Sign Regulations in Hurley Town, New York
Hurley Town, New York has specific sign regulations covering 14 sign types across 6 zoning districts. Regulated sign types include Real Estate Sign, Wall Sign (Permitted Nonresidential Use), Freestanding Sign (Permitted Nonresidential Use). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Hurley Town, New York
Sample Sign Requirements in Hurley Town
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Wall Sign (Permitted Nonresidential Use) | Not listed | 32 square feet (aggregate total face area) | Not listed |
| Freestanding Sign (Permitted Nonresidential Use) | 5 feet | 15 square feet (total face area); if double-sided, 8 square feet per side (max two sides) | Minimum 10 feet to any property line or road (whichever is greater) |
| Wall Sign (Multi-Family Dwelling) | Not listed | 12 square feet (aggregate total face area) | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
14
- Real Estate Sign
- Wall Sign (Permitted Nonresidential Use)
- Freestanding Sign (Permitted Nonresidential Use)
- Wall Sign (Multi-Family Dwelling)
- +2 more types
Zoning Districts
6
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Hurley Town
Other Cities in New York
Frequently Asked Questions
In Hurley Town, the height limit for Freestanding Sign (Permitted Nonresidential Use) in the Residential District is 5 feet (Sec. 210-32A(1)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Hurley Town require a permit. We haven't published Hurley Town's application steps on this page yet. Run a code check for an exact address to see the permit requirements for that zone.
Hurley Town's sign code covers 14 sign types, including Real Estate Sign, Wall Sign (Permitted Nonresidential Use), Freestanding Sign (Permitted Nonresidential Use), and Wall Sign (Multi-Family Dwelling). Most commercial signs need a permit. The ordinance lists 5 exemptions. One of them: Traffic or other municipal signs, legal notices, and such temporary, emergency or nonadvertising signs as may be authorized by the Town. The full list is on this page.
This page doesn't list a single setback distance for signs in Hurley Town. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Rules in Hurley Town's sign ordinance that cover digital, changing, or flashing signs: Illumination of signs shall not be of intermittent or varying intensity or produce direct glare beyond the limits of the side property line. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Hurley Town Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Hurley Town, New York, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Hurley Town, New York Sign Rules at a Glance
Hurley Town, New York regulates 14 sign types across 6 zoning districts. Representational Signs are capped at 15 square feet (Sec. 210-32D). Most commercial signs in Hurley Town require a permit.
Detailed Sign Ordinance Requirements for Hurley Town, New York
Sign Rules by Zoning District in Hurley Town (6 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Residential District | 4 | 5 feet | 32 square feet (aggregate total face area) | Not listed |
| General Business District, Neighborhood Commercial District | 2 | Not more than 20 feet above ground level or above the highest part of the building, whichever is less | 50 square feet (aggregate maximum) | Not listed |
| Highway Business District, Light Industrial Office District | 1 | Not more than 20 feet above ground level or five feet above roof height at sign location, whichever is less | 100 square feet (aggregate per establishment) | Not listed |
| Business District | 1 | Not listed | 6 square feet (aggregate total face area) | Not listed |
| Light Industrial District | 1 | Not listed | 32 square feet (aggregate total face area) | Not listed |
| General Regulations For All Zones | 6 | Not listed | 50 square feet (aggregate total face area) | Not listed |
Zone-by-Zone Sign Requirements in Hurley Town(sample of 3 of 6 zones)
Residential District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign (Permitted Nonresidential Use) | Not listed | 32 square feet (aggregate total face area) | Not listed | Not listed | Not listed | Must be attached to principal building; shall not project more than 24 inches beyond the building | Not listed | Unlock | §210-32A(1) |
| Freestanding Sign (Permitted Nonresidential Use) | 5 feet | 15 square feet (total face area); if double-sided, 8 square feet per side (max two sides) | Not listed | Minimum 10 feet to any property line or road (whichever is greater) | 1 | On ground; for permitted nonresidential uses set back from property lines | Not listed | Unlock | §210-32A(1) |
| Wall Sign (Multi-Family Dwelling) | Not listed | 12 square feet (aggregate total face area) | Not listed | Not listed | Not listed | Attached to principal building; projecting not more than 24 inches from building | Not listed | Unlock | §210-32A(2) |
| Nameplate/Professional Sign (Residential Use) | Not listed | 4 square feet | Not listed | Not listed | 1 | Not listed | Not listed | Unlock | §210-32A(3) |
General Business District, Neighborhood Commercial District
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| General Business Sign | Not more than 20 feet above ground level or above the highest part of the building, whichever is less | 50 square feet (aggregate maximum) | Not listed | Not listed | 2 per business unit | Signs shall not project more than five feet beyond the principal building on lot | Not listed | Unlock | §210-32B |
| Projecting Sign | Not listed | Not listed | Not listed | Not listed | 1 per business unit | May project up to five feet beyond building | Not listed | Unlock | §210-32B, §210-32F |
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Representational Sign | Not listed | 15 square feet | Not listed | Not listed | 1 per establishment | Attached to principal structure; may project up to five feet beyond structure | Not listed | Unlock | §210-32D |
| Directional Sign (Off-Premises) | Not listed | 4 square feet per establishment | Not listed | Not listed | Not listed | Grouped on community poles | Not listed | Unlock | §210-32E |
| Projecting Sign (Public Right-of-Way) | Not listed | Not listed | Not listed | Not listed | Not listed | Projecting into public right-of-way | Not listed | Unlock | §210-32F |
| Subdivision Sign | Not listed | 50 square feet (aggregate total face area) | Not listed | Not listed | Not listed | Within subdivision or adjoining property in same ownership | Not listed | Unlock | §210-32G |
| Construction Site Sign | Not listed | 24 square feet | Not listed | Not listed | 1 per construction site | On-site under construction | Not listed | Unlock | §210-32H(3) |
| Memorial Sign / Building Tablet | Not listed | Not listed | Not listed | Not listed | Not listed | Cut into masonry surface or constructed of bronze, stainless steel or similar material | Not listed | Unlock | §210-32H(4) |
PermitPal covers all 6 zoning districts in Hurley Town. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Hurley Town
- No sign or other device for advertising purposes of any kind may be erected or established in the municipality except as provided by the ordinance.
- Advertising signs not pertaining to the use, sale, rent or lease of property on the same lot and signs not representing construction or subdivision activity are not permitted in any district, except as provided for directional signs approved by the Planning Board.
- No representational sign shall be permitted in any district, except as approved by the Planning Board.
- Signs projecting into any public right-of-way are prohibited without written approval from the Town Planning Board.
- Illumination of signs shall not be of intermittent or varying intensity or produce direct glare beyond the limits of the side property line.
- Red, green, and amber lights of such shape and hue that they may be confused with official traffic lights and signals are prohibited.
- All bare incandescent light sources and immediately adjacent reflecting surfaces shall be shielded from view.
- Banners and similar devices are prohibited, except nonpermanent ones displayed for special events (limited to three weeks).
- Any sign that no longer advertises a business or product available to the public on the premises must be removed within 10 days after written notification from the Zoning Enforcement Officer.
- Posters for events may only be displayed within four weeks prior to the event and must be removed within one week after the event.
- All temporary nonpermanent posters must include the identification of the person responsible for the poster.
Exempt Signs in Hurley Town
- Real estate signs advertising the sale, rental, or lease of the premises upon which said signs are located, not exceeding six square feet in residential and business districts, or 32 square feet in light industrial districts.
- One professional or business nameplate not exceeding one square foot in area for one professional or business establishment where such signs would not otherwise be a permitted use.
- One sign, not exceeding 24 square feet in area, denoting the architect, engineer and/or contractor when placed on a site under construction.
- Memorial signs or tablets, names of buildings, and dates of erection when cut into any masonry surface or constructed of bronze, stainless steel or similar material.
- Traffic or other municipal signs, legal notices, and such temporary, emergency or nonadvertising signs as may be authorized by the Town.
Sign Plan & Submission Notes for Hurley Town
- Representational signs require approval by the Planning Board.
- Directional signs not pertaining to the use, sale, rent or lease of property on the same lot require Planning Board approval.
- Signs projecting into a public right-of-way require written approval from the Town Planning Board.
Source: ecode360 municipal code