Sign Regulations in Hinckley, Illinois
Hinckley, Illinois has specific sign regulations covering 26 sign types across 4 zoning districts. Regulated sign types include Ground Base or Monument Sign, Wall Sign, Pole Sign (35,001 to 100,000 sq ft building). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 8, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Hinckley, Illinois
Sample Sign Requirements in Hinckley
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Ground Base or Monument Sign | 6 feet total; base no more than 2 feet above grade | Not listed | Not listed |
| Wall Sign | Not listed | 500 sq ft (1 frontage); 800 sq ft (2 frontages); 1,000 sq ft (3+ frontages) | Not listed |
| Pole Sign (35,001 to 100,000 sq ft building) | 18 feet | 150 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
26
- Ground Base or Monument Sign
- Wall Sign
- Pole Sign (35,001 to 100,000 sq ft building)
- Pole Sign (100,001 to 500,000 sq ft building)
- +2 more types
Zoning Districts
4
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Hinckley
Other Cities in Illinois
Frequently Asked Questions
In Hinckley, the height limit for Pole Sign (500,001+ sq ft building) in the Business Districts (B-1, B-2, B-3), Industrial Districts (I-1, I-2, I-3) is 28 feet. Maximum sign heights range from 16 ft to 28 feet across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Hinckley require a permit. From the submission notes on this page: A permit application for any regulated sign must be accompanied by plans and specifications showing size, character, material, location, bracing, anchorage, support, means of attachment, and other structural characteristics. Run a code check for an exact address to see the permit requirements for that zone.
Hinckley's sign code covers 26 sign types, including Ground Base or Monument Sign, Wall Sign, Pole Sign (35,001 to 100,000 sq ft building), and Pole Sign (100,001 to 500,000 sq ft building). Most commercial signs need a permit. The ordinance lists 8 exemptions. One of them: Any sign of the United States, state, or municipal corporation. The full list is on this page.
This page doesn't list a single setback distance for signs in Hinckley. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Rules in Hinckley's sign ordinance that cover digital, changing, or flashing signs: Flashing signs (illuminated signs with flashing lights or creating an illusion of movement), except for time and temperature information or scrolling light message subject to limitations, are prohibited. Signs located completely within an enclosed building unless affixed to a window, except that regulations on flashing and moving signs apply if visible from public property. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Hinckley Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Hinckley, Illinois, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Hinckley, Illinois Sign Rules at a Glance
Hinckley, Illinois regulates 26 sign types across 4 zoning districts. Temporary Subdivision Advertising Signs (Onsite) are capped at 16 ft tall and 32 ft wide (Sec. 18-140(3)). Most commercial signs in Hinckley require a permit.
Detailed Sign Ordinance Requirements for Hinckley, Illinois
Sign Rules by Zoning District in Hinckley (4 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Business Districts (B-1, B-2, B-3), Industrial Districts (I-1, I-2, I-3) | 10 | 28 feet | 500 sq ft (1 frontage); 800 sq ft (2 frontages); 1,000 sq ft (3+ frontages) | Not listed |
| Residential Districts | 5 | Not listed | 5 sq ft | Not listed |
| Manufacturing Districts | 10 | 28 feet | 500 sq ft (1 frontage); 800 sq ft (2 frontages); 1,000 sq ft (3+ frontages) | Not listed |
| General Regulations For All Zones | 12 | 16 ft | Total of all signs not to exceed 100 sq ft per zoning lot. | Not listed |
Zone-by-Zone Sign Requirements in Hinckley(sample of 3 of 4 zones)
Business Districts (B-1, B-2, B-3), Industrial Districts (I-1, I-2, I-3)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Ground Base or Monument Sign | 6 feet total; base no more than 2 feet above grade | Not listed | Not listed | Not listed | Not listed | On private property; not projecting into a public right-of-way | Not listed | Unlock | Sec. 18-135(a); Sec. 18-138(1),(4); Sec. 18-150 |
| Wall Sign | Not listed | 500 sq ft (1 frontage); 800 sq ft (2 frontages); 1,000 sq ft (3+ frontages) | Not listed | Not listed | Aggregate area limits cover all signs for the building; allocation among tenants is negotiable. | Attached/applied to exterior front, rear, or side wall of building. | Not listed | Unlock | Sec. 18-135(a)(2); Sec. 18-138(1),(2),(3); Sec. 18-150 |
| Pole Sign (35,001 to 100,000 sq ft building) | 18 feet | 150 sq ft | Not listed | Not listed | 1 per arterial/collector street frontage (integrated centers only) | On private property, not projecting into public right-of-way. | Not listed | Unlock | Sec. 18-135(a)(3); Sec. 18-138(4,6); Table 1 |
| Pole Sign (100,001 to 500,000 sq ft building) | 23 feet | 200 sq ft | Not listed | Not listed | 1 per arterial/collector street frontage (integrated centers only) | On private property, not projecting into public right-of-way. | Not listed | Unlock | Sec. 18-135(a)(3); Sec. 18-138(4,6); Table 1 |
| Pole Sign (500,001+ sq ft building) | 28 feet | 250 sq ft | Not listed | Not listed | 1 per arterial/collector street frontage (integrated centers only) | On private property, not projecting into public right-of-way. | Not listed | Unlock | Sec. 18-135(a)(3); Sec. 18-138(4,6); Table 1 |
| Window Sign | Not listed | Not listed | Not listed | Not listed | Not listed | On inside of window. | Not listed | Unlock | Sec. 18-135(a)(7); Sec. 18-132; Sec. 18-135(a)(3) |
| Fixed Canopy/Awning Sign | Not listed | Not listed | Not listed | Not listed | Not listed | Affixed to building, can project over sidewalk (lowest part min. 9 ft above grade). | Not listed | Unlock | Sec. 18-135(a)(5)(6); Sec. 18-138(5); Sec. 18-142(b) |
| Temporary Signs (General) | Not listed | Not listed | Not listed | Not listed | Per subsection, varies by sign type (real estate, political, architect-contractor, produce). | See specific type: e.g. real estate, contractor, produce, political signs. | Not listed | Unlock | Sec. 18-135(a)(4); Sec. 18-139 |
Manufacturing Districts
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Ground Base or Monument Sign | 6 feet total; base no more than 2 feet above grade | Not listed | Not listed | Not listed | Not listed | On private property; not projecting into a public right-of-way | Not listed | Unlock | Sec. 18-135(a); Table 1; Sec. 18-138(1), (4); Sec. 18-150 |
| Wall Sign | Not listed | 500 sq ft (1 frontage); 800 sq ft (2 frontages); 1,000 sq ft (3+ frontages) | Not listed | Not listed | Aggregate area limits cover all signs for the building; allocation among tenants is negotiable. | Attached/applied to exterior front, rear, or side wall of building. | Not listed | Unlock | Sec. 18-135(a)(2); Sec. 18-138(1),(2),(3); Sec. 18-150 |
| Pole Sign (35,001 to 100,000 sq ft building) | 18 feet | 150 sq ft | Not listed | Not listed | 1 per arterial/collector street frontage (integrated centers only) | On private property, not projecting into public right-of-way. | Not listed | Unlock | Sec. 18-135(a)(3); Sec. 18-138(4,6); Table 1 |
| Pole Sign (100,001 to 500,000 sq ft building) | 23 feet | 200 sq ft | Not listed | Not listed | 1 per arterial/collector street frontage (integrated centers only) | On private property, not projecting into public right-of-way. | Not listed | Unlock | Sec. 18-135(a)(3); Sec. 18-138(4,6); Table 1 |
| Pole Sign (500,001+ sq ft building) | 28 feet | 250 sq ft | Not listed | Not listed | 1 per arterial/collector street frontage (integrated centers only) | On private property, not projecting into public right-of-way. | Not listed | Unlock | Sec. 18-135(a)(3); Sec. 18-138(4,6); Table 1 |
| Window Sign | Not listed | Not listed | Not listed | Not listed | Not listed | On inside of window. | Not listed | Unlock | Sec. 18-135(a)(7); Sec. 18-132; Sec. 18-135(a)(3) |
| Fixed Canopy/Awning Sign | Not listed | Not listed | Not listed | Not listed | Not listed | Affixed to building, can project over sidewalk (lowest part min. 9 ft above grade). | Not listed | Unlock | Sec. 18-135(a)(5)(6); Sec. 18-138(5); Sec. 18-142(b) |
| Temporary Signs (General) | Not listed | Not listed | Not listed | Not listed | Per subsection, varies by sign type (real estate, political, architect-contractor, produce). | See specific type: e.g. real estate, contractor, produce, political signs. | Not listed | Unlock | Sec. 18-135(a)(4); Sec. 18-139 |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Real Estate Sign (Temporary) | Not listed | 10 sq ft per sign; on corner lots, one such sign may face each street. | Not listed | Not listed | 1 (2 on corner lots) | On private property (not in right-of-way). | Not listed | Unlock | Sec. 18-139(1) |
| Architect-Contractor Sign (Temporary, Residential) | Not listed | 10 sq ft | Not listed | Not listed | 1 | On premises where work is in progress. | Not listed | Unlock | Sec. 18-139(2) |
| Architect-Contractor Sign (Temporary, Business/Manufacturing) | Not listed | 20 sq ft | Not listed | Minimum 8 feet from property line or one-half the distance between property and building line, whichever is less. | 1 per street frontage | On premises where work is in progress. | Not listed | Unlock | Sec. 18-139(2) |
| Political Sign (Temporary) | Not listed | Total of all signs not to exceed 100 sq ft per zoning lot. | Not listed | Not listed | Aggregate 100 sq ft per zoning lot | Not permitted in right-of-way. | Not listed | Unlock | Sec. 18-139(4) |
| Agricultural Produce Sign (Temporary) | Not listed | 10 sq ft per sign | Not listed | Not listed | Maximum 2 per premises | On private property of resident where produce grown. | Not listed | Unlock | Sec. 18-139(5) |
| Temporary Subdivision Advertising Sign (Onsite) | 16 ft | Not listed | 32 ft | Not listed | 1 per arterial route frontage | Onsite, for subdivision until 95% of lots sold. | Not listed | Unlock | Sec. 18-140(3) |
| Temporary Subdivision Advertising Sign (Off-site) | 10 ft | Not listed | 12 ft | Not listed | 1 per subdivision per arterial route | Private property fronting arterial route. | Not listed | Unlock | Sec. 18-140(4) |
| Temporary Subdivision Advertising Sign (Public Right-of-Way) | 2 ft | Not listed | 2 ft | Not listed | 3 per land being developed | Arterial route right-of-way. | Not listed | Unlock | Sec. 18-140(5) |
PermitPal covers all 4 zoning districts in Hinckley. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Hinckley
- It is unlawful to display any sign in violation of this article.
- Any sign type not specifically listed as a permitted sign is expressly prohibited unless determined otherwise by the village president or designee.
- Signs on fences or on walls not part of a building or structure are prohibited.
- Flashing signs (illuminated signs with flashing lights or creating an illusion of movement), except for time and temperature information or scrolling light message subject to limitations, are prohibited.
- Signs within 300 feet of any traffic control signal shall not have illumination of red, green, or amber color.
- Billboards and poster boards are prohibited.
- No sign, retractable canopy, or awning may be erected, relocated, or maintained so as to prevent free ingress to or egress from any door, window, or fire escape; nor attached to a standpipe or fire escape.
- No sign, retractable canopy, or awning may be erected or maintained so as to obstruct free and clear vision or distract the attention of drivers.
- No sign, retractable canopy, or awning within 300 feet of an intersection shall make use of the words 'stop,' 'go,' 'look,' 'slow,' 'danger,' or similar words, phrases, symbols, or characters, or colored lamps/lights that could mislead or confuse traffic.
- On corner lots, within a triangular area of 25 feet from the intersection of street rights-of-way, no sign more than 30 inches above the crown of the road is allowed.
- Any sign advertising a business no longer conducted or a product no longer sold shall be removed within 30 days of notice.
- Any sign is deemed a public nuisance if displayed in violation of this article or found to be a hazard to health or safety.
- Signs not conforming to building, electrical, and structural codes are prohibited.
- No sign shall be maintained in a dilapidated, unsafe, or nonconforming condition.
- No permit shall be issued if the sign constitutes a hazard to traffic or the public by reason of obstruction of view, distraction, or endangering safety.
Exempt Signs in Hinckley
- Any sign of the United States, state, or municipal corporation.
- The flag, emblem, or insignia of a nation, governmental unit, school, or religious group.
- Signs located completely within an enclosed building unless affixed to a window, except that regulations on flashing and moving signs apply if visible from public property.
- Paper signs affixed to the interior of a window for less than 30 days.
- Identification and addresses of establishments on awnings or marquees.
- Street or house number signs not exceeding 1.5 square feet in area.
- Directional or instructional signs conveying directions or instructions for safety or convenience, or necessary for operation of premises, not exceeding 3 square feet in area.
- A barber pole or similar symbol or device used in connection with a barber shop.
Sign Plan & Submission Notes for Hinckley
- A permit application for any regulated sign must be accompanied by plans and specifications showing size, character, material, location, bracing, anchorage, support, means of attachment, and other structural characteristics.
- The village may require sketches, drawings, or photographs for sign variance applications to indicate the present and intended condition of property or sign.
- Permanent signs, except for exempted categories, require permit issuance following review of plans for conformance with the ordinance.
- For variations to sign requirements, sketches, drawings or photographs shall be required as necessary by the zoning board of appeals or the village board.
Source: municode municipal code