Sign Regulations in Lexington, Kentucky

Lexington, Kentucky has specific sign regulations covering 152 sign types across 19 zoning districts. Regulated sign types include Wall Sign - Residence, Bulletin Board - Religious/Educational, All Signs - General Requirements. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: November 24, 2025

Sign Regulation Overview for Lexington, Kentucky

Sample Sign Requirements in Lexington

Sign TypeMax HeightMax AreaSetback
All Signs - General RequirementsAs applicable per sign type and zone; general prohibition on encroachment into right-of-way unless explicitly allowed.
Incidental Sign≤ 2 sq ft
Limited Duration Sign (Agricultural/Residential uses)≤ 6 ft≤ 6 sq ft

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for LexingtonFull Coverage

Sign Types Covered

152

  • Wall Sign - Residence
  • Bulletin Board - Religious/Educational
  • All Signs - General Requirements
  • Exempt Sign - Not legible beyond property boundaries
  • +2 more types

Zoning Districts

19

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Lexington

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

Sign height limits in Lexington vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Lexington, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Lexington, regulated sign types include Wall Sign - Residence, Bulletin Board - Religious/Educational, All Signs - General Requirements, Exempt Sign - Not legible beyond property boundaries, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Lexington vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Lexington are regulated with specific requirements for brightness, animation, and message duration. Lexington has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Lexington Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Lexington, Kentucky sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Lexington, Kentucky Sign Rules at a Glance

Lexington, Kentucky regulates 152 sign types across 19 zoning districts. Freestanding Sign - Per Buildings in the Professional Office Zone (P-1), Mixed Use 1: Neighborhood Node Zone (MU-1) zoning district are capped at ≤ 10 ft tall and ≤ 40 sq ft, with a Minimum 10 ft setback (Sec. Sec. 17-11(e)(1)). Most commercial signs in Lexington require a permit.

Detailed Sign Ordinance Requirements for Lexington, Kentucky

Sign Rules by Zoning District in Lexington (19 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones14≤ 10 ft≤ 32 sq ft (up to 64 sq ft if building ≥100,000 sq ft or site ≥2 acres)
Agricultural Zones (A-R, A-U, A-B, A-N)9Freestanding: ≤ 10 ft≤ 32 sq ft
Mobile Home Park Zone (M-1P)2≤ 8 ft≤ 32 sq ft
Low Density Residential Zones (R-1 [A—E], R-1T, R-2)9≤ 8 ft (if freestanding)≤ 32 sq ft
Planned Neighborhood Residential, Medium Density Residential & High Density Residential Zones (R-3, R-4, R-5), Expansion Area Residential (EAR-1, EAR-2, EAR-3)7Additional wall sign mounted at minimum height of 75 ft≤ 32 sq ft
Professional Office Zone (P-1), Mixed Use 1: Neighborhood Node Zone (MU-1)16≤ 20 ft (collector/arterial frontage) or ≤ 15 ft (collector/arterial & local intersection)≤ 150 sq ft (collector/arterial frontage) or ≤ 75 sq ft (collector/arterial & local intersection)
Neighborhood Business Zone (B-1)14Freestanding: ≤ 20 ft≤ 50 sq ft per sign
Corridor Business, Corridor Node, Warehouse/Wholesale, and Industrial Zones (B-3, CN, B-4, I-1, I-2)13≤ 40 ft (freestanding billboard general cap); specific freestanding billboard height cap 40 ft≤ 400 sq ft
Downtown Business Zones (B-2, B-2A)15Located < 50 ft on building≤ 80 sq ft
Lexington Center Business Zone (B-2B)7≤ 48 inchesTwo signs ≤ 200 sq ft each; Two signs ≤ 50 sq ft each; One sign ≤ 800 sq ft
Interchange Service Business Zone (B-5P)7≤ 90 ft; minimum height 75 ft≤ 356 sq ft
Commercial Center Zone (B-6P)8≤ 30 ft≤ 150 sq ft per sign face
Planned Unit Development Zones (PUD)1As determined by underlying zoneAs determined by sign requirements of the zone in which the proposed or existing use is first permitted
University Research Campus Zone (P-2)5Freestanding ≤ 10 ft (except hospital campus regs); others per P-1≤ 50 sq ft (non-rigid); ≤ 32 sq ft (rigid)
Mixed Use 2: Neighborhood Corridor Zone (MU-2)11≤ 10 ft≤ 75 sq ft per sign
Mixed Use 3: Mixed-Use Community Zone (MU-3)8≤ 48 inchesPrimary: ≤ 150 sq ft per sign; Secondary: ≤ 40 sq ft per sign
Conservation District (CD)1
Community Center (CC) Zone3Freestanding: ≤ 20 ftPer B-1 allowances
Economic Development (ED) Zone4≤ 90 ft; minimum 75 ft≤ 356 sq ft

Zone-by-Zone Sign Requirements in Lexington(sample of 3 of 19 zones)

Professional Office Zone (P-1), Mixed Use 1: Neighborhood Node Zone (MU-1)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Sign - Per Building≤ 10 ft≤ 40 sq ftMinimum 10 ftOne per buildingOn lot; setback required.UnlockSec. 17-11(e)(1)
Wall Sign - Per Tenant/Lessee≤ 2 sq ftOne per tenant/lesseeOn tenant space.UnlockSec. 17-11(e)(5)
Traffic Directional Signs≤ 3 ft (if freestanding)≤ 2 per entranceAt entrances.UnlockSec. 17-11(e)(6)
Attraction BoardIncluded in maximum permitted sign areaOneOn building or attached to freestanding sign.UnlockSec. 17-11(e)(7)
Pole-Mounted Banner SignsMinimum vertical clearance 8 ftMax size 2 ft x 4 ft per bannerTotal limited by area of parking/plaza: 1 per 3,000 sq ftOn light fixtures in parking lots/pedestrian plazas outside the public right-of-way; may not encroach into right-of-way.UnlockSec. 17-11(e)(9)
Subdivision Entrance Sign (Professional Office Project)≤ 8 ft≤ 32 sq ftMax 2 per entranceMay be in right-of-way (median or each side) with authorization; must not be in sight triangle.UnlockSec. 17-11(e)(10)(c)
Hospital/Regional Medical Campus - Campus Signs (Collector/Arterial frontages)≤ 20 ft (collector/arterial frontage) or ≤ 15 ft (collector/arterial & local intersection)≤ 150 sq ft (collector/arterial frontage) or ≤ 75 sq ft (collector/arterial & local intersection)Max 3 per campusAlong streets classified as collector/arterial; at intersection of collector/arterial and local street.UnlockSec. 17-11(e)(11)(a)
Hospital/Regional Medical Campus - Subdivision Entrance Signs≤ 10 ft≤ 100 sq ftMax 2 per entrance; max 2 entrances identifiedAt campus entrances along collector/arterial streets.UnlockSec. 17-11(e)(11)(b)

Neighborhood Business Zone (B-1)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding or Wall Signs - General (B-1)Freestanding: ≤ 20 ftFreestanding minimum 10 ft from streetFreestanding: one per street frontage, max twoOn property; one freestanding sign per street frontage.UnlockSec. 17-11(f) (intro); (1)(a), (1)(b), (1)(d)-(f)
Freestanding Sign (B-1)≤ 20 ft≤ 50 sq ft per signMinimum 10 ftMax two; one per street frontageOn lot per street frontage.UnlockSec. 17-11(f)(1)(b)
Projecting Sign (Infill & Redevelopment Area; building ≤10 ft from front property line)≤ 12 ft≤ 50 sq ftOne projecting sign (replaces freestanding signs)On existing principal structure located ≤10 ft from front property line within defined Infill and Redevelopment Area.UnlockSec. 17-11(f)(1)(c)
Marquee - Indoor TheaterMinimum clearance 8 ft; projections ≤ 8 ft from building face≤ 24 sq ft per theaterOne marquee per theater (second allowed if no attraction board on freestanding sign)Attached to building serving indoor theater.UnlockSec. 17-11(f)(2)
Attraction Board (B-1)Included in max permitted sign areaOneOn wall or freestanding sign.UnlockSec. 17-11(f)(3)
Traffic Directional Signs (B-1)≤ 3 ft (if freestanding)≤ 3 sq ft≤ 2 per entranceAt entrances.UnlockSec. 17-11(f)(4)
Menu Board (B-1)≤ 8 ft (if freestanding)≤ 45 sq ftOne per restaurant use OR one per drive-through laneFree-standing near drive-thru or walk-up/drive-up service areas.UnlockSec. 17-11(f)(6); Sec. 17-18(cc)
Pole-Mounted Banner Signs (B-1)Minimum clearance 8 ftMax size 2 ft x 4 ft per bannerLimited by area of parking/plaza: 1 per 3,000 sq ftOn light fixtures in parking lots and pedestrian plazas outside public right-of-way; may not encroach into right-of-way.UnlockSec. 17-11(f)(8); Sec. 17-4(g)

Downtown Business Zones (B-2, B-2A)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Sign (B-2/B-2A)≤ 20 ft≤ 40 sq ftMax two; one per street frontageOn lot; may project into right-of-way up to 12 inches.UnlockSec. 17-11(h)(1)(a)
Wall Sign - Additional per building face (located <50 ft on building)Located < 50 ft on buildingLetter height/vertical cabinet dimension ≤ 2.5 ftOne additional per building faceOn building face.UnlockSec. 17-11(h)(1)(c)
Wall Sign - Per establishment (separate/direct entrance)Mounted between 10 ft and 30 ft high≤ 80 sq ftOne per street building face per establishmentOn building face for establishment with separate and direct entrance.UnlockSec. 17-11(h)(1)(d)
Projecting Sign (Per establishment with separate/direct entrance)Height limit of 30 ft as attached; minimum vertical clearance 10 ft≤ 50 sq ftOne per establishment per street building faceMounted on building of establishment.UnlockSec. 17-11(h)(1)(e); Sec. 17-8(d)
Wall Sign - Small Identification (per establishment with separate entrance)Located ≤ 10 ft high on building face≤ 5 sq ftOne per establishmentOn face of building.UnlockSec. 17-11(h)(2)
Traffic Directional Signs (B-2/B-2A)Per B-1: ≤ 3 ftPer B-1: ≤ 3 sq ft≤ 2 per entranceAt entrances.UnlockSec. 17-11(h)(3); Sec. 17-11(f)(4)
Menu Board/Menu Box (B-2/B-2A)Menu Board: ≤8 ft (if freestanding)Menu Board: ≤45 sq ft; Menu Box: ≤4 sq ftPer B-1 allowancesOn premises.UnlockSec. 17-11(h)(3); Sec. 17-11(f)(6)-(7)
A-Frame/Sandwich Board≤ 48 inches≤ 8 sq ft per panel≤ 24 inchesOne per street front; max twoOn sidewalk/pedestrian way; must allow 4 clear feet of sidewalk width; not over curb line; not restricting egress from parked cars.UnlockSec. 17-11(h)(6); Sec. 17-18(a)

PermitPal covers all 19 zoning districts in Lexington — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 19 zones for Lexington — start free

Prohibited Signs in Lexington

  • Illuminated signs may not cast direct rays of light beyond the property lines of the lot on which the sign is located (Sec. 17-8(a)).
  • No light, sign, or advertising device may imitate or resemble any official traffic sign, signal, or device, or use words/phrases/symbols implying danger or the need to stop or maneuver a vehicle (Sec. 17-8(b)).
  • No sign may be attached to or painted on any tree, utility pole, or street light (Sec. 17-8(c)).
  • No sign, except government signs, may be located within the sight triangle of any intersection (Sec. 17-8(f)).
  • No sign may be placed in or project into the public or private street right-of-way, except where specifically permitted by this Article (Sec. 17-8(g)).
  • Mobile signs are prohibited (Sec. 17-9(a)).
  • Roof signs that extend higher than the top edge of the roof are prohibited (Sec. 17-9(b)).
  • Rotating or moving signs are prohibited (Sec. 17-9(c)).
  • Abandoned signs are prohibited (Sec. 17-9(d)).
  • Streamers, pennants, tag signs, or similar devices are prohibited except when attached to a permitted temporary sign (Sec. 17-9(e)).
  • Any sign which emits noise, odor, or visible matter is prohibited (Sec. 17-9(f)).
  • Free-standing signs that overhang any part of a building are prohibited (Sec. 17-9(g)).
  • Flashing or blinking signs are prohibited (Sec. 17-9(h)).
  • Any sign not specifically permitted by the ordinance is prohibited (Sec. 17-11, lead-in).

Exempt Signs in Lexington

  • Signs not legible beyond the boundaries of the property on which they are located and/or from any public thoroughfare or right-of-way are exempt from the provisions of this Article and from permitting (Sec. 17-3(a)).
  • Government signs placed by government officers in the performance of their duties are exempt from the provisions of this Article and from permitting (Sec. 17-3(b)).
  • Temporary or permanent signs erected by public utility companies or construction companies in the performance of their professional duties are exempt from the provisions of this Article and from permitting (Sec. 17-3(c)).
  • Vehicle signage painted directly on a vehicle or attached magnetically is exempt from the provisions of this Article and from permitting (Sec. 17-3(d)).
  • Incidental signs do not require a permit (may be subject to other provisions) (Sec. 17-4(a)).
  • Historic markers do not require a permit (may be subject to other provisions) (Sec. 17-4(b)).
  • Construction signs do not require a permit (may be subject to other provisions) (Sec. 17-4(c)).
  • Change of copy where the framework or structural elements are not altered does not require a permit (Sec. 17-4(d)).
  • Limited duration signs (one per street frontage; size/height and illumination limits based on property use) do not require a permit (Sec. 17-4(e)).
  • Window signs do not require a permit (may be subject to other provisions) (Sec. 17-4(f)).
  • Pole banners do not require a permit (may be subject to other provisions) (Sec. 17-4(g)).
  • Temporary signs related to events sponsored by neighborhood or owners' associations within the neighborhood right-of-way (subject to number, size, height, timing, and sight triangle limits) do not require a permit (Sec. 17-4(h)).

Sign Plan & Submission Notes for Lexington

  • A sign permit is required for any sign unless specifically exempt; applications must include a completed form, a site plan and/or building elevation showing sign location and setbacks, detailed sign construction/illumination/mounting information, owner consent, and the permit fee (Sec. 17-7).
  • Variances to signage dimensional requirements require a hearing before the Board of Adjustment; the Board may also approve transfers of unused signage square footage between the same signage type along the same street frontage; the Board may not increase the number of permitted signs, allow a sign type or feature not permitted in the zone, or increase the maximum total permitted sign area on a lot/building (Sec. 17-10).
  • Landmark and district identification signs require approval from the Commissioner of Environmental Quality & Public Works (or designee) and a four-member sign review committee; such signs must meet applicable Kentucky Building and Fire Safety Codes and are evaluated against stated criteria (Sec. 17-13).
  • Subdivision entrance signs located in the right-of-way (where allowed) require written authorization of the Commissioner of Public Works, proof of permanent maintenance, and an encroachment permit prior to issuance of a sign permit; and must not be located within the sight triangle or create a traffic hazard (appears in multiple zone provisions, e.g., Sec. 17-11(a)(1)(a), 17-11(c)(1)(a), 17-11(e)(10)(c), 17-11(o)(4)).
  • Certain subdivision signs in B-3/CN/B-4/I-1/I-2 zones are allowed only for projects governed by a unified development plan and exceeding four acres (Sec. 17-11(g)(9)).
  • Article 17 does not specify a master sign plan requirement; approvals are processed via the standard sign permit, Board of Adjustment variance process, and specialized review (e.g., landmark/district identification signs).

Source: amlegal municipal code