Nevada, Iowa has specific sign regulations covering 39 sign types across 11 zoning districts. Regulated sign types include Flag Sign, Projecting Sign, Detached Ground Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: January 9, 2026

Sign Regulation Overview for Nevada, Iowa

Sample Sign Requirements in Nevada

Sign TypeMax HeightMax AreaSetback
Residential Detached Sign25 ft structure height limit for detached signs (Table 165.20-4)2 sq ft for residential uses, including home occupations (Table 165.20-3 Note 1)Front: 25 ft; Side: 10 ft (Table 165.20-4).
Residential Attached Wall SignIncluded within 2 sq ft maximum for all residential signs on a premises (Table 165.20-3 Note 1).If building is on front property line and wall sign encroaches over ROW, must maintain 8 ft 6 in clearance and max 18 in encroachment (165.20(3)(A)(4)).
Residential Projecting SignWithin overall 2 sq ft maximum for residential uses (Table 165.20-3 Note 1).May project max 18 in into required setback or ROW (165.20(3)(B)(1)); must also respect vision-clearance triangle (165.20(2)(F)).

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for NevadaFull Coverage

Sign Types Covered

39

  • Flag Sign
  • Projecting Sign
  • Detached Ground Sign
  • Pole Sign
  • +2 more types

Zoning Districts

11

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Nevada

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

Sign height limits in Nevada vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Nevada, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Nevada, regulated sign types include Flag Sign, Projecting Sign, Detached Ground Sign, Pole Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Nevada vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Nevada are regulated with specific requirements for brightness, animation, and message duration. Nevada has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Nevada Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Nevada, Iowa sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Nevada, Iowa Sign Rules at a Glance

Nevada, Iowa regulates 39 sign types across 11 zoning districts. Detached Ground Signs in the Mixed Use Urban Corridor District (UC), Community Commercial District (CC) zoning district are capped at 25 ft maximum height (Table 165.20-4). tall and 200 sq ft per premises maximum for all signs (Table 165.20-3: UC, CC row), plus one business center identification sign of 150 sq ft where applicable (Note 5). Individual detached sign max: 200 sq ft (Table 165.20-4)., with a Front 10 ft; Side 5 ft (Table 165.20-4). Must remain out of vision-clearance triangle (165.20(2)(F)). setback (Sec. Table 165.20-1; Table 165.20-2; Table 165.20-3 (UC, CC row & Note 5); Table 165.20-4; 165.20(2)(C)(7); 165.20(10); Table 165.09-2 note re 165.16(6)(A),(B)). Most commercial signs in Nevada require a permit.

Detailed Sign Ordinance Requirements for Nevada, Iowa

Sign Rules by Zoning District in Nevada (11 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Agricultural/Residential Reserve District (AR)825 ft structure height limit for detached signs (Table 165.20-4)Up to 200 sq ft total for civic or commercial uses on a premises in AR (Table 165.20-3 Note 1: 200 sq ft for civic or commercial uses). Individual detached sign maximum size "x" and thus constrained by this 200 sq ft premise maximum (Table 165.20-4).
Rural Residential District (RR), Low Density Single-Family Residential District (R-1)710 ft detached structure height limit in RR/R-1 (Table 165.20-4).32 sq ft max for project identification signs and 32 sq ft for civic uses in RR/R-1 (Table 165.20-3 Note 2).
Medium Density Single and Two-Family Residential District (R-2), Urban Family Residential District (R-3), Multiple-Family Residential District (R-4), Mobile Home Residential District (R-5)710 ft for detached signs (Table 165.20-4).Counts toward attached-sign and overall sign-area limits, including 75 sq ft and 20% façade rule (Table 165.20-4; 165.20(3)(A)(6)).
Mixed Use Urban Corridor District (UC), Community Commercial District (CC)1225 ft maximum height (Table 165.20-4).200 sq ft per premises maximum for all signs (Table 165.20-3: UC, CC row), plus one business center identification sign of 150 sq ft where applicable (Note 5). Individual detached sign max: 200 sq ft (Table 165.20-4).
Limited Commercial/Office District (LC)1220 ft structure height (Table 165.20-4, LC column).200 sq ft max for all signs on non-residential premises (Table 165.20-3). On primary residential premises within LC, 32 sq ft for project identification for multi-family developments and 2 sq ft for residential uses (Note 4).
Downtown Commercial District (DC)1125 ft max height (Table 165.20-4).200 sq ft maximum per detached sign and per premises for all signs (Table 165.20-3 DC row: 200 sq ft max total; Table 165.20-4: 200 sq ft max size).
General Commercial District (GC)945 ft max height (Table 165.20-4 GC column).Per detached sign: 200 sq ft; premises total: 200 sq ft, plus 150 sq ft business center sign where applicable (Table 165.20-3, Table 165.20-4, Note 5).
Business Park District (BP), Limited Industrial District (LI), General Industrial District (GI)9BP: 20 ft; LI/GI: 45 ft (Table 165.20-4).Per detached sign: 200 sq ft (Table 165.20-4). Premises total: 200 sq ft plus 150 sq ft business center sign where applicable (Table 165.20-3 Note 5).
Conservation and Open Space District (COS)3The ordinance does not assign COS a row in Table 165.20-3. In practice, project identification for parks/open space is typically treated under civic-use notes (200 sq ft for civic/commercial uses in AR-like situations or 32 sq ft for civic uses in RR/R-1/R-2/R-3/R-4/R-5). Here, apply conservative interpretation: 32 sq ft civic sign as in Notes 2–3 for other low-intensity districts.
General Regulations For All Zones4
Mixed Use Urban Corridor District (UC)1325 ft (Table 165.20-4, UC, CC column).Per detached sign: 200 sq ft (Table 165.20-4, UC/CC column). Premises total for all signs: 200 sq ft (Table 165.20-3, “UC, CC” row, Maximum Total Square Feet 200).

Zone-by-Zone Sign Requirements in Nevada(sample of 3 of 11 zones)

Mixed Use Urban Corridor District (UC), Community Commercial District (CC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Detached Ground Sign25 ft maximum height (Table 165.20-4).200 sq ft per premises maximum for all signs (Table 165.20-3: UC, CC row), plus one business center identification sign of 150 sq ft where applicable (Note 5). Individual detached sign max: 200 sq ft (Table 165.20-4).Front 10 ft; Side 5 ft (Table 165.20-4). Must remain out of vision-clearance triangle (165.20(2)(F)).1 detached sign per premises (Table 165.20-4). In addition, 1 detached center identification sign allowed for business centers under Note 1 of Table 165.20-4.Detached on-premises; Ground signs P in UC and CC (Table 165.20-1). Front setback 10 ft; side setback 5 ft (Table 165.20-4).UnlockTable 165.20-1; Table 165.20-2; Table 165.20-3 (UC, CC row & Note 5); Table 165.20-4; 165.20(2)(C)(7); 165.20(10); Table 165.09-2 note re 165.16(6)(A),(B)
Pole Sign25 ft (Table 165.20-4).200 sq ft maximum per pole sign (Table 165.20-4).Same as detached: Front 10 ft; Side 5 ft (Table 165.20-4).Same detached limits: 1 pole/ground sign per premises; plus 1 business center ID sign if criteria met.On-premises; Pole P in UC, CC (Table 165.20-1).UnlockTable 165.20-1; Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(3)(C); 165.20(10)
Attached Wall SignUp to 200 sq ft per premises total for all signs (Table 165.20-3). Per attached sign: up to 200 sq ft, but no more than 20% of street façade (Table 165.20-4, UC, CC column).If attached to building on front property line and encroaching over ROW, max 18 in encroachment and min 8'6" clearance (165.20(3)(A)(4)).No fixed numeric limit; constrained by total area and façade-percentage limits.On building wall; Wall P in UC, CC (Table 165.20-1).UnlockTable 165.20-1; Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(3)(A),(D); 165.20(10)
Awning SignCounted as wall signs toward 200 sq ft premises cap and 20% façade limit (165.20(3)(A)(6); Table 165.20-3; Table 165.20-4).Any encroachment over ROW controlled by wall/projection rules.Limited by attached-sign area caps.On awnings attached to exterior walls; Awning Signs P in UC, CC (Table 165.20-1).UnlockTable 165.20-1; 165.20(1)(D); 165.20(3)(A)(6); Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(10)
Banner (Building-Mounted)Maximum banner size is lesser of twice permitted size of a projecting sign or 120 sq ft (165.20(4)(C)(3)). Projecting signs are allowed in UC but N in CC (Table 165.20-1). For CC, banner limit defaults to 120 sq ft because projecting signs are not permitted; ordinance still caps banners at 120 sq ft regardless.Must maintain 10 ft clearance and max 5 ft projection (165.20(4)(C)(2)); must not violate vision-clearance at driveways/intersections.No specific numeric limit per premises; constrained by total sign area and temporary sign limits when used temporarily.Attached and projecting from building; Banner P in UC, CC (Table 165.20-1).UnlockTable 165.20-1; 165.20(4)(C); 165.20(2)(E)(2)(c); Table 165.20-2; 165.20(10)
Canopy SignCounted as wall signs toward 200 sq ft and façade-percentage caps (165.20(3)(A)(6); Table 165.20-3).Must maintain required clearances over sidewalks/streets analogous to projecting/marquee signs.Limited by attached-sign caps.Attached to or integral with canopy; Canopy Signs P in UC and CC (Table 165.20-1).UnlockTable 165.20-1; 165.20(1)(H),(I); 165.20(3)(A)(6); 165.20(4)(B); Table 165.20-2; Table 165.20-3; 165.20(10)
Directional Detached Sign25 ft in UC, CC (Table 165.20-4).Counts toward 200 sq ft total and 1.5 sq ft/ft frontage limits (Table 165.20-3).Front 10 ft; Side 5 ft (Table 165.20-4).Counts toward 1 detached sign per premises cap; additional if used as business center ID sign under Note 1 of Table 165.20-4.Detached directional signs P in UC, CC (Table 165.20-1).UnlockTable 165.20-1; Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(1)(L); 165.20(2)(F),(C)(7); 165.20(10)
Roof Sign – IntegralMay not exceed permitted height for pole signs (25 ft in UC/CC) (165.20(3)(D)(2); Table 165.20-4).Counts as wall sign toward 200 sq ft premises cap and attached/facade limits (165.20(3)(D)(1); Table 165.20-3; Table 165.20-4).Must respect overall building height and sign height as measured from grade (165.20(5)(C)).Limited by wall/attached-area caps.On roof; Integral Roof P in UC and CC (Table 165.20-1).UnlockTable 165.20-1; 165.20(1)(CC); 165.20(3)(D); Table 165.20-3; Table 165.20-4; 165.20(10)

Limited Commercial/Office District (LC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Detached Ground Sign20 ft structure height (Table 165.20-4, LC column).200 sq ft max for all signs on non-residential premises (Table 165.20-3). On primary residential premises within LC, 32 sq ft for project identification for multi-family developments and 2 sq ft for residential uses (Note 4).Front 10 ft; Side 10 ft (Table 165.20-4, LC column).1 detached sign per premises (Table 165.20-4); plus 1 business center ID sign where criteria met (Notes 1,5).Ground signs P in LC (Table 165.20-1). Detached sign front and side setbacks 10 ft (Table 165.20-4).UnlockTable 165.20-1; Table 165.20-2; Table 165.20-3 (LC row and Note 4); Table 165.20-4; 165.20(2)(C)(7); 165.20(10); Table 165.09-2 note
Pole Sign20 ft (Table 165.20-4).200 sq ft max per pole sign (Table 165.20-4).0 – not permitted.Pole signs N in LC (Table 165.20-1); therefore not allowed.UnlockTable 165.20-1 (Pole N in LC)
Attached Wall SignPer attached sign: 75 sq ft (Table 165.20-4, LC column).If encroaching over ROW, must meet wall-sign encroachment and clearance limits (165.20(3)(A)(4)).No numeric limit; constrained by 75 sq ft per attached sign, 20% façade, and 200 sq ft premises cap.On building wall; Wall P in LC (Table 165.20-1).UnlockTable 165.20-1; Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(3)(A); 165.20(10)
Awning SignCounts toward attached-sign and premises caps (75 sq ft / 20% façade / 200 sq ft) (Table 165.20-4; Table 165.20-3; 165.20(3)(A)(6)).If projecting, must preserve safe clearances akin to projecting signs.Limited by attached caps.On awnings; Awning Signs P in LC (Table 165.20-1).UnlockTable 165.20-1; 165.20(3)(A)(6); Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(10)
BannerMax 120 sq ft or twice permitted projecting sign area, whichever is less (165.20(4)(C)(3)). Projecting signs are P in LC, so banner cap is 2×projecting cap but not over 120 sq ft.5 ft projection limit, 10 ft minimum clearance (165.20(4)(C)(2)); cannot infringe vision-clearance.No explicit numeric limit; subject to premises sign-area caps and temporary sign limits when applicable.Building-mounted; Banner P in LC (Table 165.20-1).UnlockTable 165.20-1; 165.20(4)(C); 165.20(2)(E)(2)(c); Table 165.20-2; 165.20(10)
Canopy SignCounts as wall sign; within 75 sq ft and 20% façade per sign, 200 sq ft per premises (165.20(3)(A)(6); Table 165.20-3; Table 165.20-4).Must maintain clearance over sidewalks and not encroach excessively into ROW.Limited by attached sign caps.On canopy; Canopy Signs P in LC (Table 165.20-1).UnlockTable 165.20-1; 165.20(1)(H),(I); 165.20(3)(A)(6); Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(4)(B); 165.20(10)
Business Identification (Attached)Within attached 75 sq ft per sign and 200 sq ft premises cap, 20% façade limit (Table 165.20-3; Table 165.20-4).Same as wall signs.Limited by area caps.On building; Business Identification P in LC (Table 165.20-1).UnlockTable 165.20-1; Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(10)
Projecting SignCounts toward attached 75 sq ft and 20% façade caps and 200 sq ft premises cap (Table 165.20-3; Table 165.20-4).Max 18 in projection into setback/ROW (165.20(3)(B)(1)); must avoid vision-clearance triangle (165.20(2)(F)).Limited by area caps.On building; Projecting P in LC (Table 165.20-1).UnlockTable 165.20-1; 165.20(3)(B); Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(10)

Mixed Use Urban Corridor District (UC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Detached Ground Sign25 ft (Table 165.20-4, UC, CC column).Per detached sign: 200 sq ft (Table 165.20-4, UC/CC column). Premises total for all signs: 200 sq ft (Table 165.20-3, “UC, CC” row, Maximum Total Square Feet 200).Front 10 ft; Side 5 ft (Table 165.20-4). Must also comply with 40 ft vision-clearance triangle (165.20(2)(F)).Base detached: “Per premises” = NA in UC/CC column and “Per feet of frontage” = 1 per 200 ft (Table 165.20-4). So 1 detached sign per 200 ft of frontage. One additional Business Center Identification Sign allowed per business center (Note 1 to Table 165.20-4; Note 5 to Table 165.20-3).On-premises, detached; Ground signs P in UC (Table 165.20-1). Front yard setback 10 ft; side yard setback 5 ft (Table 165.20-4, UC/CC column).UnlockTable 165.20-1 (Ground P in UC); Table 165.20-3 (UC, CC row & Note 5); Table 165.20-4 (UC, CC detached row); Table 165.20-2; 165.20(2)(C)(7); 165.20(10); Table 165.09-2 note 165.16(6)(A),(B); Note 1 Table 165.20-4
Pole Sign25 ft (Table 165.20-4, UC, CC column).200 sq ft per pole sign (shares detached 200 sq ft max – Table 165.20-4).Same as other detached signs: front 10 ft; side 5 ft (Table 165.20-4) and vision-clearance rules (165.20(2)(F)).1 pole/ground sign per 200 ft of frontage, plus 1 business center ID sign if applicable (Table 165.20-4; Note 1).On-premises; Pole signs P in UC (Table 165.20-1).UnlockTable 165.20-1 (Pole P in UC); 165.20(3)(C); Table 165.20-2; Table 165.20-4; 165.20(10); 165.20(2)(C)(7)
Attached Wall SignPer attached sign: 200 sq ft (Table 165.20-4 UC/CC column). Premises total all signs: 200 sq ft (Table 165.20-3).If building is on front property line and wall sign encroaches over ROW: max 18 in encroachment; min 8'6" clearance (165.20(3)(A)(4)).No fixed numeric limit; constrained by 200 sq ft premises cap and 20% façade limit per sign.On building wall; Wall signs P in UC (Table 165.20-1).UnlockTable 165.20-1; Table 165.20-3; Table 165.20-4; Table 165.20-2; 165.20(3)(A),(D); 165.20(10)
Awning SignCounts toward wall/attached sign caps: 200 sq ft per sign, 20% façade, 200 sq ft premises total (165.20(3)(A)(6); Tables 165.20-3 and 165.20-4).If projecting over sidewalk/ROW, must provide safe clearance comparable to projecting signs; also must not violate 40 ft vision-clearance triangle.Limited by wall/area caps.On awnings attached to building; Awning Signs P in UC (Table 165.20-1).UnlockTable 165.20-1; 165.20(1)(D); 165.20(3)(A)(6); Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(10)
Banner (Building-Mounted)Max banner size = lesser of (2 × permitted projecting sign size) or 120 sq ft (165.20(4)(C)(3)). Projecting signs are P in UC, so banner cap is 2×projecting sign limit but never over 120 sq ft.Must maintain 10 ft clearance and max 5 ft projection; cannot obstruct traffic visibility (165.20(4)(C)(2); 165.20(2)(F)).No explicit numeric cap; constrained by area caps and temporary-sign rules when applicable.Projecting from buildings; Banner P in UC (Table 165.20-1).UnlockTable 165.20-1; 165.20(4)(C); 165.20(2)(E)(2); Table 165.20-2; 165.20(10)
Canopy SignCounts as wall sign towards 200 sq ft per sign, 20% façade, 200 sq ft premises cap (165.20(3)(A)(6); Table 165.20-3; Table 165.20-4).Must maintain projecting-sign clearances where extending over sidewalk/ROW; avoid vision-clearance areas.Limited by wall/area caps.On canopies; Canopy Signs P in UC (Table 165.20-1).UnlockTable 165.20-1; 165.20(1)(H),(I); 165.20(3)(A)(6); 165.20(4)(B); Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(10)
Roof Sign – IntegralMay not exceed permitted height for pole signs (25 ft in UC) (165.20(3)(D)(2); Table 165.20-4).Counts as wall sign within attached/wall and premises caps (165.20(3)(D)(1); Table 165.20-3; Table 165.20-4).Height measured from average grade (165.20(5)(C)); must fit any building-height limits for UC in Table 165.09-3.Limited by wall/area caps.On roof; Roof, Integral P in UC (Table 165.20-1).UnlockTable 165.20-1; 165.20(1)(CC); 165.20(3)(D); Table 165.20-3; Table 165.20-4; 165.20(10)
Detached Directional Sign25 ft (Table 165.20-4 UC/CC detached).Counts toward 200 sq ft premises cap and 1.5 sq ft/ft frontage (Table 165.20-3).Front 10 ft; side 5 ft; maintain vision-clearance triangle (Table 165.20-4; 165.20(2)(F)).Included within 1 detached sign per 200 ft frontage; plus business center ID sign if applicable.Detached on-premises; Directional P in UC (Table 165.20-1).UnlockTable 165.20-1; 165.20(1)(L); Table 165.20-2; Table 165.20-3; Table 165.20-4; 165.20(2)(C),(F),(10)

PermitPal covers all 11 zoning districts in Nevada — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 11 zones for Nevada — start free

Prohibited Signs in Nevada

  • Each sign or part of a sign erected within the zoning jurisdiction of the City must comply with the provisions of the sign section and other relevant provisions of the Code of Ordinances and relevant State building codes; where regulations conflict, the more restrictive regulations apply.
  • Signs or sign structures which resemble or conflict with traffic control signs or devices, which mislead or confuse persons traveling on public streets, or which create a traffic hazard are prohibited in all zoning districts.
  • Signs on or overhanging public property or public right-of-way are prohibited in all zoning districts, except as specifically provided for temporary flag banners authorized over Lincoln Highway at Sixth Street under subsection 165.20(2)(E)(2)(c).
  • Signs which create a safety hazard by obstructing the clear view of pedestrians or vehicles, or which obscure official signs or signals, are prohibited in all zoning districts.
  • Abandoned signs are prohibited in all zoning districts; any abandoned sign must be removed within six months of the date of abandonment, including removal of abandoned structural components.
  • Signs that are not clean or in substantial good repair, or are not affixed to a sound structure, are prohibited in all zoning districts.
  • Signs advertising activities that are illegal under Federal, State or local laws and regulations are prohibited in all zoning districts.
  • Off‑premises signs advertising events or commercial products or services for sale are prohibited in all zoning districts unless, in the case of an electronic sign, the owner has applied for and received a valid permit to operate and maintain such off‑premises electronic sign.
  • No sign may project into or be placed within a vision‑clearance area defined by a triangle with legs of forty feet from the point at which the right‑of‑way lines of two intersecting streets, private ways, or courts, or an intersecting street, private way, or court and driveway, meet.
  • Lighting used to illuminate a sign must be positioned so that light is not directed onto an adjoining property or onto a public street or highway.
  • Projecting signs may not expose guy wires, cables, turnbuckles, angle iron, or other similar external support structure.
  • Permitted pole signs may revolve only at a rate not to exceed six revolutions per minute.
  • Temporary or portable signs for grand openings, sales and special events at commercial and industrial premises may be present at any single premises for a maximum of 30 days per year and are limited to one such sign per premises and to the size limitations in Table 165.20‑3.
  • Temporary signs for non‑profit civic campaigns or events, or other non‑commercial events, must be installed no earlier than 30 days before the date of the event or election and removed no later than 7 days after; they are subject to maximum size limits of 6 square feet in residential and LC districts and 32 square feet in other districts.
  • Temporary flag banners over Lincoln Highway at Sixth Street must comply with all conditions in 165.20(2)(E)(2)(c), including permit, location, liability and insurance requirements; none of these conditions may be waived.
  • A wall sign attached to a building on its front property line may encroach upon public right‑of‑way by no more than 18 inches and must provide minimum clearance of eight feet, six inches; other wall signs must comply with the general limitations on projection and location.
  • No projecting sign may project more than 18 inches into a public right‑of‑way or required setback, except in the Downtown Commercial District where special projection limits apply; projecting signs must maintain specified minimum clearances over sidewalks, parking areas, lots, alleys and driveways.
  • Pole signs must maintain specified minimum clearances over sidewalks, parking areas, lots, alleys and driveways, and within 50 feet of street intersections.
  • Roof signs must comply with limitations that integral roof signs may be used only where permitted, may not exceed the permitted height for pole signs, and must be mounted parallel to the wall of the building that they face.
  • Banners projecting from a building may not exceed the wall height of the building, may project a maximum of five feet with a minimum clearance of ten feet, and may not exceed the lesser of twice the permitted size of a projecting sign or 120 square feet.
  • For all sign types and districts, maximum permitted sign area and number, height, setback, illumination type, and auxiliary design elements are limited as specified in Tables 165.20‑1 through 165.20‑4 and must not be exceeded.

Exempt Signs in Nevada

  • Bulletin boards for religious assembly or school uses, provided they have a maximum sign area of 20 square feet and are not located in a required sign setback, are permitted in any zoning district and are exempt from other provisions of the sign section.
  • Real estate sales or management signs with an area of less than 6 square feet are permitted in any zoning district and are exempt from other provisions of the sign section.
  • Official signs authorized by a government or governmental subdivision which give traffic, directional or warning information are permitted in any zoning district and are exempt from other provisions of the sign section.
  • Seasonal decorations for display on private or public property are permitted in any zoning district and are exempt from other provisions of the sign section.
  • On‑premises construction signs with a maximum sign area of 6 square feet in residential districts and 32 square feet in other districts, provided they are removed within one week after completion of the construction project to which they refer, are permitted in any zoning district and are exempt from other provisions of the sign section.
  • One temporary sign per zoned lot for grand openings or special events, provided that such sign remains in place for a maximum of seven days, is permitted in any zoning district and is exempt from other provisions of the sign section.
  • Works of graphic art painted or applied to building walls which contain no advertising or business identification messages are permitted in any zoning district and are exempt from other provisions of the sign section.
  • Residential signs under 2 square feet in size are permitted in any zoning district and are exempt from other provisions of the sign section.
  • Street numbers are permitted in any zoning district and are exempt from other provisions of the sign section.
  • Signs which are not visible from a public right‑of‑way, private way or court, or from a property other than that on which the sign is installed, are permitted in any zoning district and are exempt from other provisions of the sign section.
  • Temporary signs for non‑profit civic campaigns or events, or other non‑commercial events, complying with the timing and size limits in 165.20(2)(E)(2), are permitted in any zoning district and are exempt from other provisions of the sign section.

Sign Plan & Submission Notes for Nevada

  • Temporary flag banners over Lincoln Highway at Sixth Street require a Temporary Permit obtained by submitting an Application to the Planning and Zoning Commission that includes detailed information on the event, sponsor, banner size and message, building‑owner permissions, liability acceptance and indemnification, and proof of insurance coverage; the Planning and Zoning Commission acts on this application as a condition of allowing the banner.
  • Any installation, modification, or expansion of any sign that is not exempt must obtain a sign permit before installation, through application to the Building Official, including payment of required fees, review and action within ten working days, and compliance with expiration, assignment, and maintenance‑of‑permit requirements.
  • Off‑premises electronic signs advertising events or commercial products or services for sale are only allowed if the owner has applied for and received a valid permit to operate and maintain such off‑premises sign.
  • Business center identification signs (center identification signs) are allowed only subject to additional conditions in Note 1 to Table 165.20‑4, including spacing from other center identification and detached signs and content limitations; these conditions effectively function as a site‑level sign plan constraint for business centers.

Source: amlegal municipal code