Sign Regulations in Inverness, Illinois
Inverness, Illinois has specific sign regulations covering 11 sign types across 2 zoning districts. Regulated sign types include Exempt Temporary Sign, Subdivision/Neighborhood Entrance Monument, Nameplate. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 19, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Inverness, Illinois
Sample Sign Requirements in Inverness
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Exempt Temporary Sign | 6 feet above grade | 6 square feet per side (up to 2 sides) | At least 30 feet from the edge of pavement. |
| Subdivision/Neighborhood Entrance Monument | 6.5 feet above the centerline datum elevation of the highest street upon which the sign faces | 125 square feet per side | Not listed |
| Nameplate | Not listed | 1 square foot | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
11
- Exempt Temporary Sign
- Subdivision/Neighborhood Entrance Monument
- Nameplate
- No Trespassing/No Dumping Sign
- +2 more types
Zoning Districts
2
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Other Cities in Illinois
Frequently Asked Questions
In Inverness, the height limit for Ground Sign is 20 feet above centerline datum elevation of street upon which sign faces. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Inverness require a permit. From the submission notes on this page: Applications for permits must include blueprints or ink drawings of plans, specifications, and methods of construction and attachment. Run a code check for an exact address to see the permit requirements for that zone.
Inverness's sign code covers 11 sign types, including Exempt Temporary Sign, Subdivision/Neighborhood Entrance Monument, Nameplate, and No Trespassing/No Dumping Sign. Most commercial signs need a permit. The ordinance lists 9 exemptions. One of them: Change of letters or the message on a sign with a changeable copy panel and repainting of existing signs do not require a permit. The full list is on this page.
In Inverness, Exempt Temporary Sign in the A-1 Residential Zoning District, Residential Zoning Districts must be set back at least 30 feet from the edge of pavement (Sec. 5-5-12A). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Inverness's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.
Ready to Research Inverness Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Inverness, Illinois, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Inverness, Illinois Sign Rules at a Glance
Inverness, Illinois regulates 11 sign types across 2 zoning districts. Exempt Temporary Signs in the A-1 Residential Zoning District, Residential Zoning Districts are capped at 6 feet above grade, set back at least 30 feet from the edge of pavement (Sec. 5-5-12A). Most commercial signs in Inverness require a permit.
Detailed Sign Ordinance Requirements for Inverness, Illinois
Sign Rules by Zoning District in Inverness (2 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| A-1 Residential Zoning District, Residential Zoning Districts | 7 | 6.5 feet above the centerline datum elevation of the highest street upon which the sign faces | 125 square feet per side | Not listed |
| General Regulations For All Zones | 4 | 20 feet above centerline datum elevation of street upon which sign faces | Maximums as stated per lot frontage in formula; maximum per face is 100 sq ft. | Not listed |
Zone-by-Zone Sign Requirements in Inverness
A-1 Residential Zoning District, Residential Zoning Districts
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Exempt Temporary Sign | 6 feet above grade | 6 square feet per side (up to 2 sides) | Not listed | At least 30 feet from the edge of pavement. | 1 per lot (except political signs, no number limit) | At least 30 feet from the edge of the pavement of any adjacent street; private property only. | Not listed | Unlock | 5-5-12A |
| Subdivision/Neighborhood Entrance Monument | 6.5 feet above the centerline datum elevation of the highest street upon which the sign faces | 125 square feet per side | Not listed | Not listed | Not listed | At subdivision, neighborhood, or village entrance, not in public area without a permit and Board approval. | Not listed | Unlock | 5-5-12C |
| Nameplate | Not listed | 1 square foot | Not listed | Not listed | Not listed | On private property only | Not listed | Unlock | 5-5-12B(4) |
| No Trespassing/No Dumping Sign | Not listed | 2 square feet | Not listed | Not listed | 1 per 50 feet of lot boundary/frontage | On private property only. | Not listed | Unlock | 5-5-12B(5) |
| Memorial Sign or Building Name/Date Marker | Not listed | Not listed | Not listed | Not listed | Not listed | Cut into masonry surface or constructed of bronze or other noncombustible materials. | Not listed | Unlock | 5-5-12B(2) |
| Governmental Sign | Not listed | Not listed | Not listed | Not listed | Not listed | As necessary for governmental purposes. | Not listed | Unlock | 5-5-12B(3) |
| Sign Regulating Traffic (Private Property) | Not listed | Not listed | Not listed | Not listed | Not listed | Private property. | Not listed | Unlock | 5-5-12B(7) |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Ground Sign | 20 feet above centerline datum elevation of street upon which sign faces | Maximums as stated per lot frontage in formula; maximum per face is 100 sq ft. | Not listed | Not nearer the street than the building line. Not within 6 feet of any other sign/building/structure on adjacent premises. | 1 per lot/parcel; 2 permitted if frontage is 350+ ft, spaced 250 ft apart | Not nearer the street than the building line; not within 8 feet of electric power lines, and not within 6 feet of any other sign, building, or structure on adjoining premises. Not allowed in residential zoning districts, except exemptions in 5-5-12. | Not listed | Unlock | 5-5-20, 5-5-21, 5-5-11 |
| Wall Sign | Must not protrude or extend above the lowest point of the roof; mansard roof rules apply. | 25% of wall area or maximum area allowed for ground sign (see formula) | Not listed | Not listed | Max 1 per wall; 1 per wall of corner lot; 1 per business occupant on same building (5-5-24). | On building wall, not to cover or project beyond ends or top of the wall. | Not listed | Unlock | 5-5-23, 5-5-25, 5-5-11, 5-5-13O |
| Canopy/Awning with Advertising | Lowest part of frame: 7'6" over public area; lowest extending skirt: 6'8" above grade. | Not listed | Not listed | Not closer than 18 inches to curb. | Not listed | Over public area or with advertising; not closer than 18" to curb of any adjacent street. | Not listed | Unlock | 5-5-28 |
| Clock with Advertising | Not listed | Dial not more than 42 inches in diameter | Not listed | Not listed | Not listed | On exterior of building, not less than 7.5 feet above sidewalk; may not project more than 12 inches from face of building; not allowed on public area. | Not listed | Unlock | 5-5-29 |
Run a code check for your exact address to get the zone that applies to your property, plus illumination rules, size formulas, and permit requirements for every sign type in Inverness with a free PermitPal account.
Run a free code checkProhibited Signs in Inverness
- It is unlawful to erect, construct, repair, alter, relocate, change, or maintain any sign without first securing a sign permit and paying the appropriate fee.
- It is unlawful to violate, disobey, omit, neglect, refuse to comply with, or resist or obstruct enforcement of any provision of the sign ordinance.
- No sign shall be erected or maintained so as to constitute a traffic hazard, obstruct free and clear vision, distract attention of drivers, interfere with or be confused with traffic signs, or cause glare on public areas or residential property.
- No sign shall use words or symbols such as 'stop', 'go', 'look', 'slow', 'danger', or similar, or use colored lights that may mislead or confuse traffic.
- No sign constructed on or at any public area or within five feet thereof shall have hazardous projections, except electrical reflectors/devices.
- No sign over a public area shall be wholly or partially illuminated by floodlights or spotlights.
- All signs must be painted at erection and at least every 2 years thereafter, unless constructed of noncorrosive or treated material.
- All signs must be designed and constructed to withstand wind pressure of at least 30 pounds per square foot and must meet load requirements.
- Glass on any sign must be safety glass of at least 1/4 inch thickness.
- No sign shall be erected, relocated or maintained to obstruct ingress or egress from any door, window, or fire escape, or be attached to a standpipe or fire escape.
- No sign shall cover wholly or partially any opening, or project beyond the ends or top of the wall to which it is attached.
- No sign shall be located within any public area except certain governmental/traffic signs or monuments as specified.
- No sign shall be located in such a manner as to interfere with visibility for drivers using any public area.
- The following signs are prohibited: marquees, projecting signs, roof signs, temporary signs (except as specifically allowed), flashing signs, moving signs, tethered airborne signs or balloons, beacon lights, portable signs, freestanding signs, poster boards, bench signs, billboards, internally illuminated signs, streamers, banners, pennants, valances, signs not advertising a bona fide business or product sold on the property, signs painted directly on walls and vehicle signs, any sign(s) located within any public area (except governmental/traffic and approved monuments as specified).
- No pennants, banners, or streamers are permitted in the village.
- No temporary signs are permitted except as expressly allowed.
- No person shall suspend or place goods, wares, or merchandise on the exterior of any building as a sign.
- It is unlawful to display obscene, indecent, or immoral matter on any sign.
- Projections of canopies/awnings over public areas must meet clearance and size requirements.
- No clocks shall be erected on any public area.
- No advertising, except for the owner's/business name, is allowed on canopies, awnings, or clocks.
Exempt Signs in Inverness
- Change of letters or the message on a sign with a changeable copy panel and repainting of existing signs do not require a permit.
- Flags, emblems, or insignia of any nation, political subdivision, or corporate flag (except when used for commercial promotion) are exempt.
- Memorial signs or tablets, names of buildings, and date of erection cut into masonry or constructed of bronze/noncombustible materials are exempt.
- Governmental signs such as traffic control signs, legal notices, identification signs for government buildings/facilities/departments, informational/warning/enforcement/directional/railroad crossing/temporary emergency signs, and other non-advertising signs as approved by the village board are exempt.
- Nameplates on private property not exceeding one square foot are exempt.
- "No Trespassing" and/or "No Dumping" signs up to 2 square feet, posted only on private property with a limit of one per 50 feet of boundary or frontage, are exempt.
- Integral decorative or architectural building features, except with letters, trademarks, moving parts/lights, are exempt.
- Signs regulating traffic and parking on private property with no advertising content are exempt.
- Temporary signs for construction, community events, garage/rummage sales, real estate for sale/for rent/open house, and political signs are exempt provided they comply with listed size, height, location, and removal regulations. (Note: Not permitted in public area unless governmental or traffic signs; must not be illuminated; max size and height; limit one per lot except political; removal within timeline; no banners/balloons/pennants/streamers/related prohibited displays attached.)
Sign Plan & Submission Notes for Inverness
- Applications for permits must include blueprints or ink drawings of plans, specifications, and methods of construction and attachment.
- If required by the building inspector due to size, location, or safety, stress sheets and calculations for structural integrity must be submitted.
- An electrical permit is required if electrical elements are involved.
- Evidence of insurance must be provided for signs extending over or that could topple onto public streets.
- Applications for subdivision, neighborhood, or village entrance monuments must be submitted with scaled renderings, specifications for illumination, location survey, and materials. Approval by the Board of Trustees is required (and possibly referral to the Plan Commission).
- Subdivision, neighborhood, or village entrance monuments on public areas require express approval of the Board of Trustees by motion or resolution.