exceeding three square feet in area, or projecting no more than four feet and attached under the eave or awning of a building above a business entrance, are exempt from the sign permit requirement, provided all other standards are met (Sec. 8-5-16(4)).
- One exposed neon sign per ground floor nonresidential use, meeting the standards of Sec. 8-5-18(g), is exempt from the sign permit requirement, provided all other standards are met (Sec. 8-5-16(5) and Sec. 8-5-18(g)).
- Standard informational signs with an aggregate sign area per lot (residential or nonresidential) of 18 square feet or less are exempt from the sign permit requirement, provided each such sign does not exceed six square feet in size, is no greater than four feet above the grade level of the adjacent street or three feet above ground level (whichever is greater), is not within the public right‑of‑way, is set back at least five feet from the public right‑of‑way, and is not attached to light poles, freestanding poles, utility poles, bollards, or similar structures (Sec. 8-5-16(6)).
- Flags displayed on purpose‑built, professionally fabricated flagpoles in compliance with Sec. 8-5-15 do not require a permit; no permit is necessary for the erection of a compliant flagpole (Sec. 8-5-15(a)).
Sign Plan & Submission Notes for Conyers
- All permanent ground and wall signs generally require a sign permit; applications must include site plans and building elevations as specified in Sec. 8-5-7. There is no separate master sign plan or coordinated sign plan requirement stated in the provided text.
- Ground signs: for any ground sign, a site plan drawn to scale showing all proposed primary and accessory ground signs on the property is required with the sign permit application. For ground signs 50 square feet or larger and/or 15 feet tall or higher, construction plans compliant with the International Building Code (including Appendix H, Section H105) stamped by a state‑registered professional engineer are required (Sec. 8-5-7(8)).
- Wall‑mounted signs: two sets of building elevations must be submitted with the sign permit application (Sec. 8-5-7(9)).
- Temporary signs, banners, air or gas filled devices, and balloons described in Sec. 8-5-14 require a temporary sign permit, which allows a 30‑day display period followed by a required 45‑day removal period before re‑application; a fee set by City Council applies to each temporary sign permit (Sec. 8-5-14).
- Oversized signs are allowed only in certain conditions and must comply with all sign permit application provisions and construction standards for signs, including those in Sec. 8-5-7 (Sec. 8-5-20(8)).
- Commercial electronic variable message signs are allowed in nonresidential districts; while the text does not specify an additional or distinct plan beyond the standard sign permit, such signs must meet the operational, brightness, and certification requirements of Sec. 8-5-22 and Sec. 8-5-18, which will affect sign permit review.
- Variances from sign regulations may be granted only for specific hardship situations related to visibility obstructions; hearings on such variances follow the same procedures, time frames, and notice requirements as appeals, but there is no indication of a separate sign master plan or sign design review board (Sec. 8-5-9).
Source: municode municipal code