Sign Regulations in Pascagoula, Mississippi

Pascagoula, Mississippi has specific sign regulations covering 37 sign types across 5 zoning districts. Regulated sign types include Nameplate Sign (Commercial/Industrial Only - No Permit), Incidental Window/Door Signage (Commercial/Industrial Only - No Permit), Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 27, 2026

Sign Regulation Overview for Pascagoula, Mississippi

Sample Sign Requirements in Pascagoula

Sign TypeMax HeightMax AreaSetback
Address/Name Sign (Noncommercial)1 sq ftNot within 10 ft of a property line fronting on a street or within 5 ft of any other property line.
Real Estate Sign (Residential Districts)8 sq ftNot within 10 ft of street-front property line; not within 5 ft of other property lines.
Political Sign (Residential Districts)5 sq ftNot within 10 ft of street-front property line; not within 5 ft of other property lines.

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for PascagoulaFull Coverage

Sign Types Covered

37

  • Nameplate Sign (Commercial/Industrial Only - No Permit)
  • Incidental Window/Door Signage (Commercial/Industrial Only - No Permit)
  • Wall Sign
  • Projecting Sign
  • +2 more types

Zoning Districts

5

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Pascagoula

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

Sign height limits in Pascagoula vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Pascagoula, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Pascagoula, regulated sign types include Nameplate Sign (Commercial/Industrial Only - No Permit), Incidental Window/Door Signage (Commercial/Industrial Only - No Permit), Wall Sign, Projecting Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

Sign setback requirements in Pascagoula vary by zone and sign type, typically ranging from 5-15 feet from property lines. Use PermitPal for specific setback requirements at your location.

Digital and LED signs in Pascagoula are regulated with specific requirements for brightness, animation, and message duration. Pascagoula has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Pascagoula Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Pascagoula, Mississippi sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Pascagoula, Mississippi Sign Rules at a Glance

Pascagoula, Mississippi regulates 37 sign types across 5 zoning districts. Free-standing Signs in the Gateway Commercial (GC) zoning district are capped at 20 ft tall and 30 sq ft, with a ≥15 ft from street ROW; ≥5 ft from any other lot line setback (Sec. Table 6.13.F (Free-standing sign); Notes 6-8; Notes 1-2; Section 6.13.H.2). Most commercial signs in Pascagoula require a permit.

Detailed Sign Ordinance Requirements for Pascagoula, Mississippi

Sign Rules by Zoning District in Pascagoula (5 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones1
Single-Family Residential 10 (SFR 10), Single-Family Residential 8 (SFR 8), Single-Family Residential 6 (SFR 6), Mixed Residential 3 (MR 3)176 ft64 sq ft
Downtown (DT), Waterfront Mixed-Use (WMU)9n/a (minimum clear height 9 ft)20 sq ft per side
Gateway Commercial (GC)1220 ft32 sq ft
Neighborhood Commercial (NC), Community Commercial (CC), Regional Commercial (RC), Light Industrial (LI), Heavy Industrial (HI), Port (P)1940 ft400 sq ft if within 200 ft of a state or federal highway; otherwise, 300 sq ft

Zone-by-Zone Sign Requirements in Pascagoula(sample of 3 of 5 zones)

Single-Family Residential 10 (SFR 10), Single-Family Residential 8 (SFR 8), Single-Family Residential 6 (SFR 6), Mixed Residential 3 (MR 3)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Address/Name Sign (Noncommercial)1 sq ftNot within 10 ft of a property line fronting on a street or within 5 ft of any other property line.On the propertyUnlockSection 6.13.C.1.a; Section 6.13.C.2
Real Estate Sign (Residential Districts)8 sq ftNot within 10 ft of street-front property line; not within 5 ft of other property lines.Only on the property that is for sale/lease/rentUnlockSection 6.13.C.1.b(i)-(iii); Section 6.13.C.2; Section 6.13.E
Political Sign (Residential Districts)5 sq ftNot within 10 ft of street-front property line; not within 5 ft of other property lines.On private property with owner’s consentUnlockSection 6.13.C.1.c(i)-(iii); Section 6.13.C.2; districts listed include SFR10, SFR8, SFR6, MR3
Construction Sign (Residential Districts)32 sq ftNot within 10 ft of street-front property line; not within 5 ft of other property lines.1 per construction projectOn the construction siteUnlockSection 6.13.C.1.e(i)-(iv); Section 6.13.C.2; Section 6.13.E
Public Warning Sign (General)Minimum necessary; if not general warning per p, 2 sq ft per sign (j)Residential district setback applies (Section 6.13.E).Up to 4 per site (for 2 sq ft-per-sign allowance)On-siteUnlockSection 6.13.C.1.j and 6.13.C.1.p
Special Event Sign (Non-Commercial in Residential)64 sq ftResidential district setback applies (Section 6.13.E).No more than two times per site per yearOn-siteUnlockSection 6.13.C.1.n(i)-(iv); Section 6.13.C.2
On-site Identification Sign for Schools/Clubs/Places of Worship/etc.16 sq ftResidential district setback applies (Section 6.13.E).1 per street frontage1 per street frontageUnlockSection 6.13.C.1.o(i)-(ii)
Subdivision or Multifamily Development Sign6 ft24 sq ftResidential district setback applies (Section 6.13.E).On-siteUnlockSection 6.13.C.1.q

Gateway Commercial (GC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Signn/a (subject to district height limits per Article 5)0.5 sq ft per linear foot of building frontage1 per establishment within development site; up to 1 per building frontage if two frontagesOn building facade (frontage of the establishment within the development site)UnlockTable 6.13.F (Wall sign); Notes 3, 4; Notes 1-2
Projecting Signn/a (subject to district height limits per Article 5)0.5 sq ft per linear foot of building frontage1 per establishment along building frontageAlong building frontageUnlockTable 6.13.F (Projecting sign); Note 5; Notes 1-4
Free-standing Sign20 ft30 sq ft≥15 ft from street ROW; ≥5 ft from any other lot line1 per site with street frontageOn-site with street frontageUnlockTable 6.13.F (Free-standing sign); Notes 6-8; Notes 1-2; Section 6.13.H.2
Canopy Signn/a (minimum clear height 9 ft)0.5 sq ft per linear foot of canopy front or side≥2 ft from curb/pavement edge1 per canopy front or sideOn canopy front or sideUnlockTable 6.13.F (Canopy sign); Notes 9-12; Notes 10-11
Undercanopy Signn/a (minimum clear height 8 ft)6 sq ft1 per establishment along canopyMounted beneath canopyUnlockTable 6.13.F (Undercanopy sign); Notes 4, 13
Directional Sign (Permitted)4 ft6 sq ft2 per driveway intersection along streetAt driveway intersections along streetUnlockTable 6.13.F (Directional sign); Notes 1-2
Temporary Sign (A-Frame)6 ft20 sq ft per side1 per establishmentDirectly adjacent to the establishment; placed to maintain free pedestrian traffic including ADA access; cannot block access to other establishments; only placed when the establishment is openUnlockTable 6.13.F (Temporary sign); Notes 14-15; Notes 1-2
Construction Sign (Commercial Districts - No Permit)32 sq ft1 per construction projectOn the construction siteUnlockSection 6.13.C.1.e(i)-(iv); Section 6.13.C.2

Neighborhood Commercial (NC), Community Commercial (CC), Regional Commercial (RC), Light Industrial (LI), Heavy Industrial (HI), Port (P)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall Signn/a (subject to district height limits per Article 5)1 sq ft per linear foot of building frontage1 per establishment within development site; up to 1 per building frontage if two frontagesOn building facade (frontage of the establishment within the development site)UnlockTable 6.13.G (Wall sign); Notes 3-4; Notes 1-2
Projecting Signn/a (subject to district height limits per Article 5)1 sq ft per linear foot of building frontage1 per establishment along building frontageAlong building frontageUnlockTable 6.13.G (Projecting sign); Notes 5; Notes 1-4
Free-standing Sign40 ft1 sq ft per linear foot of building frontage (up to total 300 sq ft for shopping center free-standing signs)≥15 ft from street ROW; ≥5 ft from any other lot line1 per site; for shopping centers/planned commercial subdivisions, 1 per building frontage up to max 2 per siteOn-siteUnlockTable 6.13.G (Free-standing sign); Notes 6-9; Notes 1-2; Section 6.13.H.2
Roof Signn/a (subject to district height limits per Article 5)≤200 sq ft OR ≤1 sq ft per linear foot of building frontage parallel to sign face (whichever is less)1 per buildingMounted on roofUnlockTable 6.13.G (Roof sign); Note 10; Notes 1-2
Canopy Signn/a (minimum clear height 9 ft)0.5 sq ft per linear foot of canopy front or side≥2 ft from curb/pavement edge1 per canopy front or sideOn canopy front or sideUnlockTable 6.13.G (Canopy sign); Notes 11-14; Notes 12-13
Undercanopy Signn/a (minimum clear height 8 ft)6 sq ft1 per siteMounted beneath canopyUnlockTable 6.13.G (Undercanopy sign); Notes 4, 15
Directional Sign (Permitted)4 ft12 sq ft2 per driveway intersection along streetAt driveway intersections along streetUnlockTable 6.13.G (Directional sign); Notes 1-2
Billboard Sign (Replacement of Damaged/Destroyed Nonconforming Only)n/a (sign face must be ≥10 ft above elevation of adjacent street roadway)400 sq ft if within 200 ft of a state or federal highway; otherwise, 300 sq ft≥15 ft from street ROW; ≥5 ft from any other lot line; sign face ≥10 ft above adjacent street roadway elevationn/a (must meet spacing requirements)On-site in eligible districtsUnlockTable 6.13.G (Billboard sign); Notes 7, 18-20; Section 6.13.H.2

PermitPal covers all 5 zoning districts in Pascagoula — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 5 zones for Pascagoula — start free

Prohibited Signs in Pascagoula

  • All signs not expressly allowed by this section (with or without a Sign Permit) are prohibited.
  • Signs tacked or tied to, or posted on, any fire hydrant, tree, lamp post, utility pole, fence, post, or rock.
  • Signs hung or supported from another sign that are not built as an integral part of the other sign.
  • Temporary signs other than those listed in Section 6.13.C or Section 6.13.F.
  • Signs placed wholly or partially on, or encroaching into the space above, a street right-of-way or any other public property unless otherwise authorized in this section.
  • Animated signs.
  • Abandoned signs.
  • Unsafe signs.
  • Unlawful signs.
  • Bench signs on private property.
  • Signs that purport to be, imitate, or resemble an official traffic control sign or signal.
  • Signs attached to or placed against a building so as to prevent ingress or egress through any door or window, or that obstruct or are attached to a fire escape.
  • Signs painted or affixed to a motor vehicle or trailer that is conspicuously parked or located so as to be visible from a public street and is principally used to advertise a business located adjacent to the street or property (does not prohibit identification signs on vehicles used for transportation purposes).
  • Signs located on trust lands of the State of Mississippi unless erected by or on the authority of the state or federal government or a political subdivision thereof.
  • No part of any sign may be located within ten feet of an electric power line.

Exempt Signs in Pascagoula

  • Signs not exceeding 1 square foot bearing only property numbers, post box numbers, names of occupants, or similar noncommercial site identification.
  • Real estate signs (max area: 8 sq ft in residential districts, 32 sq ft in commercial districts, 100 sq ft in industrial districts), removed within 10 days after sale/lease/rent, and located only on the property for sale.
  • Political signs (max area: 5 sq ft in DT, NC, WMU, SFR10, SFR8, SFR6, MR3; 32 sq ft in all other districts), erected by/with property owner consent, posted no more than 90 days before the first election/referendum, removed within 15 days after the last such election/referendum.
  • Signs painted on or attached to vehicles used solely to identify the owner, business, agency, or activity that regularly uses the vehicle for transportation purposes.
  • Construction signs (one per project) with a valid building permit; max area 32 sq ft in residential/commercial districts or 100 sq ft in industrial districts; erected no more than 30 days before construction begins and removed within 30 days after completion.
  • Non-electrical directional signs not exceeding 4 square feet.
  • Non-electrical on-site facility identification signs (e.g., restrooms, public telephones) not exceeding 4 square feet.
  • Integral signs.
  • Institutional bulletin board signs not exceeding 16 square feet.
  • Public warning signs not exceeding 2 square feet per sign, with a maximum of 4 signs per site.
  • Nameplate signs not exceeding 4 square feet, fastened directly to and mounted flat against the building to which they pertain; allowed only in commercial and industrial districts.
  • Official notices posted by public officers and employees in the performance of their duty.
  • Symbols, commemorative plaques, or identification emblems of historical agencies or religious organizations not exceeding 4 square feet and mounted flat against the building or structure to which they pertain.
  • Special event signs (max 64 sq ft); posted no more than 30 days before the event and removed within 7 days after; not more than two times per site per year; special event signs advertising commercial activities are not allowed in residential districts.
  • On-site identification signs for schools, clubs, places of worship, golf courses, country clubs, cemeteries, or similar uses (max one per street frontage; max area 16 sq ft).
  • Public warning signs with no advertising message, minimum area necessary to convey the warning, removed as soon as the danger has passed.
  • Subdivision or multifamily development signs not exceeding 24 square feet in area or 6 feet in height.
  • Public signs.
  • Seasonal or holiday signs.
  • Garage sale signs not exceeding 4 square feet, placed on the site of the sale.
  • Incidental signage on a building surface, door/window, or on-site sign conveying only messages such as accepted credit cards, trade affiliations, trading stamps, and official notices required by law; allowed only in commercial and industrial districts; max 6 sq ft for any grouping in one location and 12 sq ft cumulative per site.
  • If any exempt sign is a swinging sign, its sign area shall not exceed 6 square feet.
  • Exempt signs remain subject to applicable standards in Section 6.13 and may require a Building Permit in accordance with the Building Code.

Sign Plan & Submission Notes for Pascagoula

  • No master sign plan or sign plan requirement is stated in the provided text.
  • All signs not listed as exempt in Section 6.13.C require a Sign Permit per Section 2.5.H.
  • Exempt signs may still require a Building Permit per the Building Code.

Source: other municipal code