Questions? Call us at (262) 218-2915

Sign Regulations in Honesdale Borough, Pennsylvania

Honesdale Borough, Pennsylvania has specific sign regulations covering 28 sign types across 5 zoning districts. Regulated sign types include Building Number Sign, Incidental Commercial Sign, Traffic Directional Sign. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 28, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Honesdale Borough, Pennsylvania

Sample Sign Requirements in Honesdale Borough

Sign TypeMax HeightMax AreaSetback
Building Number SignNot listed1 square footNot listed
Incidental Commercial SignNot listed1 square foot each (8 square feet combined)Not listed
Traffic Directional SignNot listed2 square feetNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Honesdale BoroughFull Coverage

Sign Types Covered

28

  • Building Number Sign
  • Incidental Commercial Sign
  • Traffic Directional Sign
  • Trespassing Sign
  • +2 more types

Zoning Districts

5

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Illumination rules

Official Resources for Honesdale Borough

Municipal Code2 permit application links available

Frequently Asked Questions

We haven't published Honesdale Borough's sign height limits on this page yet. Run a code check for an exact address to see them.

Most commercial signs in Honesdale Borough require a permit. From the submission notes on this page: The sign permit application must include two copies of plans and specifications for each sign. Run a code check for an exact address to see the permit requirements for that zone.

Honesdale Borough's sign code covers 28 sign types, including Building Number Sign, Incidental Commercial Sign, Traffic Directional Sign, and Trespassing Sign. Most commercial signs need a permit. The ordinance lists 7 exemptions. One of them: Pennsylvania and U.S. flags shall be exempt. The full list is on this page.

We haven't published Honesdale Borough's sign setback rules on this page yet. Run a code check for an exact address to see them.

Rules in Honesdale Borough's sign ordinance that cover digital, changing, or flashing signs: In the case of advertising and electronic signs, engineering data as required for compliance must be submitted. All electronic message signs must include landscaping subject to review by the Borough Planning Commission and approval by the Zoning Hearing Board. Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Honesdale Borough Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Honesdale Borough, Pennsylvania, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Honesdale Borough, Pennsylvania Sign Rules at a Glance

Honesdale Borough, Pennsylvania regulates 28 sign types across 5 zoning districts. Wayfinding Signs in the C-1 District are capped at 3 square feet (Sec. 210-20M). Most commercial signs in Honesdale Borough require a permit.

Detailed Sign Ordinance Requirements for Honesdale Borough, Pennsylvania

Sign Rules by Zoning District in Honesdale Borough (5 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
R-1 District, R-2 District, R-3 District, R-4 District, R-5 District, R-6 District14Not listed24 square feetNot listed
A-1 District, A-2 District18Not listed40 square feetNot listed
C-1 District23Not listed150 square feet per faceNot listed
C-2 District, ID District, Highway Commercial District (C-2)25Not listed300 sq ft; signs within 100 feet of residential districts limited to 100 sq ftNot listed
General Regulations For All Zones2Not listedNot listedNot listed

Zone-by-Zone Sign Requirements in Honesdale Borough(sample of 3 of 5 zones)

A-1 District, A-2 District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Contractor SignNot listed12 square feetNot listedNot listed2On property where construction is taking placeNot listedUnlock§ 210-20M
Farm Products SignNot listed12 square feetNot listedNot listed2On propertyNot listedUnlock§ 210-20M
Real Estate SignNot listed12 square feetNot listedNot listed2On property being advertisedNot listedUnlock§ 210-20M
Yard Sale SignNot listed12 square feetNot listedNot listed2On propertyNot listedUnlock§ 210-20M; § 210-20F(4)
Home Occupation SignNot listed4 square feetNot listedNot listed1On propertyNot listedUnlock§ 210-20M
Residential Development SignNot listed40 square feetNot listedNot listed1On property for residential developmentNot listedUnlock§ 210-20M
Freestanding SignNot listed40 square feetNot listedNot listed2On property, for permitted or existing nonresidential usesNot listedUnlock§ 210-20M
Wall SignNot listed40 square feetNot listedNot listed2On building exteriorNot listedUnlock§ 210-20M; § 210-20E(10)

C-1 District

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Contractor SignNot listed32 square feetNot listedNot listed2On propertyNot listedUnlock§ 210-20M
Real Estate SignNot listed24 square feetNot listedNot listed2On property being advertisedNot listedUnlock§ 210-20M
Yard Sale SignNot listed24 square feetNot listedNot listed2On propertyNot listedUnlock§ 210-20M; § 210-20F(4)
Blade SignNot listed3 square feet per streetfrontNot listedNot listed1 per streetfrontOn each streetfrontNot listedUnlock§ 210-20M
Wayfinding SignNot listed3 square feetNot listedNot listed2On property as neededNot listedUnlock§ 210-20M
Bench SignNot listed6 square feet eachNot listedNot listed2On benchesNot listedUnlock§ 210-20M
Home Occupation SignNot listed4 square feetNot listedNot listed1On propertyNot listedUnlock§ 210-20M
Residential Development SignNot listed40 square feetNot listedNot listed1On property for residential developmentNot listedUnlock§ 210-20M

C-2 District, ID District, Highway Commercial District (C-2)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Contractor SignNot listed40 square feetNot listedNot listed2On propertyNot listedUnlock§ 210-20M
Real Estate SignNot listed32 square feetNot listedNot listed2On property being advertisedNot listedUnlock§ 210-20M
Yard Sale SignNot listed24 square feetNot listedNot listed2On propertyNot listedUnlock§ 210-20M; § 210-20F(4)
Blade SignNot listed4 square feet per streetfrontNot listedNot listed1 per streetfrontOn each streetfrontNot listedUnlock§ 210-20M
Wayfinding SignNot listed6 square feetNot listedNot listed2On property as neededNot listedUnlock§ 210-20M
Bench SignNot listed6 square feet eachNot listedNot listed2On benchesNot listedUnlock§ 210-20M
Home Occupation SignNot listed4 square feetNot listedNot listed1On propertyNot listedUnlock§ 210-20M
Residential Development SignNot listed40 square feetNot listedNot listed1On property for residential developmentNot listedUnlock§ 210-20M

PermitPal covers all 5 zoning districts in Honesdale Borough. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Honesdale Borough

  • All signs not expressly permitted or exempted under this section from regulation are prohibited in the Borough.
  • Roof signs and commercial signs intended to resemble official highway signs or uniform traffic control devices are prohibited.
  • Feather signs are specifically prohibited due to pedestrian and other hazards.
  • No sign shall be erected, constructed, or maintained so as to obstruct any fire escapes, required exit, window, door opening, or wall opening intended as a means of ingress or egress.
  • No sign shall be erected, constructed, or maintained so as to interfere with any opening required for ventilation.
  • All signs shall be located to maintain horizontal and vertical clearance of all electrical power lines and communication lines, as required by the National Electrical Code.
  • All signs and supporting structures shall maintain clearance and avoid interference with all surface and underground facilities and conduits for storm drainage, water, sewage, gas, electricity, or communications.
  • No sign shall be erected, constructed, or maintained so as to interfere with any existing warning or instructional sign.
  • No sign shall be erected so as to interfere with or to confuse traffic, to present any traffic hazard, or to obstruct the vision of motorists, and all signs shall comply with clear sight triangle requirements.
  • Signs attached to any public infrastructure or utility poles, including but not limited to light poles, electric poles, fences, street signs, stop signs or parking meters or signs placed in the public right-of-way except as permitted herein (such as banners approved by the Borough) are strictly prohibited and shall be immediately removable by the owner of the affected public or utility property.
  • No garage or yard sale signs can be posted on trees, poles, shrubs, vehicles, dwellings or structures.
  • No signs are to be attached to Borough street poles, PP&L poles, or state route signs.

Exempt Signs in Honesdale Borough

  • Signs that are small, unobtrusive, and incidental to principal use of lots on which they are located, subject to the substantive requirements of this section, but without a requirement for permits (e.g., building number signs, hazard warning signs, noncommercial flags).
  • Certain signs allowed without permits, though subject to the standards of this section, as listed per zoning district on the Schedule of Sign Regulations.
  • Permits shall not be required for routine maintenance or changing of the parts or copy of a sign, provided the maintenance or change of parts or copy does not alter the sign surface area or height, or otherwise render the sign nonconforming.
  • Pennsylvania and U.S. flags shall be exempt.
  • Garden and house flags used for decorative purposes in conjunction with residential uses shall also be exempt.
  • Murals placed on any building, as provided on the Schedule of Sign Regulations, shall not require permits but must comply with illumination standards.
  • Historical markers, placement of the year of construction or name of a builder, and retention or repurposing of historical signage relating to a building’s previous use are not considered signage for advertising purposes and are exempt from maximum signage calculations.

Sign Plan & Submission Notes for Honesdale Borough

  • A sign permit is required before the erection, re-erection, construction, alteration, placing, or installation of all signs identified as 'Allowed with Permits from Zoning Officer' on the Schedule of Sign Regulations.
  • The sign permit application must include two copies of plans and specifications for each sign.
  • Sign permit applications require, at a minimum: applicant and property owner contact information, the location of the sign, a sketch plan, sign plans and specifications, owner consent, and any additional information required by the Zoning Officer.
  • In the case of advertising and electronic signs, engineering data as required for compliance must be submitted.
  • For developments with two or more nonresidential occupants, the location and arrangement of all building name and address signs are subject to review and approval of the Zoning Officer.
  • Any sign permit not completed within 90 days becomes null and void unless extended by the Zoning Officer.
  • All electronic message signs must include landscaping subject to review by the Borough Planning Commission and approval by the Zoning Hearing Board.
  • Common directory signs require documentation of the organization that will maintain the sign and written permission from the property owner with the application.
  • Temporary signs associated with civic, philanthropic, educational, or religious event campaigns must comply with section requirements but may be exempt from strict area or time limitations.

Source: ecode360 municipal code