Sign Regulations in Lake Barrington, Illinois

Lake Barrington, Illinois has specific sign regulations covering 12 sign types across 4 zoning districts. Regulated sign types include Temporary Sign, Ground/Monument Sign, Permanent Ground/Monument Sign (Association Property). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 20, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Lake Barrington, Illinois

Sample Sign Requirements in Lake Barrington

Sign TypeMax HeightMax AreaSetback
Temporary Sign6 feet16 square feet (single sign); 48 square feet (association property)Not listed
Permanent Ground/Monument Sign (Association Property)8 feet48 square feetNot listed
Ground/Monument Sign12 feet100 square feet (max per sign)Min 3 ft from right-of-way; min 6 ft from adjacent sign/building

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Lake BarringtonFull Coverage

Sign Types Covered

12

  • Temporary Sign
  • Ground/Monument Sign
  • Permanent Ground/Monument Sign (Association Property)
  • Permanent Directional/Wayfinding/Traffic Sign (Association Property)
  • +2 more types

Zoning Districts

4

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Frequently Asked Questions

In Lake Barrington, the height limit for Ground/Monument Sign in the Business District (B), Manufacturing District (M), Office District (O) is 12 feet (Sec. 8-9-7.B). The height limit for Temporary Banner/Flag (Wall-Mounted) in the Business District (B), Manufacturing District (M), Office District (O) is 8 feet (Sec. 8-9-5.D2). Maximum sign heights range from 8 feet to 12 feet across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Lake Barrington require a permit. From the submission notes on this page: A Master Sign Plan is required for uses involving a building larger than 5,000 square feet of ground floor area, any nonresidential development on sites of 5 acres or larger, or any nonresidential development with 4 or more nonresidential occupants. Run a code check for an exact address to see the permit requirements for that zone.

Lake Barrington's sign code covers 12 sign types, including Temporary Sign, Ground/Monument Sign, Permanent Ground/Monument Sign (Association Property), and Permanent Directional/Wayfinding/Traffic Sign (Association Property). Most commercial signs need a permit. The ordinance lists 8 exemptions. One of them: Municipal signs as defined by the ordinance. The full list is on this page.

In Lake Barrington, Ground/Monument Sign in the Business District (B), Manufacturing District (M), Office District (O) must be set back at least 3 ft from right-of-way (Sec. 8-9-7.B). The ordinance adds other placement rules for this sign type, listed in the table on this page. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Lake Barrington's sign ordinance that cover digital, changing, or flashing signs: Special use permit is required for digital signs, digital displays, and moving and spinning signs (not allowed in residential districts). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Lake Barrington Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Lake Barrington, Illinois, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Lake Barrington, Illinois Sign Rules at a Glance

Lake Barrington, Illinois regulates 12 sign types across 4 zoning districts. Permanent Ground/Monument Signs (Association Property) in the Residential District (R-1, R-2, R-5) are capped at 8 feet tall and 48 square feet (Sec. 8-9-7.C). Most commercial signs in Lake Barrington require a permit.

Detailed Sign Ordinance Requirements for Lake Barrington, Illinois

Sign Rules by Zoning District in Lake Barrington (4 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential District (R-1, R-2, R-5)38 feet48 square feetNot listed
Business District (B), Manufacturing District (M), Office District (O)812 feet100 square feet (max per sign)Not listed
Conservation District (C)2Not listedNot listedNot listed
General Regulations For All Zones1Not listedNot listedNot listed

Zone-by-Zone Sign Requirements in Lake Barrington(sample of 3 of 4 zones)

Residential District (R-1, R-2, R-5)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Temporary Sign6 feet16 square feet (single sign); 48 square feet (association property)Not listedNot listedMax 3 signs (if each is ≤ 6 sq ft); larger temporary sign (≤16 or 48 sq ft) – see aggregate limitsOn private propertyNot listedUnlock8-9-4.C
Permanent Ground/Monument Sign (Association Property)8 feet48 square feetNot listedNot listedNot listedOn property owned by residential condo or homeowners' associationNot listedUnlock8-9-7.C
Permanent Directional/Wayfinding/Traffic Sign (Association Property)Not listedNot listedNot listedNot listedNot listedOn property owned by residential condo or homeowners' associationNot listedUnlock8-9-7.C

Business District (B), Manufacturing District (M), Office District (O)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground/Monument Sign12 feet100 square feet (max per sign)Not listedMin 3 ft from right-of-way; min 6 ft from adjacent sign/building1 per lot, 2 if frontage ≥350 ft and separated as aboveOn private lot, not in right-of-wayNot listedUnlock8-9-7.B
Wall SignNot to extend above lowest point of roofUp to 100 square feet but only if ground sign max for property allows; else proportionateNot listedNot listed1 per wall (up to 2 for corner/multi-frontage lots); one per occupant entityOn building facade, not over public right-of-wayNot listedUnlock8-9-7.D
Temporary Banner/Flag (Freestanding)8 feet10 square feet per signNot listedNot listedMax 2On private lot, must comply with locations rulesNot listedUnlock8-9-5.D1
Temporary Banner/Flag (Wall-Mounted)8 feet10 square feet per signNot listedNot listedMax 1Affixed to wall, must comply with locations rulesNot listedUnlock8-9-5.D2
Sandwich Board Sign (Temporary)8 feet10 square feet per signNot listedNot listedMax 1On private lot, must comply with locations rulesNot listedUnlock8-9-5.D3
Window SignNot listed25% of the window or door areaNot listedNot listedNot listedOn exterior surface of window or glass doorNot listedUnlock8-9-7.F
Awning/Canopy SignNot listedPerimeter outline considered as area (counts as wall sign area)2 feet from each side of entranceNot listedNot listedOver entrance but not over public right-of-wayNot listedUnlock8-9-7.H
Digital Sign (Special Use Only)Not listedNot listedNot listedNot listedNot listedNot listedNot listedUnlock8-9-7.G

Conservation District (C)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Temporary SignNot listedNot listedNot listedNot listedNot listedOn private propertyNot listedUnlock8-9-1.C.3.c
Ground/Monument SignNot listedNot listedNot listedNot listedNot listedOn private propertyNot listedUnlock8-9-1.C.3.c

PermitPal covers all 4 zoning districts in Lake Barrington. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Lake Barrington

  • No signs, other than municipal signs, are permitted on any public property or within any public right-of-way.
  • No sign shall be erected or maintained in a manner that obstructs free and clear vision or distracts the attention of drivers, bicyclists, or pedestrians.
  • No sign shall interfere with, obstruct, or be confused with any authorized traffic sign, signal, or device, or cause glare on any public area or residential property.
  • No sign shall use words like 'Stop', 'Go', 'Look', 'Slow', 'Danger', or similar, nor employ colored lights or lamps that might mislead or confuse traffic.
  • No sign shall interfere with safe sight lines of drivers, bicyclists, or pedestrians using public right-of-way or public property.
  • Any sign for a use, occupancy, or product no longer existing must be removed within thirty (30) days of written notification.
  • Illegal and nonconforming signs must be removed or brought into compliance within ten (10) days of notice, unless a permit application, appeal, or variation is pending.
  • If a sign is unsafe, unsecure, a danger, or violates code, it must be corrected or removed within thirty (30) days of notification, or immediately if an imminent peril.
  • Signs are only allowed on the property of the sign owner or with property owner's consent.
  • No freestanding sign may use overhead electrical lines; only underground supply is permitted.
  • No nonconforming sign may be changed to another nonconforming sign, except for nonstructural replacement of letters, panels, or symbols.
  • Prohibited sign types in all zoning districts: roof signs (with exceptions for certain mansard roofs), billboards or off-site signage unless expressly permitted, vehicle signs, tethered airborne signs and balloons, beacons, inflatables, signs on trailers and other portable signs.
  • No temporary or permanent sign, whether exempt or non-exempt, shall block any wall opening, door, window, or fire escape, nor be attached to a standpipe or fire escape.
  • No sign shall be erected or maintained so as to interfere with snow removal.
  • No sign shall be erected or maintained so as to prevent free ingress or egress from doors, windows or fire escapes, nor wholly or partially cover wall openings.

Exempt Signs in Lake Barrington

  • Municipal signs as defined by the ordinance.
  • Permanent or temporary signs located on private property (with owner's consent) that do not exceed 6 square feet in display surface area (maximum of 3 such signs per zoning lot or parcel).
  • Change of letters, words, and/or symbols on changeable copy panels and normal repairs/repainting of existing signs.
  • Flags less than 15 square feet in surface area.
  • Integral decorative or architectural features of buildings, including clocks.
  • Signs or displays visible from outside through a window but not affixed/attached to or blocking such window.
  • Temporary signs in residential zoning districts (other than B, M, or O districts) meeting all of the following: single sign not exceeding 16 square feet, aggregate not exceeding 32 square feet (48 for homeowner/condo associations), height not over 6 feet, not illuminated, not interfering with traffic safety.
  • Traffic control signs, digital/electronic signs for traffic, municipal wayfinding signs, directional signs, traffic signals/devices, legal notices, railroad crossing signs, danger signs, temporary emergency and event signs, public utility signs, and similar are permitted in every district and are exempt from these sign regulations.

Sign Plan & Submission Notes for Lake Barrington

  • A Master Sign Plan is required for uses involving a building larger than 5,000 square feet of ground floor area, any nonresidential development on sites of 5 acres or larger, or any nonresidential development with 4 or more nonresidential occupants.
  • A Master Sign Plan, if approved, must be approved in the same manner as other variation(s) and/or special use permit(s): public hearing before the Plan Commission, recommendation to Board of Trustees, approval by ordinance.
  • Wall signs, ground signs, wayfinding, directional, and other non-specified signs are required to be included in Master Sign Plans.
  • Variations from sign regulations and/or special use permits require a public hearing before the Plan Commission and approval by the Board of Trustees by ordinance.
  • Special use permit is required for digital signs, digital displays, and moving and spinning signs (not allowed in residential districts).