Sign Regulations in Knowlton, New Jersey
Knowlton, New Jersey has specific sign regulations covering 28 sign types across 8 zoning districts. Regulated sign types include Nameplate and Identification Sign - Single-Family Dwelling, Institutional Sign - Wall, Parking Area Entrance/Exit Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: January 13, 2026
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Knowlton, New Jersey
Sample Sign Requirements in Knowlton
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| All Signs - General Safety and Maintenance | Not listed | Not listed | General minimum distance to street ROW by area (varies by zone): - AR-1 & VR: <25 sq ft → 20 ft. - FPZ, C-1, C-2, PCD: <25 sq ft → 20 ft; 26–75 sq ft → 25 ft; 76+ sq ft → 30 ft. |
| Nameplate and Identification Sign - Single-Family Dwelling | 6 ft | 1 sq ft | General minimum 20 ft from street ROW for signs <25 sq ft (§11-290D(5)(b)). |
| Sales or Rental Sign - Dwelling or Lot (Curb Sale/Rental) | Not listed | 6 sq ft | General minimum 20 ft from street ROW for signs <25 sq ft (§11-290D(5)(b)). |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
28
- Nameplate and Identification Sign - Single-Family Dwelling
- Institutional Sign - Wall
- Parking Area Entrance/Exit Sign
- Parking Area Conditions/Identity Sign
- +2 more types
Zoning Districts
8
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Knowlton
Other Cities in New Jersey
Frequently Asked Questions
In Knowlton, the height limit for Freestanding Business Sign in the Planned Commercial Development (PCD) zoning district is 15 ft. Maximum sign heights range from 6 ft to 15 ft across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Knowlton require a permit. From the submission notes on this page: When more than one sign is proposed on a property in the C‑1, C‑2 or PCD Zones, a coordinated theme for all signs is required, which is typically implemented through a Board‑approved sign plan. (C‑1 §11-314E(18); C‑2 §11-321E(18); PCD §11-328E(18)). Run a code check for an exact address to see the permit requirements for that zone.
Knowlton's sign code covers 28 sign types, including Nameplate and Identification Sign - Single-Family Dwelling, Institutional Sign - Wall, Parking Area Entrance/Exit Sign, and Parking Area Conditions/Identity Sign. Most commercial signs need a permit. The ordinance lists 1 exemption, shown in full on this page.
This page doesn't list a single setback distance for signs in Knowlton. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Knowlton's sign code includes illumination rules, but this page doesn't show the rules for digital or LED signs. Run a code check for an exact address to see them.
Ready to Research Knowlton Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Knowlton, New Jersey, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Knowlton, New Jersey Sign Rules at a Glance
Knowlton, New Jersey regulates 28 sign types across 8 zoning districts. Freestanding Business Signs in the Neighborhood Commercial (C-1) zoning district are capped at 10 ft tall and 24 sq ft per side. Most commercial signs in Knowlton require a permit.
Detailed Sign Ordinance Requirements for Knowlton, New Jersey
Sign Rules by Zoning District in Knowlton (8 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 1 | Not listed | Not listed | Not listed |
| Single-Family Agricultural Residential (AR-1) | 10 | 6 ft | 24 sq ft (freestanding) | Not listed |
| Single-Family Agricultural Residential, Farmland Preservation (FPZ) | 15 | 6 ft | 24 sq ft | Not listed |
| Village Residential (VR) | 11 | 6 ft | 24 sq ft | Not listed |
| Neighborhood Commercial (C-1) | 14 | 10 ft | Up to 80 sq ft (also ≤5% of building face). | Not listed |
| Commercial (C-2) | 13 | 15 ft | Up to 80 sq ft | Not listed |
| Planned Commercial Development (PCD) | 14 | 15 ft | Up to 80 sq ft | Not listed |
| General Regulations For All Zones - Residential Real Estate & Institutional | 2 | Not listed | 24 sq ft | Not listed |
Zone-by-Zone Sign Requirements in Knowlton(sample of 3 of 8 zones)
Single-Family Agricultural Residential, Farmland Preservation (FPZ)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Nameplate and Identification Sign - Single-Family Dwelling | 6 ft | 1 sq ft | Not listed | By table: <25 sq ft → 20 ft from ROW; 26–75 sq ft → 25 ft; 76+ sq ft → 30 ft (§11-299E(5)(b)). | 1 per dwelling unit (plus mailbox sign). | On lot of the dwelling. | Not listed | Unlock | §11-299E(1); internal illumination ban §11-299E(5)(l) |
| Sales or Rental Sign - Dwelling or Lot (Curb Sale/Rental) | Not listed | 6 sq ft | Not listed | See general setback table for sign area (§11-299E(5)(b)). | Max 1 per property; max 1 development sign. | On property being sold or rented. | Not listed | Unlock | §11-299E(2)(a)-(e) |
| Institutional Sign - Freestanding | Not listed | 24 sq ft | Not listed | By table: <25 sq ft → 20 ft; 26–75 → 25 ft; 76+ → 30 ft (§11-299E(5)(b)). | 1 per property. | On institutional property fronting street. | Not listed | Unlock | §11-299E(3)(a); §11-299E(5)(l) |
| Institutional Sign - Wall | Not listed | 24 sq ft (total on one wall) | Not listed | Not listed | Wall area limited, not explicit count. | On wall of institutional building. | Not listed | Unlock | §11-299E(3)(b); §11-299E(5)(l) |
| Parking Area Entrance/Exit Sign | Not listed | 4 sq ft | Not listed | Directional signs <3 sq ft exempt from area/location regs (§11-299E(5)(d)); otherwise use general setback table §11-299E(5)(b). | 1 per entrance/exit. | At parking area driveway. | Not listed | Unlock | §11-299E(4) |
| Parking Area Conditions/Identity Sign | Not listed | 6 sq ft | Not listed | Per area table §11-299E(5)(b). | 1 per parking area. | Within parking area. | Not listed | Unlock | §11-299E(4) |
| Private Driveway Sign | Not listed | 2 sq ft | Not listed | Not listed | Implied 1 per driveway. | At private driveway. | Not listed | Unlock | §11-299E(4) |
| Campground Entrance Sign | Not listed | 18 sq ft | Not listed | General area/distance standards of §11-299E(5)(b) apply unless modified on site plan. | 1 entrance sign per campground; multiple internal directional/traffic signs allowed. | At campground entrance, on the premises. | Not listed | Unlock | §11-297.1Q; §11-300.1A |
Neighborhood Commercial (C-1)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Business Sign | 10 ft | 24 sq ft per side | Not listed | Minimum distance from street ROW and property lines = ½ of required front yard setback (front yard = 35 ft, so sign ≥17.5 ft from ROW) and applicable side yard; plus general area/distance table (<25 sq ft → 20 ft; 26–75 → 25 ft; 76+ → 30 ft) unless waived by Approving Board (§11-314E(2)). | 1 freestanding sign per property (subject to special multi‑use provisions). | On the lot, typically near primary street frontage; must be at least half the required front yard setback distance from any road ROW or property line. | Not listed | Unlock | §11-314E(5)(c)[1]-[4]; §11-314E(6) |
| Nameplate and Identification Sign - Single-Family Dwelling | 6 ft | 1 sq ft | Not listed | General sign/setback table applies (§11-314E(2)(a)). | 1 per dwelling (plus mailbox). | On residential lot within C-1. | Not listed | Unlock | §11-314E(7); §11-314E(6) |
| Sales or Rental Sign - Existing Residential Dwelling | Not listed | 6 sq ft | Not listed | Per general area/distance table (§11-314E(2)(a)). | 1 per property. | On residential property for sale or rent. | Not listed | Unlock | §11-314E(8)(a),(b),(c) |
| Sales or Rental Sign - Commercial Property or Building | Not listed | 20 sq ft | Not listed | Per §11-314E(2)(a). | 1 per property. | On commercial property for sale/lease. | Not listed | Unlock | §11-314E(8)(a)-(c) |
| Sales or Rental Sign - Large Tract (≥5 acres, 500 ft frontage) | Not listed | 24 sq ft | Not listed | Per §11-314E(2)(a). | 1 per tract. | On the large tract offered for sale or lease. | Not listed | Unlock | §11-314E(8)(d) |
| Institutional Sign - Freestanding | Not listed | 24 sq ft | Not listed | Per §11-314E(2)(a). | 1 per property. | On institutional site in C-1. | Not listed | Unlock | §11-314E(9)(a); §11-314E(6) |
| Parking Area Entrance/Exit Sign | Not listed | 4 sq ft | Not listed | Directional signs <3 sq ft exempt from area/location regs (§11-314E(4)); others per §11-314E(2)(a). | 1 per entrance/exit. | At each vehicular entrance/exit to parking area. | Not listed | Unlock | §11-314E(10)(a) |
| Multi-use Development Freestanding Sign | Freestanding sign may project ≤6 ft above its support (pole/kiosk/etc.). | Up to 80 sq ft (also ≤5% of building face). | Not listed | ≥40 ft from street ROW or at least ½ front/rear yard setback; must meet side yard requirements; plus general distance table unless varied on site plan. | 1 freestanding sign per property, with potential 2nd if multi‑frontage and not abutting residential. | On multi‑use development property, at or near access from public street(s). Must be ≥40 ft from ROW or ½ required min front/rear yard, whichever greater, and meet side yard requirements. | Not listed | Unlock | §11-314F(4) |
Planned Commercial Development (PCD)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Freestanding Business Sign | 15 ft | 24 sq ft per side | Not listed | ≥½ of required front yard from any abutting road ROW or property line; also must observe general distance table (<25 sq ft → 20 ft; 26–75 → 25 ft; 76+ → 30 ft) unless modified by Approving Board (§11-328E(2)). | 1 freestanding sign per property (unless varied via multi‑use plan). | On the PCD lot near frontage; at least half the front yard setback from road ROW or property line. | Not listed | Unlock | §11-328E(5)(c)[1]-[4]; §11-328E(6),(16) |
| Nameplate and Identification Sign - Single-Family Dwelling | 6 ft | 1 sq ft | Not listed | Per §11-328E(2)(a). | 1 per dwelling (plus mailbox). | On residential lot in PCD. | Not listed | Unlock | §11-328E(7); §11-328E(6),(16) |
| Sales or Rental Sign - Residential Dwelling | Not listed | 6 sq ft | Not listed | Per §11-328E(2)(a). | 1 per property. | On residential property in PCD offered for sale/lease. | Not listed | Unlock | §11-328E(8)(a)-(c); §11-328E(6),(16) |
| Sales or Rental Sign - Commercial Property or Building | Not listed | 20 sq ft | Not listed | Per §11-328E(2)(a). | 1 per property. | On commercial property/building in PCD. | Not listed | Unlock | §11-328E(8)(a)-(c); §11-328E(6),(16) |
| Sales or Rental Sign - Large Tract (≥5 acres, 500 ft frontage) | Not listed | 24 sq ft | Not listed | Per §11-328E(2)(a). | 1 per tract. | On the tract being offered for sale/lease. | Not listed | Unlock | §11-328E(8)(d); §11-328E(6),(16) |
| Institutional Sign - Freestanding | Not listed | 24 sq ft | Not listed | Per §11-328E(2)(a). | 1 per property. | On institutional site within PCD. | Not listed | Unlock | §11-328E(9)(a); §11-328E(6),(16) |
| Parking Area Entrance/Exit Sign | Not listed | 4 sq ft | Not listed | Directional signs <3 sq ft exempt from area/location regs (§11-328E(4)); others per §11-328E(2)(a). | 1 per entrance/exit. | At vehicle access points to parking areas. | Not listed | Unlock | §11-328E(10)(a); §11-328E(6),(16) |
| Multi-use Development Freestanding Sign | Sign may project ≤6 ft above support (pole/stanchion/kiosk). | Up to 80 sq ft | Not listed | ≥40 ft from ROW or ≥½ of required front/rear yard setback; must meet side yard requirements; general distance table also applies unless modified. | 1 freestanding sign per property; possible 2nd under limited conditions. | On PCD multi‑use property at primary entrance(s). | Not listed | Unlock | §11-328F(4); §11-328E(6),(16) |
PermitPal covers all 8 zoning districts in Knowlton. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Knowlton
- No signs which have moving parts or which provide the illusion of movement shall be permitted; no variation in luminous intensity shall be permitted. (AR-1 §11-290D(5)(j); FP §11-299E(5)(j); VR §11-307D(5)(j); C-1 §11-314E(16); C-2 §11-321E(16); PCD §11-328E(16))
- Temporary portable signs are prohibited. (AR-1 §11-290D(5)(k); FP §11-299E(5)(k); VR §11-307D(5)(k); C-1 §11-314E(17); C-2 §11-321E(17); PCD §11-328E(17))
- No internally illuminated signs shall be permitted in AR-1, FP, VR and C-1 Zones, and no neon-type lights, no moving lights, and no internally illuminated signs shall be permitted in the PCD Zone. (AR-1 §11-290D(5)(l); FP §11-299E(5)(l); VR §11-307D(5)(l); C-1 §11-314E(6); PCD §11-328E(6))
- No sign shall be permitted which is not accessory to the business conducted on the property. (C-1 §11-314E(5); C-2 §11-321E(5); PCD §11-328E(5))
- No sign shall be permitted on rear or side walls when the wall abuts a residential use or zone or any public or institutional use. (C-1 §11-314E(5)(b); C-2 §11-321E(5)(b); PCD §11-328E(5)(b))
- Nameplate/identification signs for dwellings shall be no larger than one square foot, maximum height six feet, limited to one per dwelling unit in addition to a mailbox identification sign. (AR-1 §11-290D(1); FP §11-299E(1); VR §11-307D(1); C-1 §11-314E(7); C-2 §11-321E(7); PCD §11-328E(7))
- Sales or rental signs are limited to one per property, must not exceed six square feet for dwellings (larger limits for certain larger tracts and commercial properties), and must be removed within five days after execution of a contract for sale or lease. (AR-1 §11-290D(2); FP §11-299E(2); VR §11-307D(2); C-1 §11-314E(8); C-2 §11-321E(8); PCD §11-328E(8))
- Institutional freestanding signs are limited to one per property and may not exceed 24 square feet; wall sign area for institutions may not exceed 24 square feet. (AR-1 §11-290D(3); FP §11-299E(3); VR §11-307D(3); C-1 §11-314E(9); C-2 §11-321E(9); PCD §11-328E(9))
- Signs designating entrances or exits to or from a parking area are limited to one per entrance/exit with maximum four square feet per sign; one parking-area conditions/identity sign per parking area is limited to six square feet; private-driveway signs are limited to two square feet. (AR-1 §11-290D(4); FP §11-299E(4); VR §11-307D(4); C-1 §11-314E(10); C-2 §11-321E(10); PCD §11-328E(10))
- Signs may not be located closer to street rights-of-way than the minimum setback distances specified by sign area (e.g., 20 feet for signs under 25 square feet; larger setbacks for larger signs). (AR-1 §11-290D(5)(b); FP §11-299E(5)(b); VR §11-307D(5)(b); C-1 §11-314E(2); C-2 §11-321E(2); PCD §11-328E(2))
- All ground-sign areas must be kept neat, clean, landscaped, and maintained by the tenant/owner/occupant to which the sign applies. (AR-1 §11-290D(5)(c); FP §11-299E(5)(c); VR §11-307D(5)(c); C-1 §11-314E(3); C-2 §11-321E(3); PCD §11-328E(3))
- All signs must be kept in good repair, including structural components, faces, legibility, and functioning lighting elements. (AR-1 §11-290D(5)(e); FP §11-299E(5)(e); VR §11-307D(5)(e); C-1 §11-314E(11); C-2 §11-321E(11); PCD §11-328E(11))
- Nonconforming signs that are destroyed may not be replaced except in a conforming manner. (AR-1 §11-290D(5)(h); FP §11-299E(5)(h); VR §11-307D(5)(h); C-1 §11-314E(14); C-2 §11-321E(14); PCD §11-328E(14))
- Any location where business goods are no longer sold or services provided must remove remaining or derelict on‑premises signs within 60 days of Township notification, after which the Township may remove them at the owner’s expense. (AR-1 §11-290D(5)(f); FP §11-299E(5)(f); VR §11-307D(5)(f); C-1 §11-314E(12); C-2 §11-321E(12); PCD §11-328E(12))
- Whenever the Construction Official determines that a sign is structurally unsafe or endangers safety, it must be made safe or removed within 10 days of notice. (AR-1 §11-290D(5)(a); FP §11-299E(5)(a); VR §11-307D(5)(a); C-1 §11-314E(1); C-2 §11-321E(1); PCD §11-328E(1))
- The applicant must comply with all applicable county, state and federal sign regulations. (AR-1 §11-290D(5)(g); FP §11-299E(5)(g); VR §11-307D(5)(g); C-1 §11-314E(13); C-2 §11-321E(13); PCD §11-328E(13))
- Where a sign for a nonresidential use is directly adjacent to or across from a residential zone, the Approving Board may reduce the sign area by up to 10% and may require additional screening, light control and buffering. (AR-1 §11-290D(5)(i); FP §11-299E(5)(i); VR §11-307D(5)(i); C-1 §11-314E(15); C-2 §11-321E(15); PCD §11-328E(15))
Exempt Signs in Knowlton
- Directional signs with an area of less than three square feet are exempt from sign area and location regulations, but must be shown on an approved site plan and may not create a traffic hazard. (AR-1 §11-290D(5)(d); FP §11-299E(5)(d); VR §11-307D(5)(d); C-1 §11-314E(4); C-2 §11-321E(4); PCD §11-328E(4))
Sign Plan & Submission Notes for Knowlton
- For multi-use developments in the C‑1 Zone, a coordinated signing plan must be submitted to the Approving Board for approval, detailing letter style/height, lighting, color, construction/materials, height, placement, standards, and dimensions; signs must follow an integrated design theme; total sign area on a structure is limited to 3% of facade (up to 5% if approved). (C‑1 §11-314F)
- Freestanding signs for multi-use developments in the C‑1 Zone: one freestanding sign per property (a second may be allowed if there is access from more than one public street and no abutting residential use/zone); sign area not to exceed 5% of the building face fronting the street and in no case more than 80 square feet; located at least 40 feet from right‑of‑way or half the required front/rear yard, and must meet side-yard requirements. (C‑1 §11-314F(4))
- For multi-use developments in the C‑2 Zone, a signing plan must be submitted to the Approving Board and based on an integrated design theme; the plan must specify letter style/height, lighting, color, construction/materials, height, placement relative to grade/roofline, locations, standards and dimensions; total sign area on a structure limited to 3% of facade (Board may allow up to 5%). (C‑2 §11-321F)
- Freestanding signs for multi-use developments in the C‑2 Zone: one freestanding sign per property (possible second sign with more than one public-street access and no abutting residential use/zone); sign area up to 5% of the building face fronting the street but not more than 80 square feet; must be at least 40 feet from the right‑of‑way or half the required front/rear yard and comply with side-yard requirements. (C‑2 §11-321F(4))
- For multi-use developments in the PCD Zone, a signing plan must be submitted to the Approving Board, with details on letter style/height, lighting, color, construction/materials, height, elevation relative to grade/roofline, locations, standards and dimensions; the plan must implement an integrated sign theme; total sign area on a structure is limited to 3% of facade, with up to 5% permitted at the Board’s discretion. (PCD §11-328F)
- Freestanding signs for multi-use developments in the PCD Zone: one freestanding sign per property (second allowed if access from more than one public street and no abutting residential use/zone); sign area up to 5% of the building face fronting on the street, maximum 80 square feet; located at least 40 feet from right‑of‑way or half the required minimum front/rear yard, and must meet side-yard requirements. (PCD §11-328F(4))
- When more than one sign is proposed on a property in the C‑1, C‑2 or PCD Zones, a coordinated theme for all signs is required, which is typically implemented through a Board‑approved sign plan. (C‑1 §11-314E(18); C‑2 §11-321E(18); PCD §11-328E(18))
Source: ecode360 municipal code