Albuquerque, New Mexico has specific sign regulations covering 25 sign types across 7 zoning districts. Regulated sign types include Any Sign Type, Window Sign, Wall Sign (Low-density Residential). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: July 9, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Albuquerque, New Mexico
Sample Sign Requirements in Albuquerque
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Wall Sign (Low-density Residential) | Not listed | R-A: 4 sq. ft.; R-1, R-T: 2 sq. ft.; R-ML, R-MH: 2 sq. ft. | Not listed |
| Wall Sign (Multi-family Residential) | Not listed | 24 sq. ft. | Not listed |
| Yard Sign | Not listed | 2 sq. ft. | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
25
- Any Sign Type
- Window Sign
- Wall Sign (Low-density Residential)
- Wall Sign (Multi-family Residential)
- +2 more types
Zoning Districts
7
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Albuquerque
Other Cities in New Mexico
Frequently Asked Questions
In Albuquerque, the height limit for Freestanding Sign (NR-C, NR-LM, NR-GM) in the Non-residential Zone Districts (NR-C, NR-BP, NR-LM, NR-GM, NR-PO, NR-SU) is 26 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Albuquerque require a permit. From the submission notes on this page: In NR-BP, NR-SU, PD, or PC zone districts, off-premises signs are only allowed if maximum number, size, height, and location are specifically authorized in the EPC or City Council decision approving such zone district, including an associated Master Development Plan or Site Plan. Run a code check for an exact address to see the permit requirements for that zone.
Albuquerque's sign code covers 25 sign types, including Any Sign Type, Window Sign, Wall Sign (Low-density Residential), and Wall Sign (Multi-family Residential). Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Painting, cleaning, and other normal maintenance and repair of a sign or sign structure unless a structural change is made, shall not require a sign permit provided that they comply with the standards applicable to that type of sign in this IDO. The full list is on this page.
We haven't published Albuquerque's sign setback rules on this page yet. Run a code check for an exact address to see them.
Rules in Albuquerque's sign ordinance that cover digital, changing, or flashing signs: Electronic signs shall have only static messages and images; transition between messages/images on an electronic sign shall not exceed 1 second and shall not include any visual effects during that time. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Albuquerque Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Albuquerque, New Mexico, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Albuquerque, New Mexico Sign Rules at a Glance
Albuquerque, New Mexico regulates 25 sign types across 7 zoning districts. Monument Signs (Multi-family Residential) in the Residential Zone Districts (R-A, R-1, R-MC, R-T, R-ML, R-MH) are capped at 4 ft tall and 24 sq ft. Most commercial signs in Albuquerque require a permit.
Detailed Sign Ordinance Requirements for Albuquerque, New Mexico
Sign Rules by Zoning District in Albuquerque (7 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Residential Zone Districts (R-A, R-1, R-MC, R-T, R-ML, R-MH) | 6 | 6 ft. (Freestanding) | 24 sq. ft. | Not listed |
| Mixed-use Zone Districts (MX-T, MX-L, MX-M, MX-H, MX-FB, MX-FB-ID, MX-FB-FX, MX-FB-AC, MX-FB-UD) | 11 | Letters/images may not exceed 18 in height. | 75 sq. ft. | Not listed |
| Non-residential Zone Districts (NR-C, NR-BP, NR-LM, NR-GM, NR-PO, NR-SU) | 5 | 26 ft. | 100 sq. ft. (local or collector street); 200 sq. ft. (arterial/interstate); 300 sq. ft. (within 200 ft of through lane of interstate and visible) | Not listed |
| Planned Development (PD) | 1 | Not listed | Per approved Site Plan - EPC. | Not listed |
| Planned Community (PC) | 1 | Not listed | Per approved Framework Plan. | Not listed |
| Overlay Zones | 1 | Not listed | May be set by Overlay (CPO/HPO/VPO). | Not listed |
| General Regulations For All Zones | 3 | 7 ft. | 24 sq. ft. | Not listed |
Zone-by-Zone Sign Requirements in Albuquerque(sample of 3 of 7 zones)
Residential Zone Districts (R-A, R-1, R-MC, R-T, R-ML, R-MH)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (Low-density Residential) | Not listed | R-A: 4 sq. ft.; R-1, R-T: 2 sq. ft.; R-ML, R-MH: 2 sq. ft. | Not listed | Not listed | 1 per dwelling | On the residential structure, only for a use accessory to the primary residential use; 1 per dwelling. | Not listed | Unlock | 14-16-5-12(F)(1) Table 5-12-2; 14-16-5-12(E)(5)(b) |
| Wall Sign (Multi-family Residential) | Not listed | 24 sq. ft. | Not listed | Not listed | 1 per building per street frontage | 1 per building per street frontage. | Not listed | Unlock | 14-16-5-12(F)(1) Table 5-12-2 |
| Yard Sign | Not listed | 2 sq. ft. | Not listed | Not listed | 1 per dwelling | In yard; 1 per dwelling in lieu of wall sign if dwelling is more than 30 ft. from street. | Not listed | Unlock | 14-16-5-12(F)(1) Table 5-12-2 |
| Monument Sign (Multi-family Residential) | 4 ft. | 24 sq. ft. | Not listed | Not listed | 1 per street frontage (multi-family only) | 1 per street frontage serving multi-family development. | Not listed | Unlock | 14-16-5-12(F)(1) Table 5-12-2 |
| Building-mounted or Freestanding Sign (Non-residential Uses in Residential Zone) | 6 ft. (Freestanding) | 24 sq. ft. | Not listed | Not listed | 1 per street frontage | 1 per street frontage. | Not listed | Unlock | 14-16-5-12(F)(1) Table 5-12-2 |
| Window Sign | Not listed | Limited to signs not discernible from public right-of-way (R-ML, R-MH); prohibited in R-A; not specified in others. | Not listed | Not listed | Not listed | On windows; only in R-ML, R-MH zone districts, as long as not discernible from public right-of-way. | Not listed | Unlock | 14-16-5-12(F)(1) Table 5-12-2 |
Mixed-use Zone Districts (MX-T, MX-L, MX-M, MX-H, MX-FB, MX-FB-ID, MX-FB-FX, MX-FB-AC, MX-FB-UD)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (MX-T, MX-FB-ID) | Not listed | Not listed | Not listed | Not listed | N/A (not numerically limited by code) | On building façade. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3 |
| Wall Sign (MX-L) | Not listed | Not listed | Not listed | Not listed | N/A | On building façade; not closer than 2 ft to edge of abutting frontage. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3 |
| Canopy Sign | Letters/images may not exceed 18 in height. | Not listed | 50% of building frontage width (MX-FB-AC, MX-FB-UD: full building frontage width) | Not listed | 1 per establishment frontage | On vertical canopy surfaces | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3 |
| Marquee Sign | 3 ft (MX-FB-AC, MX-FB-UD: 5 ft) | Same as max wall sign for establishment | Not listed | Not listed | 1 per theater or performance venue frontage | Projection: 50% of the sidewalk width or 10 ft. from the facade, whichever is less. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3 |
| Projecting Sign | Not listed | Same as allowable size of freestanding sign. | Projection: 30 in. from façade (different in special areas - see code) | Not listed | 1 per establishment | On building; over sidewalk or street. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3 |
| Rooftop Sign (Small Areas Only) | 15 ft. or 25% of building height, whichever is less. | 75 sq. ft. | Not listed | Not listed | 1 per building | On building roof (restricted to mapped small areas) | Not listed | Unlock | 14-16-5-12(F)(3) Small Areas; 14-16-5-12(F)(2) Table 5-12-3 |
| Freestanding Sign (by street frontage) | MX-T, MX-FB-ID: 9 ft.; MX-L: 18 ft.; Other MX/NR-C/NR-LM/NR-GM: 26 ft. | MX-T, MX-FB-ID: 50 sq. ft.; MX-L: 100 sq. ft.; Other MX/NR-C/NR-LM/NR-GM: 100 sq. ft. (local or collector), 200 sq. ft. (arterial or interstate), 300 sq. ft. (within 200 ft of through lane of interstate and visible). | Not listed | Not listed | 1 per premises per street frontage | On premises (1 per premises per street frontage) or on designated Joint Sign Premises. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3, 5-12(F)(2)(b), 5-12(F)(4)(a) |
| Portable Sign | 3 ft. | 6 sq. ft. per side, 2 sides max per sign. | 2.5 ft. | Not listed | 1 per establishment | In front of the establishment; may be in public right-of-way/sidewalk with clear widths. | Not listed | Unlock | 14-16-5-12(F)(4)(b) Table 5-12-4 |
Non-residential Zone Districts (NR-C, NR-BP, NR-LM, NR-GM, NR-PO, NR-SU)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (NR-C, NR-LM, NR-GM) | Not listed | Not listed | Not listed | Not listed | N/A | On building façade. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3 |
| Wall Sign (NR-BP, NR-SU, NR-PO) | Not listed | Not listed | Not listed | Not listed | Per approved plan | As shown on approved Master Development Plan or Site Plan EPC. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3 |
| Freestanding Sign (NR-C, NR-LM, NR-GM) | 26 ft. | 100 sq. ft. (local or collector street); 200 sq. ft. (arterial/interstate); 300 sq. ft. (within 200 ft of through lane of interstate and visible) | Not listed | Not listed | 1 per premises per street frontage | On premises or Joint Sign Premises; 1 per premises per street frontage. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3, 14-16-5-12(F)(2)(b) |
| Freestanding Sign (NR-BP, NR-SU, NR-PO) | Not listed | Per approved plan. | Not listed | Not listed | Per approved plan | As specified in approved plan; 1 per premises per street frontage unless otherwise restricted. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3 |
| Other Sign Types (NR-BP, NR-SU, NR-PO) | Not listed | Per approved plan. | Not listed | Not listed | Per approved plan | Per approved plan. | Not listed | Unlock | 14-16-5-12(F)(2) Table 5-12-3 |
PermitPal covers all 7 zoning districts in Albuquerque. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Albuquerque
- Any sign contributing to confusion of traffic control or resembling traffic control lighting; unauthorized sign, signal, marking, or device that purports to be or imitates official traffic control devices or railroad signs or signals; unauthorized sign that attempts to control traffic on any public right-of-way or private way; or sign that hides or interferes with the effectiveness of any official traffic control devices or any railroad signs or signals.
- Any sign located in a clear sight triangle.
- Any on-premises sign that advertises an activity, business, product, or service no longer produced or conducted on the premises upon which the sign is located for more than 30 calendar days after the vacancy or change of business that causes the sign to become inaccurate.
- Any rotating, pulsating, or oscillating beacon of light; searchlight; or HID strobe light.
- Any sign with an audible device.
- No sign or part of a sign shall be located on any property without the consent of the owner, holder, lessee, agent, trustee, or other party controlling the use of such property.
- Signs shall not be located within public waterline or sanitary sewer easements.
- No sign may have overhead wiring to supply electric power, except for a freestanding off-premises sign where underground power cannot be accessed from the site.
- Freestanding sign structures shall not use guy wires, bracing, or external supports.
- Signs may not exceed applicable luminance limits and must have dimming controls, as specified in Tables 5-12-1 and 5-12-6.
- Electronic signs shall have only static messages and images; transition between messages/images on an electronic sign shall not exceed 1 second and shall not include any visual effects during that time.
- The failure to immediately cease demolition, development or land disturbance activity upon the discovery of an archaeological resource is a violation subject to penalties.
Exempt Signs in Albuquerque
- The provisions of this Section 14-16-5-12 shall not apply to any sign erected or required to be erected by any State or federal governmental agency, or public utility provided that the size, height, location, type and illumination of the sign comply with these provisions to the maximum extent practicable, including compliance with the New Mexico Night Sky Protection Act, as regulated by the State.
- Any sign legally erected before the effective date of this IDO that is no longer in compliance with the standards in this Section 14-16-5-12 may be retained in use, subject to the provisions of Subsection 14-16-6-8(F) (Nonconforming Signs).
- Changing the advertising copy or message, including the interchange of the sign face, on an approved painted or printed sign structure or on a marquee or similar approved sign, provided that the size of the sign is not changed, shall not require a sign permit provided that they comply with the standards applicable to that type of sign in this IDO.
- Painting, cleaning, and other normal maintenance and repair of a sign or sign structure unless a structural change is made, shall not require a sign permit provided that they comply with the standards applicable to that type of sign in this IDO.
- Temporary signs may be erected without obtaining a sign permit, provided that they comply with the standards in Table 5-12-7.
- Portable signs, when in compliance with Table 5-12-4, do not require a permit.
- For signs in the public right-of-way, see Section 8-2-2-1 of ROA 1994 and the DPM.
Sign Plan & Submission Notes for Albuquerque
- In NR-BP, NR-SU, PD, or PC zone districts, off-premises signs are only allowed if maximum number, size, height, and location are specifically authorized in the EPC or City Council decision approving such zone district, including an associated Master Development Plan or Site Plan.
- Dimensional standards in NR-PO sub-zones shall be determined in the approval of a Master Plan, Natural Resource Management Plan, standards specified by the implementing Department, or standards appropriate to a Site Plan approval for a park or open space owned or managed by an entity other than the City.
- Dimensional standards in NR-SU shall be determined in the approval of a Site Plan - EPC as part of the approval of a Zoning Map Amendment to the NR-SU zone district.
- For lots 5 acres or greater adjacent to Major Public Open Space, an approved Site Plan - EPC is required prior to any platting action.
- In the PD and NR-SU zone districts, and for development in any zone district on a site 5 acres or greater adjacent to Major Public Open Space, an approved Site Plan - EPC is required prior to any platting action.
- In the NR-BP zone district, a Master Development Plan is required for lots 20 acres or more prior to platting action. For lots less than 20 acres zoned NR-BP, a Site Plan is required prior to development, but the property may be subdivided before or after a Site Plan is approved.
- An Alternative Signage Plan is allowed on sites of at least 5 acres in Urban Centers within select zone districts, and must be reviewed and decided pursuant to Subsection 14-16-6-5(C)(2)(c) (Alternative Signage Plan).
Source: amlegal municipal code