Questions? Call us at (262) 218-2915

Sign Regulations in Croton-on-Hudson, New York

Croton-on-Hudson, New York has specific sign regulations covering 32 sign types across 9 zoning districts. Regulated sign types include Wall Sign, Wall Sign (All Facades), Freestanding Sign (>=25 ft setback). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 28, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Croton-on-Hudson, New York

Sample Sign Requirements in Croton-on-Hudson

Sign TypeMax HeightMax AreaSetback
Temporary Sign - For Sale, For Rent, SoldNot listed6 sq ft each (single lot); 16 sq ft each (real estate subdivision)Subdivision sign: min. 15 ft from street line
Temporary Sign - ConstructionNot listed6 sq ftNot listed
Temporary Sign - Election CampaignNot listed16 sq ftNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Croton-on-HudsonFull Coverage

Sign Types Covered

32

  • Wall Sign
  • Wall Sign (All Facades)
  • Freestanding Sign (>=25 ft setback)
  • Freestanding Sign (15-25 ft setback) (Special Permit)
  • +2 more types

Zoning Districts

9

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Frequently Asked Questions

In Croton-on-Hudson, the height limit for Freestanding Sign (General) is 10 ft (Sec. 230-44L). Maximum sign heights range from 8 ft to 42 inches (3.5 ft) across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Croton-on-Hudson require a permit. From the submission notes on this page: All signage applications (except temporary signs and certain residential yard signs) are reviewed by the Village Engineer, Visual Environment Board (VEB), and, as appropriate, the Planning Board. Run a code check for an exact address to see the permit requirements for that zone.

Croton-on-Hudson's sign code covers 32 sign types, including Wall Sign, Wall Sign (All Facades), Freestanding Sign (>=25 ft setback), and Freestanding Sign (15-25 ft setback) (Special Permit). Most commercial signs need a permit. The ordinance lists 5 exemptions. One of them: Temporary signs do not require a signage permit (subject to restrictions and duration limits as set forth in Subsection K). The full list is on this page.

In Croton-on-Hudson, Freestanding Sign (>=25 ft setback) in the Central Commercial (C-1) and other zoning districts must be set back at least 25 ft from curbline. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Croton-on-Hudson's sign ordinance that cover digital, changing, or flashing signs: Sign illumination shall not be twinkling, flashing, intermittent (except for time/temperature signs), or of changing degrees of color or intensity. No sign or sign component shall be moving, animated, rotating or revolving. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Croton-on-Hudson Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Croton-on-Hudson, New York, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Croton-on-Hudson, New York Sign Rules at a Glance

Croton-on-Hudson, New York regulates 32 sign types across 9 zoning districts. Freestanding Signs (>=25 ft setback) in the General Commercial (C-2) zoning district are capped at 40 sq ft per face, set back at least 25 ft from curbline. Most commercial signs in Croton-on-Hudson require a permit.

Detailed Sign Ordinance Requirements for Croton-on-Hudson, New York

Sign Rules by Zoning District in Croton-on-Hudson (9 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones910 ft25% of any given windowNot listed
One-Family Residence (RA-60, RA-40, RA-25, RA-9, RA-5), Two-Family Residence (RB), Multiple Residence (RC)442 inches (3.5 ft)12 sq ftNot listed
Limited Office (O-1)1Not listed5 sq ftNot listed
Limited Office (O-2)1Not listedNot greater than 1.5 × length of wall in feetNot listed
Central Commercial (C-1), Riverside Commercial (C-1R(A)), Riverside Transition (C-1R(B))6Not listed180 sq in (12 in x 15 in) per signNot listed
General Commercial (C-2)8Not listed180 sq in (12 in x 15 in) per signNot listed
Light Industrial (LI)38 ft50 sq ft or 1.5 × wall length (ft), whichever is lessNot listed
Waterfront Commercial (WC)210 ft30 sq ft or 1.5 × wall length (ft), whichever is lessNot listed
Waterfront Development (WD)410 ft24 sq ftNot listed

Zone-by-Zone Sign Requirements in Croton-on-Hudson(sample of 3 of 9 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Temporary Sign - For Sale, For Rent, SoldNot listed6 sq ft each (single lot); 16 sq ft each (real estate subdivision)Not listedSubdivision sign: min. 15 ft from street lineMax 2 per lot; 1 per real estate subdivisionOn lot for sale/rent/soldNot listedUnlock230-44K(2)(a), 230-44K(4), 230-44K(5)
Temporary Sign - ConstructionNot listed6 sq ftNot listedNot listedOne per architect, engineer, contractorAt construction siteNot listedUnlock230-44K(2)(b), 230-44K(4), 230-44K(5)
Temporary Sign - Election CampaignNot listed16 sq ftNot listedNot listedNot listedOn private propertyNot listedUnlock230-44K(2)(c), 230-44K(4), 230-44K(5)
Temporary Sign - Civic, Philanthropic, Educational, Religious EventsNot listedNot listedNot listedNot listedNot listedOn property of institutionNot listedUnlock230-44K(2)(e), 230-44K(4), 230-44K(5)
Temporary Sign - Garage Sales, Tag Sales, Short-term Business ActivitiesNot listed16 sq ftNot listedNot listedNot listedOn property of such sale/activityNot listedUnlock230-44K(2)(d), 230-44K(4), 230-44K(5)
Freestanding Sign (General)10 ftNot listedNot listedNot listedNot listedNot listedNot listedUnlock230-44L
Projecting SignNot listedNot listedNot listedNot listedNot listedProjecting from buildingNot listedUnlock230-44J
Window Sign (Permanent)Not listed25% of any given windowNot listedNot listedNot listedApplied to or within 2 ft of window interiorNot listedUnlock230-44O

Central Commercial (C-1), Riverside Commercial (C-1R(A)), Riverside Transition (C-1R(B))

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (All Facades)Not listedNot greater than 2× length of wall in feetNot listedNot listedOne per tenant per street facadeEach facade fronting a streetNot listedUnlock230-44P(4)(a)[1-3]
Freestanding Sign (>=25 ft setback)Not listed40 sq ft per faceNot listedMin. 25 ft from curbline1Where building set back ≥ 25 ft from curblineNot listedUnlock230-44P(4)(a)[4]
Freestanding Sign (15-25 ft setback) (Special Permit)Not listedUp to 40 sq ft per face or lesser as prescribed by ZBANot listedMin. 15 ft and <25 ft from curbline/edge1Where building set back 15-25 ft from curb/edgeNot listedUnlock230-44P(4)(a)[4]
Wall Sign (Service Stations)Not listedNot listedNot listedNot listedOne per wall per street + one freestandingOn each wall fronting a streetNot listedUnlock230-44P(4)(b)[1]
Freestanding Sign (Service Stations)Not listedNot listedNot listedNot listed1On service station propertyNot listedUnlock230-44P(4)(b)[1]
Vehicle Window Sign (Interior)Not listed180 sq in (12 in x 15 in) per signNot listedNot listed1 per vehicleInterior of vehicleNot listedUnlock230-44P(4)(b)[2]

General Commercial (C-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (All Facades)Not listedNot greater than 2× length of wall in feetNot listedNot listedOne per tenant per street facadeEach facade fronting a streetNot listedUnlock230-44P(5)(a) via P(4)
Freestanding Sign (>=25 ft setback)Not listed40 sq ft per faceNot listedMin. 25 ft from curbline1Where building set back ≥ 25 ft from curblineNot listedUnlock230-44P(5)(a) via P(4)
Freestanding Sign (15-25 ft setback) (Special Permit)Not listedUp to 40 sq ft per face or lesser as prescribed by ZBANot listedMin. 15 ft and <25 ft from curbline/edge1Where building set back 15-25 ft from curb/edgeNot listedUnlock230-44P(5)(a) via P(4)
Wall Sign (Service Stations & Auto Sales)Not listedNot listedNot listedNot listedOne per wall per street + one freestandingOn each wall fronting a streetNot listedUnlock230-44P(5)(c)[1]
Freestanding Sign (Service Stations & Auto Sales)Not listedNot listedNot listedNot listed1On lotNot listedUnlock230-44P(5)(c)[1]
Vehicle Window Sign (Interior)Not listed180 sq in (12 in x 15 in) per signNot listedNot listed1 per vehicleInterior of vehicleNot listedUnlock230-44P(5)(c)[2]
Drive-in Theater Signs - Theater NameNot listedNot listedNot listedNot listed1Affixed to reverse side of theater screen structureNot listedUnlock230-44P(5)(b)[1]
Drive-in Theater Signs - SupplementaryNot listedNot listedNot listedNot listed1 per feature/announcementOn same face as theater name signNot listedUnlock230-44P(5)(b)[2]

PermitPal covers all 9 zoning districts in Croton-on-Hudson. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Croton-on-Hudson

  • No sign shall be erected, replaced, moved or modified except in conformity with the provisions of this chapter.
  • All signs, except for temporary signs and certain billboards, must pertain to a use conducted on the same property on which the sign is located.
  • Sign illumination shall not be twinkling, flashing, intermittent (except for time/temperature signs), or of changing degrees of color or intensity.
  • No sign shall contain or consist of Day-Glo-like material.
  • No light source used for illuminating signage shall be a source of glare.
  • No sign shall be located so as to obscure any signs displayed by a public authority.
  • No sign shall be placed in such a way as to obstruct proper vehicular sight distance.
  • No sign shall interfere with pedestrian or vehicular traffic flow.
  • No sign shall interfere with any ventilation system, door, window, fire escape or other emergency exit.
  • No sign or sign component shall be moving, animated, rotating or revolving.
  • No sign shall contain removable letters, except for signs associated with educational, religious, or municipal institutions, gas stations, or movie theaters.
  • Light strips and strings of lights shall not be used for advertising or attracting attention to a sign when they do not comprise the text of the sign.
  • All signs must be kept in good repair and in safe, neat and clean condition.
  • All signs and related illumination shall be of a professional quality (except as exempted).
  • Marquee signs are permitted for theaters only.
  • Projecting signs must not project vertically above the roofline or parapet, or extend horizontally beyond the limits of the building.
  • Billboards are prohibited except for those existing on the effective date associated with a site on the National Register of Historic Places.
  • Signs that compete for attention with or may be mistaken for a traffic signal are prohibited.
  • Searchlights, beacons, blimps, and permanent balloons are prohibited.
  • Signs attached to or painted on trucks or other large vehicles, when obviously marked and parked to advertise or attract attention, are prohibited.
  • Banners, flags, strings of balloons, flags or lights, or similar outdoor advertising are prohibited except on a temporary basis with respect to the opening, reopening, or remodeling of the business (maximum duration of 45 days).

Exempt Signs in Croton-on-Hudson

  • Temporary signs do not require a signage permit (subject to restrictions and duration limits as set forth in Subsection K).
  • Temporary signs must conform with all other provisions of the chapter except with respect to being of a professional quality (Subsection H).
  • Residential yard signs (up to three, nonilluminated, each not exceeding six square feet and no higher than 42 inches above existing ground surface) do not require professional quality as required in Subsection H.
  • Nonconforming billboards that existed on the effective date of these regulations are exempt if associated with a site on the National Register of Historic Places.
  • Certain temporary signs (real estate, construction, election, garage/tag sales, civic/educational/religious events) are exempt from permit and/or standard limits, as detailed in Subsection K.

Sign Plan & Submission Notes for Croton-on-Hudson

  • All signage applications (except temporary signs and certain residential yard signs) are reviewed by the Village Engineer, Visual Environment Board (VEB), and, as appropriate, the Planning Board.
  • If signage is part of a site plan approval or a change of use approval, the Planning Board's decision on the site plan shall include its decision on the proposed signage.
  • The Planning Board may require the submission of an illumination plan for illuminated signage.
  • Where a building or site is permitted more than one sign by the provisions of this chapter, all new signs shall be consistent relative to one another in terms of size, shape, and location. Further, the Planning Board may require the submission of a master signage plan for the site which shows such consistency.
  • The Planning Board may require a master signage plan as per Subsection N.
  • For Waterfront Development districts, the Planning Board may require signage details as part of the site development plan review process.
  • Modifications to sign requirements may be granted by the Planning Board, who may attach conditions to any such approval.