Sign Regulations in Waynesburg, Pennsylvania
Waynesburg, Pennsylvania has specific sign regulations covering 17 sign types across 8 zoning districts. Regulated sign types include Wall Sign, Monument Sign (Freestanding, Setback 25+ ft.), Pole Sign (Freestanding, Setback 25+ ft.). Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.
Data last verified: May 9, 2025
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
Sign Regulation Overview for Waynesburg, Pennsylvania
Sample Sign Requirements in Waynesburg
| Sign Type | Max Height | Max Area | Setback |
|---|---|---|---|
| Temporary Construction Sign | Not listed | 12 sq. ft. | Not listed |
| Portable Sign (Sandwich Board Sign) | 4 ft. | 10 sq. ft. | Not listed |
| Temporary Real Estate Sign (Residential) | Not listed | 6 sq. ft. | Not listed |
* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.
Sign Types Covered
17
- Wall Sign
- Monument Sign (Freestanding, Setback 25+ ft.)
- Pole Sign (Freestanding, Setback 25+ ft.)
- Projecting Sign
- +2 more types
Zoning Districts
8
Different zoning districts with specific sign regulations
Data Includes
- Permit requirements
- Height restrictions
- Illumination rules
Official Resources for Waynesburg
Other Cities in Pennsylvania
Frequently Asked Questions
In Waynesburg, the height limit for Pole Sign (Freestanding, Setback 25+ ft.) in the Non-Residential Districts (B-1, M-1, U-1, U-2) is 10 ft (Sec. 5-505.2(2)(a)(ii)(b)). Maximum sign heights range from 4 ft to 10 ft across zoning districts. Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.
Most commercial signs in Waynesburg require a permit. From the submission notes on this page: There is no mention of a master sign plan or sign plan submittal required for all signs across all zones in the provided ordinance text. Run a code check for an exact address to see the permit requirements for that zone.
Waynesburg's sign code covers 17 sign types, including Wall Sign, Monument Sign (Freestanding, Setback 25+ ft.), Pole Sign (Freestanding, Setback 25+ ft.), and Projecting Sign. Most commercial signs need a permit. The ordinance lists 9 exemptions. One of them: Temporary signs are exempt. The full list is on this page.
This page doesn't list a single setback distance for signs in Waynesburg. The tables on this page quote the ordinance's placement rules for the sign types we sampled. Run a code check for an exact address to see the setback that applies there.
Waynesburg's sign code lists Digital Sign / Electronically Changing Message Sign as a sign type, but this page doesn't quote the code's rules for digital or LED signs. Run a code check for an exact address to see the full illumination rules for that zone.
Ready to Research Waynesburg Sign Permits?
Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Waynesburg, Pennsylvania, with citations from the municipal code.
Need the sign code for this address?
PermitPal is an independent research tool for sign companies. We are not the city's permit office.
No credit card required ยท Get results in seconds
Waynesburg, Pennsylvania Sign Rules at a Glance
Waynesburg, Pennsylvania regulates 17 sign types across 8 zoning districts. Projecting Signs in the Business Districts (B-1) are capped at 2 ft tall, 6 sq ft, and 3 ft wide (Sec. 5-505.2(2)(a)(iii)). Most commercial signs in Waynesburg require a permit.
Detailed Sign Ordinance Requirements for Waynesburg, Pennsylvania
Sign Rules by Zoning District in Waynesburg (8 zones)
| Zoning District | Sign Types Regulated | Max Height | Max Area | Permit Required |
|---|---|---|---|---|
| General Regulations For All Zones | 7 | 4 ft. | 20 sq. ft. | Not listed |
| Residential Districts (R-1, R-2, R-3) | 4 | 6 ft. | 20 sq. ft. | Not listed |
| Non-Residential Districts (B-1, M-1, U-1, U-2) | 7 | 10 ft. | 75% of total window area | Not listed |
| Business Districts (B-1) | 7 | 10 ft. | 75% of total window area | Not listed |
| Business Districts (B-2) | 7 | 10 ft. | 75% of total window area | Not listed |
| Manufacturing Districts (M-1) | 7 | 10 ft. | 75% of total window area | Not listed |
| U-1 | 7 | 10 ft. | 75% of total window area | Not listed |
| U-2 | 7 | 10 ft. | 75% of total window area | Not listed |
Zone-by-Zone Sign Requirements in Waynesburg(sample of 3 of 8 zones)
Non-Residential Districts (B-1, M-1, U-1, U-2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | 25 sq. ft. | Not listed | Not listed | May have up to 3 signs on a property (total for all types), see general requirement. | On wall of building. | Not listed | Unlock | Sec. 5-505.2(2)(a)(i), 5-505.2(2)(c), 5-505.2(4)(b) |
| Monument Sign (Freestanding, Setback 25+ ft.) | 5 ft. | 15 sq. ft. | Not listed | Sign must be setback at least 10 ft. from property line; establishment must be at least 25 ft. from property line. | 1 per site (included in max 3 signs per property). | Must be setback 10 feet or more from property line; only allowed for establishments setback 25+ feet from property line. | Not listed | Unlock | Sec. 5-505.2(2)(a)(ii)(a) |
| Pole Sign (Freestanding, Setback 25+ ft.) | 10 ft. | 10 sq. ft. | Not listed | Sign must be setback at least 10 ft. from property line; establishment must be at least 25 ft. from property line. | 1 per site (included in max 3 signs per property). | Must be setback 10 ft. or more from property line; allowed only where establishment is setback 25+ feet from property line. | Not listed | Unlock | Sec. 5-505.2(2)(a)(ii)(b) |
| Projecting Sign | 2 ft. | 6 sq. ft. | 3 ft. | Not listed | Not listed | Projecting from building. | Not listed | Unlock | Sec. 5-505.2(2)(a)(iii) |
| Window Sign | Not listed | 75% of total window area | Not listed | Not listed | Not listed | Principal facade window | Not listed | Unlock | Sec. 5-505.2(2)(a)(iv) |
| Wind Sign (banner/flag/pennant/etc.) | Not listed | Not listed | Not listed | Not listed | Not listed | Affixed to structure, not to compromise pedestrian or vehicular traffic. | Not listed | Unlock | Sec. 5-505.2(2)(a)(v) |
| Digital Sign / Electronically Changing Message Sign | Not listed | Not listed | Not listed | All digital/electronic signs shall have a minimum thirty-foot setback from residential property lines. | Only one digital/electronic sign per property. | Minimum 30-ft setback from residential property lines. Only one per property and not allowed where there is manual/mechanical changeable sign. | Not listed | Unlock | Sec. 5-505.2(2)(a)(vi) |
Business Districts (B-1)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | 25 sq. ft. | Not listed | Not listed | May have up to 3 signs on a property (total for all types), see general requirement. | On wall of building. | Not listed | Unlock | Sec. 5-505.2(2)(a)(i), 5-505.2(2)(c) |
| Monument Sign (Freestanding, Setback 25+ ft.) | 5 ft. | 15 sq. ft. | Not listed | Sign must be setback at least 10 ft. from property line; establishment must be at least 25 ft. from property line. | 1 per site (included in max 3 signs per property). | Must be setback 10 feet or more from property line; only allowed for establishments setback 25+ feet from property line. | Not listed | Unlock | Sec. 5-505.2(2)(a)(ii)(a) |
| Pole Sign (Freestanding, Setback 25+ ft.) | 10 ft. | 10 sq. ft. | Not listed | Sign must be setback at least 10 ft. from property line; establishment must be at least 25 ft. from property line. | 1 per site (included in max 3 signs per property). | Must be setback 10 ft. or more from property line; only allowed for establishments setback 25+ feet from property line. | Not listed | Unlock | Sec. 5-505.2(2)(a)(ii)(b) |
| Projecting Sign | 2 ft. | 6 sq. ft. | 3 ft. | Not listed | Not listed | Projecting from building. | Not listed | Unlock | Sec. 5-505.2(2)(a)(iii) |
| Window Sign | Not listed | 75% of total window area | Not listed | Not listed | Not listed | Principal facade window | Not listed | Unlock | Sec. 5-505.2(2)(a)(iv) |
| Wind Sign (banner/flag/pennant/etc.) | Not listed | Not listed | Not listed | Not listed | Not listed | Affixed to structure, not to compromise pedestrian or vehicular traffic. | Not listed | Unlock | Sec. 5-505.2(2)(a)(v) |
| Digital Sign / Electronically Changing Message Sign | Not listed | Not listed | Not listed | All digital/electronic signs shall have a minimum thirty-foot setback from residential property lines. | Only one digital/electronic sign per property. | Minimum 30-ft setback from residential property lines. Only one per property and not allowed where there is manual/mechanical changeable sign. | Not listed | Unlock | Sec. 5-505.2(2)(a)(vi) |
Business Districts (B-2)
| Sign Type | Max Height | Max Area | Max Width | Setback | Signs Allowed | Location | Permit Required | Premium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account) | Ordinance Citation |
|---|---|---|---|---|---|---|---|---|---|
| Wall Sign | Not listed | 25 sq. ft. | Not listed | Not listed | May have up to 3 signs on a property (total for all types), see general requirement. | On wall of building. | Not listed | Unlock | Sec. 5-505.2(2)(a)(i), 5-505.2(2)(c) |
| Monument Sign (Freestanding, Setback 25+ ft.) | 5 ft. | 15 sq. ft. | Not listed | Sign must be setback at least 10 ft. from property line; establishment must be at least 25 ft. from property line. | 1 per site (included in max 3 signs per property). | Must be setback 10 feet or more from property line; only allowed for establishments setback 25+ feet from property line. | Not listed | Unlock | Sec. 5-505.2(2)(a)(ii)(a) |
| Pole Sign (Freestanding, Setback 25+ ft.) | 10 ft. | 10 sq. ft. | Not listed | Sign must be setback at least 10 ft. from property line; establishment must be at least 25 ft. from property line. | 1 per site (included in max 3 signs per property). | Must be setback 10 ft. or more from property line; only allowed for establishments setback 25+ feet from property line. | Not listed | Unlock | Sec. 5-505.2(2)(a)(ii)(b) |
| Projecting Sign | 2 ft. | 6 sq. ft. | 3 ft. | Not listed | Not listed | Projecting from building. | Not listed | Unlock | Sec. 5-505.2(2)(a)(iii) |
| Window Sign | Not listed | 75% of total window area | Not listed | Not listed | Not listed | Principal facade window | Not listed | Unlock | Sec. 5-505.2(2)(a)(iv) |
| Wind Sign (banner/flag/pennant/etc.) | Not listed | Not listed | Not listed | Not listed | Not listed | Affixed to structure, not to compromise pedestrian or vehicular traffic. | Not listed | Unlock | Sec. 5-505.2(2)(a)(v) |
| Digital Sign / Electronically Changing Message Sign | Not listed | Not listed | Not listed | All digital/electronic signs shall have a minimum thirty-foot setback from residential property lines. | Only one digital/electronic sign per property. | Minimum 30-ft setback from residential property lines. Only one per property and not allowed where there is manual/mechanical changeable sign. | Not listed | Unlock | Sec. 5-505.2(2)(a)(vi) |
PermitPal covers all 8 zoning districts in Waynesburg. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.
Run a free code checkProhibited Signs in Waynesburg
- All signs not expressly permitted under this Ordinance or exempt from regulation hereunder in accordance with this Ordinance are prohibited in the Borough.
- Any sign attached to any tree, utility pole or painted upon or otherwise directly affixed to any rock, ledge or other natural feature is prohibited.
- No sign shall be erected in the public right-of-way, except for those placed by an authorized governmental agency.
- Signs are prohibited at any location where, by reason of position, shape, wording or color, they interfere with or obstruct the view of pedestrian or vehicular traffic.
- Signs are prohibited at any location which may be confused with any authorized traffic sign, signal or device.
- Signs are prohibited above the roof line.
- No sign shall be closer than twenty (20) feet to a side lot line, except in the case of (1) a wall sign, or (2) a corner lot where a setback may be reduced to ten (10) feet from public ways.
- No sign shall project from a building over a public way with the bottom of the sign less than eight (8) feet vertically above the ground.
- Any outdoor sign which advertises, identifies or pertains to any activity no longer in existence shall be removed by its owner or persons otherwise responsible within thirty (30) days from the time the activity ceases.
- Political signs must be removed within three (3) days after the election advertised.
- Signs employing neon, mercury vapor, low pressure and high pressure sodium, and metal halide lighting are prohibited, except those handed out by Waynesburg Prosperous and Beautiful.
- Signs on a vehicle not regularly used in the conduct of the business advertised on the vehicle are prohibited.
- Signs placed on bus shelters, bus benches, or waste receptacles are prohibited.
- Signs posted or painted on roofs, dormers, and balconies are prohibited.
- Off-premises signs are prohibited.
- The illumination from any sign may not cause any reflection or glare upon a public street, highway, sidewalk, or adjacent property.
- Directly illuminated signs of any nature in R-1, R-2, R-3, U-1, and U-2 Districts are prohibited.
- Exposed lighting sources such as bulbs, tubes, and the like are prohibited. All external sources of illumination must be hidden from view by shrubbery or some other permitted material.
- With the exception of B-1 and B-2 Districts, no exterior signs on any building or premises shall be illuminated after 12:00 midnight, except on those places of business which shall remain open after midnight, and they shall be extinguished at the time of closing such business.
Exempt Signs in Waynesburg
- The following signs do not require permits or fee payment but must meet the other requirements of the Ordinance: traffic control signs.
- Traffic flow informational signs to nonprofit and first responder facility are exempt.
- Building addresses, family name signs, decorative flags, no trespassing, and similar signs are exempt.
- Signs on vehicles regularly and customarily used to transport persons or property for the business are exempt.
- Directional signs set by governmental bodies are exempt.
- Political signs (4 sq. ft. or less) are exempt.
- The flags of any nation, state, town, military or service organization (15 sq. ft. or less) are exempt.
- Temporary signs are exempt.
- Safety control signs are exempt.
Sign Plan & Submission Notes for Waynesburg
- All signs require a permit from the Zoning Officer, except exempted signs as listed in Section 505.4.
- There is no mention of a master sign plan or sign plan submittal required for all signs across all zones in the provided ordinance text.
- Sign owners with projecting signs over a public way must provide to the municipality proof of liability insurance naming the municipality as the insured party.
Source: municode municipal code