Sign Regulations in Tucker, Georgia

Tucker, Georgia has specific sign regulations covering 16 sign types across 6 zoning districts. Regulated sign types include Entrance Sign, Directional Sign, Flags (Exempt). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 9, 2025

Sign Regulation Overview for Tucker, Georgia

Sample Sign Requirements in Tucker

Sign TypeMax HeightMax AreaSetback
Entrance Sign8 ft (under 30 acres); 20 ft (30 acres+)32 sq ft (developments under 30 acres); 300 sq ft (developments 30 acres or larger)
Monument Sign / Double-post Sign12 ft (under 30 acres); 20 ft (30 acres+)150 sq ft (developments under 30 acres); 270 sq ft (30 acres+)Set at least 10 ft from electrical transmission lines
Directional Sign3 ft6 sq ftAt least 10 ft from electrical transmission lines

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for TuckerFull Coverage

Sign Types Covered

16

  • Entrance Sign
  • Directional Sign
  • Flags (Exempt)
  • Sandwich Board Sign
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Tucker

City WebsiteMunicipal Code6 permit application links available

Frequently Asked Questions

In Tucker, monument signs are limited to 12 ft (under 30 acres); 20 ft (30 acres+). Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Tucker, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Tucker, regulated sign types include Entrance Sign, Directional Sign, Flags (Exempt), Sandwich Board Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Tucker, monument signs typically require a Set at least 10 ft from electrical transmission lines setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Tucker are regulated with specific requirements for brightness, animation, and message duration. Tucker has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Tucker Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Tucker, Georgia sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Tucker, Georgia Sign Rules at a Glance

Tucker, Georgia regulates 16 sign types across 6 zoning districts. Monument Sign / Double-post Signs in the Non-Residential Zoning Districts zoning district are capped at 12 ft (under 30 acres); 20 ft (30 acres+) tall, 150 sq ft (monument/double-post, under 30 acres); 270 sq ft (30 acres+), and 15 ft wide, with a Set at least 10 ft from electrical transmission lines setback (Sec. Sec. 34-61, Sec. 34-62). Most commercial signs in Tucker require a permit.

Detailed Sign Ordinance Requirements for Tucker, Georgia

Sign Rules by Zoning District in Tucker (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential Zoning Districts7Pole max 25 ft or height of primary structure, whichever less150 sq ft (developments under 30 acres); 270 sq ft (30 acres+)
Non-Residential Zoning Districts8Max pole height per district, or 60 ft, whichever is less150 sq ft (developments under 30 acres); 500 sq ft (30 acres+)
DT Districts (DT-1, DT-2, DT-3)8District max or 60 ft, whichever is less90 sq ft
NL Districts (NL-4)8District max or 60 ft, whichever is less90 sq ft (monument or double-post)
Mountain Industrial Boulevard Overlay23.5 ft (42 in)7 sq ft per side
General Regulations For All Zones38 ftCombined signs/devices: 150 sq ft

Zone-by-Zone Sign Requirements in Tucker(sample of 3 of 6 zones)

Non-Residential Zoning Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Awning Sign / Canopy Sign / Wall Sign (Primary Facade)150 sq ft (developments under 30 acres); 500 sq ft (30 acres+)Max 80% of awning/canopy/wall width. Projection: awning/canopy 6 ft, wall 2 ft1 per primary facade (each: awning OR canopy OR wall sign); 1 per secondary facadeAlong primary facade, not above building/parapet wall, not on roofUnlockSec. 34-55 Table 21.1, Sec. 34-56, Sec. 34-57, Sec. 34-58, Sec. 34-59
Projecting Sign9 sq ft1 per primary facade, 1 per secondary facadePrimary or secondary facade only, not above building/parapet wall, not on roofUnlockSec. 34-60
Monument Sign / Double-post Sign12 ft (under 30 acres); 20 ft (30 acres+)150 sq ft (monument/double-post, under 30 acres); 270 sq ft (30 acres+)15 ftSet at least 10 ft from electrical transmission linesOne per street frontage; only one (monument or double-post) per street allowedBetween facade and street it facesUnlockSec. 34-61, Sec. 34-62
Sandwich Board Sign42 in (3.5 ft)7 sq ft per sideOne per establishmentWithin private property, not in public right-of-wayUnlockSec. 34-63
Entrance Sign8 ft (under 30 acres); 20 ft (30 acres+)32 sq ft (under 30 acres); 300 sq ft (30 acres+)15 ftOne per entrance or driveway, 500 ft minimum separationAt each street entrance/driveway; not less than 500 ft apart on same devUnlockSec. 34-64
Directional Sign3 ft6 sq ft3 ftAt least 10 ft from electrical transmission lines2 per curb, max 8 per lotOn private property, at least 10 ft from electrical transmission linesUnlockSec. 34-65
Flags (Exempt)Max pole height per district, or 60 ft, whichever is lessUp to 24 sq ft (pole up to 25 ft), 40 sq ft (25-39 ft), 60 sq ft (40-49 ft), 99 sq ft (50-60 ft); hoist max 20% pole heightSetback at least height of pole from property boundary3 flagpoles/lot, 2 flags/poleFlagpoles set back at least height of pole from property boundaryUnlockSec. 34-53(2)
Window Sign (Exempt - see illumination rules)Max 30% of window area; neon/internal illum: 3 sq ft each, 8 ft separationUnlimited, but see % window, size, and spacing restrictionsIn/on windowUnlockSec. 34-53(3)

DT Districts (DT-1, DT-2, DT-3)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Awning Sign / Canopy Sign / Wall Sign (Primary Facade)32 sq ftMax 80% of awning/canopy/wall width. Projection: awning/canopy 6 ft, wall 2 ft1 per primary facade (awning/canopy/wall sign); 1 per secondary facadeOn ground story doors/windows or parallel to building facadeUnlockSec. 34-55 Table 21.1, Sec. 34-56, Sec. 34-57, Sec. 34-58, Sec. 34-59, Sec. 34-66
Projecting Sign9 sq ftOne per primary, one per secondary facadePrimary or secondary facade only; not above building/parapet wall, not on roofUnlockSec. 34-60
Monument Sign / Double-post Sign8 ft90 sq ft15 ftAt least 10 ft from electrical transmission lines; if building is less than 5 ft from public right-of-way, no ground sign may be placed between building and right-of-wayOne per street frontageBetween facade and street it facesUnlockSec. 34-61, Sec. 34-62
Sandwich Board Sign3.5 ft (42 in)7 sq ft per sideOne per establishmentOn private property; not in public right-of-wayUnlockSec. 34-63, Sec. 34-68
Entrance Sign8 ft (under 30 acres); 20 ft (30 acres+)32 sq ft (under 30 acres); 300 sq ft (30 acres+)15 ftOne per entrance, 500 ft separationAt each street entrance or driveway; not less than 500 ft apart on same devUnlockSec. 34-64
Directional Sign3 ft6 sq ft3 ftAt least 10 ft from electrical transmission lines2 per curb, 8 per lotOn private property, at least 10 ft from electrical transmission linesUnlockSec. 34-65
Flags (Exempt)District max or 60 ft, whichever is lessUp to 24 sq ft (pole up to 25 ft), 40 sq ft (25-39 ft), 60 sq ft (40-49 ft), 99 sq ft (50-60 ft); hoist max 20% pole heightAt least height of pole from lot boundaries3 flagpoles/lot, 2 flags/poleFlagpoles set back at least height of pole from property boundaryUnlockSec. 34-53(2)
Window Sign (Exempt - see illumination rules)Max 30% of window area; neon/internal illum: 3 sq ft each, 8 ft separationUnlimited, but see percentage, size, and spacing restrictionsIn/on windowUnlockSec. 34-53(3), Sec. 34-66(1)

NL Districts (NL-4)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Awning Sign / Canopy Sign / Wall Sign (Primary Facade)32 sq ftMax 80% of wall/awning/canopy width. Projection (awning/canopy): 6 ft, wall: 2 ftOne per primary facade, one per secondary facadePrimary or secondary facade onlyUnlockSec. 34-56, Sec. 34-57, Sec. 34-58, Sec. 34-59, Sec. 34-67
Projecting Sign9 sq ftOne per primary, one per secondary facadePrimary or secondary facades onlyUnlockSec. 34-60
Monument Sign / Double-post Sign (Externally Illuminated only)8 ft90 sq ft (monument or double-post)15 ftAt least 10 ft from electrical transmission linesOne per street frontageBetween the primary/secondary facade and the street it facesUnlockSec. 34-61, Sec. 34-62, Sec. 34-67
Sandwich Board Sign3.5 ft (42 in)7 sq ft per sideOne per establishmentOn private property; not in public right-of-wayUnlockSec. 34-63
Entrance Sign8 ft (under 30 acres); 20 ft (30 acres+)32 sq ft (under 30 acres); 300 sq ft (30 acres+)15 ftOne per entrance, 500 ft separationAt each street entrance or driveway; not less than 500 ft apart on same devUnlockSec. 34-64
Directional Sign3 ft6 sq ft3 ftAt least 10 ft from electrical transmission lines2 per curb, 8 per lotOn private property, at least 10 ft from electrical transmission linesUnlockSec. 34-65
Flags (Exempt)District max or 60 ft, whichever is lessUp to 24 sq ft (pole up to 25 ft), 40 sq ft (25-39 ft), 60 sq ft (40-49 ft), 99 sq ft (50-60 ft); hoist max 20% pole heightAt least height of pole from lot boundaries3 flagpoles/lot, 2 flags/poleFlagpoles set back at least height of pole from property boundaryUnlockSec. 34-53(2)
Window Sign (Exempt - see illumination rules)Max 30% of window area; neon/internal illum: 3 sq ft each, 8 ft separationUnlimited, but see percent, size, and spacing restrictionsIn/on windowUnlockSec. 34-53(3), Sec. 34-67(1)

PermitPal covers all 6 zoning districts in Tucker — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 6 zones for Tucker — start free

Prohibited Signs in Tucker

  • Signs on any right-of-way other than publicly owned or maintained signs and signs pertaining to railroad crossings.
  • Signs that contain words, pictures, statements, or any other materials which are obscene, as defined by O.C.G.A. § 16-12-80, as amended.
  • Signs, except flags allowed by section 34-53(2), that simulate an official traffic control device, warning sign, or regulatory sign or which hide from view any traffic control device, signal, or public service sign.
  • Signs that emit or utilize in any manner any sound capable of being detected on any traveled road, highway, or adjacent sidewalk by a person with normal hearing abilities.
  • Signs that interfere with road or highway visibility, or that obstruct or otherwise interfere with the safe and orderly movement of traffic, or that otherwise pose a hazard to traffic due to structural deficiencies in the structure of such signs.
  • Signs erected by nailing, fastening or affixing the sign in any manner to any tree, curb, utility pole, natural feature, or other structure except as may be set forth herein.
  • Animated signs, including rotating or revolving signs (except for time and weather informational signs, official warning and other regulatory signs).
  • Electronic signs.
  • Neon signs, except as authorized under section 34-53(3) for window signs.
  • Signs that obstruct any fire escape, any means of egress or ventilation or prevent free passage from one part of a roof to any other part thereof, as well as signs attached to any fire escape.
  • Signs that cover and obscure windows, doors, cornices, or other architectural features.
  • Signs that do not conform to applicable building and electrical codes.
  • Signs for which a permit is required that do not display the sign permit number.
  • Monopole signs and other signs with exposed structural supports that are more than three feet in height and have post supports larger than two inches in diameter or a total of four-square inches in cross-section area, except for authorized double-post signs in DT districts.
  • Roof signs.
  • Tri-faced signs.
  • Signs that are in violation of the rules and regulations of any special district or overlay district presently existing or as may later be enacted.
  • Any sign constructed of non-durable material including, but not limited to, paper, cardboard, fabric, or flexible plastic. This provision does not apply to flags, awning signs, or banners which are otherwise allowed by this chapter.
  • Portable signs, except authorized sandwich board signs.
  • Signs attached to, painted on, or otherwise positioned in or on any vehicle or truck that is located in view of the street right-of-way when in a location or for a period of time that indicates that the use of the vehicle is for displaying the sign to passing motorists or pedestrians, except that such signs are allowed on a temporary basis in association with a temporary event permit.
  • Signs located on any substandard lot created after the enactment of this chapter unless the substandard lot is created as the result of governmental action.
  • Abandoned signs in a non-residential zoning district, DT district, and NL district (defined as signs related to a use discontinued for six months, unless proof of continued use is provided to the director).
  • Any sign that is structurally unsound or is a hazard to traffic or pedestrians.
  • Dilapidated or neglected signs (i.e., signs not maintained, with broken parts, rust, flaking paint, missing letters, etc.).
  • Window shades used as signs.
  • Illegal signs.

Exempt Signs in Tucker

  • Signs erected by a public officer in the performance of their duties, including but not limited to: public notices, safety signs, danger signs, official traffic control devices, memorial plaques, and historical markers.
  • Flags (subject to flagpole and size requirements in section 34-53(2)).
  • Window signs that do not exceed 30 percent of the window area and other stated limitations.
  • One internally illuminated window sign stating 'open' and/or 'closed' per establishment, not exceeding three square feet and included in the 30 percent window sign area limitation.
  • Neon window signs meeting applicable area and separation requirements.
  • Certain residential district signs as specified (with area, height, and illumination restrictions).
  • One suspended sign per tenant or dwelling unit when under six square feet per side.
  • Street number signs and other signs required by law.
  • Nongovernmental traffic control devices in or adjacent to parking areas and driveways and signs located at railroad crossings.
  • Historic signs meeting detailed age, documentation, and approval requirements as specified in section 34-53(8).

Sign Plan & Submission Notes for Tucker

  • On developments 30 acres or larger, the planning and zoning director may approve alternative sign materials when those materials are part of the development's overall design program. Applicants must submit evidence of the development's overall design program, which may include, but is not limited to, a master sign plan, architectural pattern book, renderings, or other items conveying the development's character and design to the director's satisfaction. (Sec. 34-76)
  • Alternative compliance via master sign plan or similar documentation is only available for developments 30 acres or larger and does not permit prohibited materials or sign types as set forth in section 34-52. (Sec. 34-76)
  • A variance for signs may be granted by the zoning board of appeals in specified cases meeting strict hardship criteria, but no variance may be granted to allow a prohibited sign or to increase the aggregate sign area permitted on a lot. (Sec. 34-75)