Questions? Call us at (262) 218-2915

Sign Regulations in Cascade, Idaho

Cascade, Idaho has specific sign regulations covering 12 sign types across 3 zoning districts. Regulated sign types include Ground-Mounted Sign, Portable Sign, Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 19, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Cascade, Idaho

Sample Sign Requirements in Cascade

Sign TypeMax HeightMax AreaSetback
Ground-Mounted Sign20 ft90 sq. ft. (may be doubled for multi-face signs)Must not project beyond a legal setback; not within 10 ft of other signs in right of way.
Wall SignNot listedMax total for all wall signs: 200 sq. ft. (no one sign over 90 sq. ft.)No projection over public property or beyond legal setback greater than allowed in Uniform Sign Code.
Roof SignMax 5 ft above the ridge line or parapet50 sq. ft. (may be doubled for multi-face signs)Not listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for CascadeFull Coverage

Sign Types Covered

12

  • Ground-Mounted Sign
  • Portable Sign
  • Wall Sign
  • Roof Sign
  • +2 more types

Zoning Districts

3

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions

Frequently Asked Questions

In Cascade, the height limit for Ground-Mounted Sign in the R-II Zone, R-III Zone, RC Zone, A Zone is 4 ft (Sec. 2-2-10(H)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Cascade require a permit. From the submission notes on this page: The Building Official may require the filing of plans or other pertinent information with a sign permit application where such information is necessary to ensure compliance with the ordinance. Run a code check for an exact address to see the permit requirements for that zone.

Cascade's sign code covers 12 sign types, including Ground-Mounted Sign, Portable Sign, Wall Sign, and Roof Sign. Most commercial signs need a permit. The ordinance lists 5 exemptions. One of them: Painting, repainting, or cleaning of an advertising structure, or the changing of the advertising copy or message thereon, does not require a permit unless a structural change is made. The full list is on this page.

This page doesn't list a single setback distance for signs in Cascade. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.

Rules in Cascade's sign ordinance that cover digital, changing, or flashing signs: A conditional use permit (public hearing required) is required for animated signs or other uses otherwise prohibited by the ordinance but permitted with conditions. Run a code check for an exact address to see the rules for that zone.

AI-Powered Research

Ready to Research Cascade Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Cascade, Idaho, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Cascade, Idaho Sign Rules at a Glance

Cascade, Idaho regulates 12 sign types across 3 zoning districts. Resident Nameplate Signs are capped at 3 sq ft (Sec. 2-2-2(G)). Most commercial signs in Cascade require a permit.

Detailed Sign Ordinance Requirements for Cascade, Idaho

Sign Rules by Zoning District in Cascade (3 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Commercial Zone (C), Industrial Zone (I)820 ftMax total for all wall signs: 200 sq. ft. (no one sign over 90 sq. ft.)Not listed
R-II Zone, R-III Zone, RC Zone, A Zone14 ft16 sq. ft. (may be doubled for multi-face signs)Not listed
General Regulations For All Zones56 ft for rigid material signs100 sq. ft. (general max). Rigid material: 16 sq. ft. and 6 ft height max, not fastened to ground. Wheeled (rigid) signs: 32 sq. ft. (may be doubled for multi-face signs)Not listed

Zone-by-Zone Sign Requirements in Cascade

Commercial Zone (C), Industrial Zone (I)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground-Mounted Sign20 ft90 sq. ft. (may be doubled for multi-face signs)Not listedMust not project beyond a legal setback; not within 10 ft of other signs in right of way.2 per street frontageOn private property, not within 10 ft of another sign within any street right of way; must maintain clear vision area for traffic/pedestrian safety; must not project beyond a legal setbackNot listedUnlock2-2-10 (A)-(G)
Wall SignNot listedMax total for all wall signs: 200 sq. ft. (no one sign over 90 sq. ft.)Not listedNo projection over public property or beyond legal setback greater than allowed in Uniform Sign Code.Not listedAttached to or erected against the wall of a building or structure, face parallel to wall, max 6 in from wallNot listedUnlock2-2-16 (A)-(E)
Roof SignMax 5 ft above the ridge line or parapet50 sq. ft. (may be doubled for multi-face signs)Not listedNot listedNot listedOn or above the roof or parapet, not to exceed 5 ft above.Not listedUnlock2-2-14 (A)-(D)
Marquee SignNot listed200 sq. ft. without conditional use permitNot listedNot listedNot listedOn, attached to, or constructed in a marqueeNot listedUnlock2-2-11 (A)-(B)
Projecting SignNot listed16 sq. ft. per faceNot listedProjection up to 3 ft or 1/3 sidewalk widthNot listedFastened at one end to edge of a wall; may project up to 3 ft or 1/3 the width of the sidewalk, whichever is lessNot listedUnlock2-2-13 (A)
Hanging SignNot listed16 sq. ft. per faceNot listedNot listedNot listedBoth outer edges attached to supporting structure above; must clear sidewalks by at least 7 ftNot listedUnlock2-2-13 (A)
Portable SignNot listedSandwich board: 16 sq. ft. per faceNot listedNot listed2 per lot frontageOn private property, where does not interfere with traffic visibilityNot listedUnlock2-2-12, 2-2-4(C)
Canopy SignNot listedNot listedNot listedNot listedNot listedPart of an awning/canopy over a door, window, entrance, or outdoor service areaNot listedUnlock2-2-9

R-II Zone, R-III Zone, RC Zone, A Zone

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground-Mounted Sign4 ft16 sq. ft. (may be doubled for multi-face signs)Not listedMust not project beyond a legal setback; not within 10 ft of other signs in right of way.2 per street frontageOn private property, not within 10 ft of another sign within any street right of way; must maintain clear vision area for traffic/pedestrian safety; must not project beyond a legal setbackNot listedUnlock2-2-10(H)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Temporary Sign6 ft for rigid material signs100 sq. ft. (general max). Rigid material: 16 sq. ft. and 6 ft height max, not fastened to ground. Wheeled (rigid) signs: 32 sq. ft. (may be doubled for multi-face signs)Not listedNot listedNot listedOn private property; cloth signs may project over public property/streets with permission and 20 ft min clearance; other temporary signs (not cloth) when 8 ft or more above ground may project max 6 in over public property.Not listedUnlock2-2-15 (A)-(E)
Portable SignNot listedSandwich board: 16 sq. ft. per face (Section 2-2-12)Not listedNot listed2 per lot frontageOn private property, where not interfering with traffic visibilityNot listedUnlock2-2-12, 2-2-4(C)
Animated SignNot listedNot listedNot listedNot listedNot listedNot listedNot listedUnlock2-2-6, 2-2-2-1
BeaconsNot listedNot listedNot listedNot listedNot listedNot listedNot listedUnlock2-2-8
Resident Nameplate SignNot listed3 sq. ft.Not listedNot listedNot listedNot listedNot listedUnlock2-2-2(G)

Run a code check for your exact address to get the zone that applies to your property, plus illumination rules, size formulas, and permit requirements for every sign type in Cascade with a free PermitPal account.

Run a free code check

Prohibited Signs in Cascade

  • A sign may be erected, placed, established, painted, created, or maintained in the City only in conformance with the standards, procedures, exemptions, and other requirements of this Chapter.
  • All signs not expressly permitted by this Chapter are prohibited.
  • It is unlawful for any person to erect, construct, enlarge, alter, repair, remove, convert or demolish, equip, use or maintain any sign or sign structure in this jurisdiction contrary to or in violation of any of the provisions of this Chapter.
  • No sign or sign structure shall be erected, constructed, altered, or maintained without a permit when one is required.
  • Beacons are not permitted.
  • Any nonconforming sign destroyed by fire, calamity, or general dilapidation to an extent of sixty percent (60%) may not be restored unless restored as a conforming sign.
  • A nonconforming sign abandoned or discontinued for six (6) months or more cannot be reestablished and must comply with the current ordinance.
  • Signs must not project over public property or beyond a legal setback except as permitted.
  • No combustible materials other than approved plastics shall be used in the construction of electric signs.

Exempt Signs in Cascade

  • The changing of the advertising copy or message on a painted or printed sign only; this does not apply to theater marquees, replaceable copy signs, or electric signs.
  • Painting, repainting, or cleaning of an advertising structure, or the changing of the advertising copy or message thereon, does not require a permit unless a structural change is made.
  • Temporary and portable signs do not require a sign permit.
  • Canopy signs do not require a sign permit.
  • Temporary signs such as banners, pennants, flags, or similar do not require sign permits.

Sign Plan & Submission Notes for Cascade

  • The Building Official may require the filing of plans or other pertinent information with a sign permit application where such information is necessary to ensure compliance with the ordinance.
  • A sign permit fee and a plan-checking fee shall be paid in accordance with the schedule established by the Council.
  • Application for a sign permit must be made in writing on forms furnished by the City Clerk and may require filing of plans or information as requested by the Building Official.
  • A conditional use permit (public hearing required) is required for animated signs or other uses otherwise prohibited by the ordinance but permitted with conditions.