Tucker, Georgia has specific sign regulations covering 16 sign types across 6 zoning districts. Regulated sign types include Entrance Sign, Directional Sign, Flags (Exempt). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 9, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Tucker, Georgia
Sample Sign Requirements in Tucker
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Entrance Sign | 8 ft (under 30 acres); 20 ft (30 acres+) | 32 sq ft (developments under 30 acres); 300 sq ft (developments 30 acres or larger) | Not listed |
| Monument Sign / Double-post Sign | 12 ft (under 30 acres); 20 ft (30 acres+) | 150 sq ft (developments under 30 acres); 270 sq ft (30 acres+) | Set at least 10 ft from electrical transmission lines |
| Directional Sign | 3 ft | 6 sq ft | At least 10 ft from electrical transmission lines |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
16
- Entrance Sign
- Directional Sign
- Flags (Exempt)
- Sandwich Board Sign
- +2 more types
Zoning Districts
6
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Tucker
Other Cities in Georgia
Frequently Asked Questions
In Tucker, the height limit for Monument Sign / Double-post Sign in the Non-Residential Zoning Districts is 12 ft (under 30 acres); 20 ft (30 acres+). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Tucker require a permit. From the submission notes on this page: Alternative compliance via master sign plan or similar documentation is only available for developments 30 acres or larger and does not permit prohibited materials or sign types as set forth in section 34-52. (Sec. 34-76). Run a code check for an exact address to see the permit requirements for that zone.
Tucker's sign code covers 16 sign types, including Entrance Sign, Directional Sign, Flags (Exempt), and Sandwich Board Sign. Most commercial signs need a permit. The ordinance lists 10 exemptions. One of them: Street number signs and other signs required by law. The full list is on this page.
In Tucker, Monument Sign / Double-post Sign (Externally Illuminated only) in the NL Districts (NL-4) must be set back at least 10 ft from electrical transmission lines. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Tucker's sign ordinance that cover digital, changing, or flashing signs: Animated signs, including rotating or revolving signs (except for time and weather informational signs, official warning and other regulatory signs). Electronic signs. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Tucker Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Tucker, Georgia, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Tucker, Georgia Sign Rules at a Glance
Tucker, Georgia regulates 16 sign types across 6 zoning districts. Directional Signs in the NL Districts (NL-4) are capped at 3 ft tall, 6 sq ft, and 3 ft wide, set back at least 10 ft from electrical transmission lines (Sec. 34-65). Most commercial signs in Tucker require a permit.
Detailed Sign Ordinance Requirements for Tucker, Georgia
Sign Rules by Zoning District in Tucker (6 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Residential Zoning Districts | 7 | Pole max 25 ft or height of primary structure, whichever less | 150 sq ft (developments under 30 acres); 270 sq ft (30 acres+) | Not listed |
| Non-Residential Zoning Districts | 8 | Max pole height per district, or 60 ft, whichever is less | 150 sq ft (developments under 30 acres); 500 sq ft (30 acres+) | Not listed |
| DT Districts (DT-1, DT-2, DT-3) | 8 | District max or 60 ft, whichever is less | 90 sq ft | Not listed |
| NL Districts (NL-4) | 8 | District max or 60 ft, whichever is less | 90 sq ft (monument or double-post) | Not listed |
| Mountain Industrial Boulevard Overlay | 2 | 3.5 ft (42 in) | 7 sq ft per side | Not listed |
| General Regulations For All Zones | 3 | 8 ft | Combined signs/devices: 150 sq ft | Not listed |
Zone-by-Zone Sign Requirements in Tucker(sample of 3 of 6 zones)
Non-Residential Zoning Districts
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign / Canopy Sign / Wall Sign (Primary Facade) | Not listed | 150 sq ft (developments under 30 acres); 500 sq ft (30 acres+) | Max 80% of awning/canopy/wall width. Projection: awning/canopy 6 ft, wall 2 ft | Not listed | 1 per primary facade (each: awning OR canopy OR wall sign); 1 per secondary facade | Along primary facade, not above building/parapet wall, not on roof | Not listed | Unlock | Sec. 34-55 Table 21.1, Sec. 34-56, Sec. 34-57, Sec. 34-58, Sec. 34-59 |
| Projecting Sign | Not listed | 9 sq ft | Not listed | Not listed | 1 per primary facade, 1 per secondary facade | Primary or secondary facade only, not above building/parapet wall, not on roof | Not listed | Unlock | Sec. 34-60 |
| Monument Sign / Double-post Sign | 12 ft (under 30 acres); 20 ft (30 acres+) | 150 sq ft (monument/double-post, under 30 acres); 270 sq ft (30 acres+) | 15 ft | Set at least 10 ft from electrical transmission lines | One per street frontage; only one (monument or double-post) per street allowed | Between facade and street it faces | Not listed | Unlock | Sec. 34-61, Sec. 34-62 |
| Sandwich Board Sign | 42 in (3.5 ft) | 7 sq ft per side | Not listed | Not listed | One per establishment | Within private property, not in public right-of-way | Not listed | Unlock | Sec. 34-63 |
| Entrance Sign | 8 ft (under 30 acres); 20 ft (30 acres+) | 32 sq ft (under 30 acres); 300 sq ft (30 acres+) | 15 ft | Not listed | One per entrance or driveway, 500 ft minimum separation | At each street entrance/driveway; not less than 500 ft apart on same dev | Not listed | Unlock | Sec. 34-64 |
| Directional Sign | 3 ft | 6 sq ft | 3 ft | At least 10 ft from electrical transmission lines | 2 per curb, max 8 per lot | On private property, at least 10 ft from electrical transmission lines | Not listed | Unlock | Sec. 34-65 |
| Flags (Exempt) | Max pole height per district, or 60 ft, whichever is less | Up to 24 sq ft (pole up to 25 ft), 40 sq ft (25-39 ft), 60 sq ft (40-49 ft), 99 sq ft (50-60 ft); hoist max 20% pole height | Not listed | Setback at least height of pole from property boundary | 3 flagpoles/lot, 2 flags/pole | Flagpoles set back at least height of pole from property boundary | Not listed | Unlock | Sec. 34-53(2) |
| Window Sign (Exempt - see illumination rules) | Not listed | Max 30% of window area; neon/internal illum: 3 sq ft each, 8 ft separation | Not listed | Not listed | Unlimited, but see % window, size, and spacing restrictions | In/on window | Not listed | Unlock | Sec. 34-53(3) |
DT Districts (DT-1, DT-2, DT-3)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign / Canopy Sign / Wall Sign (Primary Facade) | Not listed | 32 sq ft | Max 80% of awning/canopy/wall width. Projection: awning/canopy 6 ft, wall 2 ft | Not listed | 1 per primary facade (awning/canopy/wall sign); 1 per secondary facade | On ground story doors/windows or parallel to building facade | Not listed | Unlock | Sec. 34-55 Table 21.1, Sec. 34-56, Sec. 34-57, Sec. 34-58, Sec. 34-59, Sec. 34-66 |
| Projecting Sign | Not listed | 9 sq ft | Not listed | Not listed | One per primary, one per secondary facade | Primary or secondary facade only; not above building/parapet wall, not on roof | Not listed | Unlock | Sec. 34-60 |
| Monument Sign / Double-post Sign | 8 ft | 90 sq ft | 15 ft | At least 10 ft from electrical transmission lines; if building is less than 5 ft from public right-of-way, no ground sign may be placed between building and right-of-way | One per street frontage | Between facade and street it faces | Not listed | Unlock | Sec. 34-61, Sec. 34-62 |
| Sandwich Board Sign | 3.5 ft (42 in) | 7 sq ft per side | Not listed | Not listed | One per establishment | On private property; not in public right-of-way | Not listed | Unlock | Sec. 34-63, Sec. 34-68 |
| Entrance Sign | 8 ft (under 30 acres); 20 ft (30 acres+) | 32 sq ft (under 30 acres); 300 sq ft (30 acres+) | 15 ft | Not listed | One per entrance, 500 ft separation | At each street entrance or driveway; not less than 500 ft apart on same dev | Not listed | Unlock | Sec. 34-64 |
| Directional Sign | 3 ft | 6 sq ft | 3 ft | At least 10 ft from electrical transmission lines | 2 per curb, 8 per lot | On private property, at least 10 ft from electrical transmission lines | Not listed | Unlock | Sec. 34-65 |
| Flags (Exempt) | District max or 60 ft, whichever is less | Up to 24 sq ft (pole up to 25 ft), 40 sq ft (25-39 ft), 60 sq ft (40-49 ft), 99 sq ft (50-60 ft); hoist max 20% pole height | Not listed | At least height of pole from lot boundaries | 3 flagpoles/lot, 2 flags/pole | Flagpoles set back at least height of pole from property boundary | Not listed | Unlock | Sec. 34-53(2) |
| Window Sign (Exempt - see illumination rules) | Not listed | Max 30% of window area; neon/internal illum: 3 sq ft each, 8 ft separation | Not listed | Not listed | Unlimited, but see percentage, size, and spacing restrictions | In/on window | Not listed | Unlock | Sec. 34-53(3), Sec. 34-66(1) |
NL Districts (NL-4)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Awning Sign / Canopy Sign / Wall Sign (Primary Facade) | Not listed | 32 sq ft | Max 80% of wall/awning/canopy width. Projection (awning/canopy): 6 ft, wall: 2 ft | Not listed | One per primary facade, one per secondary facade | Primary or secondary facade only | Not listed | Unlock | Sec. 34-56, Sec. 34-57, Sec. 34-58, Sec. 34-59, Sec. 34-67 |
| Projecting Sign | Not listed | 9 sq ft | Not listed | Not listed | One per primary, one per secondary facade | Primary or secondary facades only | Not listed | Unlock | Sec. 34-60 |
| Monument Sign / Double-post Sign (Externally Illuminated only) | 8 ft | 90 sq ft (monument or double-post) | 15 ft | At least 10 ft from electrical transmission lines | One per street frontage | Between the primary/secondary facade and the street it faces | Not listed | Unlock | Sec. 34-61, Sec. 34-62, Sec. 34-67 |
| Sandwich Board Sign | 3.5 ft (42 in) | 7 sq ft per side | Not listed | Not listed | One per establishment | On private property; not in public right-of-way | Not listed | Unlock | Sec. 34-63 |
| Entrance Sign | 8 ft (under 30 acres); 20 ft (30 acres+) | 32 sq ft (under 30 acres); 300 sq ft (30 acres+) | 15 ft | Not listed | One per entrance, 500 ft separation | At each street entrance or driveway; not less than 500 ft apart on same dev | Not listed | Unlock | Sec. 34-64 |
| Directional Sign | 3 ft | 6 sq ft | 3 ft | At least 10 ft from electrical transmission lines | 2 per curb, 8 per lot | On private property, at least 10 ft from electrical transmission lines | Not listed | Unlock | Sec. 34-65 |
| Flags (Exempt) | District max or 60 ft, whichever is less | Up to 24 sq ft (pole up to 25 ft), 40 sq ft (25-39 ft), 60 sq ft (40-49 ft), 99 sq ft (50-60 ft); hoist max 20% pole height | Not listed | At least height of pole from lot boundaries | 3 flagpoles/lot, 2 flags/pole | Flagpoles set back at least height of pole from property boundary | Not listed | Unlock | Sec. 34-53(2) |
| Window Sign (Exempt - see illumination rules) | Not listed | Max 30% of window area; neon/internal illum: 3 sq ft each, 8 ft separation | Not listed | Not listed | Unlimited, but see percent, size, and spacing restrictions | In/on window | Not listed | Unlock | Sec. 34-53(3), Sec. 34-67(1) |
PermitPal covers all 6 zoning districts in Tucker. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Tucker
- Signs on any right-of-way other than publicly owned or maintained signs and signs pertaining to railroad crossings.
- Signs that contain words, pictures, statements, or any other materials which are obscene, as defined by O.C.G.A. ยง 16-12-80, as amended.
- Signs, except flags allowed by section 34-53(2), that simulate an official traffic control device, warning sign, or regulatory sign or which hide from view any traffic control device, signal, or public service sign.
- Signs that emit or utilize in any manner any sound capable of being detected on any traveled road, highway, or adjacent sidewalk by a person with normal hearing abilities.
- Signs that interfere with road or highway visibility, or that obstruct or otherwise interfere with the safe and orderly movement of traffic, or that otherwise pose a hazard to traffic due to structural deficiencies in the structure of such signs.
- Signs erected by nailing, fastening or affixing the sign in any manner to any tree, curb, utility pole, natural feature, or other structure except as may be set forth herein.
- Animated signs, including rotating or revolving signs (except for time and weather informational signs, official warning and other regulatory signs).
- Electronic signs.
- Neon signs, except as authorized under section 34-53(3) for window signs.
- Signs that obstruct any fire escape, any means of egress or ventilation or prevent free passage from one part of a roof to any other part thereof, as well as signs attached to any fire escape.
- Signs that cover and obscure windows, doors, cornices, or other architectural features.
- Signs that do not conform to applicable building and electrical codes.
- Signs for which a permit is required that do not display the sign permit number.
- Monopole signs and other signs with exposed structural supports that are more than three feet in height and have post supports larger than two inches in diameter or a total of four-square inches in cross-section area, except for authorized double-post signs in DT districts.
- Roof signs.
- Tri-faced signs.
- Signs that are in violation of the rules and regulations of any special district or overlay district presently existing or as may later be enacted.
- Any sign constructed of non-durable material including, but not limited to, paper, cardboard, fabric, or flexible plastic. This provision does not apply to flags, awning signs, or banners which are otherwise allowed by this chapter.
- Portable signs, except authorized sandwich board signs.
- Signs attached to, painted on, or otherwise positioned in or on any vehicle or truck that is located in view of the street right-of-way when in a location or for a period of time that indicates that the use of the vehicle is for displaying the sign to passing motorists or pedestrians, except that such signs are allowed on a temporary basis in association with a temporary event permit.
- Signs located on any substandard lot created after the enactment of this chapter unless the substandard lot is created as the result of governmental action.
- Abandoned signs in a non-residential zoning district, DT district, and NL district (defined as signs related to a use discontinued for six months, unless proof of continued use is provided to the director).
- Any sign that is structurally unsound or is a hazard to traffic or pedestrians.
- Dilapidated or neglected signs (i.e., signs not maintained, with broken parts, rust, flaking paint, missing letters, etc.).
- Window shades used as signs.
- Illegal signs.
Exempt Signs in Tucker
- Signs erected by a public officer in the performance of their duties, including but not limited to: public notices, safety signs, danger signs, official traffic control devices, memorial plaques, and historical markers.
- Flags (subject to flagpole and size requirements in section 34-53(2)).
- Window signs that do not exceed 30 percent of the window area and other stated limitations.
- One internally illuminated window sign stating 'open' and/or 'closed' per establishment, not exceeding three square feet and included in the 30 percent window sign area limitation.
- Neon window signs meeting applicable area and separation requirements.
- Certain residential district signs as specified (with area, height, and illumination restrictions).
- One suspended sign per tenant or dwelling unit when under six square feet per side.
- Street number signs and other signs required by law.
- Nongovernmental traffic control devices in or adjacent to parking areas and driveways and signs located at railroad crossings.
- Historic signs meeting detailed age, documentation, and approval requirements as specified in section 34-53(8).
Sign Plan & Submission Notes for Tucker
- On developments 30 acres or larger, the planning and zoning director may approve alternative sign materials when those materials are part of the development's overall design program. Applicants must submit evidence of the development's overall design program, which may include, but is not limited to, a master sign plan, architectural pattern book, renderings, or other items conveying the development's character and design to the director's satisfaction. (Sec. 34-76)
- Alternative compliance via master sign plan or similar documentation is only available for developments 30 acres or larger and does not permit prohibited materials or sign types as set forth in section 34-52. (Sec. 34-76)
- A variance for signs may be granted by the zoning board of appeals in specified cases meeting strict hardship criteria, but no variance may be granted to allow a prohibited sign or to increase the aggregate sign area permitted on a lot. (Sec. 34-75)