Springville, New York has specific sign regulations covering 32 sign types across 5 zoning districts. Regulated sign types include Wall Sign, Freestanding Sign (Detached or Ground Identification), Directional Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 28, 2025

Sign Regulation Overview for Springville, New York

Sample Sign Requirements in Springville

Sign TypeMax HeightMax AreaSetback
Freestanding Sign (Detached or Ground Identification)B-1 or VI: 18 ft; CIP: 25 ftB-1 or VI: 40 sq ft; CIP: 65 sq ftMinimum 20 ft from property line, unless average setback (if less than 10 ft) applies.
Directional Sign4 sq ft
Permanent Variable Copy Digital SignPer freestanding sign height: CIP up to 25 ft; B-1/VI up to 18 ft32 sq ft maxMeets same setback/location as freestanding sign (§200-31, §200-32)

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for SpringvilleFull Coverage

Sign Types Covered

32

  • Wall Sign
  • Freestanding Sign (Detached or Ground Identification)
  • Directional Sign
  • Permanent Variable Copy Digital Sign
  • +2 more types

Zoning Districts

5

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Springville

Frequently Asked Questions

In Springville, monument signs are limited to B-1 or VI: 18 ft; CIP: 25 ft. Height limits vary by zoning district and sign type. Use PermitPal to get exact requirements for your specific location.

To get a sign permit in Springville, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Springville, regulated sign types include Wall Sign, Freestanding Sign (Detached or Ground Identification), Directional Sign, Permanent Variable Copy Digital Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Springville, monument signs typically require a Minimum 20 ft from property line, unless average setback (if less than 10 ft) applies. setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Springville are regulated with specific requirements for brightness, animation, and message duration. Springville has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Springville Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Springville, New York sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Springville, New York Sign Rules at a Glance

Springville, New York regulates 32 sign types across 5 zoning districts. Sandwich Board Sign (Type H, Two-sided Sidewalk Sign)s in the Nonresidential Districts zoning district are capped at 4 ft tall, 2 ft width x 4 ft height (8 sq ft per side), and 2 ft wide, with a No closer than 1 ft to street edge setback (Sec. §200-35D(8)). Most commercial signs in Springville require a permit.

Detailed Sign Ordinance Requirements for Springville, New York

Sign Rules by Zoning District in Springville (5 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Business District (B-1), Village Industrial District (VI), Commercial and Industrial Park District (CIP), Business and Industrial Districts7Per freestanding sign height: CIP up to 25 ft; B-1/VI up to 18 ftCIP: 65 sq ft; B-1/VI: 40 sq ft
Nonresidential Districts612 ft32 sq ft
Residence District116 ft40 sq ft
R-8.5, R-616 sq ft (R-8.5 and R-6); 9 sq ft per §200-35D(9)
General Regulations For All Zones74 ft32 sq ft

Zone-by-Zone Sign Requirements in Springville(sample of 3 of 5 zones)

Nonresidential Districts

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Sandwich Board Sign (Type H, Two-sided Sidewalk Sign)4 ft2 ft width x 4 ft height (8 sq ft per side)2 ftNo closer than 1 ft to street edgeOne per business entityNo closer than 1 ft to the street edge; must not obstruct pedestrian trafficUnlock§200-35D(8)
Feather and Flag-type Sign (Type N)12 ftFlag area: max 8 ft tall x 2.5 ft wide; total max height 12 ft2.5 ftOne per businessOutside right-of-way on property of business; in B-1 may be between curb and sidewalk; must not interfere with pedestrian/vehicular traffic.Unlock§200-35D(14)
Business Special Event Sign (Type C, Business Promotion)32 sq ftMin 6 ft from any lot lineMax two per eventOn lot where event takes place; not closer than 6 ft to any lot lineUnlock§200-35D(3)
Variable Copy Temporary Sign (Type D)32 sq ftMin 6 ft from any lot lineOne per businessNo closer than 6 ft to any lot lineUnlock§200-35D(4)
Charitable Event Sign (Type G)8 sq ft (32 sq ft if on property owned by sponsoring org)Min 6 ft from any lot lineOne per lotNo closer than 6 ft to any lot lineUnlock§200-35D(7)
Nonresidential Real Estate Sign (Type J)32 sq ftMin 8 ft from all property linesMax two per lotOn site available for sale/rent; not within 8 ft of any property line; may also be placed on buildingUnlock§200-33(L), §200-35D(10)

Residence District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Freestanding or Building-mounted Sign (Home Occupation)4 ft (freestanding)4 sq ftFreestanding: min 15 ft from all property linesOne per home occupationOn premises; if freestanding, min 15 ft from any property lineUnlock§200-33(A)
Freestanding or Building-mounted Sign (Home Professional Office)4 ft (freestanding)8 sq ftFreestanding: min 15 ft from all property linesOne per home professional officeOn premises; if freestanding, min 15 ft from any property lineUnlock§200-33(A)
Building-Mounted Sign (Other Lawful Business)12 sq ftOne per lawful businessOn buildingUnlock§200-33(B)
Identification Sign (Institutional/Community Use)12 sq ftOne per useFreestanding or building-mountedUnlock§200-33(C)
Subdivision Identification Sign6 ft40 sq ftOne per subdivisionEntrance to subdivisionUnlock§200-33(D)
Subdivision Sale Sign32 sq ftOne per subdivision entranceEntrance to subdivisionUnlock§200-33(E)
Address Numbers2 sq ftBuilding-mountedUnlock§200-33(G)
Freestanding or Building-Mounted Name/Address Sign (Private Dwelling)4 ft (if freestanding)2 sq ftFreestanding: min 8 ft from all property linesOne per dwellingIf freestanding, min 8 ft from property line; otherwise on buildingUnlock§200-33(J)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Political Temporary Sign (Type A)16 sq ft per sign; max 24 sq ft per lotMin 6 ft from lot lineMax 4 per lotNo closer than 6 ft to any lot lineUnlock§200-35D(1)
Noncommercial Speech Temporary Sign (Type B)4 ft6 sq ftMin 15 ft from lot lineMax 2 per lotNo closer than 15 ft to lot lineUnlock§200-35D(2)
Garage/Yard Sale Sign (Type E)6 sq ft eachMin 6 ft from lot lineMax 2 per lotOnly on residential lots, only on lot where sale takes place, not closer than 6 ft to lot lineUnlock§200-35D(5)
Auction Sign (Type F)16 sq ft eachMin 6 ft from lot lineMax 2 per lotOn site of auction, at least 6 ft from lot lineUnlock§200-35D(6)
Event Location Sign (Type K)6 sq ft eachMin 1 ft from street edge1 per intersection, max 2 in villageNot closer than 1 ft to street edge, supported on its own (not attached to utility poles or other private/public structures)Unlock§200-35D(11)
Construction Sign (Type L)6 sq ftOne per lotMidway on lot where work is being performedUnlock§200-35D(12)
Subdivision Sale Sign (Type M)32 sq ftOne per entranceEntranceway to subdivision or as directed by Planning BoardUnlock§200-35D(13)

PermitPal covers all 5 zoning districts in Springville — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 5 zones for Springville — start free

Prohibited Signs in Springville

  • No sign shall be erected in the Village without a permit issued by the Code Enforcement Officer, except for exempted signs in § 200-35.
  • All signs must be securely attached to a building or structurally sound support and maintained in good repair.
  • No sign, its lighting, or design shall create a traffic hazard or nuisance or be unreasonably detrimental to adjoining or neighboring properties.
  • No surface-mounted sign overhanging a public right-of-way or sidewalk shall extend more than 12 inches from the building face unless a written engineer’s statement certifies safety.
  • No sign shall contain banners, posters, pennants, ribbons, streamers or similar fluttering devices that interfere with public safety or create a public nuisance.
  • No portable/movable signs are allowed unless specifically approved under § 200-35.
  • No sign shall be attached to fences, utility poles, or trees on public property without written permission of the Village Board of Trustees.
  • No sign shall advertise business uses or services other than those which exist on the premises.
  • No sign shall be erected in such a manner as to confuse or obstruct the view of any traffic sign, signal, or device.
  • No sound amplifiers, public address systems or sound devices shall be used as a means of advertising or to attract attention to a sign.
  • No portable, movable or temporary sign shall be within any public right-of-way, except for specified types as per § 200-35.
  • No portable, movable or temporary sign shall unreasonably obstruct or interfere with pedestrian or vehicular traffic and its sight lines.
  • No portable, movable or temporary sign shall be internally or externally illuminated.
  • No person, corporation, or association shall post any handbill, notice or placard on any post, utility pole, tree, fence, building, or other object, or deposit the same in any vehicle or public place.
  • No sign or banner may be erected or suspended over a public street without the consent of the Board of Trustees, and any such sign attached to a building adjoining a public street shall be not less than 10 feet from the sidewalk.
  • No sign may project over any public street or sidewalk without a written permit approved by the Board of Trustees and required insurance or bond.
  • No sign shall be maintained over sidewalks unless all parts, including structures, are at least seven feet above the sidewalk.
  • No sign is allowed that advertises off-premises businesses, products, or uses.

Exempt Signs in Springville

  • The regulations do not apply to any sign or directional device erected by any governmental agency.
  • The regulations do not apply to nonadvertising signs identifying underground utility lines.
  • The regulations do not apply to posted or preserve signs erected pursuant to the Environmental Conservation Law of the State of New York.
  • A range of portable, movable and temporary signs (Types A through N) are allowed without a permit under § 200-35D when meeting size, location, and duration requirements.

Sign Plan & Submission Notes for Springville

  • An overall sign design plan for multiple-commercial use facilities or industrial parks is required and must be submitted with the application for the site development permit; the plan must show reasonable uniformity of design, lettering, lighting, and material (see § 200-32E).
  • The Architectural Review Board is appointed to review and recommend the design, construction, and aesthetics of any proposed sign that requires a permit (see § 200-30M and § 200-37B).
  • If a project subject to zoning review is proposed for a property with a nonconforming sign, the reviewing agency shall require the nonconforming sign to be brought into compliance as a condition of approval (see § 200-36B).
  • Sign plan related provisions may be enforced through the Planning Board as part of the site plan review process for certain sign types (see § 200-35D(13)(f)).

Source: ecode360 municipal code