Questions? Call us at (262) 218-2915

Sign Regulations in Herscher, Illinois

Herscher, Illinois has specific sign regulations covering 20 sign types across 5 zoning districts. Regulated sign types include Ground or Pole Sign, Ground or Pole Sign (Integrated Planned Business Development), Wall Sign (Front/Rear). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 19, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Herscher, Illinois

Sample Sign Requirements in Herscher

Sign TypeMax HeightMax AreaSetback
Parking Area Entrance/Exit Sign10 ft above average parking grade4 sq ft eachNot listed
For Sale or Lease Sign (General)Not listed16 sq ftNot listed
Name Plate (One- and Two-Family Dwellings)10 ft above ground2 sq ftNo closer than half the required setback distance to the street

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for HerscherFull Coverage

Sign Types Covered

20

  • Ground or Pole Sign
  • Ground or Pole Sign (Integrated Planned Business Development)
  • Wall Sign (Front/Rear)
  • Wall Sign (Side Wall)
  • +2 more types

Zoning Districts

5

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Frequently Asked Questions

In Herscher, the height limit for Ground or Pole Sign in the Commercial Districts is 20 ft above grade at sign base (Sec. 10-11-7-3.A). The height limit for Wall Sign (Front/Rear) in the Commercial Districts is 15 ft above curb OR max 4 ft above roof. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Herscher require a permit. From the submission notes on this page: All signs on a zoning lot in a commercial district shall conform to a homogenous signage system which has been submitted to the Village at the time of erection of the first sign on the lot. Run a code check for an exact address to see the permit requirements for that zone.

Herscher's sign code covers 20 sign types, including Ground or Pole Sign, Ground or Pole Sign (Integrated Planned Business Development), Wall Sign (Front/Rear), and Wall Sign (Side Wall). Most commercial signs need a permit. The ordinance lists 5 exemptions. One of them: Legal notices, except as provided in subsections A. and D. The full list is on this page.

This page doesn't list a single setback distance for signs in Herscher. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.

Herscher's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.

AI-Powered Research

Ready to Research Herscher Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Herscher, Illinois, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required ยท Get results in seconds

Herscher, Illinois Sign Rules at a Glance

Herscher, Illinois regulates 20 sign types across 5 zoning districts. Church Bulletin Signs in the Residential Districts are capped at 12 ft above ground and 48 sq ft (Sec. 10-11-7-2.B). Most commercial signs in Herscher require a permit.

Detailed Sign Ordinance Requirements for Herscher, Illinois

Sign Rules by Zoning District in Herscher (5 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones410 ft above average parking grade16 sq ftNot listed
Residential Districts512 ft above ground48 sq ftNot listed
Commercial Districts1120 ft above grade at sign base64 sq ft per face, max 128 sq ft totalNot listed
Industrial District620 ft above grade at sign base64 sq ft per face, max 128 sq ft totalNot listed
Agriculture Districts120 ft above grade at sign base32 sq ft per face, max 64 sq ft total (all faces)Not listed

Zone-by-Zone Sign Requirements in Herscher(sample of 3 of 5 zones)

Residential Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Name Plate (One- and Two-Family Dwellings)10 ft above ground2 sq ftNot listedNo closer than half the required setback distance to the street1 per dwelling unitOn dwellingNot listedUnlock10-11-7-2.A.1.a(1), b
Identification Sign (Multi-family/Other Buildings)10 ft above ground12 sq ftNot listedNo closer than half the required setback distance to the street1 per buildingOn buildingNot listedUnlock10-11-7-2.A.1.a(2), b
Construction/Remodeling Sign10 ft above ground32 sq ftNot listedNot listed1 per lot (2 on corner lot)On property under construction/remodelingNot listedUnlock10-11-7-2.A.1.a(3), b
For Sale or Rent Sign (Residential District)5 ft above ground9 sq ftNot listedNo closer than half the required setback distance to the street1 per lot (2 on corner lots)On lot for sale/rentNot listedUnlock10-11-7-2.A.2
Church Bulletin Sign12 ft above ground48 sq ftNot listedNo closer than half the required setback distance to the street1 per lot (2 on corner lots)On church or religious propertyNot listedUnlock10-11-7-2.B

Commercial Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground or Pole Sign20 ft above grade at sign base32 sq ft per face, max 64 sq ft total (all faces)Not listedNot listed1 per zoning lot (where there are 3 or more establishments)On lot; must be 50 ft from any other ground or pole sign; 1 per zoning lot for establishments in multi-tenant buildingsNot listedUnlock10-11-7-3.A
Ground or Pole Sign (Integrated Planned Business Development)20 ft above grade at sign base64 sq ft per face, max 128 sq ft totalNot listedNot listed1 per parcel <2.5 acresWithin zoning lot on which use pertainsNot listedUnlock10-11-7-3.B
Wall Sign (Front/Rear)15 ft above curb OR max 4 ft above roof64 sq ft or 20% of building faceNot listedNot listedNot listedFront or rear wall of principal buildingNot listedUnlock10-11-7-3.C.2,4,5,6
Wall Sign (Side Wall)15 ft above curb OR max 4 ft above roof64 sq ft or 20% of side wallNot listedNot listedNot listedSide wall of principal buildingNot listedUnlock10-11-7-3.C.2,4,5,6
Marquee/Canopy/Awning SignNot listedNot listedNot listedNot listedNot listedFlat affixed to marquee/canopy/awning; not beyond limits of the structureNot listedUnlock10-11-7-3.C.7
Business Identification SignNot listed64 sq ft or 20% of front faceNot listedNot listed1 per establishmentOne per individual business establishmentNot listedUnlock10-11-7-3.C.1
Accessory Sign (Automobile Service Station) - Engine Oil RackNot listedNot listedNot listedNot listed2 per islandOn or at ends of pump islandsNot listedUnlock10-11-7-3.D.1
Accessory Sign (Automobile Service Station) - Tire Rack7 ftNot listed6 ft lengthNot listed2 per service stationGasoline or tire service stationNot listedUnlock10-11-7-3.D.2

Industrial District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground or Pole Sign20 ft above grade at sign base32 sq ft per face, max 64 sq ft total (all faces)Not listedNot listedNot listedOn lotNot listedUnlock10-11-7-4.A and 10-11-7-3.A
Ground or Pole Sign (Integrated Planned Business Development)20 ft above grade at sign base64 sq ft per face, max 128 sq ft totalNot listedNot listed1 per parcel <2.5 acresWithin zoning lot on which use pertainsNot listedUnlock10-11-7-4.A and 10-11-7-3.B
Wall Sign (Front/Rear)15 ft above curb OR max 4 ft above roof64 sq ft or 20% of building faceNot listedNot listedNot listedFront or rear wall of principal buildingNot listedUnlock10-11-7-4.A and 10-11-7-3.C.2,4,5,6
Wall Sign (Side Wall)15 ft above curb OR max 4 ft above roof64 sq ft or 20% of side wallNot listedNot listedNot listedSide wall of principal buildingNot listedUnlock10-11-7-4.A and 10-11-7-3.C.2,4,5,6
Marquee/Canopy/Awning SignNot listedNot listedNot listedNot listedNot listedFlat affixed to marquee/canopy/awning; not beyond limits of the structureNot listedUnlock10-11-7-4.A and 10-11-7-3.C.7
Advertising Sign (Billboard)Not listedNot listedNot listedNot listedNot listedAs approved by special use permitNot listedUnlock10-11-7-4.B

PermitPal covers all 5 zoning districts in Herscher. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Herscher

  • No sign shall be permitted unless it is in compliance with the requirements of this Chapter and the requirements of the zoning district in which the sign is located.
  • No sign shall block any required accessway or window.
  • No sign shall be attached to a tree, utility pole or existing sign.
  • No handbill shall be attached to any structure unless it is part of a permitted sign.
  • No sign shall project beyond the property line into the public way, except for signs installed by public governmental agencies and except within the C-1 Traditional Downtown District.
  • No sign shall project beyond the property line into another property, unless proper easements or agreements are in place to allow this to occur.
  • No sign shall show toward or be directly visible from the adjacent residential district when residential and commercial zoning areas are adjacent.
  • Every sign, including those for which no permits or permit fees are required, shall be maintained in a safe, presentable and good structural material condition at all times.
  • No display sign or outdoor device shall be altered, rebuilt, enlarged, extended or relocated, except in conformity with the provisions of this Title.

Exempt Signs in Herscher

  • Memorial signs and tablet displays on private property, not exceeding six (6) square feet in area, except as provided in subsections A. and D.
  • Address numerals and signs not exceeding two (2) square feet in area and bearing the names of the occupants of the premises, except as provided in subsections A. and D.
  • Governmental flags, insignia and signs when not used for commercial purposes, except as provided in subsections A. and D.
  • Legal notices, except as provided in subsections A. and D.
  • Governmental traffic and parking signs, except as provided in subsections A. and D.

Sign Plan & Submission Notes for Herscher

  • All signs on a zoning lot in a commercial district shall conform to a homogenous signage system which has been submitted to the Village at the time of erection of the first sign on the lot.
  • When multiple signs will be appropriate for a zoning lot in a commercial district, all signs shall conform to a signage system which has been recorded with the Village Zoning Official prior to the erection of the first sign on each zoning lot.
  • Permits for signs that need to exceed the standards set forth in the Chapter shall be treated as a special use (special use permit required).
  • Advertising signs (billboards) require a special use permit.