Questions? Call us at (262) 218-2915

Sign Regulations in Marietta, Georgia

Marietta, Georgia has specific sign regulations covering 32 sign types across 6 zoning districts. Regulated sign types include Temporary Sign, Projecting Sign, Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: October 24, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Marietta, Georgia

Sample Sign Requirements in Marietta

Sign TypeMax Height
Projecting SignShall not extend above the parapet wall; minimum clear height of 8 feet above ground
Wall SignShall not extend above the parapet wall
Canopy SignShall not extend above the parapet wall; minimum clear height of 8 feet above ground

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for MariettaFull Coverage

Sign Types Covered

32

  • Temporary Sign
  • Projecting Sign
  • Wall Sign
  • Under Canopy Sign
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Marietta

City WebsiteMunicipal Code1 permit application link available

Marietta, Georgia Sign Rules at a Glance

Marietta, Georgia regulates 32 sign types across 6 zoning districts. Weekend Standard Informational Signs (WSIS) are capped at 4 feet tall and 6 square feet, set back 14 feet from back of curb or 1 foot behind right-of-way (Sec. 714.05F). Most commercial signs in Marietta require a permit.

Detailed Sign Ordinance Requirements for Marietta, Georgia

Sign Rules by Zoning District in Marietta (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax Area
General Regulations For All Zones1370 feet along interstate; 35 feet along U.S. 41672 square feet
SINGLE-FAMILY RESIDENTIAL (R-1, R-2, R-3, R-4, RA-4, RA-6, RA-8, PRD(SF), MHP)58 feet64 square feet
MULTIFAMILY RESIDENTIAL (RM-8, RM-10, RM-12, RHR, PRD(MF))910 feet60 square feet
COMMERCIAL (NRC, CRC, RRC, CBD, PCD, MXD, OIT, LRO, OI, OS, OHR)1770 feet I-75, 35 ft US 41672 square feet
INDUSTRIAL (LI, HI, PID)1170 ft I-75672 square feet
Downtown Marietta Sign District10Not above parapet; clear 8 ft90 square feet total (existing); 45 sq ft new/remodeled

Zone-by-Zone Sign Requirements in Marietta(sample of 3 of 6 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaSetbackSigns AllowedLocationPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Projecting SignShall not extend above the parapet wall; minimum clear height of 8 feet above groundNot listedNot listedNot listedSecurely fastened to building surface in nonresidential districtsUnlock714.04A
Under Canopy SignMinimum clear height of 8 feet above ground at lowest extremity6 square feetNot listedNot listedAttached to supporting structure underside of canopy in nonresidential districtsUnlock714.04D
Freestanding Sign - Monument StyleNot listedNot listedMinimum 5 feet from property line; additional as required by Public Works Director1 per 75 feet of frontage abutting public ROWOn private property, at least 5 feet from any property line; permitted in all districts except single-family residential unless specifically allowedUnlock714.04F, Table H
Freestanding Sign - Nostalgic StyleNot listedNot listedMinimum 5 feet from property line; additional as required by Public Works Director1 per 75 feet of frontage abutting public ROWOn private property, at least 5 feet from any property line; permitted in all districts except single-family residential unless specifically allowedUnlock714.04F, Table H
Billboard70 feet along interstate; 35 feet along U.S. 41672 square feetMeet zoning district setbacks; may reduce up to 50% to preserve trees with survey and GDOT approval; sign faces may extend 25% into setbackNot listedWithin 100 feet of ROW of I-75 or U.S. 41; permitted in LI, HI, CRC, RRC, PCD, OHRUnlock714.04G
Temporary SignNot listedNot listedFor seasonal detached: 12 feet from property line1 per lot (or per tenant in centers)On building face abutting public street or access drive; in nonres and multi-family districtsUnlock714.05E
A-frame Sign4 feet10 square feetMore than 10 feet from property line1 per storefrontOn private property, >10 ft from property line, within 15 ft of front door, on adjacent sidewalk; not blocking passageUnlock714.03K
Weekend Standard Informational Sign (WSIS)4 feet6 square feet14 feet from back of curb or 1 foot behind ROW1 per 300 feet of road frontageIn nonresidential districts, 1 per 300 ft road frontage, within 3-mile radius of destination; >14 ft from back of curb or 1 ft behind ROWUnlock714.05F

MULTIFAMILY RESIDENTIAL (RM-8, RM-10, RM-12, RHR, PRD(MF))

Sign TypeMax HeightMax AreaSetbackSigns AllowedLocationPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Freestanding Sign - Monument Style - Arterial10 feet60 square feetMinimum 5 feet; additional for safety1 per 75 feet frontageAt least 5 feet from property lineUnlock714.04F, Table H
Freestanding Sign - Monument Style - Collector8 feet40 square feetMinimum 5 feet; additional for safety1 per 75 feet frontageAt least 5 feet from property lineUnlock714.04F, Table H
Freestanding Sign - Monument Style - Local6 feet24 square feetMinimum 5 feet; additional for safety1 per 75 feet frontageAt least 5 feet from property lineUnlock714.04F, Table H
Freestanding Sign - Nostalgic Style - Local6 feet12 square feetMinimum 5 feet; additional for safety1 per 75 feet frontageAt least 5 feet from property lineUnlock714.04F, Table H
Freestanding Sign - Nostalgic Style - Collector/Arterial8 feet20 square feetMinimum 5 feet; additional for safety1 per 75 feet frontageAt least 5 feet from property lineUnlock714.04F, Table H
Standard Informational Sign4 feet6 square feetAt least 1 foot from ROWAs per general residential rulesOn propertyUnlock714.03F
Freestanding Sign - Monument - Places of Assembly, Parks, Cemeteries8 feet32 square feet5 feet minimum1 per 75 ft frontageOn parcels with places of assembly, parks, cemeteriesUnlock714.05L
Development Project SignNot listed15 square feetNot listed1At construction site >=2 acresUnlock714.03E

COMMERCIAL (NRC, CRC, RRC, CBD, PCD, MXD, OIT, LRO, OI, OS, OHR)

Sign TypeMax HeightMax AreaSetbackSigns AllowedLocationPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Under Canopy SignClear 8 ft6 square feetNot listedNot listedUnder canopyUnlock714.04D
Freestanding Sign - Monument Style - Arterial15 feet90 square feet5 ft min1 per 75 ft5 ft from property lineUnlock714.04F, Table H
Freestanding Sign - Monument Style - Tier A8 feet60 square feet5 ft min1 per 75 ft5 ft from property lineUnlock714.04F, Table H
Freestanding Sign - Monument Style - Collector/Industrial10 feet50 square feet5 ft min1 per 75 ft5 ft from property lineUnlock714.04F, Table H
Freestanding Sign - Monument Style - Local8 feet30 square feet5 ft min1 per 75 ft5 ft from property lineUnlock714.04F, Table H
Freestanding Sign - Nostalgic Style - Local6 feet12 square feet5 ft min1 per 75 ft5 ft from property lineUnlock714.04F, Table H
Freestanding Sign - Nostalgic Style - Collector/Arterial8 feet20 square feet5 ft min1 per 75 ft5 ft from property lineUnlock714.04F, Table H
Billboard70 feet I-75, 35 ft US 41672 square feetZoning setbacksNot listedWithin 100 ft ROW I-75/US 41Unlock714.04G

PermitPal covers all 6 zoning districts in Marietta. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Marietta

  • Pylon signs.
  • Signs, fliers, bills, posters, or any other such object placed upon or affixed to sidewalks, curbs, or public rights-of-way or any publicly owned building or structure.
  • Signs attached to a fence, fence post, tree, tree trunk, street sign, or utility pole or painted on or otherwise attached to a rock or other natural objects.
  • Signs which emit sound, odor, or visible matter such as smoke or vapor.
  • Flashing or blinking signs, or signs using varying light intensity.
  • Rotating signs or animated signs involving motion of the body of the sign.
  • Signs that advertise an activity that is illegal under local, state, or federal laws or regulations.
  • Signs which are erected or maintained that obstruct any fire escape, any means of egress or ventilation, or which prevent free passage from one part of a roof to any other part thereof, or attached in any manner to a fire escape.
  • Portable display signs or trailer display signs.
  • Billboards located on property which has an existing sign.
  • Pennants or other nonpermanent displays attached together or to a building, vehicle or other object by rope, string, wire or other device.
  • Abandoned or dilapidated signs.
  • Air- and gas-filled devices greater than 2 feet in diameter, except as permitted under other provisions.
  • Roof signs or signs where a portion of the sign extends above the roof of the building where the sign is located.
  • No sign, noise emission or revolving beam or beacon of light shall be erected at any location where by reason of the position, shape or color it may interfere with, obstruct the view of, or be confused with any authorized traffic sign, signal or device.
  • No sign or other obstruction to vision, except utility poles, light or street sign standards or tree trunks shall be permitted within 15 feet of the intersection of the right-of-way lines of streets, roads, highways or railroads.

Exempt Signs in Marietta

  • Signs, notices and traffic signs conforming to the standards of the Manual of Uniform Traffic Control Devices or other federal or state standard.
  • Flags that are attached to a flagpole mounted on the ground or to flagstaffs attached to the facade of a structure, limited to 3 flags per premises, plus 1 additional flag for every 10 feet of road frontage.
  • Incidental signs. Incidental signs that are visible from the public right-of-way are limited to 6 square feet per sign face and 3 feet in height, limited to 1 per curb cut. Incidental signs that are not visible from the public right-of-way are limited to 20 square feet per sign face and 8 feet in height.
  • Delivery receptacles for mail and newsprint deliveries.
  • One sign not to exceed 15 square feet for development projects involving 2 or more acres in residential districts or 50 square feet in non-residential districts placed at a location under construction or alteration. All such signs shall be removed from the site upon issuance of a certificate of occupancy.
  • Standard informational signs in residential districts that otherwise meet the standards of this division.
  • Window signs meeting the standards of this division.
  • Building address numerals not exceeding 12 inches in height in residential districts and 24 inches in height in nonresidential districts and emergency information.
  • Inflatable devices or balloons.
  • Panel replacements. The changing of a sign face or panel in or on an existing approved sign or a legally nonconforming sign shall not require a sign permit. However, if the proposed panel replacement creates a need for structural repair or causes a change in the size, shape, location, or design of the sign, then a sign permit shall be required to bring the sign into compliance with the requirements of this division.
  • A-frame signs placed on private property and directed toward pedestrians, subject to specific conditions including location, size, and usage restrictions.

Source: municode municipal code

Frequently Asked Questions

In Marietta, the height limit for Freestanding Sign - Monument - Places of Assembly, Parks, Cemeteries in the MULTIFAMILY RESIDENTIAL (RM-8, RM-10, RM-12, RHR, PRD(MF)) zoning districts is 8 feet (Sec. 714.05L). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Marietta's sign code covers 32 sign types, including Temporary Sign, Projecting Sign, Wall Sign, and Under Canopy Sign. Most commercial signs need a permit. The ordinance lists 11 exemptions. One of them: Inflatable devices or balloons. The full list is on this page.

In Marietta, Freestanding Sign - Monument - Places of Assembly, Parks, Cemeteries in the MULTIFAMILY RESIDENTIAL (RM-8, RM-10, RM-12, RHR, PRD(MF)) zoning districts must be set back at least 5 feet (Sec. 714.05L). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Marietta's sign ordinance that cover digital, changing, or flashing signs: Flashing or blinking signs, or signs using varying light intensity. Rotating signs or animated signs involving motion of the body of the sign. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Marietta Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Marietta, Georgia, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds