Questions? Call us at (262) 218-2915

Sign Regulations in Albuquerque, New Mexico

Albuquerque, New Mexico has specific sign regulations covering 25 sign types across 7 zoning districts. Regulated sign types include Any Sign Type, Window Sign, Wall Sign (Low-density Residential). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: July 9, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Albuquerque, New Mexico

Sample Sign Requirements in Albuquerque

Sign TypeMax HeightMax AreaSetback
Wall Sign (Low-density Residential)Not listedR-A: 4 sq. ft.; R-1, R-T: 2 sq. ft.; R-ML, R-MH: 2 sq. ft.Not listed
Wall Sign (Multi-family Residential)Not listed24 sq. ft.Not listed
Yard SignNot listed2 sq. ft.Not listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for AlbuquerqueFull Coverage

Sign Types Covered

25

  • Any Sign Type
  • Window Sign
  • Wall Sign (Low-density Residential)
  • Wall Sign (Multi-family Residential)
  • +2 more types

Zoning Districts

7

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Albuquerque

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

In Albuquerque, the height limit for Freestanding Sign (NR-C, NR-LM, NR-GM) in the Non-residential Zone Districts (NR-C, NR-BP, NR-LM, NR-GM, NR-PO, NR-SU) is 26 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Albuquerque require a permit. From the submission notes on this page: In NR-BP, NR-SU, PD, or PC zone districts, off-premises signs are only allowed if maximum number, size, height, and location are specifically authorized in the EPC or City Council decision approving such zone district, including an associated Master Development Plan or Site Plan. Run a code check for an exact address to see the permit requirements for that zone.

Albuquerque's sign code covers 25 sign types, including Any Sign Type, Window Sign, Wall Sign (Low-density Residential), and Wall Sign (Multi-family Residential). Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Painting, cleaning, and other normal maintenance and repair of a sign or sign structure unless a structural change is made, shall not require a sign permit provided that they comply with the standards applicable to that type of sign in this IDO. The full list is on this page.

We haven't published Albuquerque's sign setback rules on this page yet. Run a code check for an exact address to see them.

Rules in Albuquerque's sign ordinance that cover digital, changing, or flashing signs: Electronic signs shall have only static messages and images; transition between messages/images on an electronic sign shall not exceed 1 second and shall not include any visual effects during that time. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Albuquerque Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Albuquerque, New Mexico, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Albuquerque, New Mexico Sign Rules at a Glance

Albuquerque, New Mexico regulates 25 sign types across 7 zoning districts. Monument Signs (Multi-family Residential) in the Residential Zone Districts (R-A, R-1, R-MC, R-T, R-ML, R-MH) are capped at 4 ft tall and 24 sq ft. Most commercial signs in Albuquerque require a permit.

Detailed Sign Ordinance Requirements for Albuquerque, New Mexico

Sign Rules by Zoning District in Albuquerque (7 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Residential Zone Districts (R-A, R-1, R-MC, R-T, R-ML, R-MH)66 ft. (Freestanding)24 sq. ft.Not listed
Mixed-use Zone Districts (MX-T, MX-L, MX-M, MX-H, MX-FB, MX-FB-ID, MX-FB-FX, MX-FB-AC, MX-FB-UD)11Letters/images may not exceed 18 in height.75 sq. ft.Not listed
Non-residential Zone Districts (NR-C, NR-BP, NR-LM, NR-GM, NR-PO, NR-SU)526 ft.100 sq. ft. (local or collector street); 200 sq. ft. (arterial/interstate); 300 sq. ft. (within 200 ft of through lane of interstate and visible)Not listed
Planned Development (PD)1Not listedPer approved Site Plan - EPC.Not listed
Planned Community (PC)1Not listedPer approved Framework Plan.Not listed
Overlay Zones1Not listedMay be set by Overlay (CPO/HPO/VPO).Not listed
General Regulations For All Zones37 ft.24 sq. ft.Not listed

Zone-by-Zone Sign Requirements in Albuquerque(sample of 3 of 7 zones)

Residential Zone Districts (R-A, R-1, R-MC, R-T, R-ML, R-MH)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Low-density Residential)Not listedR-A: 4 sq. ft.; R-1, R-T: 2 sq. ft.; R-ML, R-MH: 2 sq. ft.Not listedNot listed1 per dwellingOn the residential structure, only for a use accessory to the primary residential use; 1 per dwelling.Not listedUnlock14-16-5-12(F)(1) Table 5-12-2; 14-16-5-12(E)(5)(b)
Wall Sign (Multi-family Residential)Not listed24 sq. ft.Not listedNot listed1 per building per street frontage1 per building per street frontage.Not listedUnlock14-16-5-12(F)(1) Table 5-12-2
Yard SignNot listed2 sq. ft.Not listedNot listed1 per dwellingIn yard; 1 per dwelling in lieu of wall sign if dwelling is more than 30 ft. from street.Not listedUnlock14-16-5-12(F)(1) Table 5-12-2
Monument Sign (Multi-family Residential)4 ft.24 sq. ft.Not listedNot listed1 per street frontage (multi-family only)1 per street frontage serving multi-family development.Not listedUnlock14-16-5-12(F)(1) Table 5-12-2
Building-mounted or Freestanding Sign (Non-residential Uses in Residential Zone)6 ft. (Freestanding)24 sq. ft.Not listedNot listed1 per street frontage1 per street frontage.Not listedUnlock14-16-5-12(F)(1) Table 5-12-2
Window SignNot listedLimited to signs not discernible from public right-of-way (R-ML, R-MH); prohibited in R-A; not specified in others.Not listedNot listedNot listedOn windows; only in R-ML, R-MH zone districts, as long as not discernible from public right-of-way.Not listedUnlock14-16-5-12(F)(1) Table 5-12-2

Mixed-use Zone Districts (MX-T, MX-L, MX-M, MX-H, MX-FB, MX-FB-ID, MX-FB-FX, MX-FB-AC, MX-FB-UD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (MX-T, MX-FB-ID)Not listedNot listedNot listedNot listedN/A (not numerically limited by code)On building façade.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3
Wall Sign (MX-L)Not listedNot listedNot listedNot listedN/AOn building façade; not closer than 2 ft to edge of abutting frontage.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3
Canopy SignLetters/images may not exceed 18 in height.Not listed50% of building frontage width (MX-FB-AC, MX-FB-UD: full building frontage width)Not listed1 per establishment frontageOn vertical canopy surfacesNot listedUnlock14-16-5-12(F)(2) Table 5-12-3
Marquee Sign3 ft (MX-FB-AC, MX-FB-UD: 5 ft)Same as max wall sign for establishmentNot listedNot listed1 per theater or performance venue frontageProjection: 50% of the sidewalk width or 10 ft. from the facade, whichever is less.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3
Projecting SignNot listedSame as allowable size of freestanding sign.Projection: 30 in. from façade (different in special areas - see code)Not listed1 per establishmentOn building; over sidewalk or street.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3
Rooftop Sign (Small Areas Only)15 ft. or 25% of building height, whichever is less.75 sq. ft.Not listedNot listed1 per buildingOn building roof (restricted to mapped small areas)Not listedUnlock14-16-5-12(F)(3) Small Areas; 14-16-5-12(F)(2) Table 5-12-3
Freestanding Sign (by street frontage)MX-T, MX-FB-ID: 9 ft.; MX-L: 18 ft.; Other MX/NR-C/NR-LM/NR-GM: 26 ft.MX-T, MX-FB-ID: 50 sq. ft.; MX-L: 100 sq. ft.; Other MX/NR-C/NR-LM/NR-GM: 100 sq. ft. (local or collector), 200 sq. ft. (arterial or interstate), 300 sq. ft. (within 200 ft of through lane of interstate and visible).Not listedNot listed1 per premises per street frontageOn premises (1 per premises per street frontage) or on designated Joint Sign Premises.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3, 5-12(F)(2)(b), 5-12(F)(4)(a)
Portable Sign3 ft.6 sq. ft. per side, 2 sides max per sign.2.5 ft.Not listed1 per establishmentIn front of the establishment; may be in public right-of-way/sidewalk with clear widths.Not listedUnlock14-16-5-12(F)(4)(b) Table 5-12-4

Non-residential Zone Districts (NR-C, NR-BP, NR-LM, NR-GM, NR-PO, NR-SU)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (NR-C, NR-LM, NR-GM)Not listedNot listedNot listedNot listedN/AOn building façade.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3
Wall Sign (NR-BP, NR-SU, NR-PO)Not listedNot listedNot listedNot listedPer approved planAs shown on approved Master Development Plan or Site Plan EPC.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3
Freestanding Sign (NR-C, NR-LM, NR-GM)26 ft.100 sq. ft. (local or collector street); 200 sq. ft. (arterial/interstate); 300 sq. ft. (within 200 ft of through lane of interstate and visible)Not listedNot listed1 per premises per street frontageOn premises or Joint Sign Premises; 1 per premises per street frontage.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3, 14-16-5-12(F)(2)(b)
Freestanding Sign (NR-BP, NR-SU, NR-PO)Not listedPer approved plan.Not listedNot listedPer approved planAs specified in approved plan; 1 per premises per street frontage unless otherwise restricted.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3
Other Sign Types (NR-BP, NR-SU, NR-PO)Not listedPer approved plan.Not listedNot listedPer approved planPer approved plan.Not listedUnlock14-16-5-12(F)(2) Table 5-12-3

PermitPal covers all 7 zoning districts in Albuquerque. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Albuquerque

  • Any sign contributing to confusion of traffic control or resembling traffic control lighting; unauthorized sign, signal, marking, or device that purports to be or imitates official traffic control devices or railroad signs or signals; unauthorized sign that attempts to control traffic on any public right-of-way or private way; or sign that hides or interferes with the effectiveness of any official traffic control devices or any railroad signs or signals.
  • Any sign located in a clear sight triangle.
  • Any on-premises sign that advertises an activity, business, product, or service no longer produced or conducted on the premises upon which the sign is located for more than 30 calendar days after the vacancy or change of business that causes the sign to become inaccurate.
  • Any rotating, pulsating, or oscillating beacon of light; searchlight; or HID strobe light.
  • Any sign with an audible device.
  • No sign or part of a sign shall be located on any property without the consent of the owner, holder, lessee, agent, trustee, or other party controlling the use of such property.
  • Signs shall not be located within public waterline or sanitary sewer easements.
  • No sign may have overhead wiring to supply electric power, except for a freestanding off-premises sign where underground power cannot be accessed from the site.
  • Freestanding sign structures shall not use guy wires, bracing, or external supports.
  • Signs may not exceed applicable luminance limits and must have dimming controls, as specified in Tables 5-12-1 and 5-12-6.
  • Electronic signs shall have only static messages and images; transition between messages/images on an electronic sign shall not exceed 1 second and shall not include any visual effects during that time.
  • The failure to immediately cease demolition, development or land disturbance activity upon the discovery of an archaeological resource is a violation subject to penalties.

Exempt Signs in Albuquerque

  • The provisions of this Section 14-16-5-12 shall not apply to any sign erected or required to be erected by any State or federal governmental agency, or public utility provided that the size, height, location, type and illumination of the sign comply with these provisions to the maximum extent practicable, including compliance with the New Mexico Night Sky Protection Act, as regulated by the State.
  • Any sign legally erected before the effective date of this IDO that is no longer in compliance with the standards in this Section 14-16-5-12 may be retained in use, subject to the provisions of Subsection 14-16-6-8(F) (Nonconforming Signs).
  • Changing the advertising copy or message, including the interchange of the sign face, on an approved painted or printed sign structure or on a marquee or similar approved sign, provided that the size of the sign is not changed, shall not require a sign permit provided that they comply with the standards applicable to that type of sign in this IDO.
  • Painting, cleaning, and other normal maintenance and repair of a sign or sign structure unless a structural change is made, shall not require a sign permit provided that they comply with the standards applicable to that type of sign in this IDO.
  • Temporary signs may be erected without obtaining a sign permit, provided that they comply with the standards in Table 5-12-7.
  • Portable signs, when in compliance with Table 5-12-4, do not require a permit.
  • For signs in the public right-of-way, see Section 8-2-2-1 of ROA 1994 and the DPM.

Sign Plan & Submission Notes for Albuquerque

  • In NR-BP, NR-SU, PD, or PC zone districts, off-premises signs are only allowed if maximum number, size, height, and location are specifically authorized in the EPC or City Council decision approving such zone district, including an associated Master Development Plan or Site Plan.
  • Dimensional standards in NR-PO sub-zones shall be determined in the approval of a Master Plan, Natural Resource Management Plan, standards specified by the implementing Department, or standards appropriate to a Site Plan approval for a park or open space owned or managed by an entity other than the City.
  • Dimensional standards in NR-SU shall be determined in the approval of a Site Plan - EPC as part of the approval of a Zoning Map Amendment to the NR-SU zone district.
  • For lots 5 acres or greater adjacent to Major Public Open Space, an approved Site Plan - EPC is required prior to any platting action.
  • In the PD and NR-SU zone districts, and for development in any zone district on a site 5 acres or greater adjacent to Major Public Open Space, an approved Site Plan - EPC is required prior to any platting action.
  • In the NR-BP zone district, a Master Development Plan is required for lots 20 acres or more prior to platting action. For lots less than 20 acres zoned NR-BP, a Site Plan is required prior to development, but the property may be subdivided before or after a Site Plan is approved.
  • An Alternative Signage Plan is allowed on sites of at least 5 acres in Urban Centers within select zone districts, and must be reviewed and decided pursuant to Subsection 14-16-6-5(C)(2)(c) (Alternative Signage Plan).

Source: amlegal municipal code