Sign Regulations in Steelton Borough, Pennsylvania
Steelton Borough, Pennsylvania has specific sign regulations covering 20 sign types across 4 zoning districts. Regulated sign types include Business Identification Sign (lot with <10% building coverage), Business Identification Sign (lot with ≥10% building coverage) - Lower Level, Business Identification Sign (lot with ≥10% building coverage) - Upper Level. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: April 28, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Steelton Borough, Pennsylvania
Sample Sign Requirements in Steelton Borough
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Real Estate Sign | Not listed | 6 sq ft | Not listed |
| Development Sign | Not listed | 20 sq ft | Not listed |
| Directional Sign | Not listed | 6 sq ft | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
20
- Business Identification Sign (lot with <10% building coverage)
- Business Identification Sign (lot with ≥10% building coverage) - Lower Level
- Business Identification Sign (lot with ≥10% building coverage) - Upper Level
- Freestanding Sign - Movable (A-frame, Sandwich Board)
- +2 more types
Zoning Districts
4
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Steelton Borough
Other Cities in Pennsylvania
Frequently Asked Questions
In Steelton Borough, the height limit for Freestanding Sign - Nonmovable in the Commercial districts, Industrial districts is 25 ft (top of sign); sign face max 4 ft high, 5 ft wide (Sec. 120-66M(2)(a)-(j)). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Steelton Borough require a permit. From the submission notes on this page: An application for sign permit requires: a detailed scale drawing of the sign and its location, description of type/construction/manner/method of installation/materials, written authorization from the property owner if other than applicant, and a permit fee. Run a code check for an exact address to see the permit requirements for that zone.
Steelton Borough's sign code covers 20 sign types, including Business Identification Sign (lot with <10% building coverage), Business Identification Sign (lot with ≥10% building coverage) - Lower Level, Business Identification Sign (lot with ≥10% building coverage) - Upper Level, and Freestanding Sign - Movable (A-frame, Sandwich Board). Most commercial signs need a permit. The ordinance lists 5 exemptions. One of them: Official signs are exempt from both permit and fee requirements. The full list is on this page.
This page doesn't list a single setback distance for signs in Steelton Borough. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Rules in Steelton Borough's sign ordinance that cover digital, changing, or flashing signs: No sign shall be permitted which rotates and/or causes interruption or flashing of light. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Steelton Borough Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Steelton Borough, Pennsylvania, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required · Get results in seconds
Steelton Borough, Pennsylvania Sign Rules at a Glance
Steelton Borough, Pennsylvania regulates 20 sign types across 4 zoning districts. Business Specials/Event Signs in the C-1, C-2 zoning districts are capped at 18 in tall, 3 sq ft, and 24 in wide (Sec. 120-66O(1)-(7)). Most commercial signs in Steelton Borough require a permit.
Detailed Sign Ordinance Requirements for Steelton Borough, Pennsylvania
Sign Rules by Zoning District in Steelton Borough (4 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| Residential districts | 8 | Not listed | 20 sq ft | Not listed |
| Commercial districts, Industrial districts | 8 | 30 inches | 75 sq ft total (all temporary signs combined); individual sign: 75 sq ft max | Not listed |
| C-1, C-2 | 7 | 30 inches | 75 sq ft total (all temporary signs combined); individual sign: 75 sq ft max | Not listed |
| General Regulations For All Zones | 4 | Not listed | 20 sq ft | Not listed |
Zone-by-Zone Sign Requirements in Steelton Borough(sample of 3 of 4 zones)
Residential districts
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Real Estate Sign | Not listed | 6 sq ft | Not listed | Not listed | 2 per property, 2 per frontage if property has multiple frontages | On premises being advertised | Not listed | Unlock | §120-63A(1)-(2) |
| Development Sign | Not listed | 20 sq ft | Not listed | Not listed | 2 per property, 2 per frontage if property has multiple frontages | On premises being developed | Not listed | Unlock | §120-63B(1)-(2) |
| Directional Sign | Not listed | 6 sq ft | 4 ft | Not listed | 1 per 500 ft street frontage | Not on premises under development | Not listed | Unlock | §120-63C(1)-(2) |
| Sold/Rented Sign | Not listed | 6 sq ft | Not listed | Not listed | 2 per property, 2 per frontage if property has multiple frontages | On premises | Not listed | Unlock | §120-63D |
| Contractor Sign | Not listed | 12 sq ft | Not listed | Not listed | Not listed | On premises while work is being performed | Not listed | Unlock | §120-63E(1)-(2) |
| No Trespassing/Private Driveway Sign | Not listed | 2 sq ft | Not listed | Not listed | Not listed | On premises | Not listed | Unlock | §120-63F |
| Institution Sign | Not listed | 20 sq ft | Not listed | Not listed | 2 per property, 2 per frontage if property has multiple frontages | On premises for schools, colleges, churches, hospitals, sanitariums or similar | Not listed | Unlock | §120-63G(1)-(2) |
| Home Occupation Sign | Not listed | 0.75 sq ft | 18 inches | Not listed | 1 per home occupation | On premises | Not listed | Unlock | §120-63H |
Commercial districts, Industrial districts
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Business Identification Sign (lot with <10% building coverage) | Not listed | Not listed | Not listed | Not listed | Not listed | On building or lot oriented/affixed | Not listed | Unlock | §120-64B, §120-64C(6), §120-64C(4) |
| Business Identification Sign (lot with ≥10% building coverage) - Lower Level | Not listed | Not listed | Not listed | Not listed | Total area reduced by 1/5 for each additional sign | On lower two stories or 26 ft of building, or freestanding | Not listed | Unlock | §120-64C(1), §120-64C(3), §120-64C(6), §120-64C(4) |
| Business Identification Sign (lot with ≥10% building coverage) - Upper Level | Not listed | Not listed | Not listed | Not listed | Total area reduced by 1/5 for each additional sign | Above second story on building | Not listed | Unlock | §120-64C(2), §120-64C(3), §120-64C(4) |
| Freestanding Sign - Movable (A-frame, Sandwich Board) | 4 ft | Not listed | 2 ft | Not listed | 1 per business | On sidewalk adjacent to business property | Not listed | Unlock | §120-66M(1)(a)-(e), (b)[1]-[6], (e)-(f) |
| Freestanding Sign - Nonmovable | 25 ft (top of sign); sign face max 4 ft high, 5 ft wide | Not listed | 5 ft (for face); location overall 25 ft high max at top | Building must be set back 30 ft or more from sidewalk/street | 1 per property | On property, set back at least 30 ft from sidewalk/street, must be outside the sidewalk area | Not listed | Unlock | §120-66M(2)(a)-(j) |
| Temporary Sign (Nonresidential Area) | 30 inches | 75 sq ft total (all temporary signs combined); individual sign: 75 sq ft max | 30 ft | Not listed | Not listed | On or outside building (exterior must be weatherproof) | Not listed | Unlock | §120-66N(1)-(8) |
| Business Specials/Event Sign | 18 in | 3 sq ft | 24 in | Not listed | Not listed | Securely attached to building | Not listed | Unlock | §120-66O(1)-(7) |
| Billboard (Industrial, Commercial other than C-1, C-2) | 20 ft | Not listed | 25 ft (per sign face) | 30 ft front setback or to established building line (lesser); 50 ft from residential district if visible and facing | 1 per street frontage | Set back 30 ft from front lot line or to the established building line, whichever is less; only in commercial and industrial districts except C-1 and C-2 | Not listed | Unlock | §120-65A-E, §120-66H |
C-1, C-2
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Business Identification Sign (lot with <10% building coverage) | Not listed | Not listed | Not listed | Not listed | Not listed | On building or lot oriented/affixed | Not listed | Unlock | §120-64B, §120-64C(6), §120-64C(4) |
| Business Identification Sign (lot with ≥10% building coverage) - Lower Level | Not listed | Not listed | Not listed | Not listed | Total area reduced by 1/5 for each additional sign | On lower two stories or 26 ft of building, or freestanding | Not listed | Unlock | §120-64C(1), §120-64C(3), §120-64C(6), §120-64C(4) |
| Business Identification Sign (lot with ≥10% building coverage) - Upper Level | Not listed | Not listed | Not listed | Not listed | Total area reduced by 1/5 for each additional sign | Above second story on building | Not listed | Unlock | §120-64C(2), §120-64C(3), §120-64C(4) |
| Freestanding Sign - Movable (A-frame, Sandwich Board) | 4 ft | Not listed | 2 ft | Not listed | 1 per business | On sidewalk adjacent to business property | Not listed | Unlock | §120-66M(1)(a)-(e), (b)[1]-[6], (e)-(f) |
| Freestanding Sign - Nonmovable | 25 ft (top of sign); sign face max 4 ft high, 5 ft wide | Not listed | 5 ft (for face); location overall 25 ft high max at top | Building must be set back 30 ft or more from sidewalk/street | 1 per property | On property, set back at least 30 ft from sidewalk/street, must be outside the sidewalk area | Not listed | Unlock | §120-66M(2)(a)-(j) |
| Temporary Sign (Nonresidential Area) | 30 inches | 75 sq ft total (all temporary signs combined); individual sign: 75 sq ft max | 30 ft | Not listed | Not listed | On or outside building (exterior must be weatherproof) | Not listed | Unlock | §120-66N(1)-(8) |
| Business Specials/Event Sign | 18 in | 3 sq ft | 24 in | Not listed | Not listed | Securely attached to building | Not listed | Unlock | §120-66O(1)-(7) |
PermitPal covers all 4 zoning districts in Steelton Borough. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Steelton Borough
- Signs must not be hand-written.
- Signs must not be constructed of non-durable materials or allowed to become dilapidated.
- Signs shall not be placed in a position that will cause danger to street traffic by obscuring the view.
- Signs, other than an official sign, shall not be erected within the lines of any street.
- Signs and banners (except banners extending across streets under specific provisions) that project beyond property lines or over public sidewalk areas shall be a maximum width and height of four feet and at a minimum height above the sidewalk of 10 feet.
- Signs shall not project above the height limit permitted in any district.
- No sign shall be permitted which rotates and/or causes interruption or flashing of light.
- All signs erected within the right-of-way of a state highway shall comply with Pennsylvania Department of Transportation regulations.
- Mobile signs are prohibited in all districts, except as a specific temporary use for new principal commercial uses in certain zones for up to 60 days.
- Rooftop business identification signs are prohibited; no rooftop signs shall be rented as billboards.
- No advertising sign shall be erected upon the roof of any building.
- All nonconforming signs, billboards or advertising signboards shall be made to conform to all pertinent regulations or be removed within two years after the effective date of the chapter, except legal nonconforming business identification signs.
- Once an existing nonconforming sign is removed, it shall only be replaced with a sign that conforms to this chapter.
- No temporary sign with an area of over 75 square feet is permitted.
- No temporary sign shall exceed 30 inches in height or 30 feet in width.
Exempt Signs in Steelton Borough
- Official signs are exempt from both permit and fee requirements.
- Temporary signs are exempt from both permit and fee requirements.
- A permit is not required for the erection, alteration, or maintenance of any signs permitted in a residential district (except a home occupation sign requires a permit).
- Garage sale and charitable event signs do not require a permit.
- Business identification signs, real estate signs, incidental temporary exterior signs, identification signs and political signs (as defined), as well as attraction signage installed by local or state government entities in rights-of-way for directing to specific sites, are exempt from the Off-Premises Sign Tax.
Sign Plan & Submission Notes for Steelton Borough
- No explicit mention of a required master sign plan or sign plan process is present in the provided text.
- A permit is required for the erection, alteration, or reconstruction of billboards, advertising signboards, including poster panels, bulletins, temporary or permanent business signs and the like, except for signs exempted under §120-66I and §120-69.
- An application for sign permit requires: a detailed scale drawing of the sign and its location, description of type/construction/manner/method of installation/materials, written authorization from the property owner if other than applicant, and a permit fee.
- No person shall erect, cause to be erected, change or alter any sign on any property within the Borough until a permit has been issued by the Zoning Officer, except for exempt signs as outlined.
- When a permit is required, written permission from the building owner for the placement of the sign must be provided to the Zoning Officer.
Source: ecode360 municipal code