Questions? Call us at (262) 218-2915

Sign Regulations in St Tammany Parish, Louisiana

St Tammany Parish, Louisiana has specific sign regulations covering 37 sign types across 11 zoning districts. Regulated sign types include Wall Sign (Single Street-Facing Facade), Awning/Marquee/Canopy Sign (In Lieu of Wall Sign), Hanging/Under-Awning/Under-Canopy/Under-Gallery Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: January 29, 2026

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for St Tammany Parish, Louisiana

Sample Sign Requirements in St Tammany Parish

Sign TypeMax HeightMax AreaSetback
Temporary Sign (All Zoning Districts)Not listed32 sq ft per signNot listed
Temporary Window Sign (All Zoning Districts)Not listedAggregate coverage ≤25% of the area of any window in which signs are displayedNot listed
Electronic Variable Message Display (Component of Pylon/Monument/Billboard)Not listedEVM image component ≤35% of total sign area for pylon and monument signs≥300 ft from residential buildings and residential zoning districts

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for St Tammany ParishFull Coverage

Sign Types Covered

37

  • Wall Sign (Single Street-Facing Facade)
  • Awning/Marquee/Canopy Sign (In Lieu of Wall Sign)
  • Hanging/Under-Awning/Under-Canopy/Under-Gallery Sign
  • Billboard
  • +2 more types

Zoning Districts

11

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for St Tammany Parish

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

In St Tammany Parish, the height limit for A-frame Sign (Sandwich Board) in the Neighborhood Office District (NC-1) and other zoning districts is 4 ft (Sec. 600-4.3(B)(5)(a)-(g)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in St Tammany Parish require a permit. From the submission notes on this page: Construction signs require a sign permit; a building permit for the project must be obtained before the sign permit; size and display duration limits apply by zoning. Run a code check for an exact address to see the permit requirements for that zone.

St Tammany Parish's sign code covers 37 sign types, including Wall Sign (Single Street-Facing Facade), Awning/Marquee/Canopy Sign (In Lieu of Wall Sign), Hanging/Under-Awning/Under-Canopy/Under-Gallery Sign, and Billboard. Most commercial signs need a permit. The ordinance lists 4 exemptions. One of them: Temporary signs in all zoning districts do not require a permit if they are on a development site for no more than 60 days, limited to one per site (or one per street frontage on multi-frontage sites), and do not exceed 32 square feet per sign. The full list is on this page.

In St Tammany Parish, Electronic Variable Message Display (Component of Monument/Pylon) in the Planned Business Campus District (PBC) and other zoning districts must be set back at least 300 ft from residential buildings/zoning districts (Sec. 600-4.3(E)(1)-(3)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in St Tammany Parish's sign ordinance that cover digital, changing, or flashing signs: Flashing signs are prohibited. Animation on electronic changeable message signs is prohibited. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research St Tammany Parish Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in St Tammany Parish, Louisiana, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

St Tammany Parish, Louisiana Sign Rules at a Glance

St Tammany Parish, Louisiana regulates 37 sign types across 11 zoning districts. Drive-through Signs in the Medical Office or Clinic District (MOCD) and other zoning districts are capped at 8 ft tall and 48 sq ft, set back at least 20 ft from residential lot line. Most commercial signs in St Tammany Parish require a permit.

Detailed Sign Ordinance Requirements for St Tammany Parish, Louisiana

Sign Rules by Zoning District in St Tammany Parish (11 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones5Top ≤45 ft and lowest point ≥10 ft measured from ground level at supports or nearest edge of main traveled way, whichever is higherNew billboards: ≤378 sq ft per face; replacements of pre-8/2/2024 billboards ≥400 sq ft may be up to 672 sq ft; billboards ≤399 sq ft may be replaced up to 378 sq ftNot listed
Estate Residential District (E), Rural Residential District (R-1), Rural Residential District (R-2), Large Lot Residential District (L-1), Large Lot Residential District (L-2), Suburban Residential District (S-1), Suburban Residential District (S-2), Two-Family Residential District (TF)4Must meet general monument sign height; general max 9 ft, base/support ≤24 in height≤48 sq ft per sign faceNot listed
Low Multi-Family Residential District (M-L), Medium Multi-Family Residential District (M-M), High Multi-Family Residential District (M-H)4≤9 ft overall; base/support ≤24 in height≤40 sq ft (one side)Not listed
Neighborhood Office District (NC-1), Neighborhood Commercial District (NC-2), General Commercial District (GC-1), Public, Cultural, and Recreational District (GC-2)15Top ≤45 ft; bottom ≥10 ft (as measured)≤450 sq ft total for corner/multiple facadesNot listed
Planned Business Campus District (PBC), Highway Commercial District (HC-1), Highway Commercial District (HC-2), Highway Commercial District (HC-3), Highway Commercial District (HC-4)17Top ≤45 ft; bottom ≥10 ft≤450 sq ftNot listed
Medical Office or Clinic District (MOCD), Medical Hospital District (MHD), Medical Research District (MRD)10Top ≤45 ft; bottom ≥10 ft≤450 sq ftNot listed
Public Facilities District (PF-1), Public Facilities District (PF-2), Community-Based Facilities District (CBF-1), Primary Education District (ED-1), Higher Education District (ED-2), Animal Training/Housing District (AT)9≤25 ft; min clearance 10 ft≤450 sq ftNot listed
Light Industrial and Warehouse District (I-1), Industrial District (I-2), Heavy Industrial District (I-3), Solid Waste Management District (SWM-1), Solid Waste Management District (SWM-2), Advanced Manufacturing and Logistics District (AML)9Top ≤45 ft; bottom ≥10 ft≤450 sq ftNot listed
Planned Unit Development District (PUD)6≤45 ft from gradeTotal sign face area ≤400 sq ft per side (for multiple-tenant pylon)Not listed
Slidell Airport Overlay District (SAO), Municipal Interface Overlay District (MIO), Abita Airport Overlay District (AAO), Mobile Home Overlay District (MHO), Rural Overlay District (RO)4≤9 ft; base ≤24 inSingle facade ≤300 sq ft; corner/multiple facades ≤450 sq ftNot listed
Regional Business Center Overlay District (RBC)3≤45 ft from gradeTotal sign face area ≤400 sq ft per sideNot listed

Zone-by-Zone Sign Requirements in St Tammany Parish(sample of 3 of 11 zones)

Neighborhood Office District (NC-1), Neighborhood Commercial District (NC-2), General Commercial District (GC-1), Public, Cultural, and Recreational District (GC-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Single Street-Facing Facade)Cannot project beyond ends of wall or above roof line; cannot attach to unreinforced masonry parapet≤300 sq ft per facadeNot listedNot listedPer occupant; cumulative area limits applyMeasured along the wall of the facade where the sign is located; primary entrance facade determines measurement.Not listedUnlockSec. 600-4.3(A)(1)(a)-(f); Sec. 600-4.3(C)(1)(b)-(c); Sec. 600-4.2(C)(1)(b)-(g)
Wall Sign (Corner or Multiple Street-Facing Facades)Cannot project beyond ends of wall or above roof line; cannot attach to unreinforced masonry parapet≤450 sq ft total for corner/multiple facadesNot listedNot listedPer occupant; cumulative area limits applyOn facades facing public streets or routes of internal circulation.Not listedUnlockSec. 600-4.3(A)(1)(c)(iii); Sec. 600-4.3(A)(1)(d)-(f); Sec. 600-4.2(C)(1)(b)-(g)
Wall/Canopy Sign (Storefronts or Gas Station Canopy <32 Linear Feet)Cannot project beyond ends of wall or above roof line≤32 sq ftNot listedNot listedNot listedOn storefront or canopyNot listedUnlockSec. 600-4.3(A)(1)(c)(ii); Sec. 600-4.3(A)(1)(d)-(f)
Hanging/Under-Awning/Under-Canopy/Under-Gallery SignNot listed≤6 sq ftNot listedNot listedMax 1 per business establishmentAttached below or to the underside of an awning, canopy, breezeway, or gallery, extending over a pedestrian walkwayNot listedUnlockSec. 600-4.3(A)(3)(a)-(f)
A-frame Sign (Sandwich Board)≤4 ft≤6 sq ft per sign faceNot listedNot listed1 per useWithin 10 ft of a building entrance; directed towards pedestrian traffic; located to not interfere with pedestrian traffic or accessibilityNot listedUnlockSec. 600-4.3(B)(5)(a)-(g)
Drive-through Sign≤8 ft≤48 sq ftNot listed≥20 ft from any lot line abutting a residential zoning districtNot listedOriented toward drive-through facilities; ≥20 ft from any lot line abutting a residential zoning districtNot listedUnlockSec. 600-4.3(B) (Permitted with permit) (2)(a)-(e)
Monument Sign (General Nonresidential Uses)≤9 ft overall; base/support ≤24 in heightSingle occupancy: ≤32 sq ft per side; Multiple occupancy: ≤70 sq ft per sideNot listed≥5 ft from street property line1 per 1,000 ft of street frontage (or fraction thereof beyond each 1,000-ft increment); additional per additional street frontageSetback ≥5 ft from street property line; not within clear vision areas.Not listedUnlockSec. 600-4.3(C)(1)-(5)(a)-(e); Sec. 600-4.3(E)(3)(d)
BillboardTop ≤45 ft; bottom ≥10 ft (as measured)New: ≤378 sq ft; replacements of qualifying pre-8/2/2024 billboards: ≤672 sq ftNot listed≥15 ft from highway ROW; other clear-vision setbacks applySubject to spacing and corridor capWithin 200 ft of state/federal highway ROW; setback ≥15 ft; spacing ≥1,000 ft; ≥500 ft from residential zoning district property line; clear-vision restrictions near intersections and ramps.Not listedUnlockSec. 600-4.3(F)(1)-(10)

Planned Business Campus District (PBC), Highway Commercial District (HC-1), Highway Commercial District (HC-2), Highway Commercial District (HC-3), Highway Commercial District (HC-4)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Single Street-Facing Facade)Cannot project beyond wall ends or above roof line; cannot attach to unreinforced masonry parapet≤300 sq ftNot listedNot listedPer occupant; cumulative area limits applyMeasured along facade where located; primary entrance side sets measurementNot listedUnlockSec. 600-4.3(A)(1)(a)-(f); Sec. 600-4.2(C)(1)(b)-(g)
Wall Sign (Corner/Multiple Facades)As above≤450 sq ftNot listedNot listedNot listedOn facades facing public streets or internal circulation routesNot listedUnlockSec. 600-4.3(A)(1)(c)(iii); (d)-(f)
A-frame Sign (Sandwich Board)≤4 ft≤6 sq ft per faceNot listedNot listed1 per useWithin 10 ft of building entrance; oriented to pedestrian traffic; must not interfere with pedestrian or accessibility standardsNot listedUnlockSec. 600-4.3(B)(5)(a)-(g)
Drive-through Sign≤8 ft≤48 sq ftNot listed≥20 ft from any lot line abutting a residential zoning districtNot listedOriented to drive-through; ≥20 ft from lot line abutting a residential districtNot listedUnlockSec. 600-4.3(B) (Permitted with permit) (2)(a)-(e)
Monument Sign (General Nonresidential Uses)≤9 ft overall; base/support ≤24 in heightSingle occupancy: ≤32 sq ft per side; multiple occupancy: ≤70 sq ft per sideNot listed≥5 ft from street property line1 per 1,000 ft of street frontage (or fraction thereof beyond each 1,000-ft increment)Setback ≥5 ft from street property line; not within clear vision areasNot listedUnlockSec. 600-4.3(C)(1)-(5)(a)-(e); Sec. 600-4.3(E)(3)(d)
Pole Sign (Conditional Use Permit)≤25 ft overall; minimum clearance 10 ft from bottom of sign to highest adjacent gradeSingle occupancy: ≤75 sq ft per side; multiple occupancy: ≤150 sq ft per sideNot listed≥15 ft from nearest property line; additional clear-vision setbacks apply; ≥5 ft from dripline of protected treesMax 1 detached sign (monument or pole) per development site/parcelLot must have ≥100 ft of street frontage; within 100 ft of highway ROW; ≥15 ft from nearest property line; not within 500 ft of property line of a residentially zoned district or a single-family residential structure; spacing ≥200 ft between pole signs on same side of street; not within triangular clear-vision areas or within 500 ft of interstate ramps; cannot protrude into adjacent ROW; cannot obstruct traffic views.Not listedUnlockSec. 600-4.3(G)(1)(a)(i)-(iii), (2)(a)-(h), (3)(a)-(c), (4)(a)-(b), (5)(a)-(e), (6)(a)-(c), (7)(a)-(c)
Electronic Variable Message Display (Component of Monument/Pylon)Not listed≤35% of total sign area for pylon and monument signsNot listed≥300 ft from residential buildings/zoning districtsMax 1 per development siteOnly along street frontage as part of a pylon or monument sign (not attached/hanging)Not listedUnlockSec. 600-4.3(E)(1)-(3)
BillboardTop ≤45 ft; bottom ≥10 ftNew: ≤378 sq ft; qualifying replacements: ≤672 sq ftNot listed≥15 ft from highway ROWSubject to spacing/capWithin 200 ft of highway ROW; setback ≥15 ft; spacing ≥1,000 ft; not nearer than 500 ft to residential zoning district property lineNot listedUnlockSec. 600-4.3(F)(1)-(10)

Medical Office or Clinic District (MOCD), Medical Hospital District (MHD), Medical Research District (MRD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Single Street-Facing Facade)Cannot project beyond wall ends or above roof line≤300 sq ftNot listedNot listedPer occupantOn facade; measured per primary entrance sideNot listedUnlockSec. 600-4.3(A)(1)(a)-(f); Sec. 600-4.2(C)(1)(b)-(g)
Wall Sign (Corner/Multiple Facades)As above≤450 sq ftNot listedNot listedNot listedOn facades facing streets/internal routesNot listedUnlockSec. 600-4.3(A)(1)(c)(iii), (d)-(f)
A-frame Sign (Sandwich Board)≤4 ft≤6 sq ft per faceNot listedNot listed1 per useWithin 10 ft of building entrance; directed to pedestrian traffic; must not interfere with ADA/accessibilityNot listedUnlockSec. 600-4.3(B)(5)(a)-(g)
Monument Sign (General Nonresidential Uses)≤9 ft; base/support ≤24 inSingle occupancy ≤32 sq ft/side; Multiple occupancy ≤70 sq ft/sideNot listed≥5 ft from street property line1 per 1,000 ft of frontage (or fraction thereof beyond each 1,000-ft increment)Setback ≥5 ft from street property line; not in clear vision areasNot listedUnlockSec. 600-4.3(C)(1)-(5)(a)-(e); Sec. 600-4.3(E)(3)(d)
Pole Sign (Conditional Use Permit)≤25 ft; min clearance 10 ftSingle occupancy ≤75 sq ft/side; Multiple occupancy ≤150 sq ft/sideNot listed≥15 ft from property line; ≥5 ft from dripline of protected treesMax 1 detached sign per siteLot frontage ≥100 ft; within 100 ft of highway ROW; ≥15 ft from property line; ≥500 ft from residential district property line/single-family residential structure; spacing ≥200 ft on same side of street; clear-vision restrictions near intersections/ramps; cannot protrude into ROW; cannot obstruct traffic viewsNot listedUnlockSec. 600-4.3(G)(1)(a)(i)-(iii), (2)-(7)
Electronic Variable Message Display (Component of Monument/Pylon)Not listed≤35% of monument/pylon sign areaNot listed≥300 ft from residentialMax 1 per sitePart of monument or pylon; not attached/hangingNot listedUnlockSec. 600-4.3(E)(1)-(3)
Drive-through Sign≤8 ft≤48 sq ftNot listed≥20 ft from residential lot lineNot listed≥20 ft from any lot line abutting a residential districtNot listedUnlockSec. 600-4.3(B) (Permitted with permit) (2)(a)-(e)
BillboardTop ≤45 ft; bottom ≥10 ftNew ≤378 sq ft; qualifying replacement ≤672 sq ftNot listed≥15 ft from highway ROWSubject to spacing/capsWithin 200 ft of highway ROW; setback ≥15 ft; spacing ≥1,000 ft; ≥500 ft from residential zoning district property lineNot listedUnlockSec. 600-4.3(F)(1)-(10)

PermitPal covers all 11 zoning districts in St Tammany Parish. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in St Tammany Parish

  • Any sign not expressly permitted or exempted by the UDC is prohibited; where the UDC is silent or does not provide a basis that a sign is allowed, the sign is prohibited.
  • Signs or structures erected without a required building/sign permit are not allowed to be erected or to remain.
  • Signs that are illegal under state laws or regulations are prohibited.
  • Abandoned signs are prohibited.
  • Flashing signs are prohibited.
  • Animation on electronic changeable message signs is prohibited.
  • Revolving or rotating signs are prohibited.
  • Audible signs are prohibited.
  • Permanent beacons, searchlights, or other lights visible from a significant distance are prohibited.
  • Lasers are prohibited.
  • Parapet signs are prohibited.
  • Roof signs are prohibited.
  • Projecting signs are prohibited.
  • Portable or trailer signs are prohibited.
  • Pole signs are prohibited unless approved as required in Sec. 600-4.3(G) (conditional use and other standards).
  • Pylon signs are prohibited except as provided as part of regional commercial/office centers.
  • Signs that resemble or appear to regulate traffic or emergency devices, or that interfere with/imitate official traffic signs, signals, or devices are prohibited.
  • Signs that encroach into a public right-of-way are prohibited.
  • Snipe signs are prohibited.
  • Any sign that obstructs free and clear vision at locations where it may interfere with traffic sight lines or traffic control devices is prohibited.
  • Any sign that prevents free ingress or egress from any door, window, or fire escape is prohibited.
  • Any sign attached to a standpipe or fire escape is prohibited.
  • Signs located on public property are prohibited unless placed there under lease arrangements or otherwise permitted by legal authority; any sign attached to a public utility pole, streetlight, tree, fence, fire hydrant, bridge, curb, sidewalk, park bench, statue, memorial, or other location on public property is prohibited unless constructed, approved, or permitted by the parish.
  • Signs that are not clean and in good repair are not allowed to remain.
  • Signs that are not securely fixed on a substantial structure are not allowed to remain.
  • Signs that are not consistent with the standards in Sec. 600-4 are prohibited.

Exempt Signs in St Tammany Parish

  • Temporary signs in all zoning districts do not require a permit if they are on a development site for no more than 60 days, limited to one per site (or one per street frontage on multi-frontage sites), and do not exceed 32 square feet per sign.
  • Temporary window signs displayed on the inside of windows do not require a permit when constructed of temporary materials and, in the aggregate, cover no more than 25 percent of the area of any windows in which they are displayed.
  • Signs affixed to an active construction site do not require a permit.
  • Bench signs, as defined in Sec. 100-5, do not require a permit.

Sign Plan & Submission Notes for St Tammany Parish

  • A sign permit is required for signs unless specifically exempted; procedures and requirements are in Chapter 200 (Sec. 600-4.2.A.2).
  • Temporary special-event devices (flags, streamers, banners, inflatables, pennants) require a temporary permit from the Department of Planning and Development; limited to two times per year per business, for up to 14 consecutive days; maximum one banner per premises at 32 square feet; application must list sponsor, locations, and dates.
  • Pole signs require approval of a Conditional Use Permit per Sec. 200-3.4 and then a sign permit; submittal must include: boundary survey; scaled, dimensioned site plan showing structures, utilities, servitudes/rights-of-way, required natural areas, existing trees and drip lines, and proposed sign location; sign elevations/details (dimensions, structural details, foundation, materials, wind load); illumination and message details with light levels at property lines, wattage, shielding, and certifications.
  • Drive-through signs require a permit and must meet area, location, orientation, height, and setback standards.
  • Private directional signs require a permit (maximum 4 square feet).
  • Public directional signs require approval by the Parish Council.
  • Construction signs require a sign permit; a building permit for the project must be obtained before the sign permit; size and display duration limits apply by zoning.
  • Billboards require a permit from the department; permits for new billboards are issued only to holders of a billboard credit; credits are issued upon removal of a lawfully erected billboard and are subject to utilization deadlines, transferability, corridor restrictions, and a parish-wide cap.
  • Pylon signs are only permitted in planned developments and regional commercial/office centers and must meet area, height, spacing, and location standards; a sign permit is required.
  • No master sign plan or comprehensive sign plan requirement is specified in the provided text.

Source: municode municipal code