Questions? Call us at (262) 218-2915

Sign Regulations in Westtown Township, Pennsylvania

Westtown Township, Pennsylvania has specific sign regulations covering 35 sign types across 10 zoning districts. Regulated sign types include Wall Sign, Projecting Sign, Window Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: April 28, 2025

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

Sign Regulation Overview for Westtown Township, Pennsylvania

Sample Sign Requirements in Westtown Township

Sign TypeMax HeightMax AreaSetback
Wall SignNot above top of wall; lowest edge minimum 10 ft above grade unless projection is <3"No more than 10% of the facade area per wallNot listed
Canopy or Awning SignLowest edge at least 8 ft above grade; not higher than eave lineNot listedNot listed
Projecting SignLowest edge at least 10 ft above grade; not above wall topNot listedNot listed

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for Westtown TownshipFull Coverage

Sign Types Covered

35

  • Wall Sign
  • Projecting Sign
  • Window Sign
  • Marquee Sign
  • +2 more types

Zoning Districts

10

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Westtown Township

Municipal Code2 permit application links available

Frequently Asked Questions

In Westtown Township, the height limit for Freestanding Sign (Ground/Pole) in the Commercial and Industrial uses and other zoning districts is 15 ft (Sec. 170-1813H). Other zones and sign types can have different limits. Run a code check for an exact address to see the limit that applies there.

Most commercial signs in Westtown Township require a permit. From the submission notes on this page: Before erecting, altering, repairing, or relocating any sign (unless exempt), a sign permit must be obtained. Permit applications must provide detailed plans (see above) and are subject to review and approval (§ 170-1815). Run a code check for an exact address to see the permit requirements for that zone.

Westtown Township's sign code covers 35 sign types, including Wall Sign, Projecting Sign, Window Sign, and Marquee Sign. Most commercial signs need a permit. The ordinance lists 14 exemptions. One of them: Legal notices. The full list is on this page.

In Westtown Township, Interior Site Freestanding Sign in the Institutional use zoning district must be set back 25 ft from property boundary for exemption (Sec. 170-1812E). Setbacks for other zones and sign types can differ. Run a code check for an exact address to see the setback that applies there.

Rules in Westtown Township's sign ordinance that cover digital, changing, or flashing signs: Animated signs, urban experiential displays, flashing signs, or signs that scroll or flash text or graphics. Conversion of a permitted non-message center sign to a message center sign, or a permitted nondigital sign to a digital sign, requires the issuance of a permit (§ 170-1805F(3)(f), § 170-1805F(4)(f)). Run a code check for an exact address to see the full illumination rules for that zone.

AI-Powered Research

Ready to Research Westtown Township Sign Permits?

Stop spending hours searching through municipal codes. Enter your address and PermitPal returns the sign rules that apply to your property in Westtown Township, Pennsylvania, with citations from the municipal code.

Need the sign code for this address?

PermitPal is an independent research tool for sign companies. We are not the city's permit office.

No credit card required · Get results in seconds

Westtown Township, Pennsylvania Sign Rules at a Glance

Westtown Township, Pennsylvania regulates 35 sign types across 10 zoning districts. Interior Site Freestanding Signs in the Institutional use zoning district are capped at 6 ft tall and 10 sq ft, set back 25 ft from property boundary for exemption (Sec. 170-1812E). Most commercial signs in Westtown Township require a permit.

Detailed Sign Ordinance Requirements for Westtown Township, Pennsylvania

Sign Rules by Zoning District in Westtown Township (10 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
General Regulations For All Zones1015 ft; min 4 ft between ground and bottom of sign faceMax 50% of area of any one sign, and not more than 30% total area for all signs; 100% for billboardsNot listed
C-2, Highway Commercial District424 ft (measured from avg grade in 50 ft radius)300 sq ftNot listed
Nonresidential zones38 ft freestanding; banners no higher than 24 ft when attached24 sq ft (freestanding/wall/window); 32 sq ft (banner)Not listed
Residential zones28 ft freestanding; banners max 24 ft if attached to structure16 sq ft (freestanding/wall/window); 32 sq ft (banner)Not listed
Agricultural use26 ft (8 ft along Route 926 or 352)15 sq ft per faceNot listed
Parks and Open Space, Institutional district (Park or Open Space Use)420 ft200 sq ftNot listed
Residential use212 ft15 sq ftNot listed
Institutional use76 ft (except educational/school use: 15 ft)24 sq ft maxNot listed
Commercial and Industrial uses, Commercial zoning district, Multiuse zoning district815 ftTotal signs on marquee structure: 200 sq ftNot listed
Planned Office Campus (POC) District33.5 ft40 sq ftNot listed

Zone-by-Zone Sign Requirements in Westtown Township(sample of 3 of 10 zones)

General Regulations For All Zones

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignNot above top of wall; lowest edge minimum 10 ft above grade unless projection is <3"No more than 10% of the facade area per wallNot listedNot listedMore than one permitted per wallAttached to building wall, parallel to wallNot listedUnlock§170-1806A
Canopy or Awning SignLowest edge at least 8 ft above grade; not higher than eave lineNot listedNot wider than the building wall or tenant space it identifies.Not listedNot listedLetters/numerals only on front and side vertical facesNot listedUnlock§170-1806B
Projecting SignLowest edge at least 10 ft above grade; not above wall topNot listedNot listedNot listedNot listedAttached perpendicular to building wall, not over public ROWNot listedUnlock§170-1806C
Window SignNot listedMax 25% of window area (35% for grocery/food market/pharmacies)Not listedNot listedNot listedInside or within 3 ft of window facing exteriorNot listedUnlock§170-1806D, §170-1804K
Marquee SignNo higher than eave line; lowest edge at least 10 ft above gradeNot listedMax width is entrance served plus 2 ft each sideNot listedNot listedAbove principal public entrance facing street/parking lotNot listedUnlock§170-1806E
Freestanding Sign (Ground Sign)3.5 ft (4.5 ft along Route 202 or 3)Not listedNot listedNot listedMax 1 per street frontageOutside public right-of-way and not in required clearancesNot listedUnlock§170-1806F
Message Center SignSame height as other sign type of same locationMax 50% of area of any one sign, and not more than 30% total area for all signs; 100% for billboardsNot listedNot listedMax one per street frontage, up to 2 per propertyPermitted for freestanding, monument, or wall signs where otherwise allowedNot listedUnlock§170-1805F(3)
Digital DisplaySame as other sign of type and locationMax 30% of total permitted sign area (unless billboard, then 100%)Not listedNot listedMax one per propertyPermitted for freestanding, monument, or wall signs where otherwise allowedNot listedUnlock§170-1805F(4)

Institutional use

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Large Limited Duration Sign (Educational/School Use)Not listed24 sq ft maxNot listedNot listed1On lot with educational/school useNot listedUnlock§170-1812A(1)
Small Limited Duration Sign (Educational/School Use)Not listed6 sq ft per signNot listedNot listed4On lot with educational/school useNot listedUnlock§170-1812A(2)-(3)
Freestanding Ground Sign6 ft (except educational/school use: 15 ft)24 sq ft (except educational/school use: 50 sq ft)Not listedNot listed1 per street frontage1 per street frontage (park/open space uses see next zone)Not listedUnlock§170-1812D
Wall SignUp to eave lineSee formulaNot listedNot listedMax 21 per street frontage, max 2; second may face parking lot for educational useNot listedUnlock§170-1812F
Awning or Canopy SignUp to eave lineNot listedNot listedNot listedNot listedNot listedNot listedUnlock§170-1812G
Projecting Sign (Educational Use)Up to eave line20 sq ft per sign faceNot listedNot listed1 per entrance1 per building entranceNot listedUnlock§170-1812H
Interior Site Freestanding Sign6 ft10 sq ftNot listed25 ft from property boundary for exemptionNot listedAt least 25 ft from nearest property boundary lineNot listedUnlock§170-1812E

Commercial and Industrial uses, Commercial zoning district, Multiuse zoning district

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements, available with a free PermitPal account)Ordinance Citation
Wall SignUp to eave linePer wall: 10% of facade; per property: up to 2 sq ft per linear foot building wall facing street.Not listedNot listed2 per tenant1 per tenant per street frontage, max 2 signs per tenant. Second sign can face parking lot if store has entrance on both.Not listedUnlock§170-1813C, §170-1806A
Awning or Canopy SignTo eave lineNot listedNot listedNot listedNot listedNot listedNot listedUnlock§170-1813D
Projecting SignTo eave line20 sq ft per sign faceNot listedNot listed1 per ground floor tenant + 1 per non-ground floor entrance1 per ground floor establishment, plus 1 per building entrance serving multiple tenants without ground entrance.Not listedUnlock§170-1813E
Window SignNot listedMax 25% of window area for permanent signs; max 35% with combination permanent + temporaryNot listedNot listedNot listedStorefront windowsNot listedUnlock§170-1813F, §170-1806D
Marquee SignTo eave lineTotal signs on marquee structure: 200 sq ftNot listedNot listed1 per building1 per buildingNot listedUnlock§170-1813G
Freestanding Sign (Ground/Pole)15 ft50 sq ft plus 10 sq ft per tenant, max 100 sq ftNot listedNot listed1 per street frontage (2 per property); extras for gas station/drive-thru1 per street frontage, up to 2 for property; exceptions for gas stations/drive-throughsNot listedUnlock§170-1813H
Planned Office Campus (POC) District Ground Sign3.5 ft24 sq ftNot listedNot listedNot listedNot listedNot listedUnlock§170-1813I
Planned Office Campus (POC) District Wall SignNot listed40 sq ftNot listedNot listedNot listedNot listedNot listedUnlock§170-1813I

PermitPal covers all 10 zoning districts in Westtown Township. Run a code check for your exact address to get the zone that applies to your property and its full sign requirements with a free account: illumination rules, size formulas, and permit requirements for every sign type.

Run a free code check

Prohibited Signs in Westtown Township

  • Abandoned signs.
  • Snipe signs. Signs shall only be attached to utility poles in conformance with state and utility regulations and the requirements of this chapter.
  • Mechanical movement signs, including revolving signs.
  • Pennant strings and streamers, except when located inside a stadium, arena, or temporary fairground during a special event.
  • Animated signs, urban experiential displays, flashing signs, or signs that scroll or flash text or graphics.
  • Inflatable devices or balloon signs, with the exception of balloons used in temporary situations.
  • Signs which interfere with, imitate, or resemble any public sign, signal, or device within 75 feet of a public right-of-way or within 200 feet of a traffic control device, whichever is greater.
  • Any signs located within a public right-of-way and/or which obscure or interfere with the line of sight at any street intersection or traffic signal, or at any other point of vehicular access to a street.
  • Signs which prevent free ingress or egress from any door, window, fire escape, or that prevent free access from one part of a roof to any other part. No sign shall be attached to a standpipe or fire escape that creates confusion or interferes with its use and operation.
  • Signs which emit smoke, visible vapors, particulate matter, sound, odor or contain open flames.
  • Reflective signs or signs containing mirrors, excluding those as approved by the Township or PennDOT for traffic use.
  • Interactive signs.
  • Signs incorporating beacon or festoon lighting.
  • Any banner or sign of any type suspended across a public street, without the permission of the owner of the property and road.
  • Roof signs, or any portion thereof, which extends above the roofline of any building.
  • Signs erected without the permission of the property owner, with the exception of those authorized or required by local, state, or federal government.
  • Any sign having content that is not subject to the protections of the First Amendment to the United States Constitution or Article I, Section 7, of the Pennsylvania Constitution, including but not limited to obscenity/pornography, fighting words, and incitement to imminent lawless action.
  • No sign shall be placed in such a position as to endanger pedestrians, bicyclists, or traffic on a street by obscuring the view or by interfering with government street signs or signals by virtue of position or color.
  • Except for signs classified as exempt under § 170-1804, no sign may be located within any public right-of-way and/or occupy a clear sight triangle of 75 feet (as measured from the center-line intersections of two streets), increased to 100 feet for a collector street or 150 feet for an arterial highway.
  • Signs and their supporting structures shall maintain clearance and noninterference with all surface and underground utility and communications lines or equipment.
  • Signs must not create traffic hazards by distracting or confusing motorists, or impairing motorist ability to see pedestrians, vehicles, obstacles, or traffic signs.
  • Signs must not create hazards due to collapse, fire, collision, decay, or abandonment.
  • Prohibit the erection of signs in such numbers, sizes, designs, illumination, and locations as may create hazards to pedestrians and motorists.
  • Avoid excessive conflicts from large or multiple signs to minimize clutter, unsightliness, and confusion.
  • Message sequencing across more than one billboard sign is prohibited.

Exempt Signs in Westtown Township

  • Government signs constructed and/or installed by the federal, state, county or municipal government or an agency or department thereof and to include the United States Postal Service.
  • Signs inside a building, or other enclosed facility, which are not meant to be viewed from the outside, and are located greater than three feet from the window.
  • Address signs: Up to two signs required by the federal, state, county or municipal government or a department or agency thereof, including the United States Post Office, provided they meet specified size requirements (1 sq ft residential, 5 sq ft nonresidential).
  • Public signs: Signs erected or required by government agencies or utilities, including those located in the public right-of-way, at railroad crossings, on buildings with public conveniences, not to exceed two square feet.
  • Private drive signs: One sign per driveway entrance, not to exceed four square feet in area.
  • Security and warning signs: Residential uses not exceeding four square feet; nonresidential uses one large sign not exceeding five square feet, others up to four square feet.
  • Flags and insignia of any municipal, state or federal government.
  • Legal notices.
  • Permanent architectural features of a building or structure, such as a cornerstone, carving, or embossment, provided that the letters are not made of reflective material nor contrast in color with the building.
  • Signs within four feet of a crop growing in a field, not exceeding four square feet, removed after harvest.
  • Incidental signs, including incidental window signs, when total area does not exceed two square feet.
  • Street pole banners, located outside public rights-of-way, interior to a campus, institutional, or commercial use, subject to specific size, height, and placement standards.
  • Temporary signs in accordance with § 170-1808, Regulations by sign type (limited duration, temporary and portable signs).
  • Any canopy or awning, as defined herein, which does not have any lettering, logos or symbols printed, painted or otherwise affixed thereto.

Sign Plan & Submission Notes for Westtown Township

  • A completed sign permit application must include a site plan drawn to scale showing lot dimensions, building frontage, existing cartways, rights-of-way, driveways, design of each sign face and structure with all measurements, elevations, facades, parapet walls, eave line, and the location and size of all proposed and existing permanent signage (§ 170-1815).
  • Plans for billboard signs must be certified by a licensed engineer registered in Pennsylvania, and shall show the location of the proposed sign, required setbacks, location/species of trees, distances to other features, a site plan with all requirements set forth in the Zoning Code, and engineer certification (§ 170-1807L).
  • Conversion of a permitted non-message center sign to a message center sign, or a permitted nondigital sign to a digital sign, requires the issuance of a permit (§ 170-1805F(3)(f), § 170-1805F(4)(f)).
  • If a nonconforming sign is required to be moved because of right-of-way improvements, plan requirements for billboards must also be met (§ 170-1816C(7)).
  • Before erecting, altering, repairing, or relocating any sign (unless exempt), a sign permit must be obtained. Permit applications must provide detailed plans (see above) and are subject to review and approval (§ 170-1815).
  • Permits for illuminated signs will not be issued without an approved electrical permit, if required, and electrical applications must be filed together with the sign permit application (§ 170-1805F(5)).

Source: ecode360 municipal code