Sign Regulations in Murray, New York

Murray, New York has specific sign regulations covering 11 sign types across 6 zoning districts. Regulated sign types include Monument Sign, Wall Sign, Bracket Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 27, 2026

Sign Regulation Overview for Murray, New York

Sample Sign Requirements in Murray

Sign TypeMax HeightMax AreaSetback
Wall SignShall not extend above roof line, parapet wall, second story, or lower eave line of pitched roof15% of wall area
Monument Sign6 feetVaries by district: 36 square feet (RA, B), 15 square feet (RH, I)Minimum 5 feet from any property line (10 feet in Conservation Overlay District)
Bracket Sign5 feet (structure); 3 feet (sign area)10 square feet

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for MurrayFull Coverage

Sign Types Covered

11

  • Monument Sign
  • Wall Sign
  • Bracket Sign
  • Temporary Sign
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Murray

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

In Murray, wall signs can be up to Shall not extend above roof line, parapet wall, second story, or lower eave line of pitched roof and monument signs are limited to 6 feet. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Murray, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Murray, regulated sign types include Monument Sign, Wall Sign, Bracket Sign, Temporary Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Murray, monument signs typically require a Minimum 5 feet from any property line (10 feet in Conservation Overlay District) setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Murray are regulated with specific requirements for brightness, animation, and message duration. Murray has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Murray Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Murray, New York sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Murray, New York Sign Rules at a Glance

Murray, New York regulates 11 sign types across 6 zoning districts. Monument Signs in the Business District (B) zoning district are capped at 6 feet tall and 36 square feet, with a Minimum 5 feet from any property line setback (Sec. Sec. 501.S). Most commercial signs in Murray require a permit.

Detailed Sign Ordinance Requirements for Murray, New York

Sign Rules by Zoning District in Murray (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones46 feetVaries by district: 36 square feet (RA, B), 15 square feet (RH, I)
Residential-Agricultural District (RA)66 feet36 square feet
Business District (B)11Shall not exceed building height (20% above on 1-story); below 3rd story sills on 3+ stories36 square feet
Residential-Hamlet District (RH)11Shall not exceed building height (20% above on 1-story); below 3rd story sills on 3+ stories32 square feet
Industrial District (I)76 feet32 square feet
Conservation Overlay District (C)16 feetAs per underlying base district

Zone-by-Zone Sign Requirements in Murray(sample of 3 of 6 zones)

Business District (B)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignShall not extend above roof line, parapet wall, second story, or lower eave line of pitched roof15% of wall areaOne per establishment per building wall visible from public right-of-way (excludes awning and window signs)Attached to exterior front, rear, or side of building with display surface parallel to wallUnlockSec. 501.L
Awning Sign2 feet (text and graphics on valance)25% of awning area75% of awning width/depthOne per awning face per establishmentIntegrated on awning material over ground story doors or windowsUnlockSec. 501.M
Canopy Sign2 feet (text and graphics)25% of canopy area75% of canopy widthOne per canopy per establishmentOn canopy parallel to wall, over accessible building entranceUnlockSec. 501.N
Projecting Sign4 feet if mounted below 2nd floor; 8 feet if on 2nd or 3rd floor (average if across floors)10 square feetOne per establishment per building wall visible from public right-of-way; minimum 25 feet spacingAttached to building facade at 90-degree angle, extending more than 15 inches (2D or 3D)UnlockSec. 501.O
Monument Sign6 feet36 square feetMinimum 5 feet from any property lineOne per street frontage; one additional for 200+ feet frontage; minimum 150 feet spacingFreestanding, attached to ground along entire length to continuous pedestal (horizontal or square orientation)UnlockSec. 501.S
Iconic SignShall not exceed building height (20% above on 1-story); below 3rd story sills on 3+ stories36 square feetMinimum 18 inches from curb line (freestanding)One per establishmentBuilding-mounted or freestandingUnlockSec. 501.T
Bracket Sign5 feet (structure); 3 feet (sign area)10 square feet3 feetOne per building; minimum 25 feet from other bracket signsFreestanding, attached to ground by support structures, hanging from integral bracketUnlockSec. 501.U
Sidewalk Sign5 feet20 square feet4 feetMultiple permitted; minimum 25 feet spacingMoveable on sidewalk, not secured to groundUnlockSec. 501.V

Residential-Hamlet District (RH)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignShall not extend above roof line, parapet wall, second story, or lower eave line of pitched roof15% of wall areaOne per establishment per building wall visible from public right-of-way (excludes awning and window signs)Attached to exterior front, rear, or side of building with display surface parallel to wallUnlockSec. 501.L
Awning Sign2 feet (text and graphics on valance)20% of awning area75% of awning width/depthOne per awning face per establishmentIntegrated on awning material over ground story doors or windowsUnlockSec. 501.M
Canopy Sign2 feet (text and graphics)20% of canopy area75% of canopy widthOne per canopy per establishmentOn canopy parallel to wall, over accessible building entranceUnlockSec. 501.N
Projecting Sign4 feet if mounted below 2nd floor; 8 feet if on 2nd or 3rd floor (average if across floors)10 square feetOne per establishment per building wall visible from public right-of-way; minimum 25 feet spacingAttached to building facade at 90-degree angle, extending more than 15 inches (2D or 3D)UnlockSec. 501.O
Monument Sign6 feet15 square feetMinimum 5 feet from any property lineOne per street frontage; one additional for 200+ feet frontage; minimum 150 feet spacingFreestanding, attached to ground along entire length to continuous pedestal (horizontal or square orientation)UnlockSec. 501.S
Iconic SignShall not exceed building height (20% above on 1-story); below 3rd story sills on 3+ stories15 square feetMinimum 18 inches from curb line (freestanding)One per establishmentBuilding-mounted or freestandingUnlockSec. 501.T
Bracket Sign5 feet (structure); 3 feet (sign area)10 square feet3 feetOne per building; minimum 25 feet from other bracket signsFreestanding, attached to ground by support structures, hanging from integral bracketUnlockSec. 501.U
Sidewalk Sign5 feet20 square feet4 feetMultiple permitted; minimum 25 feet spacingMoveable on sidewalk, not secured to groundUnlockSec. 501.V

Industrial District (I)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignShall not extend above roof line, parapet wall, second story, or lower eave line of pitched roof15% of wall areaOne per establishment per building wall visible from public right-of-way (excludes awning and window signs)Attached to exterior front, rear, or side of building with display surface parallel to wallUnlockSec. 501.L
Awning Sign2 feet (text and graphics on valance)20% of awning area75% of awning width/depthOne per awning face per establishmentIntegrated on awning material over ground story doors or windowsUnlockSec. 501.M
Canopy Sign2 feet (text and graphics)20% of canopy area75% of canopy widthOne per canopy per establishmentOn canopy parallel to wall, over accessible building entranceUnlockSec. 501.N
Window Sign25% of window spaceMultiple permitted, subject to total area limit per floor/sidePainted or affixed on ground or second story windows/doors, or inside within 4 feet of window (excludes product display graphics)UnlockSec. 501.Q
Monument Sign6 feet15 square feetMinimum 5 feet from any property lineOne per street frontage; one additional for 200+ feet frontage; minimum 150 feet spacingFreestanding, attached to ground along entire length to continuous pedestal (horizontal or square orientation)UnlockSec. 501.S
Bracket Sign5 feet (structure); 3 feet (sign area)10 square feet3 feetOne per building; minimum 25 feet from other bracket signsFreestanding, attached to ground by support structures, hanging from integral bracketUnlockSec. 501.U
Temporary SignBottom no higher than 5 feet above grade32 square feetOn the same lot as the permitted useUnlockSec. 501.I

PermitPal covers all 6 zoning districts in Murray — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 6 zones for Murray — start free

Prohibited Signs in Murray

  • No off-premises signs shall be allowed unless approved by the Planning Board prior to placement.
  • No sign shall include lights which flash, move, or appear to move.
  • No sign shall impair or cause confusion of vehicular or pedestrian traffic, in its design, color or placement.
  • No sign shall be posted on a public utility pole or traffic control pole or structure.
  • Pole signs are not permitted.
  • Blinking, flashing and chasing light sources are not allowed.
  • Bare bulb illumination is not allowed.
  • Visible transformers are not allowed.

Exempt Signs in Murray

  • A sign permit is not required for any signs.
  • Existing nonconforming signs that are legal at the time of enactment may remain as long as they are properly maintained and their use remains current.
  • The owner of any allowed sign may substitute noncommercial copy in lieu of commercial or other non-commercial copy.

Sign Plan & Submission Notes for Murray

  • The size, type and location of all signage must be included in any application for site plan review; the Planning Board will review the proposed signage as part of site plan review.
  • Off-premises signs require approval by the Planning Board prior to placement.
  • Any person aggrieved by a decision of the Code Enforcement Officer relative to dimensional provisions may appeal by applying for an area variance to the Zoning Board of Appeals.
  • The Code Enforcement Officer may require review by the Town Engineer for sign construction; if questionable, a professional review by a New York State registered engineer is required.

Source: other municipal code