Sign Regulations in Livingston Township, New Jersey
Livingston Township, New Jersey has specific sign regulations covering 35 sign types across 13 zoning districts. Regulated sign types include Wall Sign, Freestanding Sign, Entrance/Exit Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Livingston Township, New Jersey
Sample Sign Requirements in Livingston Township
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Professional or Nameplate Sign | Not listed | 2 square feet | Not listed |
| Subdivision Sign (Entrance) | Not listed | 30 square feet | See below; not closer than 1/2 the principal building setback. |
| Residential Districts Sign Setback Restriction | Not listed | Not listed | 1/2 the setback required for principal building. |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
35
- Wall Sign
- Freestanding Sign
- Entrance/Exit Sign
- Public Welfare Sign
- +2 more types
Zoning Districts
13
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Livingston Township
Other Cities in New Jersey
Frequently Asked Questions
In Livingston Township, the height limit for Freestanding Sign in the D-S2 Zone is 15 feet inc. supporting structure and ornament (Sec. 170-90K(3)). The height limit for Transition Lot Signs - Wall Sign in the R-1 District, R-2 District, R-3 District, R-4 District is 5 feet (as dimension) (Sec. 170-90A(6)(b)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Livingston Township require a permit. From the submission notes on this page: For certain sign types (e.g., in P-B1, P-B2, R-L, R-L2 Zones), the location, size, and arrangement of all signs permitted by the section must be shown on the site plan submitted to the Planning Board for its approval. Run a code check for an exact address to see the permit requirements for that zone.
Livingston Township's sign code covers 35 sign types, including Wall Sign, Freestanding Sign, Entrance/Exit Sign, and Public Welfare Sign. Most commercial signs need a permit. The ordinance lists 4 exemptions. One of them: Signs which are required by any provision of law may be located in any zone. The full list is on this page.
In Livingston Township, Freestanding Sign in the D-S2 Zone must be set back at least 20 ft from street right-of-way (Sec. 170-90K(3)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Livingston Township's sign ordinance that cover digital, changing, or flashing signs: Animated or changeable message signs are prohibited in all zone districts, unless part of a comprehensive sign package approved by the Planning Board (LED signs are prohibited unless otherwise specified). Any sign utilizing light-emitting diode (LED) technology is prohibited, except as permitted by §170-90C(8) or as part of a comprehensive sign package approved by the Planning Board. A comprehensive sign package approved by the Planning Board is required for any animated or changeable message signs (except LED signs, unless otherwise specified). Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Livingston Township Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Livingston Township, New Jersey, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Livingston Township, New Jersey Sign Rules at a Glance
Livingston Township, New Jersey regulates 35 sign types across 13 zoning districts. Transition Lot Signs - Freestanding in the R-1 District, R-2 District, R-3 District, R-4 District are capped at 6 feet above ground level and 5 square feet (Sec. 170-90A(6)(a)). Most commercial signs in Livingston Township require a permit.
Detailed Sign Ordinance Requirements for Livingston Township, New Jersey
Sign Rules by Zoning District in Livingston Township (13 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| R-1 District, R-2 District, R-3 District, R-4 District | 9 | 6 feet above ground level | 30 square feet | Not listed |
| R-6 Senior Citizen Housing District | 2 | Not listed | 30 square feet | Not listed |
| B Zone, B-1 Zone | 4 | Top: 20 feet above ground. Bottom: min 10 feet above ground. | 30 square feet (not including pole/pylon) | Not listed |
| B-2 District | 2 | 7 feet (top above ground); bottom at least 1 foot above ground. | 30 sq ft for text and logo per face; sign and structure max 40 sq ft per face. | Not listed |
| P-B Zone | 2 | 30 inches | 2 sq ft | Not listed |
| P-B1 Zone, P-B2 Zone | 3 | 12 feet | 10 sq ft (2.5 x 4 ft) | Not listed |
| D-S District | 3 | 20 feet | 300 sq ft | Not listed |
| R-L Zone, R-L2 Zone | 4 | 12 feet | 10 sq ft (2.5 x 4 ft) | Not listed |
| I Zone | 4 | 20 ft top, 10 ft bottom above ground. | 150 sq in | Not listed |
| D-S2 Zone | 7 | For signs facing Eisenhower Pkwy: ≤30 in (≤250 ft) / 36 in (250-550 ft) / 60 in (>550 ft); Executive Pkwy ≤36 in; Others ≤30 in. | 300 sq ft display area; structure/decoration may exceed (not specified). | Not listed |
| CI Commercial Industrial District | 2 | See formula (10% of setback or 15 ft, whichever greater) | 100 sq ft or 5% wall face area | Not listed |
| P-B3 Zone | 3 | 60 in | Not listed | Not listed |
| General Regulations For All Zones | 5 | 48 in | 36 in wide × 48 in high (std); max 6 sq ft per side, 24x36 in display area. | Not listed |
Zone-by-Zone Sign Requirements in Livingston Township(sample of 3 of 13 zones)
R-1 District, R-2 District, R-3 District, R-4 District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Professional or Nameplate Sign | Not listed | 2 square feet | Not listed | Not listed | 1 | On property, nameplate sign may be anywhere in front yard. | Not listed | Unlock | §170-90A(1) |
| Subdivision Sign (Entrance) | Not listed | 30 square feet | Not listed | See below; not closer than 1/2 the principal building setback. | Maximum 2 | At entrance(s) to tract. | Not listed | Unlock | §170-90A(2) |
| House of Worship Sign | Not listed | Not listed | Not listed | Not listed | Not listed | On premises of house of worship. | Not listed | Unlock | §170-90A(4) |
| Residential Districts Sign Setback Restriction | Not listed | Not listed | Not listed | 1/2 the setback required for principal building. | Not listed | Not listed | Not listed | Unlock | §170-90A(5) |
| Transition Lot Signs - Freestanding | 6 feet above ground level | 5 square feet | Not listed | Not listed | 1 | Not in front half of front yard or side street setback. | Not listed | Unlock | §170-90A(6)(a) |
| Transition Lot Signs - Wall Sign | 5 feet (as dimension) | Not listed | Not listed | Not listed | 1 | Front wall of building | Not listed | Unlock | §170-90A(6)(b) |
| Transition Lot Signs - Directory Wall Signs (All Entrances) | Not listed | 6 square feet | Not listed | Not listed | Not listed | At all entrances to the building | Not listed | Unlock | §170-90A(6)(c) |
| Contractor Sign (Temporary) | Not listed | 6 square feet | Not listed | At least 5 ft from any property boundary | 1 at a time; 2 per property per 365-day period | On property, set back at least 5 ft from any boundary line. | Not listed | Unlock | §170-90A(7) |
D-S2 Zone
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (Major/Anchor Tenant) | Not listed | Not listed | Not listed | Not listed | Max 2 per major/anchor tenant | Affixed to exterior wall facing street. | Not listed | Unlock | §170-90K(1) |
| Wall Sign (Other Tenant) | For signs facing Eisenhower Pkwy: ≤30 in (≤250 ft) / 36 in (250-550 ft) / 60 in (>550 ft); Executive Pkwy ≤36 in; Others ≤30 in. | Not listed | Not listed | Not listed | 1 per frontage/face | Not listed | Not listed | Unlock | §170-90K(1)(d) |
| Wall Sign (Single 5,000+ sq ft tenancy near Route 10 circle) | Eisenhower Parkway face: ≤5 ft 9 in; Southerly wall: ≤4 ft 6 in. Bottom of sign min 12 ft above grade. | Not listed | Not listed | Not listed | Not listed | Not listed | Not listed | Unlock | §170-90K(1)(f) |
| Freestanding Sign | 15 feet inc. supporting structure and ornament. | 300 sq ft display area; structure/decoration may exceed (not specified). | Not listed | 20 ft min to street ROW | 2 | No closer than 20 ft to street ROW | Not listed | Unlock | §170-90K(3) |
| Canopy Sign | Not listed | 3 sq ft | 36 inches | Not listed | 1 per tenant | In front of entrance (except for major/anchor tenants). | Not listed | Unlock | §170-90K(4) |
| Parking Area Entrance/Exit Sign | 6 feet (inc. supports) | 10 sq ft (2.5 x 4 ft) | 2.5 x 4 ft | Not listed | Not listed | Within 5 ft of ROW line | Not listed | Unlock | §170-90K(5) |
| Directional Sign | 6 feet (inc. supports) | 12 sq ft (4 x 3 ft) | 4 x 3 ft | Not listed | Not listed | Location as determined by Planning Board. | Not listed | Unlock | §170-90K(6) |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Real Estate For Sale/For Rent Sign | 5 ft overall for main sign; 6 ft overall for temporary business sign | 6 sq ft; open house rider 2 sq ft (rider) or 3 sq ft (additional sign); directionals 5 sq ft each | Not listed | ≥10 ft from curb/pavement | 1 sign per property; 2 directionals per open house | On property set back ≥10 ft from curb; directional may be on state/county main road within 0.25 mi, and local neighborhood. | Not listed | Unlock | §170-90M |
| Temporary New Development Sign | 8 ft if freestanding | 32 sq ft (less if street frontage <100 ft, then street frontage/100 × 32 sq ft) | Not listed | ≥10 ft if not affixed to principal building | One per street frontage | Affixed to building, poles/posts, or fence. If not on bldg, ≥10 ft setback. | Not listed | Unlock | §170-90Q |
| Political Sign | Not listed | Not listed | Not listed | Not listed | Not listed | May not be on public property more than 14 days after election (subject to runoff/contested exceptions). | Not listed | Unlock | §222-3 |
| Portable Sign (Sandwich Board) | 48 in | 36 in wide × 48 in high (std); max 6 sq ft per side, 24x36 in display area. | 36 in (P) / 30 in (BID) | Min 6 ft from curb; 4 ft pedestrian path must be clear. | 1 per building | Front yard of retail business, min 6 ft from curb; may be on sidewalk with ≥4 ft clearance. | Not listed | Unlock | §170-90P; §170-92J(3) |
| Temporary Window Sign (Commercial/Community Events) | Not listed | 9 sq ft or 25% of window glazing, whichever less | Not listed | Not listed | 1 per window | Front facade window (ground floor), commercial property | Not listed | Unlock | §170-92J(1)(b),(c),(2) |
PermitPal covers all 13 zoning districts in Livingston Township. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Livingston Township
- Billboards are prohibited in all zone districts.
- Beacons are prohibited in all zone districts.
- Flashing signs are prohibited in all zone districts.
- Neon signs are prohibited in all zone districts.
- Roof signs are prohibited in all zone districts.
- Vehicle signs are prohibited in all zone districts.
- Animated or changeable message signs are prohibited in all zone districts, unless part of a comprehensive sign package approved by the Planning Board (LED signs are prohibited unless otherwise specified).
- Any sign utilizing light-emitting diode (LED) technology is prohibited, except as permitted by §170-90C(8) or as part of a comprehensive sign package approved by the Planning Board.
- Any sign of such type, size or character, or placed at a location where it may distract the attention of a motorist so as to create potential threat to public welfare or safety or may endanger or injure public safety or health or pose a physical threat to property in its vicinity is prohibited.
- No sign shall be placed so as to interfere with or be mistaken for a traffic light or similar safety device or interfere with traffic visibility.
- Temporary and portable signs not expressly permitted are prohibited; as are all balloons, streamers, pinwheels or other devices that are capable of movement due to air flow and are not attached to a sign but have the effect of attracting attention to commercial activity.
- Graffiti (any drawing, painting or making of any mark or inscription on real or personal property without prior written permission of the property owner) is prohibited.
Exempt Signs in Livingston Township
- The prohibition of billboards and vehicle signs shall not be construed as prohibiting signs announcing, supporting or opposing a candidate for public office or taking a position on any political or public issue.
- Signs which are required by any provision of law may be located in any zone.
- Nothing in §170-92J is intended to prohibit noncommercial copy in the display area of a permitted sign.
- Legally erected signs in place on the date that subsection §170-90N becomes effective, or rebuilt as permitted therein, may continue to exist at their location if they meet property maintenance requirements, except for alteration, rebuild, relocation, enlargement, extension or replacement resulting in increased nonconformity.
Sign Plan & Submission Notes for Livingston Township
- A comprehensive sign package approved by the Planning Board is required for any animated or changeable message signs (except LED signs, unless otherwise specified).
- A comprehensive sign package approved by the Planning Board is required for any use of LED technology, except as permitted in §170-90C(8).
- For certain sign types (e.g., in P-B1, P-B2, R-L, R-L2 Zones), the location, size, and arrangement of all signs permitted by the section must be shown on the site plan submitted to the Planning Board for its approval.
- In the Special Improvement District (§170-92), all actions (including changes to or additions of signage) that require Township permits or Planning Board or Zoning Board of Adjustment determinations are first subject to application to, and prior review and action by, the Architectural Review Committee of the BID.
- Any monument sign for properties in the B and B-1 Zones as described in §170-90C(9) requires approval by the Minor Site Plan Committee of the Township Planning Board.
- Approval of the required application and payment of the required fee is required for temporary new development signs (see §170-90Q(1)).
- Portable sign applications must be made to the Zoning Officer and approved prior to display.
Source: ecode360 municipal code