Questions? Call us at (262) 218-2915

Sign Regulations in Bethlehem, Pennsylvania

Bethlehem, Pennsylvania has specific sign regulations covering 36 sign types across 13 zoning districts. Regulated sign types include Wall/Projecting Sign (Business Use), Sandwich Board/Sidewalk Sign, Wall Sign (Principal Non-Residential Use). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: July 9, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Bethlehem, Pennsylvania

Sample Sign Requirements in Bethlehem

Sign TypeMax HeightMax AreaSetback
Wall Sign (Principal Non-Residential Use)25 ft above grade22.5 sq ftMust conform to setback regulations for non-residential use in district
Freestanding Sign (Principal Non-Residential Use)Not listed8 sq ftFront yard as per zoning and sign code
Home Occupation SignNot listed2 sq ft (aggregate with occupant ID sign, max total of 2 sq ft; if >1 sq ft, must meet front setback)Must meet front yard setback if over 1 sq ft

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for BethlehemFull Coverage

Sign Types Covered

36

  • Wall/Projecting Sign (Business Use)
  • Sandwich Board/Sidewalk Sign
  • Wall Sign (Principal Non-Residential Use)
  • Freestanding Sign (Principal Non-Residential Use)
  • +2 more types

Zoning Districts

13

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Bethlehem

City WebsiteMunicipal Code1 permit application link available

Frequently Asked Questions

In Bethlehem, the height limit for Freestanding Sign in the General Commercial District (CG) and other zoning districts is 30 ft typical; 40 ft shopping center (Sec. 1320.09(a)(3)-(6)). The height limit for Wall Sign (Principal Non-Residential Use) in the Rural Residential District (RR) and other zoning districts is 25 ft above grade (Sec. 1320.08(a)(11)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Bethlehem require a permit. From the submission notes on this page: Any sign requiring review as part of a special exception (e.g., Article 1304.04 for corner lots and office conversions) must be submitted for approval, with area and illumination limits, as part of the special exception process. Run a code check for an exact address to see the permit requirements for that zone.

Bethlehem's sign code covers 36 sign types, including Wall/Projecting Sign (Business Use), Sandwich Board/Sidewalk Sign, Wall Sign (Principal Non-Residential Use), and Freestanding Sign (Principal Non-Residential Use). Most commercial signs need a permit. The ordinance lists 5 exemptions. One of them: Directional devices as may be required by the Federal Aviation Authority are exempt from certain placement limitations. The full list is on this page.

In Bethlehem, Freestanding Sign in the General Commercial District (CG) and other zoning districts must be set back 5 ft from right-of-way (Sec. 1320.09(a)(3)-(6)). The ordinance adds other placement rules for this sign type, listed in the table on this page. Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Bethlehem's sign ordinance that cover digital, changing, or flashing signs: Flashing, blinking, mechanically moving, twinkling or animated signs of any type are prohibited. Strobe lighting shall be prohibited, except for non-advertising seasonal lights between October 25th and January 10th. Digital signs/off-premises electronic message centers must conform to minimum change time, brightness, and spacing limits (minimum 10 seconds per slide and minimum 1,000 feet from any other off-premises sign of this type). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Bethlehem Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Bethlehem, Pennsylvania, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Bethlehem, Pennsylvania Sign Rules at a Glance

Bethlehem, Pennsylvania regulates 36 sign types across 13 zoning districts. Wall Signs (Principal Non-Residential Use) in the Rural Residential District (RR) and other zoning districts are capped at 25 ft above grade and 22.5 sq ft (Sec. 1320.08(a)(11)). Most commercial signs in Bethlehem require a permit.

Detailed Sign Ordinance Requirements for Bethlehem, Pennsylvania

Sign Rules by Zoning District in Bethlehem (13 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
Rural Residential District (RR), Residential Overlay District - Friedensville Road (RR-F), Residential Overlay District - Township Line Road (RR-T), Single Family Residential District (RS), Medium Density Residential District (RG), High Density Residential District (RT), Residential Retirement Complex District (R-RC)1325 ft above grade50 sq ft per principal building side facing streetNot listed
General Regulations For All Zones4Not listedNot listedNot listed
Institutional District (I), Institutional Overlay District (I-O)48 ft (I-O, commercial)40 sq ft per principal building side facing street (I); see requirements below for I-ONot listed
Central Business District (CB)330 ft (40 ft for Shopping Center)50 sq ft (typical lot); 150 sq ft (shopping center CS district)Not listed
General Commercial District (CG), Limited Commercial District (CL), Shopping Center District (CS)330 ft typical; 40 ft shopping center50 sq ft (CG/CL, typical); 150 sq ft/side for CS Shopping Center; shopping centers get one per entry (up to 4, per schedule)Not listed
Office-Research Center District (CM), Planned Industrial District (PI), Light Industrial District (LI), Industrial District (IN), Industrial Overlay District (IN-O)325 ft above grade (wall sign), or top of roof line375 sq ft (LI/IN/PI); 40 ft tallNot listed
Industrial Redevelopment District (IR), Industrial Redevelopment - Residential Option District (IR-R)230 ft typical50 sq ft (typical non-residential)Not listed
Landmark Conservation and Traditional Neighborhood Development Overlay District (CM-LTN)1Not listedNot listedNot listed
Mixed Use Commercial District (CMU), Office Mixed Use District (OMU)1Not listedSign requirements per Section 1320.09 apply, unless in a Planned Office Commercial Development (POCD), see below for POCD.Not listed
Floodway and Flood Fringe Districts1Not listedNot listedNot listed
Airport Approach Overlay Zones1Not listedNot listedNot listed
Steep Slope Provisions District1Not listedNot listedNot listed
SH Student Housing and Student Home Overlay Zoning District (SH)1Not listed1 sq ft (student home); 2 sq ft (home occupation, aggregate with any occupant ID sign)Not listed

Zone-by-Zone Sign Requirements in Bethlehem(sample of 3 of 13 zones)

Rural Residential District (RR), Residential Overlay District - Friedensville Road (RR-F), Residential Overlay District - Township Line Road (RR-T), Single Family Residential District (RS), Medium Density Residential District (RG), High Density Residential District (RT), Residential Retirement Complex District (R-RC)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall Sign (Principal Non-Residential Use)25 ft above grade22.5 sq ftNot listedMust conform to setback regulations for non-residential use in districtOne per street frontageMain wall of principal building; projecting max 3.5 ft from wall; min 7.5 ft above gradeNot listedUnlock§1320.08(a)(11)
Freestanding Sign (Principal Non-Residential Use)Not listed8 sq ftNot listedFront yard as per zoning and sign code1 per street frontageOn lot occupied by non-residential useNot listedUnlock§1320.08(a)(3), (13)
Home Occupation SignNot listed2 sq ft (aggregate with occupant ID sign, max total of 2 sq ft; if >1 sq ft, must meet front setback)Not listedMust meet front yard setback if over 1 sq ft1On building or propertyNot listedUnlock§1320.08(a)(9)
Bed and Breakfast Inn SignNot listed4 sq ftNot listedNot listed1 per street frontageOn propertyNot listedUnlock§1320.08(a)(2)
Sale/Lease/Rental Sign (Temporary)Not listed6 sq ftNot listedNot listed1 per frontageOn propertyNot listedUnlock§1320.08(a)(4)
Trespassing/Private Property SignNot listed2 sq ftNot listedNot listedNo limitOn propertyNot listedUnlock§1320.08(a)(5)
Apartment Development SignNot listed20 sq ftNot listedNot listed1 per frontageOn propertyNot listedUnlock§1320.08(a)(10)
Home Occupation / Occupant Identification SignNot listed2 sq ft (aggregate with ID sign: max 2 sq ft; >1 sq ft must meet front yard setback)Not listedIf >1 sq ft, must meet front yard setback1On property (wall or near entrance)Not listedUnlock§1320.08(a)(9)

Central Business District (CB)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall/Projecting Sign (Business Use)25 ft above grade (or top of building for wall sign)20% of area of the exterior building face (including windows/doors/cornices); max 200 sq ftNot listedNot listedNot listedMain wall of principal building/side or rear wall only if abutting street, driveway or parking areaNot listedUnlock§1320.09(a)(2), (v)
Freestanding Sign (Business Use)30 ft (40 ft for Shopping Center)50 sq ft (typical lot); 150 sq ft (shopping center CS district)Not listedNone required in CB district1 per street or combined in singleOn lot; per frontageNot listedUnlock§1320.09(a)(3), (v), (vi)
Sandwich Board/Sidewalk Sign4 ft2 ft wide x 4 ft high (8 sq ft per side)2 ftNone, but must maintain 5 ft clear1 per owner frontage/businessOn public sidewalk or private frontage immediately adjacent to businessNot listedUnlock§1320.09(c)

General Commercial District (CG), Limited Commercial District (CL), Shopping Center District (CS)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall/Projecting Sign (Business Use)25 ft above grade20% of area of external building face (including windows/doors/cornices); max 200 sq ft (CL/CG)Not listedNone (CL/CB)Per principal building sideMain wall of principal building; projecting: may not >3.5 ft from wall, min 8 ft above gradeNot listedUnlock§1320.09(a)(2)-(6)
Freestanding Sign30 ft typical; 40 ft shopping center50 sq ft (CG/CL, typical); 150 sq ft/side for CS Shopping Center; shopping centers get one per entry (up to 4, per schedule)Not listed5 ft from right-of-way; clear sight triangle applies (10 ft in PI); none in CL/CB1 per frontage or combinedOn lot, per frontageNot listedUnlock§1320.09(a)(3)-(6)
Sandwich Board/Sidewalk Sign4 ft2 ft wide x 4 ft high2 ftNot listed1 per businessOn public sidewalk or private propertyNot listedUnlock§1320.09(c)

PermitPal covers all 13 zoning districts in Bethlehem. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Bethlehem

  • No sign shall be so located or arranged that it interferes with traffic through glare, blocking of reasonable sight lines for streets, sidewalks, or driveways, confusion with a traffic control device (by reason of color, location, shape or other characteristic), or through any other means.
  • No sign shall violate the corner visibility restrictions in Section 1318.06, except that a sign pole with a width of up to 18 inches may intrude into a sight triangle.
  • No sign (except those of a duly constituted governmental body, including traffic signs and similar regulatory notices) shall be allowed within a street right-of-way unless specifically authorized by other ordinances and regulations of the City.
  • No sign (except such directional devices as may be required by the Federal Aviation Authority) shall be placed, inscribed or supported upon the roof that the sign abuts or upon any structure which extends above the roof of any building, except that a sign may be attached to a parapet wall that extends up to 5 feet above the roof and which is architecturally integrated with the building.
  • Any vehicle or trailer to which a sign is affixed in such a manner that the carrying of such sign or signs no longer is incidental to the vehicle's primary purpose but becomes a primary purpose in itself shall be considered a free-standing sign and as such be subject to the provisions regarding free-standing signs in the district in which such vehicle or trailer is located.
  • Flashing, blinking, mechanically moving, twinkling or animated signs of any type are prohibited. Strobe lighting shall be prohibited, except for non-advertising seasonal lights between October 25th and January 10th.
  • Aerial lasers and spotlights aimed into the sky shall not be allowed as promotional devices.
  • Signs existing at the time of passage of this Ordinance which do not conform to the requirements of the Ordinance shall be considered non-conforming signs. However, non-conforming signs may be repainted, repaired (including lighting) or replaced provided such repainted, repaired or replaced signs do not exceed the dimensions of the existing sign. Non-conforming signs, once removed for a period of 90 days, may be replaced only with signs which conform to provisions of this Ordinance.
  • No sign shall be so located as to violate minimum setbacks, buffer yard, or clear sight triangle requirements as specified in this Ordinance.
  • No new sign shall be internally illuminated in specified instances, such as in residential or historic areas, as referenced in sign plan approvals and special exceptions.
  • Digital signs/off-premises electronic message centers must conform to minimum change time, brightness, and spacing limits (minimum 10 seconds per slide and minimum 1,000 feet from any other off-premises sign of this type).
  • No sign shall be placed on city-owned land, or within a public street right-of-way except as specifically authorized.
  • No sign in a residential district shall be illuminated between the hours of 10:00 P.M. and 7:00 A.M.

Exempt Signs in Bethlehem

  • Flags of any governmental unit or branch or of any charitable or religious organization, interior signs not visible from a public right-of-way or adjoining property, and cornerstones built in or attached to a wall of a building are excluded from sign regulations.
  • Official traffic signs and other official Federal, State, County and City governmental signs are permitted in all districts.
  • Directional devices as may be required by the Federal Aviation Authority are exempt from certain placement limitations.
  • Signs necessary for the direction, regulation and control of traffic, street name signs, legal notices, warnings at railroad crossings, and other official signs which are similarly authorized or erected by a duly constituted governmental body are exempt.
  • Temporary signs for mechanics, tradespersons, or artisans while performing work are allowed, provided they are removed upon completion of work.

Sign Plan & Submission Notes for Bethlehem

  • All on-premises signs over 6 square feet in area, all projecting signs extending into the public right of way, and all off-premises signs regardless of size shall require the issuance of a zoning permit before erection or replacement.
  • A permit may also be required in other circumstances under the Construction Code.
  • All signs must comply with all of the regulations contained herein, regardless of whether a permit is required.
  • Any sign requiring review as part of a special exception (e.g., Article 1304.04 for corner lots and office conversions) must be submitted for approval, with area and illumination limits, as part of the special exception process.
  • For large mixed-use/commercial developments (certain districts, e.g. CMU, POCD), an overall coordinated sign plan/design must be submitted as part of master/site plan approval.
  • In Historic Architectural Review Board (HARB) or Historic Conservation Commission (HCC) areas, all proposed signs must comply with applicable historic review and approval requirements.
  • Any painted wall sign that was not visible for the previous 10 years shall be considered abandoned, and shall not be repainted with a new message if it becomes visible because of a building demolition.
  • A sign plan or site plan must be submitted for City Planning Commission review (see Section 1322.02) in cases involving a special exception application or use variance for a new principal non-residential or multi-family building, an addition of 10 or more off-street parking spaces, or 10,000 square feet or greater of new principal non-residential building space, or when otherwise required by the Zoning Officer.

Source: other municipal code