Sign Regulations in Webster Groves, Missouri

Webster Groves, Missouri has specific sign regulations covering 29 sign types across 4 zoning districts. Regulated sign types include Wall Sign, Freestanding Sign, Projecting Sign (C, D, PC Multi-story). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 9, 2025

Sign Regulation Overview for Webster Groves, Missouri

Sample Sign Requirements in Webster Groves

Sign TypeMax HeightMax AreaSetback
Wall SignNot above roofline; In multi-story (C, D, PC): Not above floor line of 3rd story. All other areas: Not above floor line of 2nd story. (Section 54.075.C)10% of wall area
Freestanding Sign25 ft. (or up to 40 ft. if within 250 ft. of interstate highway, under specified conditions) (Section 54.071.C)Max 48 sqft per faceNot within 30 ft sight triangle; 10 ft side property line
Projecting Sign (C, D, PC Multi-story)Not above floor line of 3rd floor (Section 54.074.C.2)16 sqft per face, 32 sqft total all facesNot within 3 ft of curb line

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Webster GrovesFull Coverage

Sign Types Covered

29

  • Wall Sign
  • Freestanding Sign
  • Projecting Sign (C, D, PC Multi-story)
  • Projecting Sign (Other Districts)
  • +2 more types

Zoning Districts

4

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Webster Groves

City WebsiteMunicipal Code4 permit application links available

Frequently Asked Questions

In Webster Groves, wall signs can be up to Not above roofline; In multi-story (C, D, PC): Not above floor line of 3rd story. All other areas: Not above floor line of 2nd story. (Section 54.075.C) and monument signs are limited to 25 ft. (or up to 40 ft. if within 250 ft. of interstate highway, under specified conditions) (Section 54.071.C). Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Webster Groves, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Webster Groves, regulated sign types include Wall Sign, Freestanding Sign, Projecting Sign (C, D, PC Multi-story), Projecting Sign (Other Districts), and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Webster Groves, monument signs typically require a Not within 30 ft sight triangle; 10 ft side property line setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Webster Groves are regulated with specific requirements for brightness, animation, and message duration. Webster Groves has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Webster Groves Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Webster Groves, Missouri sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Webster Groves, Missouri Sign Rules at a Glance

Webster Groves, Missouri regulates 29 sign types across 4 zoning districts. Freestanding Signs in the General Regulations For All Zones zoning district are capped at 25 ft. (or up to 40 ft. if within 250 ft. of interstate highway, under specified conditions) (Section 54.071.C) tall and Max 48 sqft per face, with a Not within 30 ft sight triangle; 10 ft side property line setback (Sec. Sections 54.071.A-F, 54.059, 54.051, 54.141-54.144, 54.060). Most commercial signs in Webster Groves require a permit.

Detailed Sign Ordinance Requirements for Webster Groves, Missouri

Sign Rules by Zoning District in Webster Groves (4 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones2825 ft. (or up to 40 ft. if within 250 ft. of interstate highway, under specified conditions) (Section 54.071.C)60 sqft per face
Planned Districts1No sign more than 125% of standard height10% of face area, no sign more than 125% of max allowed by code
2 more zones in PermitPal — start free

Zone-by-Zone Sign Requirements in Webster Groves(sample of 2 of 4 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding Sign25 ft. (or up to 40 ft. if within 250 ft. of interstate highway, under specified conditions) (Section 54.071.C)Max 48 sqft per faceNot within 30 ft sight triangle; 10 ft side property line1 per 100 ft of street frontage per streetOn property; not within 30 ft sight triangle of right-of-way; not within 10 ft of side lot line (Section 54.071.D.1-2, Section 54.056)UnlockSections 54.071.A-F, 54.059, 54.051, 54.141-54.144, 54.060
Projecting Sign (C, D, PC Multi-story)Not above floor line of 3rd floor (Section 54.074.C.2)16 sqft per face, 32 sqft total all facesNot within 3 ft of curb lineNo specific number stated, but included in city-wide area/number calculationsOn wall facing street; may project max 6 ft into front yard/right-of-way; not within 3 ft of curb line (Section 54.074.D.1-2)UnlockSections 54.074.A-F, 54.051, 54.059, 54.141-54.144
Projecting Sign (Other Districts)Not above floor line of 2nd floor (Section 54.074.C.2)16 sqft per face, 32 sqft total all facesNot within 3 ft of curb lineNo specific number stated, but included in city-wide area/number calculationsOn wall facing street; may project max 6 ft; not within 3 ft of curb line (Section 54.074.D.1-2)UnlockSections 54.074.A-F, 54.051, 54.059, 54.141-54.144
Portable Sign12 ft (Section 54.073.C)50 sqft per face, 100 sqft total all facesNot within 30 ft triangle of driveway/street, not within 10 ft of side lineOne per street frontageOn property; not within 30 ft sight triangle of driveway/street; not within 10 ft side property line (Section 54.073.D.1-2)UnlockSections 54.073.A-F, 54.059, 54.051, 54.141-54.144
Sandwich Board3.75 ft (45 inches) (54.090.E)6 sqft per faceNot in 30 ft sight triangle; must allow 3-ft walkway clearanceOne per businessWithin prolongated limits of space it references; not within 30-ft sight triangle; 3-ft walkway clearance (54.090.G)UnlockSection 54.090
Bulletin Board (Institution/Theater Only)6 ft (54.081.E)20 sqft per faceNot in 30-ft sight triangle1 per streetOn property to which sign refers; not in 30-ft sight triangle (54.081.G.1-2)UnlockSection 54.081
Political Sign (Temporary - Single-family)3 ft (54.088.E.1)6 sqft per faceNot in 30-ft sight triangle for signs >2.5 ft tall (54.088.G.3)Not included in number calculationsEntirely on private property unless on election day (54.088.G.1), not in right-of-way (54.088.G.2)UnlockSection 54.088
Political Sign (Temporary - Commercial)12 ft (54.088.E.1)6 sqft per faceNot in 30-ft sight triangle for signs >2.5 ft tall (54.088.G.3)Not included in number calculationsEntirely on private property unless on election day (54.088.G.1), not in right-of-way (54.088.G.2)UnlockSection 54.088

Planned Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
All permanent signage (Sign Package)No sign more than 125% of standard height10% of face area, no sign more than 125% of max allowed by codeAs specified in packageAs specified in package, but not to exceed code limits unless ARB allows a variancePer sign package, must be shown on site planUnlockSection 54.103

PermitPal covers all 4 zoning districts in Webster Groves — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 4 zones for Webster Groves — start free

Prohibited Signs in Webster Groves

  • Any sign not expressly permitted by this sign code is prohibited in the City of Webster Groves.
  • All signs must comply with all applicable provisions of the Building, Electrical, Plumbing and Municipal Codes of the City of Webster Groves.
  • No sign shall, by electronic, mechanical, environmentally activated or other means, flap, flash, flutter, glitter, move, revolve, rotate, sparkle, spin, swing, scroll text across any portion of a sign, or display video content on any portion of a sign.
  • No sign is permitted whose color, location or design resembles or conflicts with traffic control signs or devices.
  • Unless specifically exempted, no sign shall be painted on or attached to trees, shrubs, lamp posts, parking meter posts, hydrants, guard rails, bridge supports, traffic signs, stairways, benches, refuse containers, rocks, other natural features, telephone poles, utility poles or similar structures.
  • Except as specified in sections 54.083, 54.085, 54.090, and 54.092, no sign shall be placed, nor shall any person place any sign, in any public right-of-way.
  • No sign shall be erected or painted on a roof.
  • No sign shall use noise amplifiers of any kind.
  • No signs or nameplates of any type shall be allowed for home occupations.
  • Signs that project light in excess of 0.5 horizontal foot-candles as measured at the property line shall be prohibited.
  • Sign lighting shall not cause a glare or be directed in such a manner that traffic is impeded or the lighting causes a nuisance.
  • Unless specifically exempted, no sign shall be erected until a permit has been issued.
  • Unless specifically exempted, all signs shall be located upon the property to which the sign refers.
  • No sign shall be so erected on any door, window or elsewhere on any building so as to prevent free ingress or egress to or from any window, door or any fire escape of any building.
  • Any abandoned sign, including the support structure, shall be removed within 30 days after the business or product is no longer present.

Exempt Signs in Webster Groves

  • Temporary signs shall not be required to meet building, electrical or plumbing code requirements.
  • This code does not regulate any traffic and roadway signage generally governed by state statutes and that are erected by the State of Missouri, St. Louis County, or the City of Webster Groves.
  • Holiday displays are exempted from window sign area limitations for up to 30 days prior to the holiday, and 14 days after the holiday.
  • Century plaques shall not require a permit.
  • Construction signs which are temporary signs shall not require a permit.
  • Temporary political signs and semi-permanent political signs shall not require a permit.
  • Real estate signs do not require a permit.

Sign Plan & Submission Notes for Webster Groves

  • Application for a sign permit shall include, when required by the building commissioner: a site plan; the plans and specifications for said sign, including dimensions, materials, and required details of construction, including weights and methods of anchorage.
  • In planned districts, the owner/developer may propose a 'sign package' addressing all aspects of exterior permanent signage for the entire planned district. The sign package must include: a site plan showing sign location, height, and size; dimensions, area, construction materials, colors, and illumination source/level; color elevations of all proposed signs; description of advertising copy; proposed landscaping for free-standing signs.
  • Sign packages for planned districts shall be approved by the architectural review board (ARB).
  • Requests for a civic activity sign permit for a period greater than 30 days require approval by the architectural review board and, for designated historic districts, the historic preservation commission.
  • Applications for building identification signs for buildings on the national register of historic places, city-designated landmarks, and buildings in historic districts must be approved by the historic preservation commission prior to review by the architectural review board.
  • Requests for a variance from sign code standards must be reviewed by the board of adjustment after a variance application and hearing.
  • Any application for a permit to locate a sandwich board in a public right-of-way must include a certificate of liability insurance naming the city as additionally insured.

Source: municode municipal code