Sign Regulations in Anderson, South Carolina

Anderson, South Carolina has specific sign regulations covering 17 sign types across 6 zoning districts. Regulated sign types include Single-Tenant Monument Sign, Ground-Mounted Temporary Sign, On-Site Traffic Directional Sign. Height restrictions apply. Permits are required for most commercial signs. Use PermitPal to get instant access to the complete regulations.

Data last verified: May 7, 2025

Sign Regulation Overview for Anderson, South Carolina

Sample Sign Requirements in Anderson

Sign TypeMax HeightMax AreaSetback
Single-Tenant Monument SignFreestanding signs must be located a minimum of five feet from all property lines, rights-of-way, and utility easements (Sec. 12.6 B)
Ground-Mounted Temporary SignMin 5' from property lines, rights-of-way, utility easements (Sec. 12.6 B)
Post Sign6 ft6 sq ftMin 5' from property lines, rights-of-way, and utility easements

* Sample data shown. Actual requirements may vary by zone. Use PermitPal for complete, location-specific regulations.

PermitPal Coverage for AndersonFull Coverage

Sign Types Covered

17

  • Single-Tenant Monument Sign
  • Ground-Mounted Temporary Sign
  • On-Site Traffic Directional Sign
  • Wall Sign
  • +2 more types

Zoning Districts

6

Different zoning districts with specific sign regulations

Data Includes

  • Permit requirements
  • Height restrictions
  • Illumination rules

Official Resources for Anderson

City WebsiteMunicipal Code2 permit application links available

Frequently Asked Questions

Sign height limits in Anderson vary by zone and sign type. Wall signs typically range from 25-40 feet, while monument signs are usually limited to 6-10 feet. Use PermitPal to get exact requirements for your property.

To get a sign permit in Anderson, submit an application to the local building or planning department with sign dimensions, location, and design specifications. Our data confirms permits are required for most commercial signs. Processing typically takes 1-4 weeks. PermitPal helps you identify specific requirements and prepare complete applications.

In Anderson, regulated sign types include Single-Tenant Monument Sign, Ground-Mounted Temporary Sign, On-Site Traffic Directional Sign, Wall Sign, and 2 more types. Most commercial signs require permits. Temporary signs and certain small signs may be exempt. Use PermitPal for specific exemptions.

In Anderson, monument signs typically require a Freestanding signs must be located a minimum of five feet from all property lines, rights-of-way, and utility easements (Sec. 12.6 B) setback from property lines. Setbacks may increase near residential zones or intersections. Wall signs attached to buildings generally don't have setback requirements. Use PermitPal for location-specific setback data.

Digital and LED signs in Anderson are regulated with specific requirements for brightness, animation, and message duration. Anderson has documented illumination rules in our database. Use PermitPal to see the exact requirements for electronic message centers.

AI-Powered Research

Ready to Research Anderson Sign Permits?

Stop spending hours searching through municipal codes. Get instant access to Anderson, South Carolina sign regulations with PermitPal's AI-powered platform.

No credit card required · Get results in seconds

Anderson, South Carolina Sign Rules at a Glance

Anderson, South Carolina regulates 17 sign types across 6 zoning districts. Single-Tenant Monument Signs in the NP, NC, LO, Neighborhood/Professional/Local Office Districts (NP, NC, LO) zoning district are capped at 5 ft tall and 25 sq ft, with a Min 5 ft from property lines, rights-of-way, or easements setback (Sec. Table 12-02, Sec. 12.4(B)). Most commercial signs in Anderson require a permit.

Detailed Sign Ordinance Requirements for Anderson, South Carolina

Sign Rules by Zoning District in Anderson (6 zones)

Zoning DistrictSign Types RegulatedMax HeightMax AreaPermit Required
RA, R-40, R-20, R-15, R-10, R-5, Residential Districts (RA, R-40, R-20, R-15, R-10, R-5)46 ft6 sq ft
RG, RM-10, RM-18, Multifamily Residential Districts (RG, RM-10, RM-18)56 ft6 sq ft
NP, NC, LO, Neighborhood/Professional/Local Office Districts (NP, NC, LO)1312 ft or roofline (whichever is less)80 sq ft (aggregate), 60 sq ft (individual)
CBD, Central Business District (CBD)912 ft or roofline (whichever is less)80 sq ft per lane (aggregate), 60 sq ft per sign
GC, LI, HI, General Commercial and Industrial Districts (GC, LI, HI)1316 ft100 sq ft
General Regulations For All Zones2

Zone-by-Zone Sign Requirements in Anderson(sample of 3 of 6 zones)

NP, NC, LO, Neighborhood/Professional/Local Office Districts (NP, NC, LO)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignMay not protrude above sill of second-story windows10% of wall faceSingle-tenant: Up to 3 (one per facade); multi-tenant: one per tenantBuilding facadeUnlockTable 12-02, Sec. 12.4(A)
Single-Tenant Monument Sign5 ft25 sq ftMin 5 ft from property lines, rights-of-way, or easements1 per lot frontageMinimum 5 ft from property lines, rights-of-way, utility easementsUnlockTable 12-02, Sec. 12.4(B)
Multi-Tenant Monument Sign10 ft50 sq ftMin 5 ft from property lines, right-of-way, easements1 per lot frontageUnlockTable 12-02, Sec. 12.4(C)
Projecting Sign12 ft or roofline (whichever is less)4 sq ft1 per ground floor tenantMay project over ROWUnlockTable 12-02, Sec. 12.4(E)
On-Site Traffic Directional Sign4 ft4 sq ftMin 5' from property lines, rights-of-way, utility easementsAs determined by directorUnlockTable 12-02 (●); Sec. 12.4(G)
Fuel Pump Canopy SignMay not protrude above or below the canopy20 sq ftMax 3 per canopy, 1 per facadeOn canopyUnlockTable 12-02; Sec. 12.4(H)
Drive-Through Sign10 ft80 sq ft (aggregate), 60 sq ft (individual)2 per laneWithin 5 ft of drive-through laneUnlockTable 12-02; Sec. 12.4(I)
A-Frame/Sandwich Board Sign4 ft6 sq ft1 per single-tenant or tenant of multi-tenant bldgWithin 6 ft of building entranceUnlockTable 12-02 (○); Sec. 12.5(E)

CBD, Central Business District (CBD)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignNot to protrude above sill of 2nd-story windows5% of wall faceUp to 3 for single-tenant (1 per facade); 1 per tenant in multi-tenantBuilding facadeUnlockTable 12-02; Sec. 12.4(A)
Projecting Sign12 ft or roofline (whichever is less)4 sq ft1 per ground floor tenantMay project over right-of-way with approvalUnlockTable 12-02; Sec. 12.4(E)
Window Sign, Permanent4 sq ft or 25% of window areaOn windowUnlockTable 12-02; Sec. 12.4(F)
On-Site Traffic Directional Sign4 ft4 sq ftMin 5' from property line, ROW, or utility easementAs determined by directorUnlockTable 12-02 (●); Sec. 12.4(G)
Fuel Pump Canopy SignCannot protrude above or below canopy20 sq ft3 per canopy (1 per facade)On canopyUnlockTable 12-02; Sec. 12.4(H)
Drive-Through Sign10 ft80 sq ft per lane (aggregate), 60 sq ft per sign2 per laneWithin 5 ft of drive-through laneUnlockTable 12-02, Sec. 12.4(I)
Wall-Mounted Banner Sign5 sq ftSingle tenant: 1; multi-tenant: 1/tenant; max 3 per propertyAffixed to building onlyUnlockTable 12-02, Sec. 12.5(B)
A-Frame/Sandwich Board Sign4 ft6 sq ft1 per tenantWithin 6 ft of entranceUnlockTable 12-02 (○); Sec. 12.5(E)

GC, LI, HI, General Commercial and Industrial Districts (GC, LI, HI)

Sign TypeMax HeightMax AreaMax WidthSetbackSigns AllowedLocationPermit RequiredPremium Details(Illumination, Size Formula, Permit Requirements, Additional Requirements — available with a free PermitPal account)Ordinance Citation
Wall SignNot above sill of second-story windows15% of wall faceUp to 3 (single tenant, one per facade); one per tenant in multi-tenantBuilding facadeUnlockTable 12-02; Sec. 12.4(A)
Single-Tenant Monument Sign8 ft50 sq ft5 ft from property lines, rights-of-way, and utility easements1 per lot frontageMin 5 ft from property line, ROW, or utility easementUnlockTable 12-02; Sec. 12.4(B)
Multi-Tenant Monument Sign16 ft100 sq ft5 ft from property lines, rights-of-way, utility easements1 per lot frontageUnlockTable 12-02; Sec. 12.4(C)
Projecting Sign12 ft or roofline (whichever less)4 sq ft1 per ground floor tenantMay project over ROWUnlockTable 12-02; Sec. 12.4(E)
On-Site Traffic Directional Sign4 ft4 sq ft5 ft from property lines, ROW, utility easementsAs neededUnlockTable 12-02 (●); Sec. 12.4(G)
Fuel Pump Canopy SignNot above/below canopy20 sq ft3 per canopy (1 per facade)On canopyUnlockTable 12-02; Sec. 12.4(H)
Drive-Through Sign10 ft80 sq ft per lane (aggregate); no sign over 60 sq ft2 per laneWithin 5 ft of drive-through laneUnlockTable 12-02; Sec. 12.4(I)
A-Frame/Sandwich Board Sign4 ft6 sq ft1 per tenantWithin 6 ft of building entranceUnlockTable 12-02 (○); Sec. 12.5(E)

PermitPal covers all 6 zoning districts in Anderson — full sign requirements for every zone, plus illumination rules, size formulas, and permit requirements for every sign type — with a free account.

See all 6 zones for Anderson — start free

Prohibited Signs in Anderson

  • Off-premises outdoor advertising signs are prohibited.
  • Feather signs are prohibited.
  • Pole/pylon signs are prohibited.
  • Flashing signs are prohibited.
  • Roof signs are prohibited.
  • Marquee signs are prohibited.
  • Outline/rope lighting is prohibited.
  • Signs attached to a utility pole, a tree, a fence, a standpipe, gutter, drain or fire escape are prohibited.
  • Signs erected so as to impair access to a roof are prohibited.
  • Signs located, erected or maintained upon, over, or project into any public or private right-of-way or easement unless otherwise allowed by this ordinance are prohibited.
  • Pennants, streamers, and portable signs not specifically permitted or allowed by this ordinance are prohibited.
  • Signs (not specifically permitted or allowed by this ordinance) which move or have moving parts, whether caused by wind or mechanically, are prohibited.
  • Signs in conflict with traffic signals, vehicular or pedestrian travel, access to fire hydrants and fire lanes/exits, or signs that impede or impair public health, safety, and welfare are prohibited.
  • Signs on vehicles, boats, or trailers parked so as to be visible from a public right-of-way are prohibited.
  • Attention getting devices are prohibited.
  • Signs hung across any street or alley are prohibited.
  • Signs painted on or otherwise affixed to fences are prohibited.
  • Text or graphics of an indecent or immoral nature and harmful to minors are prohibited.
  • Text or graphics that advertise unlawful activity are prohibited.
  • Text or graphics that are obscene, fighting words, defamation, incitement to imminent lawless action, or true threats are prohibited.
  • Text or graphics that present a clear and present danger due to their potential confusion with traffic control signs or public safety information signs (e.g., use of 'Stop,' 'Yield,' 'Caution,' or 'Danger' to imply a safety hazard that does not exist) are prohibited.

Exempt Signs in Anderson

  • Yard signs in residential districts displayed for a period of 48 hours or less are exempt from the requirements of Section 12.5.
  • Temporary wall-mounted banner or ground-mounted temporary signs do not require a sign permit if the property is actively marketed for sale or lease, provided all requirements of Section 12.5 are met.

Sign Plan & Submission Notes for Anderson

  • Irregularly shaped lots with minimal lot frontage may petition for additional aggregate sign area through the comprehensive sign plan process (Section 12.3(C)).
  • A comprehensive sign plan may be elected for any building or development; after approval, no permanent sign shall be erected, placed, or maintained except in conformance with the comprehensive sign plan (Section 12.11(B)).
  • The director may approve alternate color schemes for monument signs as part of a comprehensive sign plan.
  • Comprehensive sign plan applications in historic overlay districts are reviewed by the board of architectural review; in all other districts, they are reviewed by the planning commission, with appeals to the board of zoning appeals (Section 12.11(F)-(G)).

Source: municode municipal code