Sign Regulations in Mentor, Ohio
Mentor, Ohio has specific sign regulations covering 16 sign types across 4 zoning districts. Regulated sign types include Wall Sign, Window and Door Sign, Banner. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: June 13, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Mentor, Ohio
Sample Sign Requirements in Mentor
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Wall Sign | 30 feet above grade | Not listed | Not listed |
| Window and Door Sign | Not listed | Max 25% of window/door area; cumulative max 40 square feet or 25% of building glass area, whichever is less | Not listed |
| Flag | Flagpole max 40 feet | Flag size depends on pole height: 20' pole = 4x6', 25' = 5x8', 40' = 6x10' | Flagpole at least length of pole or building setback from lot line |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
16
- Wall Sign
- Window and Door Sign
- Banner
- Building Marker
- +2 more types
Zoning Districts
4
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Mentor
Other Cities in Ohio
Frequently Asked Questions
In Mentor, the height limit for Ground Sign (Setback at least 400 ft) in certain zoning districts is 18 feet (Sec. 1171.18(d)(2)(F)(iv)). The height limit for Wall Sign is 30 feet above grade. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Mentor require a permit. From the submission notes on this page: Permit applications must include detailed plans, renderings, and samples for review in accordance with Section 1171.08. Run a code check for an exact address to see the permit requirements for that zone.
Mentor's sign code covers 16 sign types, including Wall Sign, Window and Door Sign, Banner, and Building Marker. Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Notices required to be posted by law or order of court. The full list is on this page.
In Mentor, Ground Sign (Standard Setback) in certain zoning districts must be set back 5 ft from right-of-way, 15 ft side yard (Sec. 1171.18(d)(1)-(2)). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.
Rules in Mentor's sign ordinance that cover digital, changing, or flashing signs: Animated signs are prohibited. No sign shall have any lights or illumination that flash, move, rotate, scintillate, blink, flicker, vary in intensity or color, or use intermittent electrical pulses. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Mentor Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Mentor, Ohio, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Mentor, Ohio Sign Rules at a Glance
Mentor, Ohio regulates 16 sign types across 4 zoning districts. Ground Signs (Standard Setback) in certain zoning districts are capped at 10 feet tall, 40 square feet, and 5 feet wide, set back 5 ft from right-of-way, 15 ft side yard (Sec. 1171.18(d)(1)-(2)). Most commercial signs in Mentor require a permit.
Detailed Sign Ordinance Requirements for Mentor, Ohio
Sign Rules by Zoning District in Mentor (4 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 5 | Flagpole max 40 feet | Max 25% of window/door area; cumulative max 40 square feet or 25% of building glass area, whichever is less | Not listed |
| Commercial and Industrial Districts (B-1, B-2, B-3, C-2, Applicable PUD Parcels, MIP, M-1, M-2, MRD) | 12 | 18 feet | 150 square feet (base maximum, plus up to 187.5 sq ft if setback ≥300 ft) | Not listed |
| Special Districts (OV District, Old Village Commercial Corridor Overlay) | 7 | 8 feet | 50 square feet | Not listed |
| Residential Districts (R-1, R-2, R-3, R-4, R-5, R-10, RVG, RMH, C-1, Applicable PUD Parcels) | 3 | 5 feet | 20 square feet | Not listed |
Zone-by-Zone Sign Requirements in Mentor(sample of 3 of 4 zones)
General Regulations For All Zones
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | 30 feet above grade | Not listed | Not listed | Not listed | Not listed | Parallel to the wall, within 18 inches of wall, not further than 12 inches from the top/side, not on rear wall (except where allowed by zone); painted wall signs or murals prohibited. | Not listed | Unlock | 1171.16(l), 1171.06, 1171.08 |
| Canopy Sign | Not listed | Not listed | Not listed | Not listed | One per entrance or canopy | On canopy over entrance/window/outdoor area | Not listed | Unlock | 1171.16(m) |
| Window and Door Sign | Not listed | Max 25% of window/door area; cumulative max 40 square feet or 25% of building glass area, whichever is less | Not listed | Not listed | Not listed | On or over window or door, or directly behind visible from exterior | Not listed | Unlock | 1171.16(n) |
| Flag | Flagpole max 40 feet | Flag size depends on pole height: 20' pole = 4x6', 25' = 5x8', 40' = 6x10' | Not listed | Flagpole at least length of pole or building setback from lot line | One flagpole per 150 ft frontage | On flagpole per frontage, not on roof | Not listed | Unlock | 1171.16(o) |
| Banner | Not listed | Not listed | Not listed | Not listed | Not listed | Not listed | Not listed | Unlock | 1171.16(p) |
Commercial and Industrial Districts (B-1, B-2, B-3, C-2, Applicable PUD Parcels, MIP, M-1, M-2, MRD)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Ground Sign (Standard Setback) | 10 feet | 40 square feet | 5 feet | 5 ft from right-of-way, 15 ft side yard | 1 per development unit, with exceptions for additional access drives and interior access (see additional ground sign types) | Close to principal access drive; within lot frontage | Not listed | Unlock | 1171.18(d)(1)-(2) |
| Ground Sign (Setback at least 100 ft) | 12 feet | 55 square feet | 6 feet | 20 ft side yard | See above | At least 100 ft from right-of-way line | Not listed | Unlock | 1171.18(d)(2)(F)(i) |
| Ground Sign (Setback at least 200 ft) | 14 feet | 70 square feet | 7 feet | 25 ft side yard | Not listed | At least 200 ft from right-of-way line | Not listed | Unlock | 1171.18(d)(2)(F)(ii) |
| Ground Sign (Setback at least 300 ft) | 16 feet | 85 square feet | 8 feet | 30 ft side yard | Not listed | At least 300 ft from right-of-way line | Not listed | Unlock | 1171.18(d)(2)(F)(iii) |
| Ground Sign (Setback at least 400 ft) | 18 feet | 100 square feet | 9 feet | 35 ft side yard | Not listed | At least 400 ft from right-of-way line | Not listed | Unlock | 1171.18(d)(2)(F)(iv) |
| Ground Sign - Additional Access Drive | 10 feet | 40 square feet | 5 feet | 5 ft from R/W, 15 ft side yard; for larger setbacks/ground signs see above | One additional per qualifying drive | Additional access drive or interior access; must be adjacent to said drive. | Not listed | Unlock | 1171.18(d)(3)(A)-(B) |
| Temporary Ground Sign (Exempt - Option) | 5 feet | 15 square feet | 4 feet | Not listed | Not listed | Not listed | Not listed | Unlock | 1171.18(d)(4)(A) |
| Building Marker | Not listed | 4 square feet | Not listed | Not listed | One per building | Ground floor, adjacent to principal entrance | Not listed | Unlock | 1171.18(c) |
Special Districts (OV District, Old Village Commercial Corridor Overlay)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Ground Sign | 8 feet | 32 square feet | 4 feet | 5 feet from right-of-way; 15 feet from side lot line. | One per development unit | On property, per frontage, 5 ft from R/W, 15 ft side yard | Not listed | Unlock | 1171.19(e) |
| Wall Sign | Not listed | 50 square feet | Not listed | Not listed | Not listed | On front wall of the building unit, or divided between front and side wall, or (where permitted) canopy/marquee. Uniform height and at sign band, if present. | Not listed | Unlock | 1171.19(f) |
| Projecting Sign | Single story: 5 ft; Two-story: 10 ft | Single story: 17.5 sq ft; Two-story: 30 sq ft | 3.5 ft from wall face | Not listed | One per building unit | Perpendicular to wall, one per building unit, not within 20 feet of another projecting sign. | Not listed | Unlock | 1171.19(g) |
| Building Marker | Not listed | 4 square feet | Not listed | Not listed | One per building | Ground floor, adjacent to principal entrance | Not listed | Unlock | 1171.19(d) |
| Window and Door Sign | Not listed | 25% of area of window/door, cumulative not exceeding 40 sq ft or 25% total glass area (whichever is less) | Not listed | Not listed | Not listed | On/in window or door visible from exterior | Not listed | Unlock | 1171.16(n), 1171.19(b)(1)(D) |
| Banner | Not listed | Not listed | Not listed | Not listed | Not listed | Secured to withstand environmental loads. Must comply with sign location type/their size, as substitute. | Not listed | Unlock | 1171.18(f), 1171.19(b)(3) |
| Canopy Sign / Marquee Sign (Special Approval) | Not listed | Same as permitted wall sign area; taken from wall sign area allocation | Not listed | Not listed | Not listed | On canopy or marquee | Not listed | Unlock | 1171.19(b)(2) |
PermitPal covers all 4 zoning districts in Mentor. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Mentor
- No signs are permitted unless expressly allowed by the provisions of this chapter.
- Signs shall not be placed on any utility poles or utility equipment (unless pertaining to its use or operation and required to be placed there by the utility), hydrants, rocks/boulders, trees or other vegetation.
- No sign shall have more than two faces, which must be parallel to one another and within twenty-four (24) inches, unless a specific provision of this chapter requires a lesser dimension.
- Off-premise signs are prohibited.
- Signs which are abandoned or which are accessory to an abandoned use of property are prohibited.
- No sign shall be erected, relocated or maintained so as to prevent free ingress or egress, or block any light or ventilation openings. No sign shall be located or attached so as to obstruct emergency facilities or equipment.
- No sign shall be erected within the area of any sight triangle unless it is no greater than three (3) feet in height and does not otherwise obstruct free and clear vision within the sight triangle.
- No sign shall interfere, or otherwise cause visual conflict, in whole or in part, with any authorized traffic control sign, signal or device by virtue of the placement, color, or illumination of the sign.
- No sign shall be designed in such a manner that it is substantially similar in appearance to any authorized traffic control sign, signal or device that has the potential to cause confusion for motorists or pedestrians.
- No sign shall display any obscene matter, as defined by Section 533.01(f) of the Codified Ordinances.
- No sign shall depict or describe any specified sexual activities or specified anatomical areas, as defined by Section 1127.01 of this Code.
- Animated signs are prohibited.
- No sign shall have visible moving, revolving or rotating parts or visible mechanical movement of any kind.
- No sign shall emit any fire, smoke, steam, odor, or sound.
- No sign shall have any lights or illumination that flash, move, rotate, scintillate, blink, flicker, vary in intensity or color, or use intermittent electrical pulses.
- No sign shall be illuminated so as to cause objectionable brightness or glare into or onto any adjacent property or any right-of-way.
- Use of search lights, floodlights, and other such manner of directed light into the atmosphere is prohibited.
- Inflatable signs, inclusive of balloons used as signs, are prohibited.
- Wall signs painted directly upon any wall are prohibited. Mural and pictorial images are included in this prohibition.
- Pennants, spinners, streamers and such other similar manner of displays are prohibited.
- Bench signs are prohibited.
- Vehicles, trailers, and all such other mobile and semi-mobile equipment are not permitted to be used as either temporary or permanent signs either by virtue of having copy or signage placed on them or by virtue of their use, in context, as signs in their own right. (except for vehicles in transit or temporarily present for a transient purpose)
- Roof signs are prohibited.
- Signs are limited to two-dimensional graphic displays. The use of statuary, equipment, products, or any other such like displays is prohibited (except as permitted in certain sections).
- Signs projected upon any surface by means of light or shadow are prohibited.
- No person may erect or place any sign within a public right-of-way or upon City property, inclusive of City and other public easements, nor may any signs project over any of these areas.
- Signs erected in violation of this chapter are declared a nuisance and a trespass upon public lands and may be seized as contraband and removed immediately.
Exempt Signs in Mentor
- Signs which are not visible to a person of ordinary eyesight from or beyond any public right-of-way and any property line of the lot (or development unit, as applicable) upon which the sign is located.
- A traffic control sign, signal or device erected by a governmental entity, inclusive of such private property where compliance with the Manual on Uniform Traffic Control Devices is required.
- Public facilities signs erected by governmental entities, but subject to area, dimensional, and other applicable regulations of this chapter.
- Notices required to be posted by law or order of court.
- Signs otherwise exempt from municipal regulation pursuant to state or federal law.
- Signs held by or affixed in any manner to a person and not set on or affixed to the ground and/or any structure thereon either in whole or in part.
- Any street numbers required by and erected in conformity with Chapter 1347 of the Codified Ordinances provided that the numbers shall be no greater than twelve (12) inches in height.
Sign Plan & Submission Notes for Mentor
- For ground signs erected at significant front setbacks (commercial/industrial), the limitations imposed by Sections 1171.16(r)(5) and 1171.16(x) may be waived, provided that the proposed sign shall have first been reviewed and approved as an element of a site develop plan (or as amendment, as applicable). Review includes review of the proposed sign structure and/or related structure(s) for consistency with the City's Design Guidelines. Review shall be limited to the proposed sign's location as an element of good and orderly site planning and as an architectural element of the site but shall not consider sign content.
- Certain sign types (such as canopy, marquee, projecting) may be permitted only as part of an architectural feature approved for construction by the Planning Commission in accord with the City's Design Guidelines.
- Permit applications must include detailed plans, renderings, and samples for review in accordance with Section 1171.08.
- If an application for a permit is part of a development or redevelopment proposal made pursuant to Chapter 1133 of the Zoning Code, then the permit issued shall be a temporary permit only pending final City approval of the development or redevelopment proposal. Full approval may require modifications to erected signs to meet conditions of approval.
- A variance or appeal may be sought if a proposed sign does not conform to code provisions, requiring consideration by the Board of Building and Zoning Appeals.
Source: amlegal municipal code