Yonkers, New York has specific sign regulations covering 17 sign types across 7 zoning districts. Regulated sign types include Ground Sign (Freestanding), Pole Sign, Wall Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 4, 2026

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Yonkers, New York

Sample Sign Requirements in Yonkers

Sign TypeMax HeightMax AreaSetback
Ground Sign (Freestanding)16 ft if combustible; 35 ft if noncombustibleNot listed≥10 ft from any other ground or pole sign; ≥15 ft from corner point at street intersections; may not extend beyond property line
Pole Sign25 ft75 sq ft per faceProjection over property line ≤12 in (with 10 ft clearance above grade)
Wall SignVertical dimension (height) ≤4 ftWidth limited to ≤70% of the building wall length where placedMay not extend over public right-of-way beyond 12 in

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for YonkersFull Coverage

Sign Types Covered

17

  • Ground Sign (Freestanding)
  • Pole Sign
  • Wall Sign
  • Roof Sign (Existing Only; New Prohibited)
  • +2 more types

Zoning Districts

7

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Yonkers

City WebsiteMunicipal Code1 permit application link available

Yonkers, New York Sign Rules at a Glance

Yonkers, New York regulates 17 sign types across 7 zoning districts. Pole Signs are capped at 25 ft tall and 75 sq ft per face. Most commercial signs in Yonkers require a permit.

Detailed Sign Ordinance Requirements for Yonkers, New York

Sign Rules by Zoning District in Yonkers (7 zones)

Zoning DistrictSign Types RegulatedMax HeightMax Area
General Regulations For All Zones1125 ft75 sq ft per face
BR District (Restricted Business)1125 ft75 sq ft per face
Downtown Districts4≤25 ft≤75 sq ft per face
Artisans & Industry Special District (A & I)2No higher than immediately above the ground-floor windows≤9 sq ft (3 ft by 3 ft)
Ludlow Mixed-Use District (L-MX)9As per Chapter 47≤75 sq ft per face
Casino Special District2Not listedSize determined by Planning Board during site plan review
Mixed-Use District (D-MX); Downtown Industrial Research and Technology District (D-IRT); South Broadway District (SB)1Not listed≤8 sq ft

Zone-by-Zone Sign Requirements in Yonkers(sample of 3 of 7 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground Sign (Freestanding)16 ft if combustible; 35 ft if noncombustibleNot listed20 ft maximum horizontal width≥10 ft from any other ground or pole sign; ≥15 ft from corner point at street intersections; may not extend beyond property line1 for first 10,000 sq ft + 1 per additional 5,000 sq ft; max 3 per locationSupported by 2 or more uprights on the ground (not attached to a building); must be ≥10 ft from any other ground or pole sign; on corner lots must be set back ≥15 ft from the corner point (intersection of property lines)UnlockCh. 47 §47-3(B); §47-5(A)(1); §47-7(A)(1)-(9); §47-8; §47-10(C)
Pole Sign25 ft75 sq ft per faceNot listedProjection over property line ≤12 in (with 10 ft clearance above grade)1 for first 10,000 sq ft + 1 per additional 5,000 sq ft; max 3 per locationAffixed to a single upright pole without guys/braces; may not project over a property line by more than 12 in, and lower edge must be ≥10 ft above grade if projecting over property lineUnlockCh. 47 §47-3(B); §47-5(A)(1); §47-7(B)(1)-(5); §47-8
Wall SignVertical dimension (height) ≤4 ftWidth limited to ≤70% of the building wall length where placedNot listedMay not extend over public right-of-way beyond 12 inNot listedAffixed to a building wall (including parapet walls); must not interfere with Fire Department operationsUnlockCh. 47 §47-3(B); §47-5(A)(3); §47-7(C)(1)-(6); §47-8
Roof Sign (Existing Only; New Prohibited)Up to 20 ft above roof on non-fire-resistive buildings; up to 25 ft above roof on fire-resistive buildingsNot listedMax length 25 ft≥5 ft from building walls; clearances as aboveNot listedOn/over roof with principal supports on roofUnlockCh. 47 §47-7(D)(1)-(8); §47-13(B)(2)
Projecting Sign (Permitted only in D-MX, D-IRT, SB)Not listed8 sq ft maximum areaNot listedMust comply with projection limits over sidewalk; general prohibition against projecting over streets except as permitted1 per ground-floor use (1 per street frontage on a corner lot)Mounted on or immediately above facade/storefront of the ground-floor use; not mounted higher than the ground-floor use it servesUnlockCh. 47 §47-7(F)(1)-(5)
Vertical Sign≤15 ftNot listed≤2.5 ftProjection ≤12 in over public wayNot listedAffixed to front, side, or rear of a structureUnlockCh. 47 §47-7(H)(1)-(6); §47-5(A)(3); §47-8
Angle Sign≤10 ft vertical dimensionNot listed≤1.5 ft per faceProjection ≤12 in over public wayNot listedAffixed to front, side, or rear wallUnlockCh. 47 §47-7(I)(1)-(6); §47-5(A)(3); §47-8
Billboard (Off-Site Advertising) (Existing Only; New Prohibited)Ground-mounted: ≤16 ft if combustible; ≤25 ft if noncombustible. Roof-mounted: ≤20 ft above roof (non-fire-resistive); ≤25 ft above roof (fire-resistive)Not listedUnit width ≤25 ft (per sign unit)As specified for ground and roof installationsNot listedOff-site advertising sign on ground, wall, or roofUnlockCh. 47 §47-7(J)(1)-(5); §47-13(B)(1), (C)-(G); §47-5(A)(2)

BR District (Restricted Business)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Ground Sign (Freestanding)16 ft if combustible; 35 ft if noncombustibleNot listed20 ft maximum horizontal width≥10 ft from any other ground or pole sign; ≥15 ft from corner point at street intersections; may not extend beyond property line1 for first 10,000 sq ft + 1 per additional 5,000 sq ft; max 3 per locationSupported by 2 or more uprights on the ground (not attached to a building); must be ≥10 ft from any other ground or pole sign; on corner lots must be set back ≥15 ft from the corner point (intersection of property lines)UnlockCh. 47 §47-3(B); §47-5(A)(1); §47-7(A)(1)-(9); §47-8; §47-10(C)
Pole Sign25 ft75 sq ft per faceNot listedProjection over property line ≤12 in (with 10 ft clearance above grade)1 for first 10,000 sq ft + 1 per additional 5,000 sq ft; max 3 per locationAffixed to a single upright pole without guys/braces; may not project over a property line by more than 12 in, and lower edge must be ≥10 ft above grade if projecting over property lineUnlockCh. 47 §47-3(B); §47-5(A)(1); §47-7(B)(1)-(5); §47-8
Wall SignVertical dimension (height) ≤4 ftWidth limited to ≤70% of the building wall length where placedNot listedMay not extend over public right-of-way beyond 12 inNot listedAffixed to a building wall (including parapet walls); must not interfere with Fire Department operationsUnlockCh. 47 §47-3(B); §47-5(A)(3); §47-7(C)(1)-(6); §47-8
Roof Sign (Existing Only; New Prohibited)Up to 20 ft above roof on non-fire-resistive buildings; up to 25 ft above roof on fire-resistive buildingsNot listedMax length 25 ft≥5 ft from building walls; clearances as aboveNot listedOn/over roof with principal supports on roofUnlockCh. 47 §47-7(D)(1)-(8); §47-13(B)(2)
Vertical Sign≤15 ftNot listed≤2.5 ftProjection ≤12 in over public wayNot listedAffixed to front, side, or rear of a structureUnlockCh. 47 §47-7(H)(1)-(6); §47-5(A)(3); §47-8
Angle Sign≤10 ft vertical dimensionNot listed≤1.5 ft per faceProjection ≤12 in over public wayNot listedAffixed to front, side, or rear wallUnlockCh. 47 §47-7(I)(1)-(6); §47-5(A)(3); §47-8
Billboard (Off-Site Advertising) (Existing Only; New Prohibited)Ground-mounted: ≤16 ft if combustible; ≤25 ft if noncombustible. Roof-mounted: ≤20 ft above roof (non-fire-resistive); ≤25 ft above roof (fire-resistive)Not listedUnit width ≤25 ft (per sign unit)As specified for ground and roof installationsNot listedOff-site advertising sign on ground, wall, or roofUnlockCh. 47 §47-7(J)(1)-(5); §47-13(B)(1), (C)-(G); §47-5(A)(2)
Time and Temperature SignNot listed≤15 sq ftNot listedNot listedMax 1 per tractOn site; counts towards maximum permitted signs at the siteUnlockCh. 47 §47-7(K)(1)-(7)

Ludlow Mixed-Use District (L-MX)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignVertical dimension ≤4 ftWidth ≤70% of wall lengthNot listedProjection over public way ≤12 inNot listedAffixed to building wall/parapetUnlockCh. 43 §43-243; Ch. 47 §47-7(C); §47-3(B); §47-5
Ground Sign (Freestanding)16 ft combustible; 35 ft noncombustibleNot listedMax horizontal width 20 ft≥10 ft from other ground/pole signs; ≥15 ft from corner point1 for first 10,000 sq ft + 1 per +5,000 sq ft; max 3On ground; ≥10 ft from other ground/pole signs; corner setback ≥15 ftUnlockCh. 43 §43-243; Ch. 47 §47-7(A)
Pole Sign≤25 ft≤75 sq ft per faceNot listedProjection over property line ≤12 in (with ≥10 ft clearance)1 for first 10,000 sq ft + 1 per +5,000 sq ft; max 3Single upright pole; projection over property line ≤12 in with ≥10 ft clearanceUnlockCh. 43 §43-243; Ch. 47 §47-7(B)
Vertical Sign≤15 ftNot listed≤2.5 ftProjection over public way ≤12 inNot listedAffixed to front/side/rear of structureUnlockCh. 43 §43-243; Ch. 47 §47-7(H)
Angle Sign≤10 ft vertical dimensionNot listed≤1.5 ft per faceProjection over public way ≤12 inNot listedAffixed to front/side/rear wallUnlockCh. 43 §43-243; Ch. 47 §47-7(I)
Roof Sign (Existing Only; New Prohibited)See general limits (20 ft/25 ft above roof per construction type)Not listedMax length 25 ftAs per Chapter 47Not listedOn/over roofUnlockCh. 43 §43-243; Ch. 47 §47-7(D); §47-13(B)(2)
Billboard (Off-Site Advertising) (Existing Only; New Prohibited)As per Chapter 47Not listedUnit width ≤25 ftAs per Chapter 47Not listedGround/wall/roof as definedUnlockCh. 43 §43-243; Ch. 47 §47-7(J); §47-13(B)(1)
Time and Temperature SignNot listed≤15 sq ftNot listedNot listed1 per tractOn-site; counts towards max signsUnlockCh. 43 §43-243; Ch. 47 §47-7(K)

PermitPal covers all 7 zoning districts in Yonkers. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Yonkers

  • No sign may be erected, altered, relocated, removed, painted, repaired, or maintained except in conformity with Chapter 47 and only by a licensed sign erector with a valid sign permit (Yonkers Code §47-3(A), §47-3(B), §47-5(A)).
  • It is unlawful to tack, place, post, paint, print, or nail any sign/handbill/advertisement on public property or in public places (e.g., curbs, sidewalks, streets/highways, hydrants, lampposts, trees, utility poles, fences, benches, traffic signal stanchions, public buildings, or any other item/structure in any street), unless authorized by the City (Code §47-10(A)).
  • Signs may not be installed, erected, constructed, or maintained so as to obstruct any fire escape, window, or door, and no sign may be attached to a fire escape (Code §47-10(C)).
  • New signs that flash, rotate, move, or change in color or form are prohibited (time-and-temperature signs excepted); existing such signs must be made non-flashing/non-moving (Code §47-13(A)).
  • New off-site (off-premises) signs are prohibited (Code §47-13(B)(1)).
  • New rooftop signs (on or over the roof or above roof/parapet level) are prohibited (Code §47-13(B)(2)).
  • Outdoor signs advertising tobacco or alcohol products are prohibited within 1,000 feet of any public or private school, public park, or place of worship (Code §47-13(B)(3)).
  • New marquee signs are prohibited; no future marquee installations are permitted (Code §47-7(E)(5)).
  • Projecting signs are generally prohibited citywide; they are permitted only in the D‑MX, D‑IRT, and South Broadway Special Districts and must meet specified requirements (Code §47-7(F)(1), §47-7(F)(5)).
  • No electrified sign may be erected without the proper underwriters' label; electrification must be performed by a City-licensed electrician after securing necessary permits; electrified signs must be nonflashing (Code §47-8(A)–(C)).
  • Illuminated signs may not use red or green lighting where, in the opinion of the Commissioner, it would obscure or detract from traffic control lights; color lighting shall avoid traffic red and green (Code §47-8(E)).
  • Signs located on City property may remain only until the expiration of any applicable lease or agreement; such agreements shall be terminated immediately if authorized by their terms (Code §47-10(D)).

Exempt Signs in Yonkers

  • Temporary signs that are not permanently attached to a building or other permanent structure and not permanently affixed to the ground, displayed for no more than 90 days, and not exceeding 16 square feet in area are exempt from most provisions of Chapter 47, provided they are properly secured and remain subject to §§47-1, 47-2, 47-8, 47-10, 47-12, 47-13, and 47-14 (Code §47-6(A)(1)).
  • Signs less than two square feet in area are exempt from most provisions of Chapter 47, provided they are properly secured and remain subject to §§47-1, 47-2, 47-8, 47-10, 47-12, 47-13, and 47-14 (Code §47-6(A)(2)).
  • Signs on the premises of entities exempt from federal taxation under 26 U.S.C. §501(c)(3) are exempt from sign fees but are otherwise fully subject to all requirements of Chapter 47 (Code §47-6(B)).

Sign Permit Fees & Timelines in Yonkers

ItemDetailsCitation
Installation permit: Ground, roof, pole, or vertical signs (non-billboard), nonilluminated$1 per square foot§ 47-5(A)(1)(a)[1]
Standard Reviewgranted or denied within 10 days of the filing of a complete application (starts when Filing of a complete sign permit or license application)§ 47-3(I)
Start free to see all Yonkers sign permit fees & timelines

Source: ecode360 municipal code

Frequently Asked Questions

In Yonkers, the height limit for Pole Sign is 25 ft. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Yonkers require a permit. Installation permit: Ground, roof, pole, or vertical signs (non-billboard), nonilluminated: $1 per square foot. Standard Review: granted or denied within 10 days of the filing of a complete application (starts when Filing of a complete sign permit or license application) (Sec. 47-3(I)). Run a code check for an exact address to see the permit requirements for that zone.

Yonkers's sign code covers 17 sign types, including Ground Sign (Freestanding), Pole Sign, Wall Sign, and Roof Sign (Existing Only; New Prohibited). Most commercial signs need a permit. The ordinance lists 3 exemptions. One of them: Signs on the premises of entities exempt from federal taxation under 26 U.S.C. §501(c)(3) are exempt from sign fees but are otherwise fully subject to all requirements of Chapter 47 (Code §47-6(B)). The full list is on this page.

In Yonkers, Ground Sign (Freestanding) must be set back at least 10 ft from any other ground or pole sign. The ordinance adds other placement rules for this sign type, listed in the table on this page. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Yonkers's sign ordinance that cover digital, changing, or flashing signs: New signs that flash, rotate, move, or change in color or form are prohibited (time-and-temperature signs excepted); existing such signs must be made non-flashing/non-moving (Code §47-13(A)). Run a code check for an exact address to see the full illumination rules for that zone.