Englewood, New Jersey has specific sign regulations covering 23 sign types across 11 zoning districts. Regulated sign types include Address Sign, Wall Sign, Awning Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 21, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Englewood, New Jersey

Sample Sign Requirements in Englewood

Sign TypeMax HeightMax AreaSetback
Wall SignLetter height: 8 inches; Logo height: 12 inches; Sign panel height: 24 inchesTotal on front facade: 40 sq ftNot listed
Projecting SignSign: max 4 ft, Letters: 8 in, Logo: 12 in9 sq ftNot listed
Awning SignLetter: 8 in, Logo: 12 inNot listedNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for EnglewoodFull Coverage

Sign Types Covered

23

  • Address Sign
  • Wall Sign
  • Awning Sign
  • Marquee Sign
  • +2 more types

Zoning Districts

11

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Englewood

Municipal Code3 permit application links available

Frequently Asked Questions

In Englewood, the height limit for Monument Sign in the Service Business District (SBD) is 8 ft (Sec. 250-105C(4)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Englewood require a permit. From the submission notes on this page: For illuminated signs, the electrical permit application must be filed at the same time as the sign permit application. Run a code check for an exact address to see the permit requirements for that zone.

Englewood's sign code covers 23 sign types, including Address Sign, Wall Sign, Awning Sign, and Marquee Sign. Most commercial signs need a permit. The ordinance lists 15 exemptions. One of them: Temporary signs that comply with labeling, construction, placement, and duration requirements are exempt from permit and do not count toward total signage, but must follow type, number, and area limits. The full list is on this page.

In Englewood, Monument Sign in the Downtown (D-2, D-2a, D-2b, D-2c, D-2d, D-2e) zoning districts must be set back 5 ft from edge of sidewalk, 5 ft from driveway (Sec. 250-105C(2)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Englewood's sign ordinance that cover digital, changing, or flashing signs: Video displays. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Englewood Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Englewood, New Jersey, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Englewood, New Jersey Sign Rules at a Glance

Englewood, New Jersey regulates 23 sign types across 11 zoning districts. Monument Signs in the Service Business District (SBD) are capped at 8 ft tall and 40 sq ft, set back 5 ft from sidewalk/driveway (Sec. 250-105C(4)). Most commercial signs in Englewood require a permit.

Detailed Sign Ordinance Requirements for Englewood, New Jersey

Sign Rules by Zoning District in Englewood (11 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Downtown (D-1, D-1a, D-1b)10Letter height: 8 inches; Logo height: 12 inches; Sign panel height: 24 inchesTotal on front facade: 40 sq ftNot listed
Downtown (D-2, D-2a, D-2b, D-2c, D-2d, D-2e)13Letter: 8 in, Logo: 12 in, Panel: 24 in max height, panel width matches sign bandTotal on front facade: 40 sq ftNot listed
Neighborhood Center (N-C)10Letter: 8 in, Logo: 12 in, Panel: 24 in max height, panel width: sign bandTotal on front facade: 40 sq ftNot listed
Service Business District (SBD)13Letter: 10 in; Logo: 14 in40 sq ftNot listed
Light Industrial (L-I)1135 ft max40 sq ft (16 ft/5 ft wide on >50 mph roads)Not listed
Research, Industry, Medical (RIM)11Letter: 14 in, Logo: 20 in; Top floor: up to 24 in letter, 36 in logo; on >50 mph: up to 16/22 inMax 60% of sign area it's installed onNot listed
Multifamily Residence (RM-B)10Letter: 10 in, Logo: 14 in40 sq ft on front facadeNot listed
Multifamily Residential Districts (excluding RM-B)9Letter: 10 in, Logo: 14 in30 sq ft (institutional use)Not listed
Single-Family Residential Districts1Not listedNot listedNot listed
Residential Districts2Letter: 10 in, Logo: 14 in15 sq ftNot listed
General Regulations For All Zones3D-1, D-2, N-C, RM-B: 6 ft; SBD, L-I: 7 ft; RIM: 8 ftD-1, D-2, N-C, RM-B: 5 sq ft; SBD, L-I: 12 sq ft; RIM: 16 sq ftNot listed

Zone-by-Zone Sign Requirements in Englewood(sample of 3 of 11 zones)

Downtown (D-1, D-1a, D-1b)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignLetter height: 8 inches; Logo height: 12 inches; Sign panel height: 24 inchesTotal on front facade: 40 sq ftSign panel width: same as architectural sign bandNot listedNot listedBuilding facade, ground floor. Multitenant: each storefront max 40 sq ft. Corner: second facade eligible for extra 40 sq ftNot listedUnlock§250-105C(1)(a-d)
Projecting SignSign: max 4 ft, Letters: 8 in, Logo: 12 in9 sq ftNot listedNot listedOne per (qualified) second-floor tenantProjects up to 4 ft from building (2 ft if second-floor tenant). Above 8 ft from ground.Not listedUnlock§250-105C(1)(a-d)
Window Sign6 in on windows, 4 in on doorsMax 15% of window, 10% of door, illuminated: max 6 sq ft total per facade, 4 sq ft per signNot listedNot listedNot listedOn/behind windows and transparent doors; only on 1st/2nd floor.Not listedUnlock§250-105C(1)(a-d); §250-104D
Outdoor Display CaseNot listed6 sq ftNot listedNot listedOne per businessNot on windowNot listedUnlock§250-105B(3), §250-105C(1)(a,d)
Directional SignNot listed4 sq ftNot listedNot listedOneAs necessary for parking/trafficNot listedUnlock§250-104D, §250-105B(3), §250-105C(1)
Directory SignNot listed4 sq ftNot listedNot listedOne for second-floor tenantsNear entranceNot listedUnlock§250-105B(3), §250-105C(1)
Address SignLetter min 3 inNot listedNot listedNot listedOne (required)Above/near main entrance; also on any freestanding signNot listedUnlock§250-104D, §250-105B(3), §250-105C(1)
Portable Sign (D-1b only)3 ftNot listed2 ftNot listedOne per business (D-1b only)No more than 4 in from building facadeNot listedUnlock§250-105B(3), §250-105C(1)

Downtown (D-2, D-2a, D-2b, D-2c, D-2d, D-2e)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignLetter: 8 in, Logo: 12 in, Panel: 24 in max height, panel width matches sign bandTotal on front facade: 40 sq ftNot listedNot listedNot listedBuilding facade, ground floor; multitenant: max 40 sq ft per storefront; corner: extra 40 sq ft on second facade.Not listedUnlock§250-105C(2)
Projecting SignSign: max 4 ft, Letter: 8 in, Logo: 12 in9 sq ftNot listedNot listedOne per tenantPerpendicular to building, above 8 ft from ground, not above eaveline or below 2nd story windows.Not listedUnlock§250-105C(2)
Monument Sign6 ft30 sq ftNot listed5 ft from edge of sidewalk, 5 ft from drivewayOne per property (if setback met)Front yard setback ≥6 ft required; one per property; must be 5 ft from sidewalk and driveway.Not listedUnlock§250-105C(2)
Post and Panel Sign6 ft30 sq ft sign panelNot listed≥3 ft from sidewalk, ≥5 ft from drivewayOne per property (if setback met)Front yard setback ≥6 ft required; at least 3 ft from sidewalk, 5 ft from driveway.Not listedUnlock§250-105C(2)
Yard Sign6 ft8 sq ft panelNot listed≥2 ft from sidewalk, ≥5 ft from drivewayOne per property (if setback met)Front yard setback ≥6 ft required; ≥2 ft from sidewalk, 5 ft from driveway.Not listedUnlock§250-105C(2)
Window Sign6 in (windows), 4 in (doors)15% of window, 10% of door; illuminated: 6 sq ft total facade, 4 sq ft/signNot listedNot listedNot listedOn/behind windows and transparent doors.Not listedUnlock§250-105C(2)
Address SignMin 3 inNot listedNot listedNot listedOne (required)Above/near entrance; must be added to top of any freestanding sign.Not listedUnlock§250-105C(2)
Portable Sign (D-2b and D-2c only)3 ftNot listed2 ftNot listedOne per businessPlaced within 4 in of building facade.Not listedUnlock§250-105C(2)

Service Business District (SBD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignLetter: 10 in; Logo: 14 in1.5 sq ft per linear ft of frontage/min 40 sq ftNot listedNot listedNot listedBuilding facade, ground floor; corners: equal on both facades.Not listedUnlock§250-105C(4)
Projecting SignSign: max 4 ft, Letter: 10 in, Logo: 12 in9 sq ftNot listedNot listedNot listedPerpendicular to building, >8 ft above groundNot listedUnlock§250-105C(4)
Monument Sign8 ft40 sq ftNot listed5 ft from sidewalk/drivewayOne (if setback requirements met)Front yard setback ≥6 ft; one per property; 5 ft from sidewalk/driveway. Landscaping base required.Not listedUnlock§250-105C(4)
Post and Panel Sign8 ft40 sq ftNot listed≥3 ft from sidewalk, ≥5 ft from drivewayOne per propertyFront yard setback ≥6 ft; ≥3 ft from sidewalk/5 ft from driveway.Not listedUnlock§250-105C(4)
Yard Sign6 ft8 sq ftNot listed≥2 ft from sidewalk, ≥5 ft from drivewayNot listed≥2 ft sidewalk/≥5 ft from drivewayNot listedUnlock§250-105C(4)
Window Sign8 in (windows), 6 in (doors)15% window, 10% door; illuminated: 6 sq ft total facade, 4 sq ft/signNot listedNot listedNot listedOn/behind windows or doorsNot listedUnlock§250-105C(4)
Outdoor Display CaseNot listed6 sq ftNot listedNot listedOne per businessNot on windowNot listedUnlock§250-105C(4)
Portable Sign3 ftNot listed2 ftNot listedOne per businessMax 4 in from facadeNot listedUnlock§250-105C(4)

PermitPal covers all 11 zoning districts in Englewood. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Englewood

  • No sign shall be erected, placed, altered, relocated or replaced except in accordance with the ordinance and unless a permit has been issued or the sign is exempt.
  • Billboards, except in the Light Industrial (L-I) District as specified.
  • Signs carried or worn by a pedestrian that announce or call attention to any service, event, product, or place of business/occupation.
  • Signs that contain lights that flash, blink, move, or change in color or intensity.
  • Signs that contain mirrors.
  • Signs that emit smoke, visible vapors, particulate matter, sound, odor or contain open flames.
  • Signs that exhibit obscene or pornographic statements, words, or pictures as determined by City Council.
  • Signs that imitate, resemble, interfere with, or obstruct official traffic lights, signs, or signals.
  • Signs mounted, attached, or painted on a trailer, boat, or motor vehicle when parked, stored, or displayed conspicuously on private premises in a manner intended to attract public attention for advertising or identifying the business; exempting vehicles that are actively used in daily business or have permanent/magnetic signs.
  • Signs incorporating beacon, festoon, or strobe lighting.
  • Signs tacked, nailed, posted, pasted, glued, or otherwise attached to trees, poles, stakes, fences, public benches, streetlights, or other objects, or placed on public property, in the right-of-way, or on private property without owner's permission.
  • Signs extending above the roofline of the building to which it is attached.
  • Inflatable signs.
  • Linear lights.
  • Pennants, spinners, and streamers.
  • Sidewalk signs.
  • Pylon signs.
  • Video displays.
  • Temporary and limited-duration signs must also comply with all prohibitions above.
  • Signs shall not interfere with surface or underground utilities, communications lines or equipment.
  • Signs shall not block ingress or egress from doors, windows, fire escapes, or prevent roof access; except safety signs are allowed on standpipes or fire escapes.
  • Signs shall not be erected, constructed, painted, or maintained on or above the roof; no part may extend above the eave line of the building.
  • No sign may interfere with sight triangles at intersections, alleys, or driveways.
  • Signs shall not contain more than 10 items of information.
  • Signs shall not consist of more than four colors.
  • Signs inside a building that are meant to be viewed from outside, if closer than three feet from the window, are regulated as window signs.
  • Illuminated signs or lighting for signs shall not flash, blink, move, or change in color or intensity.
  • External light sources for illuminating signs must be shielded from visibility from the public thoroughfare or residences and must not cause glare.
  • All signs must be maintained in good repair and safe condition; deteriorated signs must be repaired or removed.
  • Obsolete or abandoned signs must be removed within 20 days of business closure or vacation; entire sign structure must be removed.
  • No mural or public art installation may consist of, or contain, electrical or mechanical components, or changing images, moving structural elements, flashing or sequential lights, kinetic art or lighting elements, or other automated methods that result in movement, appearance of movement, or change of mural image or message, except static illumination turned on/off not more than once every 24 hours.
  • No mural or public art installation may be placed over building openings (windows, doors, fire escapes, vents) unless permanently sealed.
  • No mural or public art installation may be arranged and illuminated to produce a light intensity greater than three footcandles above ambient lighting as measured at the property line of the nearest residential property; no illumination in residential zones between 10:00 p.m. and 5:00 a.m.
  • No more than one mural or public art installation may be located within 200 feet of another unless part of an approved ensemble.

Exempt Signs in Englewood

  • Signs erected by a government agency.
  • Address signs and nameplates in residential districts, not exceeding two square feet in area.
  • Address signs in nonresidential districts, as regulated.
  • Directional signs designating or calling attention to entrances, exits, parking areas, and loading areas. Building-mounted directional signs and sign panels of any freestanding directional signs must be <= two square feet in area and no higher than seven feet (freestanding).
  • Flags and insignia of any government, except when displayed in connection with commercial promotion.
  • Historical markers and tablets.
  • Holiday and seasonal decorations.
  • Names of buildings and dates of erection when cut into masonry or constructed of wood, bronze, stainless steel or similar material.
  • Personal expression signs of any type, including flags, that do not exceed three square feet, are noncommercial, and are not illuminated.
  • Security and warning signs: In residential districts, <= two square feet; in nonresidential districts, one sign up to four square feet, all others up to two square feet.
  • Signs inside a building, or other enclosed facility, not intended to be viewed from the outside, and located more than three feet from the window.
  • Temporary and limited-duration signs (with conditions as specified in the ordinance).
  • Temporary signs that comply with labeling, construction, placement, and duration requirements are exempt from permit and do not count toward total signage, but must follow type, number, and area limits.
  • Limited-duration signs that comply with labeling, construction, placement, and duration requirements are exempt from permit and do not count toward total signage, but must follow type, number, and area limits.
  • Outdoor umbrellas located in the outdoor cafe area are exempt from the sign ordinance, provided they do not exceed six feet diameter, do not extend into required sidewalk area, and have no portion less than seven feet above grade.

Sign Plan & Submission Notes for Englewood

  • Site plan review is NOT required where no sign permit is required.
  • Site plan review is NOT required for alterations or the replacement of existing signage in designated commercial/industrial districts (D-1, D-2, SBD, N-C, L-I, RIM, RM-B), provided such change does not exceed or conflict with design criteria, as determined by Zoning Officer.
  • If the building facade on which existing signage is placed undergoes renovation/rehabilitation tantamount to new construction (as determined by Zoning Officer), site plan review is REQUIRED.
  • In all other instances (not meeting above exemptions), site plan review is REQUIRED for signs.
  • The Planning Board (or Zoning Board under its site plan authority) has ultimate authority to approve signs as part of site plan review and upon public notice and hearing.
  • For illuminated signs, the electrical permit application must be filed at the same time as the sign permit application.
  • If a property applies for subdivision or land development requiring site plan review, all nonconforming signs on that property must be brought into conformance.
  • The property on which a nonconforming sign is located and which undergoes a change of land use requiring a use-and-occupancy permit also triggers a requirement to bring signage into conformance.
  • Murals and public art installations require site plan review by the Planning Board at a regularly scheduled meeting.
  • Murals and public art installations require submission of a maintenance plan and guarantee in the form of a bond for ongoing compliance and maintenance.
  • Alterations to existing signs (size, shape, illumination, business name) require a permit.
  • Alterations to an existing mural or public art installation require a new permit if the changes affect size, shape, location, or design.

Source: ecode360 municipal code