Croton-on-Hudson, New York has specific sign regulations covering 32 sign types across 9 zoning districts. Regulated sign types include Wall Sign, Wall Sign (All Facades), Freestanding Sign (>=25 ft setback). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Croton-on-Hudson, New York
Sample Sign Requirements in Croton-on-Hudson
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Temporary Sign - For Sale, For Rent, Sold | Not listed | 6 sq ft each (single lot); 16 sq ft each (real estate subdivision) | Subdivision sign: min. 15 ft from street line |
| Temporary Sign - Construction | Not listed | 6 sq ft | Not listed |
| Temporary Sign - Election Campaign | Not listed | 16 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
32
- Wall Sign
- Wall Sign (All Facades)
- Freestanding Sign (>=25 ft setback)
- Freestanding Sign (15-25 ft setback) (Special Permit)
- +2 more types
Zoning Districts
9
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Other Cities in New York
Frequently Asked Questions
In Croton-on-Hudson, the height limit for Freestanding Sign (General) is 10 ft (Sec. 230-44L). Maximum sign heights range from 8 ft to 42 inches (3.5 ft) across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Croton-on-Hudson require a permit. From the submission notes on this page: All signage applications (except temporary signs and certain residential yard signs) are reviewed by the Village Engineer, Visual Environment Board (VEB), and, as appropriate, the Planning Board. Run a code check for an exact address to see the permit requirements for that zone.
Croton-on-Hudson's sign code covers 32 sign types, including Wall Sign, Wall Sign (All Facades), Freestanding Sign (>=25 ft setback), and Freestanding Sign (15-25 ft setback) (Special Permit). Most commercial signs need a permit. The ordinance lists 5 exemptions. One of them: Temporary signs do not require a signage permit (subject to restrictions and duration limits as set forth in Subsection K). The full list is on this page.
In Croton-on-Hudson, Freestanding Sign (>=25 ft setback) in the Central Commercial (C-1) and other zoning districts must be set back at least 25 ft from curbline. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Croton-on-Hudson's sign ordinance that cover digital, changing, or flashing signs: Sign illumination shall not be twinkling, flashing, intermittent (except for time/temperature signs), or of changing degrees of color or intensity. No sign or sign component shall be moving, animated, rotating or revolving. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Croton-on-Hudson Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Croton-on-Hudson, New York, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Croton-on-Hudson, New York Sign Rules at a Glance
Croton-on-Hudson, New York regulates 32 sign types across 9 zoning districts. Freestanding Signs (>=25 ft setback) in the General Commercial (C-2) zoning district are capped at 40 sq ft per face, set back at least 25 ft from curbline. Most commercial signs in Croton-on-Hudson require a permit.
Detailed Sign Ordinance Requirements for Croton-on-Hudson, New York
Sign Rules by Zoning District in Croton-on-Hudson (9 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 9 | 10 ft | 25% of any given window | Not listed |
| One-Family Residence (RA-60, RA-40, RA-25, RA-9, RA-5), Two-Family Residence (RB), Multiple Residence (RC) | 4 | 42 inches (3.5 ft) | 12 sq ft | Not listed |
| Limited Office (O-1) | 1 | Not listed | 5 sq ft | Not listed |
| Limited Office (O-2) | 1 | Not listed | Not greater than 1.5 × length of wall in feet | Not listed |
| Central Commercial (C-1), Riverside Commercial (C-1R(A)), Riverside Transition (C-1R(B)) | 6 | Not listed | 180 sq in (12 in x 15 in) per sign | Not listed |
| General Commercial (C-2) | 8 | Not listed | 180 sq in (12 in x 15 in) per sign | Not listed |
| Light Industrial (LI) | 3 | 8 ft | 50 sq ft or 1.5 × wall length (ft), whichever is less | Not listed |
| Waterfront Commercial (WC) | 2 | 10 ft | 30 sq ft or 1.5 × wall length (ft), whichever is less | Not listed |
| Waterfront Development (WD) | 4 | 10 ft | 24 sq ft | Not listed |
Zone-by-Zone Sign Requirements in Croton-on-Hudson(sample of 3 of 9 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Temporary Sign - For Sale, For Rent, Sold | Not listed | 6 sq ft each (single lot); 16 sq ft each (real estate subdivision) | Not listed | Subdivision sign: min. 15 ft from street line | Max 2 per lot; 1 per real estate subdivision | On lot for sale/rent/sold | Not listed | Unlock | 230-44K(2)(a), 230-44K(4), 230-44K(5) |
| Temporary Sign - Construction | Not listed | 6 sq ft | Not listed | Not listed | One per architect, engineer, contractor | At construction site | Not listed | Unlock | 230-44K(2)(b), 230-44K(4), 230-44K(5) |
| Temporary Sign - Election Campaign | Not listed | 16 sq ft | Not listed | Not listed | Not listed | On private property | Not listed | Unlock | 230-44K(2)(c), 230-44K(4), 230-44K(5) |
| Temporary Sign - Civic, Philanthropic, Educational, Religious Events | Not listed | Not listed | Not listed | Not listed | Not listed | On property of institution | Not listed | Unlock | 230-44K(2)(e), 230-44K(4), 230-44K(5) |
| Temporary Sign - Garage Sales, Tag Sales, Short-term Business Activities | Not listed | 16 sq ft | Not listed | Not listed | Not listed | On property of such sale/activity | Not listed | Unlock | 230-44K(2)(d), 230-44K(4), 230-44K(5) |
| Freestanding Sign (General) | 10 ft | Not listed | Not listed | Not listed | Not listed | Not listed | Not listed | Unlock | 230-44L |
| Projecting Sign | Not listed | Not listed | Not listed | Not listed | Not listed | Projecting from building | Not listed | Unlock | 230-44J |
| Window Sign (Permanent) | Not listed | 25% of any given window | Not listed | Not listed | Not listed | Applied to or within 2 ft of window interior | Not listed | Unlock | 230-44O |
Central Commercial (C-1), Riverside Commercial (C-1R(A)), Riverside Transition (C-1R(B))
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (All Facades) | Not listed | Not greater than 2× length of wall in feet | Not listed | Not listed | One per tenant per street facade | Each facade fronting a street | Not listed | Unlock | 230-44P(4)(a)[1-3] |
| Freestanding Sign (>=25 ft setback) | Not listed | 40 sq ft per face | Not listed | Min. 25 ft from curbline | 1 | Where building set back ≥ 25 ft from curbline | Not listed | Unlock | 230-44P(4)(a)[4] |
| Freestanding Sign (15-25 ft setback) (Special Permit) | Not listed | Up to 40 sq ft per face or lesser as prescribed by ZBA | Not listed | Min. 15 ft and <25 ft from curbline/edge | 1 | Where building set back 15-25 ft from curb/edge | Not listed | Unlock | 230-44P(4)(a)[4] |
| Wall Sign (Service Stations) | Not listed | Not listed | Not listed | Not listed | One per wall per street + one freestanding | On each wall fronting a street | Not listed | Unlock | 230-44P(4)(b)[1] |
| Freestanding Sign (Service Stations) | Not listed | Not listed | Not listed | Not listed | 1 | On service station property | Not listed | Unlock | 230-44P(4)(b)[1] |
| Vehicle Window Sign (Interior) | Not listed | 180 sq in (12 in x 15 in) per sign | Not listed | Not listed | 1 per vehicle | Interior of vehicle | Not listed | Unlock | 230-44P(4)(b)[2] |
General Commercial (C-2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (All Facades) | Not listed | Not greater than 2× length of wall in feet | Not listed | Not listed | One per tenant per street facade | Each facade fronting a street | Not listed | Unlock | 230-44P(5)(a) via P(4) |
| Freestanding Sign (>=25 ft setback) | Not listed | 40 sq ft per face | Not listed | Min. 25 ft from curbline | 1 | Where building set back ≥ 25 ft from curbline | Not listed | Unlock | 230-44P(5)(a) via P(4) |
| Freestanding Sign (15-25 ft setback) (Special Permit) | Not listed | Up to 40 sq ft per face or lesser as prescribed by ZBA | Not listed | Min. 15 ft and <25 ft from curbline/edge | 1 | Where building set back 15-25 ft from curb/edge | Not listed | Unlock | 230-44P(5)(a) via P(4) |
| Wall Sign (Service Stations & Auto Sales) | Not listed | Not listed | Not listed | Not listed | One per wall per street + one freestanding | On each wall fronting a street | Not listed | Unlock | 230-44P(5)(c)[1] |
| Freestanding Sign (Service Stations & Auto Sales) | Not listed | Not listed | Not listed | Not listed | 1 | On lot | Not listed | Unlock | 230-44P(5)(c)[1] |
| Vehicle Window Sign (Interior) | Not listed | 180 sq in (12 in x 15 in) per sign | Not listed | Not listed | 1 per vehicle | Interior of vehicle | Not listed | Unlock | 230-44P(5)(c)[2] |
| Drive-in Theater Signs - Theater Name | Not listed | Not listed | Not listed | Not listed | 1 | Affixed to reverse side of theater screen structure | Not listed | Unlock | 230-44P(5)(b)[1] |
| Drive-in Theater Signs - Supplementary | Not listed | Not listed | Not listed | Not listed | 1 per feature/announcement | On same face as theater name sign | Not listed | Unlock | 230-44P(5)(b)[2] |
PermitPal covers all 9 zoning districts in Croton-on-Hudson. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Croton-on-Hudson
- No sign shall be erected, replaced, moved or modified except in conformity with the provisions of this chapter.
- All signs, except for temporary signs and certain billboards, must pertain to a use conducted on the same property on which the sign is located.
- Sign illumination shall not be twinkling, flashing, intermittent (except for time/temperature signs), or of changing degrees of color or intensity.
- No sign shall contain or consist of Day-Glo-like material.
- No light source used for illuminating signage shall be a source of glare.
- No sign shall be located so as to obscure any signs displayed by a public authority.
- No sign shall be placed in such a way as to obstruct proper vehicular sight distance.
- No sign shall interfere with pedestrian or vehicular traffic flow.
- No sign shall interfere with any ventilation system, door, window, fire escape or other emergency exit.
- No sign or sign component shall be moving, animated, rotating or revolving.
- No sign shall contain removable letters, except for signs associated with educational, religious, or municipal institutions, gas stations, or movie theaters.
- Light strips and strings of lights shall not be used for advertising or attracting attention to a sign when they do not comprise the text of the sign.
- All signs must be kept in good repair and in safe, neat and clean condition.
- All signs and related illumination shall be of a professional quality (except as exempted).
- Marquee signs are permitted for theaters only.
- Projecting signs must not project vertically above the roofline or parapet, or extend horizontally beyond the limits of the building.
- Billboards are prohibited except for those existing on the effective date associated with a site on the National Register of Historic Places.
- Signs that compete for attention with or may be mistaken for a traffic signal are prohibited.
- Searchlights, beacons, blimps, and permanent balloons are prohibited.
- Signs attached to or painted on trucks or other large vehicles, when obviously marked and parked to advertise or attract attention, are prohibited.
- Banners, flags, strings of balloons, flags or lights, or similar outdoor advertising are prohibited except on a temporary basis with respect to the opening, reopening, or remodeling of the business (maximum duration of 45 days).
Exempt Signs in Croton-on-Hudson
- Temporary signs do not require a signage permit (subject to restrictions and duration limits as set forth in Subsection K).
- Temporary signs must conform with all other provisions of the chapter except with respect to being of a professional quality (Subsection H).
- Residential yard signs (up to three, nonilluminated, each not exceeding six square feet and no higher than 42 inches above existing ground surface) do not require professional quality as required in Subsection H.
- Nonconforming billboards that existed on the effective date of these regulations are exempt if associated with a site on the National Register of Historic Places.
- Certain temporary signs (real estate, construction, election, garage/tag sales, civic/educational/religious events) are exempt from permit and/or standard limits, as detailed in Subsection K.
Sign Plan & Submission Notes for Croton-on-Hudson
- All signage applications (except temporary signs and certain residential yard signs) are reviewed by the Village Engineer, Visual Environment Board (VEB), and, as appropriate, the Planning Board.
- If signage is part of a site plan approval or a change of use approval, the Planning Board's decision on the site plan shall include its decision on the proposed signage.
- The Planning Board may require the submission of an illumination plan for illuminated signage.
- Where a building or site is permitted more than one sign by the provisions of this chapter, all new signs shall be consistent relative to one another in terms of size, shape, and location. Further, the Planning Board may require the submission of a master signage plan for the site which shows such consistency.
- The Planning Board may require a master signage plan as per Subsection N.
- For Waterfront Development districts, the Planning Board may require signage details as part of the site development plan review process.
- Modifications to sign requirements may be granted by the Planning Board, who may attach conditions to any such approval.