Hudsonville, Michigan has specific sign regulations covering 27 sign types across 8 zoning districts. Regulated sign types include Wall Sign - Painted, Wall Sign - Surface Mounted, Projecting Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 8, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Hudsonville, Michigan

Sample Sign Requirements in Hudsonville

Sign TypeMax HeightMax AreaSetback
Projecting SignNot listed8 square feetNot listed
Sign Band38 inches32-38 inches high (display surface height)Not listed
Window Sign - Surface Applied12 inches (first row), 9 inches (second row)12 inches high first row, 9 inches high second row, 90% glass length (per window)Not listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for HudsonvilleFull Coverage

Sign Types Covered

27

  • Wall Sign - Painted
  • Wall Sign - Surface Mounted
  • Projecting Sign
  • Awning and Canopy Sign
  • +2 more types

Zoning Districts

8

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Hudsonville

City WebsiteMunicipal Code7 permit application links available

Frequently Asked Questions

In Hudsonville, the height limit for Pole-Mounted Sign in the Highway Commercial District (HUD HC) and other zoning districts is 25 ft (35 ft in HUD HC). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Hudsonville require a permit. From the submission notes on this page: Permit applications must be submitted on city-provided forms with all required information. Run a code check for an exact address to see the permit requirements for that zone.

Hudsonville's sign code covers 27 sign types, including Wall Sign - Painted, Wall Sign - Surface Mounted, Projecting Sign, and Awning and Canopy Sign. Most commercial signs need a permit. The ordinance lists 17 exemptions. One of them: Historical plaques and memorials. The full list is on this page.

In Hudsonville, Pole-Mounted Sign in the Highway Commercial District (HUD HC) and other zoning districts must be set back 10 ft from property line. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Hudsonville's sign ordinance that cover digital, changing, or flashing signs: No sign shall employ any flashing, moving, oscillation, blinking, or variable intensity light, such as rolling, fading, moving, or animated parts designed to give the appearance of movement. Standard for changeable message signs: flash, undulate, pulse, explode, fireworks, blinking, chasing lights, bouncing, rotating, spinning, twisting, or similar movements are prohibited if distracting. For changeable message signs, the sign permit application shall include copy of manufacturer specifications on luminosity and a certification of compliance with City Codes. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Hudsonville Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Hudsonville, Michigan, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Hudsonville, Michigan Sign Rules at a Glance

Hudsonville, Michigan regulates 27 sign types across 8 zoning districts. Roof Signs in the Central Business Zone District (CBD) are capped at 2 feet tall and 30 sq ft. Most commercial signs in Hudsonville require a permit.

Detailed Sign Ordinance Requirements for Hudsonville, Michigan

Sign Rules by Zoning District in Hudsonville (8 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Central Business Zone District (CBD)1338 inches32-38 inches high (display surface height)Not listed
Traditional Neighborhood Center (TNC), Traditional Residential Neighborhood (TRN), Mixed-Use District (MU)1938 inches32-38 inches high (display surface height)Not listed
Highway Commercial District (HUD HC), Highway Commercial (HC), Neighborhood Commercial (NC)225 ft (35 ft in HUD HC)Varies by Table 4.05.01 and frontage/speed (see additional requirements)Not listed
Industrial and Manufacturing District (HUD IND G)235 ft300 sq ftNot listed
Residential Districts26 ft6 sq ft (individual); total 24 sq ft (combined)Not listed
Nonresidential zone districts16 ft32 sq ft (individual); total 64 sq ft (combined)Not listed
Form Generating Zoning Districts2Not listed15% of wall area, max 150 sq ftNot listed
Start free to see 1 more zone

Zone-by-Zone Sign Requirements in Hudsonville(sample of 3 of 8 zones)

Central Business Zone District (CBD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Projecting SignNot listed8 square feetNot listedNot listed1 per tenantPerpendicular to building wall; front or side elevations below second story floor.Not listedUnlockTable 4.05.01; Table 4.05.02; Section 4.05.11 A
Sign Band38 inches32-38 inches high (display surface height)Not listedNot listed1 per ground floor tenantHorizontal band above storefronts at front elevation.Not listedUnlockTable 4.05.01; Table 4.05.02; Section 4.05.11 C
Window Sign - Surface Applied12 inches (first row), 9 inches (second row)12 inches high first row, 9 inches high second row, 90% glass length (per window)90% of glass lengthNot listed1 per window paneWindows of any Retail, Commercial, or Service Use, first or side elevations.Not listedUnlockTable 4.05.01; Table 4.05.02; Section 4.05.11 D
Window Sign - NeonNot listed2 square feet/windowNot listedNot listed1 per windowInside window, first and upper floors at front or side elevations, non-residential only.Not listedUnlockTable 4.05.01; Table 4.05.02; Section 4.05.11 D
Wall Sign - PaintedNot listed15% of wall area, max 150 sq ftNot listedNot listed1 per buildingSecondary exterior wall, not front elevation.Not listedUnlockTable 4.05.01; Table 4.05.02; Section 4.05.11 E
Roof Sign2 feet30 sq ftNot listedNot listed1 per buildingAbove the cornice/roof – not on walls.Not listedUnlockTable 4.05.01; Table 4.05.02; Section 4.05.11 G
Temporary Sign - Bonus Residential Temporary & Bonus Commercial8 ft (commercial)20 sq ftNot listedNot listed1 per tenant spaceOn-premises (yard or building face). Not in public ROW.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.12 D
Temporary Sign - Bonus Temporary Sign6 ft32 sq ftNot listedNot listed1 per parcelOn-premises, outside ROW.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.12 D

Traditional Neighborhood Center (TNC), Traditional Residential Neighborhood (TRN), Mixed-Use District (MU)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Projecting SignNot listed8 sq ftNot listedNot listed1 per tenantPerpendicular to building wall; front or side elevations below second story floor.Not listedUnlockTable 4.05.01; Table 4.05.02; Section 4.05.11 A
Sign Band (Mixed-Use and Retail Type)38 inches32-38 inches high (display surface height)Not listedNot listed1 per ground floor tenantHorizontal band above storefronts at front elevation.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.11 C
Sign Band (Cottage Retail or Flex Type)36 inches24-36 inches high (display surface height)Not listedNot listed1 per ground floor tenantHorizontal band above storefronts at front elevation.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.11 C
Window Sign - Surface Applied12 inches (first row), 9 inches (second row)12 inches high first row, 9 inches high second row, 90% of glass length (per window)90% of glass lengthNot listed1 per window paneWindows of any Retail, Commercial, or Service Use, first/side elevations.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.11 D
Roof Sign2 feet30 sq ftNot listedNot listed1 per buildingAbove cornice line/roof area, not on wall.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.11 G
Ground-Mounted Sign (speed, frontage & lanes variations see additional requirements)6 feetNot listedNot listed10 feet from property line (exception: if building <20ft from line, minimum half the distance).1 per parcelMinimum 10 ft setback from property line; not in clear vision area.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.12 A; Table 4.05.03
Temporary Sign - Bonus Residential Temporary & Bonus Commercial8 ft (commercial)20 sq ftNot listedNot listed1 per tenant spaceOn-premises (yard or building face). Not in public ROW.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.12 D
Temporary Sign - Bonus Temporary Sign6 ft32 sq ftNot listedNot listed1 per parcelOn-premises, outside ROW.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.12 D

Highway Commercial District (HUD HC), Highway Commercial (HC), Neighborhood Commercial (NC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Pole-Mounted Sign25 ft (35 ft in HUD HC)Varies by Table 4.05.01 and frontage/speed (see additional requirements)Not listed10 ft from property line.1 per parcelMinimum 10 ft setback from property line, not in clear vision area.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.12 B
Ground-Mounted Sign (see variations in additional requirements)6 feetNot listedNot listed10 ft from property line (see exception if building < 20 ft)1 per parcelMinimum 10 ft setback from property line; not in clear vision area.Not listedUnlockTable 4.05.01; Table 4.05.02; 4.05.12 A

PermitPal covers all 8 zoning districts in Hudsonville. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Hudsonville

  • No sign shall be structurally unsafe or poorly maintained.
  • No sign shall cause unsafe traffic conditions or distract motorists from the road.
  • No sign shall create confusion with traffic signs or hinder vision.
  • No sign shall impede safe movement of pedestrians or safe ingress and egress from buildings or sites.
  • No sign shall be erected, constructed, installed, placed, re-built, modified, or maintained without compliance with the ordinance.
  • It is unlawful to erect, construct, install, place, re-build, modify, or maintain a sign without a permit obtained from the Zoning Director, except as otherwise exempted.
  • No sign or supporting mechanism shall be located closer than ten feet to a street right-of-way line, unless specifically indicated in other sections.
  • No sign or supporting mechanism shall extend beyond any lot lines of the property on which it is located, unless specifically indicated in other sections.
  • No sign shall be erected within six feet of any electrical conductor, electric light pole, street lamp, traffic light, or other public utility pole or standard.
  • No sign, except those established and maintained by the city, county, state, federal governments, or transportation authority, shall be located in, project into, or overhang a public right-of-way or dedicated public easement unless otherwise prohibited.
  • No sign shall be located within, project into, or overhang any clear-vision area as defined by the ordinance.
  • Pennants, streamers, banners, balloons, revolving or feather signs are prohibited as permanent signs, except as placed by government.
  • No sign shall employ any flashing, moving, oscillation, blinking, or variable intensity light, such as rolling, fading, moving, or animated parts designed to give the appearance of movement.
  • No billboards or off-premises advertising signs, except as specifically reviewed under special land use.
  • No signs containing off-premises advertising except for billboards approved as special land use.
  • No signs advertising the sale or lease of off-premises land.
  • No sign or other advertising structure shall be painted on or attached to a motor vehicle used primarily for the display of such sign; this does not prohibit standard business identification decals on vehicles used and parked in the normal course of business.
  • Any sign not specifically permitted by the Article is prohibited.
  • Illumination creating glare or unduly illuminating surrounding areas is prohibited.
  • Sign illumination that could distract motorists or create other safety concerns is prohibited.
  • Externally, internally illuminated, and neon signs are not allowed in residential districts.
  • Wiring for illumination fixtures shall not be exposed on a building face or other adjacent surfaces.
  • Temporary signs must not use anchoring methods such as tying weighted objects like cinder blocks or tires.
  • Temporary signs must not obstruct views of motorists.
  • Wheeled signs are not allowed within public frontages or parking lots.
  • Billboards are not permitted unless approved as a Special Land Use Permit and only in designated zones.
  • Billboards shall not use moving parts or be illuminated.
  • Billboards shall not be erected above any building.
  • Moveable freestanding signs and flags are not permitted as nonconforming signs.
  • Neon signs are not allowed in residential districts.
  • Standard for changeable message signs: flash, undulate, pulse, explode, fireworks, blinking, chasing lights, bouncing, rotating, spinning, twisting, or similar movements are prohibited if distracting.
  • Illumination (all forms) must be shielded and directed away from all residential property and Residential Districts.

Exempt Signs in Hudsonville

  • Address numbers with a numerical height no greater than 12 inches.
  • Signs posted by Governmental Units for temporary special events, as long as event signs and banners do not exceed stipulated sizes, duration, or conflict with traffic/view.
  • Flags (up to three per lot, with limits on size and placement).
  • Bonus temporary signs placed in conjunction with construction of a new facility or with site plan approval, up to 50 square feet, removed at construction end or occupancy; one per street frontage.
  • Holiday decorations for nationally recognized holidays, removed within 15 days after the holiday.
  • Minor signs intended to direct traffic flow (not exceeding 6 sq. ft. or 6 ft. height), and gas pump signs (not exceeding 3 sq. ft.).
  • Building structure name signs and date signs, integral to the building, not exceeding 12 sq. ft.
  • Temporary interior window signs affixed for easy removal, up to 10% of window glass area.
  • Interior window signs for credit card insignias (1 sq. ft. or less total).
  • Interior window signs for product logos (6 sq. ft. or less total, related to business).
  • Murals as works of art without commercial message, not advertising, and not relating to the business (subject to review and determination per Section 4.05.08.A.12).
  • Traffic, street, and parking signs erected by a public agency.
  • Sandwich board signs that comply with subsection 4.05.12 C.
  • Bonus Residential Temporary signs that comply with subsection 4.05.12 C.
  • Bonus Commercial Temporary signs that comply with subsection 4.05.12 C.
  • Historical plaques and memorials.
  • Non-commercial message signs that comply with specified requirements for residential and non-residential districts.

Sign Plan & Submission Notes for Hudsonville

  • A sign permit is required for any sign unless specifically exempted (e.g., sign face replacement with no other changes).
  • Permit applications must be submitted on city-provided forms with all required information.
  • Special Land Use Permit is required for billboards and certain other signage types (e.g., some wall signs on frontage for mixed-use buildings over 25,000 sq ft).
  • Murals: Prior to installation, a property owner or tenant must apply for a determination from the Zoning Director or designee as to whether an art design is a sign, a Type 1 mural, or a Type 2 mural.
  • For changeable message signs, the sign permit application shall include copy of manufacturer specifications on luminosity and a certification of compliance with City Codes.
  • All signs are subject to compliance inspection after installation.
  • Removal, repair, or modification deadlines are enforced by written notice for non-compliant signs.
  • For nonconforming signs, replacement or alteration may trigger requirements; some exceptions apply as listed.
  • Bonus Temporary Residential and Commercial Signs do not require a permit, as stated in 4.05.12.D.13.e and 4.05.12.D.14.e.
  • A sign plan/master sign plan or variance meeting is not explicitly referenced in these sections; allusions to plans are referenced through permitting and sign permit application requirements.

Source: municode municipal code