Sign Regulations in Quincy, Michigan
Quincy, Michigan has specific sign regulations covering 29 sign types across 5 zoning districts. Regulated sign types include Small Sign, Additional Signage for Sale or Lease, Wall Sign - Storefront. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: January 13, 2026
Sign Regulation Overview for Quincy, Michigan
Sample Sign Requirements in Quincy
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Construction Sign | 6 feet | 16 square feet | — |
| Small Sign | — | Under 2 square feet | — |
| Temporary Sign | 6 feet | 16 square feet per sign | — |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
29
- Small Sign
- Additional Signage for Sale or Lease
- Wall Sign - Storefront
- Wall Sign - Upper Floor
- +2 more types
Zoning Districts
5
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Quincy
Other Cities in Michigan
Frequently Asked Questions
Sign height limits in Quincy vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.
To get a sign permit in Quincy, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.
In Quincy, regulated sign types include Small Sign, Additional Signage for Sale or Lease, Wall Sign - Storefront, Wall Sign - Upper Floor, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.
Sign setback requirements in Quincy vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.
Digital and LED signs in Quincy are regulated with specific requirements for brightness, animation, and message duration. Quincy has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.
Ready to Research Quincy Sign Permits?
Stop spending hours searching through municipal codes. Get instant access to Quincy, Michigan sign regulations with PermitPal's AI-powered platform.
No credit card required · Get results in seconds
Quincy, Michigan Sign Rules at a Glance
Quincy, Michigan regulates 29 sign types across 5 zoning districts. Freestanding Sign - Residential Developments in the Residential District (R-1, R-2, R-3) zoning district are capped at 6 feet tall and 24 square feet, with a At least 4 feet from all lot lines setback (Sec. Section 11.07.A.4.a). Most commercial signs in Quincy require a permit.
Detailed Sign Ordinance Requirements for Quincy, Michigan
Sign Rules by Zoning District in Quincy (5 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 6 | 6 feet | 16 square feet | — |
| Residential District (R-1, R-2, R-3) | 11 | 6 feet | 100 square feet | — |
| Commercial District (C) | 12 | 48 inches | 100 square feet | — |
| Central Business District (CBD) | 13 | 48 inches | 100 square feet | — |
| Industrial District (I) | 11 | 6 feet | 100 square feet | — |
Zone-by-Zone Sign Requirements in Quincy(sample of 3 of 5 zones)
Residential District (R-1, R-2, R-3)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Temporary Sign | 6 feet | 16 square feet per sign | — | — | 2 per public street frontage | On private property, not in public right-of-way | — | Unlock | Section 11.04.D |
| Wall Sign - Home Occupation | — | 2 square feet | — | — | 1 per lot | Attached to and parallel to exterior wall of building, extending no more than 12 inches | — | Unlock | Section 11.07.A.3.b |
| Freestanding Sign - Home Occupation | — | 2 square feet | — | At least 4 feet from all lot lines | 1 per lot | Supported on ground, not attached to building | — | Unlock | Section 11.07.A.4.b |
| Freestanding Sign - Residential Development | 6 feet | 24 square feet | — | At least 4 feet from all lot lines | 1 per vehicle entrance | At vehicle entrances of residential developments (subdivisions, apartments, etc.) | — | Unlock | Section 11.07.A.4.a |
| Wall Sign - Multi-Unit Residential | — | 100 square feet | 90% of the width of the facade | — | No limit provided area standards met | Attached to and parallel to exterior wall of building, extending no more than 12 inches; on facade facing public road, alley, or parking lot | — | Unlock | Section 11.07.A.3.c and B.1 |
| Wall Sign - Non-Residential Use | — | 100 square feet | 90% of the width of the facade | — | No limit provided area standards met | Attached to and parallel to exterior wall of building, extending no more than 12 inches; on any facade facing public road, alley, or parking lot | — | Unlock | Section 11.07.A.1 and B.1 |
| Freestanding Sign - Non-Residential Use | 6 feet | 40 square feet | — | At least 4 feet from all lot lines | 1 per premises (shared for multi-tenant) | Supported on ground, not attached to building | — | Unlock | Section 11.07.A.1 and B.3 |
| Directional Sign - Non-Residential Use | 4 feet | 4 square feet | — | — | 1 per approved driveway | Directing to persons navigating site | — | Unlock | Section 11.07.A.1 and B.3.i |
Commercial District (C)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Small Sign | — | Under 2 square feet | — | — | Not more than 5 per lot | — | — | Unlock | Section 11.04.A |
| Wall Sign - Storefront | — | 100 square feet | 90% of the width of the facade | — | No limit provided area standards met | Attached to and parallel to exterior wall of building, extending no more than 12 inches; on any facade facing public road, alley, or parking lot | — | Unlock | Section 11.07.B.1 |
| Wall Sign - Upper Floor | — | 5 square feet | — | — | 1 per entranceway (shared) | Attached to wall above or near entranceway serving upper-floor businesses | — | Unlock | Section 11.07.B.1.b |
| Wall Sign - No Storefront | — | 100 square feet | 90% of the width of the facade | — | No limit provided area standards met | Attached to and parallel to exterior wall of building, extending no more than 12 inches; on facade facing public road, alley, or parking lot | — | Unlock | Section 11.07.B.1.c |
| Awning/Marquee Sign | — | 70% of awning face area or 90% of marquee face | — | — | 1 per ground-floor business | Affixed flat to surface of awning or marquee projecting from building | — | Unlock | Section 11.07.B.2 |
| Freestanding Sign | 6 feet | 40 square feet | — | At least 4 feet from all lot lines | 1 per premises | Supported on ground, not attached to building | — | Unlock | Section 11.07.B.3 |
| Directional Sign | 4 feet | 4 square feet | — | — | 1 per approved driveway | Directing navigation into or within site | — | Unlock | Section 11.07.B.3.i |
| Sandwich Board Sign | 48 inches | 12 square feet | 36 inches | — | 1 per customer entrance | Outside customer entrance, providing 5 ft pedestrian passage | — | Unlock | Section 11.06.A |
Central Business District (CBD)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign - Storefront | — | 30 square feet | 90% of the width of the facade | — | No limit provided area standards met | Attached to and parallel to exterior wall of building, extending no more than 12 inches; on any facade facing public road, alley, or parking lot | — | Unlock | Section 11.07.B.1 |
| Wall Sign - Upper Floor | — | 5 square feet | — | — | 1 per entranceway (shared) | Attached to wall above or near entranceway serving upper-floor businesses | — | Unlock | Section 11.07.B.1.b |
| Wall Sign - No Storefront | — | 100 square feet | 90% of the width of the facade | — | No limit provided area standards met | Attached to and parallel to exterior wall of building, extending no more than 12 inches; on facade facing public road, alley, or parking lot | — | Unlock | Section 11.07.B.1.c |
| Awning/Marquee Sign | — | 70% of awning face area or 90% of marquee face | — | — | 1 per ground-floor business | Affixed flat to surface of awning or marquee projecting from building | — | Unlock | Section 11.07.B.2 |
| Freestanding Sign | 6 feet | 40 square feet | — | At least 4 feet from all lot lines | 1 per premises | Supported on ground, not attached to building | — | Unlock | Section 11.07.B.3 |
| Directional Sign | 4 feet | 4 square feet | — | — | 1 per approved driveway | Directing navigation into or within site | — | Unlock | Section 11.07.B.3.i |
| Projecting Sign | — | 16 square feet per face | — | — | 1 per business (or 1 shared per entrance) | Projects from building over sidewalk/right-of-way | — | Unlock | Section 11.07.B.4 |
| Sandwich Board Sign | 48 inches | 12 square feet | 36 inches | — | 1 per customer entrance | Outside customer entrance, providing 5 ft pedestrian passage | — | Unlock | Section 11.06.A |
PermitPal covers all 5 zoning districts in Quincy — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.
See all 5 zones for Quincy — start freeProhibited Signs in Quincy
- Signs which obstruct free access or egress from any building.
- Signs which in any way simulate or could be confused with the lighting of emergency vehicles or traffic signals.
- Signs which obstruct or impair the vision of motorists or non-motorized travelers at any intersection, driveway, within a parking lot or loading area.
- Signs having moving members or parts or spinners, or using high intensity or flashing lights.
- Non-regulatory signs placed in any public right-of-way, including those attached to a utility pole or affixed to a tree in a public right-of-way, excepting awning and projecting signs that are attached to buildings and project over the sidewalk, and except as permitted in Section 11.06.D.
- Signs that project above the roof line.
- Any sign erected without the consent of the owner of the property.
- Billboards, unless explicitly permitted by MDOT.
- Signs that make noises of any type.
- Signs that block the view of other signs, in the opinion of the Zoning Administrator.
Exempt Signs in Quincy
- Signs under two square feet (with district-specific limits on number).
- Construction signs (one per project, max 6 ft height, 16 sq ft area, removed within 14 days of occupancy).
- Flags (up to three per premises).
- Temporary signage in R-1, R-2, R-3 districts (max two per street frontage, 6 ft height, 16 sq ft each, on private property, good condition, permit if over 6 months unless marketing).
- Additional signage for sale/lease in C, CBD, I districts (up to 16 sq ft, removed upon sale/lease).
- Regulatory, directional, and street signs erected by a public agency in compliance with Michigan Manual of Uniform Traffic Control Devices.
- Signs on motor vehicles or trailers with current plates, traveling or parked (not primarily for sign display, max one per advertiser).
- Murals (must inform Village and show design; may require permit if deemed a sign or referred to Planning Commission).
Sign Plan & Submission Notes for Quincy
- Sign permit applications for new buildings or additions require Planning Commission review as part of site plan review, with proposed signs shown on the site plan.
- For multi-tenant freestanding signs in C, CBD, I districts, the premises owner must propose the sign with approval from all tenants prior to permit issuance.
- For wall signs on commercial/industrial buildings without storefronts in C, CBD, I districts, the building owner must request the permit with approval from all tenants.
- Modifications or waivers to sign standards require Planning Commission approval after a public hearing, meeting specific criteria including no endangerment to public safety, consistency with area character, and inadequacy of standard design.
Source: other municipal code