Sign Regulations in Quincy, Michigan

Quincy, Michigan has specific sign regulations covering 29 sign types across 5 zoning districts. Regulated sign types include Small Sign, Additional Signage for Sale or Lease, Wall Sign - Storefront. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: January 13, 2026

Sign Regulation Overview for Quincy, Michigan

Sample Sign Requirements in Quincy

Sign TypeMax HeightMax AreaSetback
Construction Sign6 feet16 square feet—
Small Sign—Under 2 square feet—
Temporary Sign6 feet16 square feet per sign—

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for QuincyFull Coverage

Sign Types Covered

29

  • Small Sign
  • Additional Signage for Sale or Lease
  • Wall Sign - Storefront
  • Wall Sign - Upper Floor
  • +2 more types

Zoning Districts

5

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Quincy

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

Sign height limits in Quincy vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Quincy, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Quincy, regulated sign types include Small Sign, Additional Signage for Sale or Lease, Wall Sign - Storefront, Wall Sign - Upper Floor, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Quincy vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Quincy are regulated with specific requirements for brightness, animation, and message duration. Quincy has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Quincy Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Quincy, Michigan — with citations from the municipal code.

No credit card required · Get results in seconds

Quincy, Michigan Sign Rules at a Glance

Quincy, Michigan regulates 29 sign types across 5 zoning districts. Freestanding Sign - Residential Developments in the Residential District (R-1, R-2, R-3) zoning district are capped at 6 feet tall and 24 square feet, with a At least 4 feet from all lot lines setback (Sec. Section 11.07.A.4.a). Most commercial signs in Quincy require a permit.

Detailed Sign Ordinance Requirements for Quincy, Michigan

Sign Rules by Zoning District in Quincy (5 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones66 feet16 square feet—
Residential District (R-1, R-2, R-3)116 feet100 square feet—
Commercial District (C)1248 inches100 square feet—
Central Business District (CBD)1348 inches100 square feet—
Industrial District (I)116 feet100 square feet—

Zone-by-Zone Sign Requirements in Quincy(sample of 3 of 5 zones)

Residential District (R-1, R-2, R-3)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Temporary Sign6 feet16 square feet per sign——2 per public street frontageOn private property, not in public right-of-way—UnlockSection 11.04.D
Wall Sign - Home Occupation—2 square feet——1 per lotAttached to and parallel to exterior wall of building, extending no more than 12 inches—UnlockSection 11.07.A.3.b
Freestanding Sign - Home Occupation—2 square feet—At least 4 feet from all lot lines1 per lotSupported on ground, not attached to building—UnlockSection 11.07.A.4.b
Freestanding Sign - Residential Development6 feet24 square feet—At least 4 feet from all lot lines1 per vehicle entranceAt vehicle entrances of residential developments (subdivisions, apartments, etc.)—UnlockSection 11.07.A.4.a
Wall Sign - Multi-Unit Residential—100 square feet90% of the width of the facade—No limit provided area standards metAttached to and parallel to exterior wall of building, extending no more than 12 inches; on facade facing public road, alley, or parking lot—UnlockSection 11.07.A.3.c and B.1
Wall Sign - Non-Residential Use—100 square feet90% of the width of the facade—No limit provided area standards metAttached to and parallel to exterior wall of building, extending no more than 12 inches; on any facade facing public road, alley, or parking lot—UnlockSection 11.07.A.1 and B.1
Freestanding Sign - Non-Residential Use6 feet40 square feet—At least 4 feet from all lot lines1 per premises (shared for multi-tenant)Supported on ground, not attached to building—UnlockSection 11.07.A.1 and B.3
Directional Sign - Non-Residential Use4 feet4 square feet——1 per approved drivewayDirecting to persons navigating site—UnlockSection 11.07.A.1 and B.3.i

Commercial District (C)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Small Sign—Under 2 square feet——Not more than 5 per lot——UnlockSection 11.04.A
Wall Sign - Storefront—100 square feet90% of the width of the facade—No limit provided area standards metAttached to and parallel to exterior wall of building, extending no more than 12 inches; on any facade facing public road, alley, or parking lot—UnlockSection 11.07.B.1
Wall Sign - Upper Floor—5 square feet——1 per entranceway (shared)Attached to wall above or near entranceway serving upper-floor businesses—UnlockSection 11.07.B.1.b
Wall Sign - No Storefront—100 square feet90% of the width of the facade—No limit provided area standards metAttached to and parallel to exterior wall of building, extending no more than 12 inches; on facade facing public road, alley, or parking lot—UnlockSection 11.07.B.1.c
Awning/Marquee Sign—70% of awning face area or 90% of marquee face——1 per ground-floor businessAffixed flat to surface of awning or marquee projecting from building—UnlockSection 11.07.B.2
Freestanding Sign6 feet40 square feet—At least 4 feet from all lot lines1 per premisesSupported on ground, not attached to building—UnlockSection 11.07.B.3
Directional Sign4 feet4 square feet——1 per approved drivewayDirecting navigation into or within site—UnlockSection 11.07.B.3.i
Sandwich Board Sign48 inches12 square feet36 inches—1 per customer entranceOutside customer entrance, providing 5 ft pedestrian passage—UnlockSection 11.06.A

Central Business District (CBD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Sign - Storefront—30 square feet90% of the width of the facade—No limit provided area standards metAttached to and parallel to exterior wall of building, extending no more than 12 inches; on any facade facing public road, alley, or parking lot—UnlockSection 11.07.B.1
Wall Sign - Upper Floor—5 square feet——1 per entranceway (shared)Attached to wall above or near entranceway serving upper-floor businesses—UnlockSection 11.07.B.1.b
Wall Sign - No Storefront—100 square feet90% of the width of the facade—No limit provided area standards metAttached to and parallel to exterior wall of building, extending no more than 12 inches; on facade facing public road, alley, or parking lot—UnlockSection 11.07.B.1.c
Awning/Marquee Sign—70% of awning face area or 90% of marquee face——1 per ground-floor businessAffixed flat to surface of awning or marquee projecting from building—UnlockSection 11.07.B.2
Freestanding Sign6 feet40 square feet—At least 4 feet from all lot lines1 per premisesSupported on ground, not attached to building—UnlockSection 11.07.B.3
Directional Sign4 feet4 square feet——1 per approved drivewayDirecting navigation into or within site—UnlockSection 11.07.B.3.i
Projecting Sign—16 square feet per face——1 per business (or 1 shared per entrance)Projects from building over sidewalk/right-of-way—UnlockSection 11.07.B.4
Sandwich Board Sign48 inches12 square feet36 inches—1 per customer entranceOutside customer entrance, providing 5 ft pedestrian passage—UnlockSection 11.06.A

PermitPal covers all 5 zoning districts in Quincy. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements — illumination rules, size formulas, and permit requirements for every sign type — with a free account.

Run a code check for your exact address — free

Prohibited Signs in Quincy

  • Signs which obstruct free access or egress from any building.
  • Signs which in any way simulate or could be confused with the lighting of emergency vehicles or traffic signals.
  • Signs which obstruct or impair the vision of motorists or non-motorized travelers at any intersection, driveway, within a parking lot or loading area.
  • Signs having moving members or parts or spinners, or using high intensity or flashing lights.
  • Non-regulatory signs placed in any public right-of-way, including those attached to a utility pole or affixed to a tree in a public right-of-way, excepting awning and projecting signs that are attached to buildings and project over the sidewalk, and except as permitted in Section 11.06.D.
  • Signs that project above the roof line.
  • Any sign erected without the consent of the owner of the property.
  • Billboards, unless explicitly permitted by MDOT.
  • Signs that make noises of any type.
  • Signs that block the view of other signs, in the opinion of the Zoning Administrator.

Exempt Signs in Quincy

  • Signs under two square feet (with district-specific limits on number).
  • Construction signs (one per project, max 6 ft height, 16 sq ft area, removed within 14 days of occupancy).
  • Flags (up to three per premises).
  • Temporary signage in R-1, R-2, R-3 districts (max two per street frontage, 6 ft height, 16 sq ft each, on private property, good condition, permit if over 6 months unless marketing).
  • Additional signage for sale/lease in C, CBD, I districts (up to 16 sq ft, removed upon sale/lease).
  • Regulatory, directional, and street signs erected by a public agency in compliance with Michigan Manual of Uniform Traffic Control Devices.
  • Signs on motor vehicles or trailers with current plates, traveling or parked (not primarily for sign display, max one per advertiser).
  • Murals (must inform Village and show design; may require permit if deemed a sign or referred to Planning Commission).

Sign Plan & Submission Notes for Quincy

  • Sign permit applications for new buildings or additions require Planning Commission review as part of site plan review, with proposed signs shown on the site plan.
  • For multi-tenant freestanding signs in C, CBD, I districts, the premises owner must propose the sign with approval from all tenants prior to permit issuance.
  • For wall signs on commercial/industrial buildings without storefronts in C, CBD, I districts, the building owner must request the permit with approval from all tenants.
  • Modifications or waivers to sign standards require Planning Commission approval after a public hearing, meeting specific criteria including no endangerment to public safety, consistency with area character, and inadequacy of standard design.

Source: other municipal code